metricas
covid
Buscar en
Radiología
Toda la web
Inicio Radiología Las bases de la interpolación en la tomografía espiral: una explicación para ...
Journal Information
Vol. 44. Issue 3.
Pages 89-101 (January 2002)
Share
Share
Download PDF
More article options
Vol. 44. Issue 3.
Pages 89-101 (January 2002)
Las bases de la interpolación en la tomografía espiral: una explicación para radiólogos*
The bases for the use of interpolation in helical computed tomography: an explanation for radiologists
Visits
9156
José María García-Santos
,1
Corresponding author
jgarcia@hmmg.insalud.es

Correspondencia: JOSÉ MARÍA GARCÍA-SANTOS. Servicio de Radiodiagnóstico. HGU «Morales Meseguer». C/. Marqués de los Vélez, s/n. 30008
, Jorge Cejudo**
* Servicio de Radiodiagnóstico, Hospital General Universitario «J.M.a Morales Meseguer». Murcia.
** Marconi Medical Systems.
This item has received
Article information

A diferencia de la tomografía computarizada (TC) convencional, la TC espiral (TCE) necesita la aplicación de interpoladores para conse-guir la reconstrucción de la imagen. Esto se debe a que las proyeccio-nes de las que se sirve el ordenador no están situadas en el mismo pla-no. Desde el comienzo de la aplicación de la TCE, diversos interpola-dores han sido diseñados con el fin de mantener el grosor de la sección reconstruida lo más próximo posible al del grosor del haz de rayos X. La intención de este artículo es discutir el funcionamiento de estos in-terpoladores para resaltar las ventajas y considerar los inconvenientes que la aplicación de los interpoladores curvos de alto orden pueden te-ner frente a los interpoladores lineales estándar.

Palabras clave:
Tomografía computarizada espiral
Interpolador lineal de 180°
Interpolador de alto orden
Perfil de sensibilidad del corte
Volumen parcial

In contrast to conventional computed tomography (CT), helical CT requires the application of interpolators to achieve image reconstruction. This is because the projections processed by the computer are not situated in the same plane. Since the introduction of helical CT, a number of interpolators have been designed in the attempt to maintain the thickness of the reconstructed section as close as possible to the thickness of the X-ray beam. The purpose of this article is to discuss the function of these interpolators, stressing the advantages and considering the possible inconveniences of high-grade curved interpolators with respect to standard linear interpolators.

Key words:
Helical computed tomography
180-degree linear interpolation
high-order interpolation
slice sensitivity profile
partial volume

Article

These are the options to access the full texts of the publication Radiología
Subscriber
Subscriber

If you already have your login data, please click here .

If you have forgotten your password you can you can recover it by clicking here and selecting the option “I have forgotten my password”
Subscribe
Subscribe to

Radiología

Purchase
Purchase article

Purchasing article the PDF version will be downloaded

Price 19.34 €

Purchase now
Contact
Phone for subscriptions and reporting of errors
From Monday to Friday from 9 a.m. to 6 p.m. (GMT + 1) except for the months of July and August which will be from 9 a.m. to 3 p.m.
Calls from Spain
932 415 960
Calls from outside Spain
+34 932 415 960
E-mail
Article options
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos