metricas
covid
Buscar en
Medicina Clínica
Toda la web
Inicio Medicina Clínica Cáncer y desfibrilador automático implantable ¿causalidad, confusión o casua...
Journal Information
Vol. 157. Issue 10.
Pages 459-463 (November 2021)
Share
Share
Download PDF
More article options
Visits
16
Vol. 157. Issue 10.
Pages 459-463 (November 2021)
Original
Cáncer y desfibrilador automático implantable ¿causalidad, confusión o casualidad?
Cancer and implantable cardiac defibrillator. Causality, confusion or chance?
Visits
16
Ignacio Roya,
Corresponding author
iroy.md@gmail.com

Autor para correspondencia.
, Lorena Malagona, Javier Martíneza, Javier Romeroa, Aitziber Munarriza, Nuria Basterraa,b
a Cardiología, Área Clínica del Corazón, Complejo Hospitalario de Navarra, Pamplona, España
b Instituto de Investigación Sanitaria de Navarra (IdiSNA), Navarra, España
This item has received
Article information
Abstract
Full Text
Bibliography
Download PDF
Statistics
Tables (4)
Tabla 1. Características sociodemográficas y clínicas
Tabla 2. Datos sobre mortalidad
Tabla 3. Datos oncológicos
Tabla 4. Modelo de riesgos competitivos de Fine-Gray para el desarrollo de cáncer tras la implantación de un DAI
Show moreShow less
Resumen
Introducción y objetivos

El desfibrilador automático implantable (DAI) se ha establecido como terapia en pacientes con elevado riesgo de sufrir arritmias ventriculares malignas.

Algunos estudios plantean un posible efecto oncogénico de materiales protésicos utilizados. Igualmente, existen trabajos que describen mayor incidencia de cáncer en portadores de DAI y plantean una potencial relación causal entre ambos.

El objetivo principal del estudio es describir la incidencia de cáncer en nuestra muestra de pacientes portadores de DAI y compararla con resultados de otras bases de datos.

Métodos

Estudio de cohortes retrospectivo de pacientes con DAI que se incluyeron en el Complejo Hospitalario de Navarra entre los años 2000 y 2016 y se siguieron hasta junio de 2018.

Se analizaron variables sociodemográficas, comorbilidades y datos sobre patología oncológica.

Se estimaron tasas de incidencia acumulada (TIA) de cáncer durante el seguimiento que se compararon con datos poblacionales y con datos de otra cohorte de pacientes con insuficiencia cardiaca con FEVI reducida. Se ajustaron modelos de riesgos competitivos para cáncer en el seguimiento.

Resultados

Se incluyeron 497 pacientes, mayoritariamente hombres (89,1%) con una edad media de 59,98 (14,98) años, con una proporción de fumadores del 67,6% y de cardiopatía isquémica del 51,6%. La TIA de cáncer fue 1.230,9 por 100.000 personas-año. Las variables que se asociaron significativamente con cáncer fueron mayor edad, mayor consumo de tabaco y cardiopatía isquémica.

Conclusiones

La incidencia de cáncer es elevada en pacientes con DAI. Este hallazgo parece relacionado principalmente con el tabaco y la mayor edad.

Palabras clave:
Desfibrilador automático implantable (DAI)
Cáncer
Oncología
Abstract
Introduction and Objectives

implantable cardiac defibrillator (ICD) has been established as a therapy for malignant ventricular arrhythmias in patients at high risk of suffering them.

Some studies suggest a possible relationship between the development of cancer and some prosthetic materials. Likewise, some investigations describe a higher incidence of cancer in patients with an ICD that suggest a potential relationship.

Methods

Retrospective cohort study of patients that underwent implantation of an ICD in the Complejo Hospitalario de Navarra between 2000 and 2016. The follow-up finished in June 2018.

Sociodemographic, comorbidities and oncological data was analysed. Cancer incidence rates were estimated and compared with the general population data and with data of a cohort of patients with reduced LVEF heart failure. Risk of cancer models were adjusted by competitive risk models.

Results

497 patients were included, mostly male (89.1%), with a mean age of 59.98 (14.98) years and a proportion of smokers of 67.6% and of ischaemic heart disease of 51.6%. The cancer incidence rate in the sample was 1230.9 per 100.000 person-year. In our study, features associated with cancer were older age, higher tobacco use and ischaemic cardiopathy.

Conclusions

In our sample of ICD carriers the incidence of cancer is high. This finding mainly seems to be related to tobacco usage and higher age.

Keywords:
Implantable cardiac defibrillator (ICD)
Cancer
Oncology

Article

These are the options to access the full texts of the publication Medicina Clínica
Subscriber
Subscriber

If you already have your login data, please click here .

If you have forgotten your password you can you can recover it by clicking here and selecting the option “I have forgotten my password”
Subscribe
Subscribe to

Medicina Clínica

Purchase
Purchase article

Purchasing article the PDF version will be downloaded

Price 19.34 €

Purchase now
Contact
Phone for subscriptions and reporting of errors
From Monday to Friday from 9 a.m. to 6 p.m. (GMT + 1) except for the months of July and August which will be from 9 a.m. to 3 p.m.
Calls from Spain
932 415 960
Calls from outside Spain
+34 932 415 960
E-mail
Article options
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos