Perfusión hipotérmica del riñón aislado: respuesta hidrodinámica y bioquímica al perfil de aplicación de la presión
Visits
1742
E. Lledó García1,a, C. Hernández Fernándeza, J.I. Martínez-Salamancaa, M. Moralejo Gáratea, R. Cabello Benaventea, D. Subirá Ríosa, J.F. Del Cañizo López*,a
* Depto. de Medicina y Cirugía Experimental
a Servicio de Urología.Hospital General Universitario Gregorio Marañón.Madrid
This item has received
Article information
Resumen

Perfusión hipotérmica del riñón aislado: respuesta hidrodinámica y bioquímica al perfil de aplicación de la presión

Objetivos

Evaluar el efecto hidrodinámico, bioquímico e histológico de la presión positiva brusca en la perfusión del riñón aislado en hipotermia frente a la administración suave y progresiva de la solución de perfusión.

Material Y métodos

16 perfusiones hipotérmicas de 180 min. llevadas a cabo en condiciones de flujo constante en riñones de cerdo isogénico miniatura. Se utilizó una bomba de vacío regulada informáticamente. Se compararon los resultados obtenidos por los riñones prefundidos de forma brusca (I.B.) frente a aquellos prefundidos de forma suave y progresiva (I.S.).

Resultados

A pesar de que ambos grupos de órganos consiguieron flujos de perfusión medios similares, el grupo I.B. mostró valores medios de presión de perfusión y resistencia vascular mayores. La concentración de metabolitos de óxido nítrico fue también más alta en el grupo I.B. Los riñones del grupo I.B. expusieron más edema tubular y retracción glomerular.

Conclusiones

La perfusión hipotérmica brusca y forzada del riñón aislado no permite conseguir un flujo de perfusión mayor. Al contrario, de forma global los resultados hidrodinámicos e histológicos son de peor calidad en comparación a los órganos prefundidos de forma suave y progresiva.

Palabras clave:
Trasplante renal
Preservación renal
Perfusión
Abstract

Hydrodynamic and biochemical adaptation to perfusion pressure profile in isolated hypothermic renal perfusion

Objectives

To evaluate hydrodynamic, biochemical and pathologic consequences of positive forced pressure on hypothermic isolated renal perfusions in comparison to softly progressive administration of perfusion solution.

Material & methods

16 hypothermic experimental pig renal perfusion o 180 min completed under constant flow conditions. A vacuum computer-controlled pump was used. A comparison was performed of the results obtained by two groups of organs (forced perfusion pressure -I.B.- and soft perfusion pressure -I.S.).

Results

Even though perfusion flor did not offer significant differences among both groups at the end of the procedure, I.B. group showed medium perfusion pressure and renal vascular resistance values significantly higher. Nitric oxide metabolites concentration was also greater in I.B. group. Finally, these kidneys showed more tubular cell aedema and glomerular shrinkage in comparison to I.S. group.

Conclusion

Sharp and forced hypothermic perfusion of the isolated kidney don’t increase flow perfusion values. Inversely, hydrodynamic and pathologic results are worst in comparison to soft and progressive organ perfusion.

Keywords:
Kidney transplant
Renal preservation
Perfusion

Article

These are the options to access the full texts of the publication Actas Urológicas Españolas
Subscriber
Subscriber

If you already have your login data, please click here .

If you have forgotten your password you can you can recover it by clicking here and selecting the option “I have forgotten my password”
Subscribe
Subscribe to

Actas Urológicas Españolas

Purchase
Purchase article

Purchasing article the PDF version will be downloaded

Price 19.34 €

Purchase now
Contact
Phone for subscriptions and reporting of errors
From Monday to Friday from 9 a.m. to 6 p.m. (GMT + 1) except for the months of July and August which will be from 9 a.m. to 3 p.m.
Calls from Spain
932 415 960
Calls from outside Spain
+34 932 415 960
E-mail
Article options
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos