metricas
covid
Buscar en
Actas Urológicas Españolas
Toda la web
Inicio Actas Urológicas Españolas Esfínter Urinario Artificial “FlowSecureTM”: Un nuevo concepto de esfínter...
Journal Information
Vol. 31. Issue 7.
Pages 752-758 (January 2007)
Share
Share
Download PDF
More article options
Vol. 31. Issue 7.
Pages 752-758 (January 2007)
Esfínter Urinario Artificial “FlowSecureTM”: Un nuevo concepto de esfínter artificial regulable y con oclusión condicional para la incontinencia urinaria de esfuerzo
“FlowsecureTM” artificial urinary sphincter: a new adjustable artificial urinary sphincter concept with conditional occlusion for stress urinary incontinence
Visits
1683
F. García Montes1,**, S.L. Knight***, T. Greenwell*, A.R. Mundy*, M.D. Craggs*
* Institue of Urology and Nephrology.University College of London
** Hospital Universitario Son Dureta. Palma de Mallorca
This item has received
Article information
Resumen
Introducción

Difundir el concepto de un nuevo esfínter urinario artificial con oclusión condicional para el tratamiento de la incontinencia urinaria de esfuerzo. El prototipo fue concebido y diseñado por los profesores Craggs M. y Mundy A.R. en el Instituto de Urología y Nefrología de Londres.

Materiales y Métodos

El esfínter FlowSecure es un prototipo de una sola pieza de silicona llena de suero salino que consta de: 1) Un reservorio regulador de presión, 2) un reservorio de asistencia al estrés, 3) una bomba de control con un puerto autosellable y 4) un manguito. El reservorio regulador determina la presión de la prótesis y se puede ajustar desde 0 a 80 cm H2O mediante la inyección o extracción de líquido a través del puerto autosellable (oclusión basal). El reservorio de asistencia al estrés transmite de forma reversible los aumentos de la presión intra-abdominal durante los periodos de esfuerzo (oclusión condicional).

Resultados

La técnica quirúrgica de implantación es simple, reduciendo la posibilidad de infección y errores de ensamblaje. La asociación en serie de un reservorio regulador de presión con un reservorio de asistencia al estrés permite establecer presiones de oclusión basal bajas y el aumento condicional de la misma durante los periodos de estrés, reduciendo el riesgo de atrofia y erosión. Tras la implantación, la presión es ajustable dependiendo de las necesidades clínicas del paciente.

Discusión

El esfínter FlowSecure está diseñado para corregir la incontinencia ajustando la presión de oclusión según las necesidades individuales de cada paciente, así como para reducir las complicaciones asociadas al exceso de presión de oclusión y los fallos mecánicos.

Palabras clave:
Esfínter urinario artificial
Oclusión condicional
Abstract
Introduction

To spread de concept of a new artificial urinary sphincter with conditional occlusion for stress incontinence. The new prototype was conceived and designed in The Institute of Urology and Nephrology of London by Professor Craggs M. and Professor Mundy A.R.

Methods

The FlowSecure sphincter consists of an adjustable pressure-regulating balloon, a stress relief reservoir, a control pump and valve assembly unit with self-sealing port and a urethral cuff. The pressure regulating balloon determinates de operating pressure of the device; the pressure is adjustable in the range 0-80 cm H2O and can be altered by injection or removal of normal saline through the self sealing port. The stress relief balloon transmits transient intrabdominal pressure to the cuff during periods of stress. An adjustable circular urethral cuff minimises creasing and possible stress fractures.

Results

The device is implanted as a one-piece assembly which is pre-filled with sterile saline. The surgical technique is simple and associated with little handling, reducing risk of infection and potential assembly errors. The adjustable pressure regulating balloon in association with the stress relief reservoir enables the cuff occluding pressure to be set at a low range, therefore reducing the risk for atrophy and erosion.

Discussion

The new FlowSecure urinary artificial sphincter with conditional occlusion is designed to provide good continence rates adjusting regulating pressures when needed and conceived to reduce the risk of potential complications associated with excessive occluding pressures and mechanical failures.

Key words:
Artificial urinary sphincter
Conditional occlusion

Article

These are the options to access the full texts of the publication Actas Urológicas Españolas
Subscriber
Subscriber

If you already have your login data, please click here .

If you have forgotten your password you can you can recover it by clicking here and selecting the option “I have forgotten my password”
Subscribe
Subscribe to

Actas Urológicas Españolas

Purchase
Purchase article

Purchasing article the PDF version will be downloaded

Price 19.34 €

Purchase now
Contact
Phone for subscriptions and reporting of errors
From Monday to Friday from 9 a.m. to 6 p.m. (GMT + 1) except for the months of July and August which will be from 9 a.m. to 3 p.m.
Calls from Spain
932 415 960
Calls from outside Spain
+34 932 415 960
E-mail
Article options
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos