metricas
covid
Buscar en
Gastroenterología y Hepatología
Toda la web
Inicio Gastroenterología y Hepatología Protocolo de adquisición de imágenes y medición de la elasticidad pancreátic...
Journal Information
Vol. 47. Issue 9.
(November 2024)
Share
Share
Download PDF
More article options
Visits
111
Vol. 47. Issue 9.
(November 2024)
Original
Protocolo de adquisición de imágenes y medición de la elasticidad pancreática mediante elastografía por onda de cizallamiento bidimensional (2D-SWE) transabdominal
Protocol for acquisition of images and measurement of transabdominal ultrasound pancreatic two-dimensional shear wave elastography (2D-SWE)
Visits
111
Eva Marín-Serrano
Corresponding author
, Ana Barbado Cano, Rubén Fernández Martos, Marta Abadía Barno, Antonio Olveira Martín, Maria Dolores Martín Arranz
Servicio de Aparato Digestivo, Hospital La Paz, Madrid, España
This item has received
Article information
Abstract
Full Text
Bibliography
Download PDF
Statistics
Figures (3)
Show moreShow less
Tables (1)
Tabla 1. Análisis de fiabilidad
Resumen
Introducción

La elastografía pancreática transabdominal (TA) usando 2D-SWE es una técnica en desarrollo que requiere ser protocolizada.

Objetivos

Establecer un protocolo de adquisición de imágenes y medición de la elasticidad pancreática usando 2D-SWE-TA y estimar el número mínimo de medidas a realizar.

Material y métodos

Se tomaron 10 medidas de la elasticidad pancreática en voluntarios sanos usando 2D-SWE-TA, siguiendo un protocolo estricto de adquisición de imágenes y medición.

Resultados

El 70% eran mujeres, con una edad, peso e IMC de 49,5±15,7 años, 65,9±11,9kg y 24,5±4,2kg/m2, de media, respectivamente. Las mediciones se realizaron en cuerpo (70%), cola (16,7%) y cabeza (13,3%/30) pancreática. La media de la mediana de la velocidad y elasticidad fue de 1,46±0.25cm/s y 6,46±2,87KPa, respectivamente. La profundidad del ROI fue 4,12±1cm y la distancia SP-ROI fue 5,2mm, de media. No hubo diferencias estadísticamente significativas entre las 10 medidas. El análisis de fiabilidad de las medidas mostró una elevada consistencia interna y repetibilidad. La toma de 5-6 medidas aseguraba una alta concordancia con las 10 medidas de referencia. Las medidas eran significativamente inferiores cuando los valores de SP-ROI eran intermedios (0,3-0,6cm). La precisión en la medida era mayor si se realizaba a una profundidad inferior a 4,8cm.

Conclusión

Para medir la elasticidad pancreática mediante 2D-SWE-TA proponemos un protocolo estricto de adquisición de imágenes y medición, la toma de un mínimo de 5 medidas en la porción pancreática mejor visualizada y accesible, y a ser posible a una profundidad menor de 4,8cm.

Palabras clave:
Elasticidad pancreática
2-D shear wave elastography (2D-SWE)
Ecografía abdominal
Abstract
Introduction

Transabdominal ultrasound (TU) pancreatic 2D-SWE elastography is a developing technique that needs to be protocolized.

Objectives

Establish a protocol for image acquisition and measurement of TU pancreatic - 2D-SWE elastography and estimate the minimum number of measurements to be performed.

Materials and methods

Ten measurements of pancreatic elasticity were taken in healthy volunteers using TU-2D-SWE, following a strict protocol for image acquisition and measurement.

Results

The 70% of the participants were women, with an average age, weight, and BMI of 49.5±15.7 years, 65.9±11.9kg, and 24.5±4.2kg/m2, respectively. Measurements were taken from the body (70%), tail (16.7%), and pancreatic head (13.3%). The median mean velocity and elasticity were 1.46±0.25cm/sec and 6.46±2.87KPa, respectively. The ROI depth was 4.12±1cm and the SP-ROI distance was 5.2mm on average. There were no statistically significant differences between the 10 measurements. The reliability analysis of the measurements showed high internal consistency and repeatability. Taking 5-6 measurements ensured high concordance with the ten reference measurements. The measurements were significantly lower when the SP-ROI values were intermediate (0.3-0.6cm). The measurement accuracy was higher when performed at a depth less than 4.8cm.

Conclusion

To measure pancreatic elasticity using TU-2D-SWE, we propose a strict protocol for image acquisition and measurement, taking a minimum of 5 measurements in the best visualized and accessible pancreatic portion, and preferably at a depth of less than 4.8cm.

Keywords:
Pancreatic elastography
2-D shear wave elastography (2D-SWE)
Transabdominal ultrasound

Article

These are the options to access the full texts of the publication Gastroenterología y Hepatología
Subscriber
Subscriber

If you already have your login data, please click here .

If you have forgotten your password you can you can recover it by clicking here and selecting the option “I have forgotten my password”
Subscribe
Subscribe to

Gastroenterología y Hepatología

Purchase
Purchase article

Purchasing article the PDF version will be downloaded

Price 19.34 €

Purchase now
Contact
Phone for subscriptions and reporting of errors
From Monday to Friday from 9 a.m. to 6 p.m. (GMT + 1) except for the months of July and August which will be from 9 a.m. to 3 p.m.
Calls from Spain
932 415 960
Calls from outside Spain
+34 932 415 960
E-mail
Article options
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos