metricas
covid
Buscar en
Radiología (English Edition)
Toda la web
Inicio Radiología (English Edition) Spectral CT in Emergency
Journal Information
Vol. 65. Issue S1.
Pages S109-S119 (March 2023)
Visits
218
Vol. 65. Issue S1.
Pages S109-S119 (March 2023)
Full text access
Spectral CT in Emergency
TC espectral en la urgencia
Visits
218
Helena Cigarrán Sexto
Corresponding author
hcigarran@msn.com

Corresponding author.
, Juan Calvo Blanco, Gemma Fernández Suárez
Hospital Universitario Central de Asturias, Oviedo, Asturias, Spain
This item has received
Article information
Abstract
Full Text
Bibliography
Download PDF
Statistics
Figures (5)
Show moreShow less
Special issue
This article is part of special issue:
Vol. 65. Issue S1
More info
Abstract

Spectral CT technology is based on the acquisition of CT images with X-ray at 2 different energy levels which makes possible to distinguish between materials with different atomic numbers using their energy-dependent attenuation, even if those materials have similar density at conventional CT.

This kind of technology has gained wide application due to the innumerable uses of their post-processing techniques, including virtual non-contrast images, iodine maps, virtual mono-chromatic images or mixed images without increasing radiation dose.

There are several applications of spectral CT in Emergency Radiology that help in the detection, diagnosis and management of various pathologies such as differentiate haemorrhage from the underlaying causative lesion, diagnosis of pulmonary embolisms, demarcation of abscess, characterization of renal stones or reduction of artifacts.

The purpose of this review is to provide the emergency radiologist a brief description of the main indications for spectral CT.

Keywords:
X-rays
Computed tomography
Emergency
Dual energy
Resumen

La TC espectral se basa en la adquisición de imágenes de TC con rayos X a 2 niveles de energía distintos, lo que hace posible la diferenciación de los distintos materiales que presentan diferente número atómico. Esto es debido a que estos materiales presentan diferente atenuación con los distintos niveles de energía empleados, incluso aunque su atenuación sea similar a la de la TC convencional.

Este tipo de tecnología se ha generalizado debido a las importantes ventajas que ofrecen sus técnicas de posprocesado, incluyendo las imágenes sin contraste virtual, mapas de yodo, imágenes virtuales monoenergéticas o reconstrucciones mixtas, todo ello sin aumentar la dosis de radiación.

La TC espectral tiene múltiples aplicaciones en la radiología de urgencias que permiten una mejora en la detección, el diagnóstico y el manejo de distintas enfermedades.

El objetivo de esta revisión es describir brevemente las principales indicaciones de la TC espectral en urgencias.

Palabras clave:
Rayos X
Tomografía computarizada
Emergencia
Energía dual
Full Text
Concept, forms of acquisition and post-processing of CT studies with spectral energy

Spectral CT technology enables greater differentiation of materials than conventional CT, based on the analysis of information from the use of X-rays with different energy levels. There are materials that have different relative absorption of X-rays emitted with different energy levels, and this makes it possible to distinguish between structures with similar density, but different elemental composition.

One subtype of spectral energy is dual-energy CT, which specifically refers to the use of two energy levels. It is the most widely used form of spectral energy in clinical practice1.

The attenuation of materials essentially depends on photoelectric absorption and the Compton effect. Photoelectric absorption is proportional to (Z/E)2, where Z is the atomic number and E is the energy of the photon. As the photon energy increases, the interaction decreases and Compton scattering, which is practically constant for different energies, becomes dominant3. At low voltages, the photoelectric effect predominates in elements with a high atomic number, such as calcium or iodine, which means an increase in CT attenuation.

Many different studies have shown that, overall, the radiation dose in state-of-the-art spectral equipment is similar to or even lower than conventional studies, although it does depend on the type of CT and the anatomical region studied3–7. Moreover, the use of virtual non-contrast (VNC) images will make it possible to reduce the dose in relation to protocols that include phases without contrast.

Spectral energy can be obtained through the use of different technologies:

  • -

    Dual-source CT, consisting of two X-ray tubes placed perpendicular to each other with different kV, usually 80 and 140kV, but which can be independently adjusted for optimal contrast. Each tube has its own detector that works simultaneously. The advantage is essentially that there is no temporal discrepancy, and the main limitation is the small field of view of the second tube because of having to accommodate two tubes and two detectors within the gantry. A Somatom Definition Flash scanner (Siemens Healthineers) was used to conduct this study.

  • -

    CT with rapid voltage switching: a single X-ray tube is used which switches from 80 to 140kV in less than 0.2ms using a single detector. It has high temporal resolution with reduced spectral resolution due to the fact that the voltage cannot be modulated.

  • -

    CT with twin-beam filtration: it uses a single X-ray tube with a filter split into two parts, composed of gold and tin, which achieves spectral separation into high- and low-energy beams. It is less expensive and the filter can be placed in a conventional CT. The main disadvantages are limited spectral separation and the need for higher tube power due to filtering of the X-ray beam8.

  • -

    CT with layer detector: it has a single tube with polychromatic spectrum and a detector with two layers of different materials. Low energies are detected in the first layer of the detector and those energies capable of passing through it are detected in the deeper layer. As spectral separation is performed at the detector level, there is perfect temporal and spatial resolution with a larger field of view than dual-source CT, but with lower spectral resolution9,10.

  • -

    CT with sequential acquisition: two consecutive scans modifying the tube voltage. This was the first technological approach to dual energy. One limitation is that the different energy levels are not acquired at the same time, so the study takes longer and there may be changes in the arrangement of the different anatomical structures8,11.

  • -

    Photon-counting CT: multi-energy images are obtained using a photon-counting detector, which quantifies small photon interactions to subsequently transform them into electrical energy, proportional to the magnitude of the incident ray. This electrical energy is analysed and classified into different bands based on specific energy thresholds8.

There are various ways of post-processing the images obtained with dual energy with different clinical applications (Table 1). The types of post-processing are common to all technologies, but their names vary depending on the technology used and the manufacturer.

  • -

    Mean reconstructions: images with an appearance similar to those obtained with a CT performed at 120kV. They are obtained by combining the source images acquired at 80kV and at 140kV, which can also be viewed independently.

  • -

    The maps of specific materials are obtained by detecting or estimating the basic materials (the most common are water and iodine) to later make a representation of their distribution.

  • -

    The subtracted iodine/water can be presented as pure maps or superimposed on grey-scale images, enabling a qualitative and quantitative analysis of the presence of these substances.

  • -

    Decomposition of the value of any voxel in the contribution of each of its components allows materials to be subtracted. Removal of iodine produces VNC images similar to CT without contrast administration. Calcium removal provides virtual non-calcium images (VNCa).

  • -

    Virtual monoenergetic images (VMI) allow the HU of each tissue to be simulated at a single energy level, which can range from 40 to 200keV. The use of images with low kilovoltage highlights structures that contain iodine, while in those with high kilovoltage the presence of iodine is attenuated and metal artefacts are reduced12,13.

  • -

    Z effective (Zeff) number maps make it possible to obtain colour images based on the atomic number of the materials. In enhanced masses it aids the diagnosis, and in kidney stones a low atomic number helps guide uric acid calculation14,15.

  • -

    X-map: this is a virtual map of grey matter that can differentiate between cerebral parenchyma and water, facilitating the detection of cerebral oedema16,17.

  • -

    Other widely-used reconstructions, such as fat fraction mapping or quantitative iron mapping, have fewer applications in medical emergencies.

Table 1.

Spectral CT applications.

Algorithm    Clinical applications 
Based on the material  Material differentiation  Differentiation of nephrolithiasis according to the atomic number 
  Subtraction of materials  Differentiation between contrast and haemorrhage, since both have similar attenuation values 
    Virtual non-contrast imaging: identifies and removes iodine from voxels, avoiding having to perform a non-contrast phase 
    Virtual non-calcium imaging: identifies and removes calcium from bone to assess the bone marrow 
    Removal of bone on CT angiography: identification and removal of bone, allowing better visualisation of the vessels with contrast 
    Removal of calcified atherosclerotic plaque: better visualisation of the vessel lumen in the maximum intensity projection 
  Detection of iodine  Differentiation between a solid nodule and a haemorrhagic cyst in dense kidney lesions 
    Differentiation between soft and tumour thrombus 
    Identification of bowel ischaemia 
    Detection of active bleeding 
    Differentiation of bowel content from iodine extravasation 
  Fat/iron quantification  Quantitative evaluation of fatty liver disease and haemochromatosis 
Based on the energy  Low-keV VMIEnhance the presence of iodinated contrast 
  Detection of cholesterol gallstones 
  High keV VMI  Reduction of metal artefacts 
  Zeff mapsDetection of pulmonary thromboembolism 
  Demonstration of inflammatory activity 
  Detection of cholesterol gallstones 

VMI: virtual monoenergetic images; Zeff: effective atomic number.

Applications of spectral CT in emergency radiologyGeneral applicationsPotentiation of the effect of iodinated contrast

Spectral energy makes it possible to increase vascular enhancement by increasing iodine attenuation in low-keV VMI reconstructions. This means that a smaller volume of contrast can be used, and we can assess small-lumen vessels and improve the diagnostic quality of poorly opacified studies18.

Reduction of artefacts

Metals produce partial or complete attenuation of low-energy X-rays, causing hardening artefacts. VMI with high keV avoid contamination deriving from attenuated rays that do not reach the detector, thereby causing artefacts, but entail a loss of contrast resolution between the different tissues19.

Head and neckDetection of lesions

VMI help to detect low-density images or haemorrhages on non-contrast CT, although the energy level depends on the location of the lesion. Lesions which are hypodense in white matter or hyperdense in grey matter are best detected at low keV20.

Furthermore, X maps increase the sensitivity to detect oedema induced by acute cerebral ischaemia, allowing early detection of ischaemic changes and aiding selection of patients who are candidates for mechanical thrombectomy16.

Post-traumatic haemorrhage

An increase in density on CT can be caused by calcium or blood. The use of VNCa maps helps increase diagnostic certainty. Bone subtraction techniques enable small subdural haemorrhages or peripheral contusions to be identified by removing adjacent dense bone21.

Spontaneous bleeding

Spontaneous intraparenchymal haemorrhages may be secondary to underlying lesions (vascular, neoplastic or infectious).

The use of intravenous (IV) contrast-enhanced spectral CT enables identification of any underlying lesion within an intraparenchymal haematoma by detecting areas of iodine uptake (Fig. 1A)19,22.

Figure 1.

A) Secondary haemorrhage. Non-contrast CT with left temporal haematoma (green circle) (1). Mean CT with IV contrast showing a slight increase in density (2). Iodine map confirming an underlying neoplastic lesion as the source of bleeding (3). B) Haemorrhagic transformation. Mean CT in a patient undergoing mechanical thrombectomy with subacute ischaemic lesion in the left basal ganglia with two hyperdense areas in the lentiform nucleus (blue circle) (1). The virtual non-contrast map shows hyperdensity in the lentiform nucleus, so it can be ruled out that it is contrast, in fact corresponding to bleeding foci (2). The iodine map does not show contrast enhancements (3). C) Contrast retention. Mean CT with right temporal/parietal hyperdensity (red circle) (1). Virtual non-contrast CT does not show hyperdensities (2). The iodine map shows a temporal/parietal uptake representing contrast retention (3).

(0.8MB).
Post-thrombectomy

In follow-up after mechanical thrombectomy, a common finding is increased attenuation in the ischaemic territory, which may be secondary to extravasation of contrast due to disruption of the blood-brain barrier or haemorrhagic transformation.

Dual energy makes it possible to determine the origin of the hyperdensity with high sensitivity and specificity. If the origin is haemorrhagic, only hyperdensity persists on VNC maps, while contrast retention only remains visible on iodine maps23. The overall analysis of both maps will make it possible to quantify each component in the event that there is a mixture of the two (Fig. 1B and C).

Venous thrombosis

As it is not enhanced by contrast, the thrombus is not represented on the iodine map, but low-keV VMI increase the difference in density between the thrombus and the opacified sinus, increasing sensitivity24.

Cervical spine abscesses

Spectral energy enables more accurate delineation of the extent of the collection and adjacent inflammation by using Zeff maps and low-keV VMI. In addition, demonstration of proximity to vascular structures may be beneficial to prevent bleeding in case of the need for surgical drainage19.

ChestPulmonary thromboembolism

The use of Zeff and iodine maps increases the sensitivity for the detection of pulmonary thromboembolism, as it allows the simultaneous study of arterial filling defects, which would be shown in a different colour, and areas of hypoperfusion, visible as triangular-shaped iodine uptake defects in the parenchyma. This is particularly relevant in the diagnosis of small peripheral emboli which, without treatment, could evolve into pulmonary hypertension25.

In cases of non-occlusive pulmonary embolism, iodine maps can demonstrate normal lung perfusion distal to partial filling defects (Fig. 2).

Figure 2.

Pulmonary thromboembolism. CT angiogram of the pulmonary arteries with suspected filling defect in the subsegmental artery (white arrow) (1). Iodine map showing a peripheral perfusion defect consistent with the thrombus (white arrow) (2). Iodine map associated with effective atomic number (Zeff) map showing the different composition of the thrombosed artery (white arrow) (3).

(0.19MB).
AbdomenDetection of active bleedingThis principle is applicable to any anatomical region

Spectral energy makes it possible to dispense with the non-contrast phase, as VNC reconstructions are available, and so reduces radiation dose and acquisition time. Iodine maps and VMI at low keV help to detect small volumes of extravasated contrast, increasing the sensitivity for the detection of active bleeding, with greater precision when determining the origin, which can be masked by the presence of adjacent dense clots (Fig. 3A)26.

Figure 3.

A) Active bleeding. Abdominal CT in the arterial phase showing hyperdensity in the descending colon (red arrow), which could correspond to active bleeding (1). In the mean portal phase there is no evident increase in contrast extravasation (red arrow), which makes the diagnosis of active bleeding suspect (2). The virtual non-contrast reconstruction shows disappearance of the hyperdensity (red arrow) (3). The iodine map shows that the hyperdensity corresponds to extravasated contrast. The findings of the virtual non-contrast map and the iodine map mean the diagnosis of active bleeding can be made with certainty (4). B) Neoplastic lesion with an adjacent clot. Abdominal CT in mean portal phase. Extensive occupation of the bladder by a high-density material (1). Iodine map shows a solid contrast-enhancing lesion (yellow arrow) attached to the right posterior wall of the bladder in association with a neoplasia. The other dense areas correspond to a voluminous clot (2). Low-keV VMI, where we enhanced the contrast uptake areas of the neoplasia (yellow arrow) (3).

(0.36MB).
Assessment of contrast enhancementDifferentiating clots from an underlying neoplastic lesion

As in spontaneous cerebral haemorrhages, in other anatomical regions the presence of blood makes it difficult to detect underlying contrast-enhancing lesions, as both are hyperdense and have similar attenuation values. Analysis of the iodine maps and VMI at low keV makes it possible to differentiate between each component (Fig. 3B). Wunderlich syndrome or frank haematuria secondary to a bladder tumour are examples of its utility19.

Venous thrombosis

Iodine maps and quantification, as well as the assessment of the VMI at low keV, make it possible to detect the presence of contrast in tumour thrombi, a fundamental criterion for their differentiation from soft thrombi27. In patients with hepatocellular carcinoma, an iodine quantification greater than 0.9mg/mL differentiates between the two lesions with high sensitivity and specificity28.

Bowel ischaemia

Bowel ischaemia is caused by decreased or absent blood flow in a loop26. The most specific sign is the absence of or decrease in enhancement of the bowel wall, which may go unnoticed in the initial phases of a conventional CT. Both iodine maps and low-keV VMI facilitate early detection of low mural uptake, either by visual qualitative analysis or by absolute (calculation of the iodine density in the hypoperfused loop) and relative (comparing the iodine densities of the hypoperfused loop and the normal loop) quantitative analysis, more suitable because it is not influenced by haemodynamic factors (Fig. 4A)29.

Figure 4.

A) Bowel ischaemia. Abdomen CT in mean portal phase in the coronal plane showing marked low uptake of the bowel loops on the left flank with free fluid (1). The same image with virtual monoenergetic reconstructions at low keV where the low uptake is more evident (2). The iodine map shows a much lower iodine density in loops with low uptake (0.7mg/mL) than in non-diseased loops (4.1mg/mL) (3). B) Acute pancreatitis. Oedema of the pancreas and extensive peripancreatic inflammatory changes (1). The iodine map identifies an area of poor enhancement in the tail of pancreas (blue circle), findings consistent with necrosis in the context of acute necrotising pancreatitis (2).

(0.56MB).

In this context, the presence of mural hyperdensity may mean haemorrhage or hypervascularisation due to reperfusion. The distinction can be made by analysing the VNC images30.

Inflammatory bowel disease

Analysis of a spectral CT performed in the portal phase with low-keV VMI makes it possible to increase the differences in attenuation between inflamed and normal loops, while the iodine and Zeff maps quantify the difference in iodine uptake, relevant when establishing disease activity19.

Pancreatic disease

CT is the modality of choice in patients with pancreatitis who require an imaging technique for assessment. The use of iodine maps increases sensitivity for detecting glandular inflammation, as the iodine density significantly decreases (less than 2.1mg/mL) compared to the normal pancreas, while non-perfused necrotic areas can also be distinguished. Low-keV VMI provide better definition of complex collections and make it easier to detect vascular complications such as thrombosis or pseudoaneurysms (Fig. 4B)31.

As in other organs such as the liver or spleen, low-keV VMI make it easier to detect small lacerations, which are difficult to identify in the pancreas because acquisition is usually in the venous phase and not in the late arterial phase31,32.

Small pancreatic tumours can also be difficult to distinguish on conventional CT. Low-keV VMI, Zeff or iodine maps allow a better definition of pancreatic hypo- or hypervascular lesions, facilitating the detection and diagnosis of cancer.

Cholecystitis

Although ultrasound is the most sensitive technique in the assessment of gallbladder disease, CT is also common in certain cases. Portal phase spectral CT enables quantitative analysis of gallbladder wall enhancement with high sensitivity. Low-energy VMI and iodine maps are useful for detecting wall hyperenhancement in acute cholecystitis or low uptake and focal areas of non-enhancement associated with necrosis in gangrenous cholecystitis (Fig. 5)33.

Figure 5.

Gangrenous cholecystitis. Abdomen CT in portal phase showing diffuse thickening of the gallbladder wall with cholelithiasis and peri-vesicular oedema (blue circle) in association with acute cholecystitis (1). Iodine map showing areas of decreased uptake of the gallbladder wall (blue arrows) secondary to necrosis associated with gangrenous cholecystitis (2). Low-keV VMI where patchy areas are best identified without contrast (blue arrows) (3). Surgical specimen where necrotic patchy areas can be seen (4).

(0.19MB).
Pyelonephritis and renal infarction

Pyelonephritis and renal infarction can have a similar clinical presentation, and both are identified as hypodense images on portal-phase CT. The VMI show better delimitation of the lesions, while the iodine and Zeff maps quantify the presence of iodine, which is decreased in pyelonephritis and absent in renal infarction19.

Detection and characterisation of lithiasisNephrolithiasis

CT is the most sensitive test for detecting kidney stones, their size and location, as well as complications such as dilation of the excretory tract and renal or peri-renal oedema.

Spectral CT makes it possible to characterise calculi based on their composition with a sensitivity of 90–100 %. Uric acid stones attenuate high-energy radiation more due to the presence of elements with low atomic number, while calcium oxalate or calcium phosphate stones attenuate lower-energy radiation more because they are made up of elements with higher atomic number. VNC reconstructions facilitate the detection of nephrolithiasis in abdominal studies performed with IV contrast, and ureteral or bladder lithiasis when the excretory tract is opacified with contrast19.

Cholelithiasis and choledocholithiasis

Detection of gallstones on CT depends on the composition and size of the stone. Cholesterol gallstones have a density similar to bile and are not detectable on conventional CT, but they can be detected using spectral energy.

The attenuation curve of fat is inverse to that of iodine, so cholesterol gallstones are hypoattenuating in low-keV VMI and hyperattenuating in high keV VMI. Calcified stones are best detected on VNC reconstructions.

Zeff maps enable differentiation of the calculus from the surrounding fluid in the case of gallstone ileus19,26.

Incidental lesions

Spectral energy makes it possible to characterise incidental lesions, which very often cannot be characterised in a single-phase scan.

This is common with adrenal nodules. VNC reconstructions allow their density to be determined; as this may be slightly higher than in true non-contrast scans, there is a risk of classifying more lesions as indeterminate. However, the diagnosis of adenoma can be made with certainty using a threshold below 10 HU34. The finding of dense renal cysts is also common; absence of uptake can be demonstrated on the iodine maps.

This avoids the need to repeat tests, with the consequent reduction in healthcare costs and radiation dose.

Musculoskeletal systemAcute fractures

The oedema or haemorrhage in the bone marrow that accompanies acute fractures is not identifiable on conventional CT because the cancellous bone obscures visualisation of the marrow. With spectral CT we can perform VNCa, which subtracts the cancellous bone, so we can then analyse the bone marrow density and attenuation will be higher if there is oedema or haemorrhage. This application makes it possible to diagnose subtle fractures or date the age of a vertebral compression fracture19,26.

Uric acid deposits

The same principle that enables the composition of nephrolithiasis to be characterised in abdominal scans can be applied to other fields, such as the detection of uric acid deposits in musculoskeletal studies, making it possible to diagnose gouty arthritis19.

Limitations

As well as the limitations inherent in each type of acquisition technology, spectral CT generates a larger number of images, which then require more interpretation time and greater storage capacity in PACS.

Conducting studies with dual energy does not increase room occupation time, but the systematic review of the different reconstructions increases the workload for the radiologist.

In addition, dual energy produces a series of artefacts (Table 2) that have to be recognised and corrected by the radiologist to avoid diagnostic errors.

Table 2.

Limitations of spectral CT.

When does it happen?  What causes it?  What happens?  Possible solution 
During the acquisition  High body mass index  NoiseInadequate decomposition of materialsPhoton starvation artefact  Maximum weight limit: 118−127 kgTransverse diameter limit: 38−46 cmChange in acquisition variables. In dual-source CT: increase the low-kilovoltage beam from 80 to 100 kVp 
  Patient position in the gantry  Lack of spectral information as outside the field of view  In dual-source CT the maximum field of view is 26−35.5cm. Proper placement in the gantry according to the anatomical area to be studied 
  Placement of the arms  Beam-hardening artefact  Arms placed above or below the shoulders according to the region to be studied: head-neck/chest-abdomen 
  Contrast medium density  Significant increase in contrast density in low-kilovoltage imagesBloomingInadequate iodine suppression on virtual non-contrast images  Reducing the concentration of the oral or intravenous contrast administered 
  Inadequate temporal resolution  Spectral bias: on CT based on the X-ray source, there is a time lag for obtaining each voxel with dual energy  Increase tube rotation speed 
During the post-processing  Low-energy photon counting  Hyperdense foci on iodine mapsFalse urate deposits  Adequate reconstruction filterAppropriate selection of attenuation threshold 
  Inadequate selection of threshold  False positives/negativesInadequate separation of materialsIncreased noise  Adequate selection of the material decomposition threshold taking into account the disease to be studied and tube voltageAdjustment of the voltage pairs predefined by the manufacturer based on clinical experience: 80/140 or 100/140kVp 
During the visualisation  Inadequate window  Blooming in low-kilovoltage imagesFalse enhancementVisualisation of iodine in subcutaneous fat or air  Window level and width should be adjusted using fat, air and fluid as a model 
Practical recommendations

As it is still a relatively recent and expensive technology, the availability of this equipment tends to be limited, hence not all urgent studies can be performed using spectral CT.

At our hospital, at present, we use dual-energy CT for all scans that would require a non-contrast phase (mesenteric ischaemia, suspected active bleeding and gastrointestinal bleeding), those where we need assessment of organ perfusion (pulmonary thromboembolism, pancreatitis, suspected gangrenous cholecystitis on ultrasound), contrast studies in spontaneous cerebral haemorrhages, follow-up after mechanical thrombectomy, for nephrolithiasis not visualised on ultrasound needing characterisation, and for peripheral vascular studies. The study of these patients always includes a review of the VNC reconstructions, VMI and iodine maps. The use of other reconstructions is less common (Zeff maps, VNCa), reserved only for specific cases and depending on the disease studied.

We automatically send the high- and low-kV source images to the PACS, as well as the mean reconstructions that would allow the study to be visualised without the need for post-processing. Recovery of the source images from the specific workstations means we can defer any post-processing. The rest of the post-processed images, as well as the most representative images of the disease findings identified, are sent to the PACS at the discretion of the radiologist34.

Conclusion

Although the concept of spectral power is not recent, technological advances and greater availability have made it possible to expand its use in emergency scans. There are now multiple applications of spectral CT in the detection, diagnosis and management of different acute diseases, a list of indications that continues to grow with the consequent improvement in diagnostics.

Acronyms

VMI: virtual monoenergetic images.

VNC: virtual non-contrast.

VNCa: virtual non-calcium.

Zeff maps: effective atomic number maps.

PACS: Picture Archiving and Communication System.

Ethical considerations

The consent of the Ethics Committee was not necessary because the studies were conducted for clinical indication and not for research purposes. Consent was obtained from the patients to perform the imaging studies. None of the images shows data that could identify the patients.

Authorship

  • 1

    Responsible for the integrity of the study: HCS, JCB and GFS.

  • 2

    Study conception: HCS, JCB and GFS.

  • 3

    Study design: HCS, JCB and GFS.

  • 4

    Data collection: HCS, JCB and GFS.

  • 5

    Data analysis and interpretation: HCS, JCB and GFS.

  • 6

    Statistical processing: HCS, JCB and GFS.

  • 7

    Literature search: HCS, JCB and GFS.

  • 8

    Drafting of the article: HCS, JCB and GFS.

  • 9

    Critical review of the manuscript with intellectually relevant contributions: HCS, JCB and GFS.

  • 10

    Approval of the final version: HCS, JCB and GFS.

Conflicts of interest

The authors declare that they have no conflicts of interest.

References
[1]
A. So, S. Nicolaou.
Spectral computed tomography: Fundamental principles and recent developments.
Korean J Radiol, 22 (2021), pp. 86-96
[2]
T. Henzler, C. Fink, S.O. Schoenberg, U.J. Schoepf.
Dual-energy CT: Radiation dose aspects.
AJR Am J Roentgenol, 199 (2012), pp. S16-S25
[3]
R.A. Parry, S.A. Glaze, B.R. Archer.
The AAPM/RSNA physics tutorial for residents. Typical patient radiation doses in diagnostic radiology.
Radiographics, 19 (1999), pp. 1289-1302
[4]
A.M. Tawfik, J.M. Kerl, A.A. Razek, R.W. Bauer, N.E. Nour-Eldin, T.J. Vogl.
Image quality and radiation dose of dual-energy CT of the head and neck compared with a standard 120-kVp acquisition.
AJNR Am J Neuroradiol, 32 (2011), pp. 1994-1999
[5]
R. Forghani, B. de Man, R. Gupta.
Dual-energy computed tomography: Physical principles, approaches to scanning, usage, and implementation: Part 1.
Neuroimaging Clin N Am, 27 (2017), pp. 371-384
[6]
R. Forghani, B. de Man, R. Gupta.
Dual-energy computed tomography: Physical principles, approaches to scanning, usage, and implementation: Part 2.
Neuroimaging Clin N Am, 27 (2017), pp. 385-400
[7]
F. Van Ommen, H.W.A.M. de Jong, J.W. Dankbaar, E. Bennink, T. Leiner, A.M.R. Schilham.
Dose of CT protocols acquired in clinical routine using a dual-layer detector CT scanner: A preliminary re-port.
Eur J Radiol, 112 (2019), pp. 65-71
[8]
E. Alavandar, V.K. Arunachalam, N. Narappulan, G.S. Mahadevan, R. Kashyap, P. Mehta, et al.
Principles and available hardware in DECT.
Journal Gastrointestinal and Abdominal Radiology, 01 (2022), pp. 1-74
[9]
R. Forghani, B. de Man, R. Gupta.
Dual-energy computed tomography: Physical principles, approaches to scanning, usage, and implementation: Part 1.
Neuroimaging Clin N Am, 27 (2017), pp. 371-384
[10]
T.R. Johnson.
Dual-energy CT: General principles.
AJR Am J Roentgenol, 199 (2012), pp. S3-8
[11]
S. Aran, K.W. Shaqdan, H.H. Abujudeh.
Dual-energy computed tomography (DECT) in emergency radiology: Basic principles, techniques, and limitations.
Emerg Radiol, 21 (2014), pp. 391-405
[12]
C.H. McCollough, K. Boedeker, D. Cody, X. Duan, T. Flohr, S.S. Halliburton, et al.
Principles and applications of multienergy CT: Report of AAPM Task Group 291.
Med Phys., 47 (2020), pp. e881-e912
[13]
A. Agostini, A. Borgheresi, A. Mari, C. Floridi, F. Bruno, M. Carotti, et al.
Dual-energy CT: Theoretical principles and clinical applications.
Radiol Med, 124 (2019), pp. 1281-1295
[14]
P. Rajiah, A. Parakh, F. Kay, D. Baruah, A.R. Kambadakone, S. Leng.
Update on multienergy CT: Physics, principles, and applications.
Radiographics, 40 (2020), pp. 1284-1308
[15]
S.Z. Adam, A. Rabinowich, R. Kessner, A. Blachar.
Spectral CT of the abdomen: Where are we now?.
Insights Imaging, 12 (2021), pp. 138
[16]
M.F. Mohammed, O. Marais, A. Min, D. Ferguson, S. Jalal, F. Khosa, et al.
Unenhanced dual-energy computed tomography: Visualization of brain edema.
Invest Radiol, 53 (2018), pp. 63-69
[17]
Y. Kaichi, F. Tatsugami, Y. Nakamura, Y. Baba, M. Iida, T. Higaki, et al.
Improved differentiation between high- and low-grade gliomas by combining dual-energy CT analysis and perfusion CT.
Medicine (Baltimore), 97 (2018),
[18]
S. Aran, L. Daftari Besheli, M. Karcaaltincaba, R. Gupta, E.J. Flores, H.H. Abujudeh.
Applications of dual-energy CT in emergency radiology.
AJR Am J Roentgenol, 202 (2014), pp. W314-24
[19]
B. Demirler Simsir, E. Danse, E. Coche.
Benefit of dual-layer spectral CT in emergency imaging of different organ systems.
Clin Radiol, 75 (2020), pp. 886-902
[20]
S. Lennartz, K.R. Laukamp, V. Neuhaus, N. Große Hokamp, M. Le Blanc, V. Maus, et al.
Dual-layer detector CT of the head: Initial experience in visualization of intracranial hemorrhage and hypodense brain lesions using virtual monoenerget-ic images.
Eur J Radiol, 108 (2018), pp. 177-183
[21]
N. Naruto, H. Tannai, K. Nishikawa, K. Yamagishi, M. Hashimoto, H. Kawabe, et al.
Dual-energy bone removal computed tomography (BRCT): Preliminary report of efficacy of acute intracranial hemorrhage detection.
Emerg Radiol, 25 (2018), pp. 29-33
[22]
S.J. Kim, H.K. Lim, H.Y. Lee, C.G. Choi, D.H. Lee, D.C. Suh, et al.
Dual-energy CT in the evaluation of intracerebral hemorrhage of unknown origin: Differentiation between tumor bleeding and pure hemorrhage.
AJNR Am J Neuroradiol, 33 (2012), pp. 865-872
[23]
M.P. Tijssen, P.A. Hofman, A.A. Stadler, W. van Zwam, R. de Graaf, R.J. van Oostenbrugge, et al.
The role of dual energy CT in differentiating between brain haemor-rhage and contrast medium after mechanical revascularisation in acute ischaemic stroke.
Eur Radiol, 24 (2014), pp. 834-840
[24]
J. Weiss, C. Schabel, A.E. Othman, G. Bier, K. Nikolaou, F. Bamberg, et al.
Impact of dual-energy CT post-processing to differentiate venous thrombosis from iodine flux artefacts.
Eur Radiol, 28 (2018), pp. 5076-5082
[25]
A. Otrakji, S.R. Digumarthy, R. lo Gullo, E.J. Flores, J.A. Shepard, M.K. Kalra.
Dual-energy CT: Spec-trum of thoracic abnormalities.
Radiographics, 36 (2016), pp. 38-52
[26]
J.R. Wortman, J.W. Uyeda, U.P. Fulwadhva, A.D. Sodickson.
Dual-energy CT for abdominal and pelvic trauma.
Radiographics, 38 (2018), pp. 586-602
[27]
M.D. Agrawal, D.F. Pinho, N.M. Kulkarni, P.F. Hahn, A.R. Guimaraes, D.V. Sahani.
Oncologic applications of dual-energy CT in the abdomen.
Radiographics, 34 (2014), pp. 589-612
[28]
G. Ascenti, C. Sofia, S. Mazziotti, S. Silipigni, T. d’Angelo, S. Pergolizzi, et al.
Dual-energy CT with iodine quantification in distinguishing between bland and neoplastic portal vein thrombosis in patients with hepatocellular carcinoma.
Clin Radiol, 71 (2016), pp. 938.e1-938.e9
[29]
P.D.M. Lourenco, R. Rawski, M.F. Mohammed, F. Khosa, S. Nicolaou, P. McLaughlin.
Dual-energy CT Iodine Mapping and 40-keV monoenergetic applications in the diagnosis of acute bowel ischemia.
AJR Am J Roentgenol, 211 (2018), pp. 564-570
[30]
H. Cigarrán Sexto, J. Clavo Blanco.
Isquemia visceral y mesentérica.
Tratado de Radiología de Urgencias, pp. 359-372
[31]
D. Mastrodicasa, A. delli Pizzi, B.N. Patel.
Dual-energy CT of the pancreas.
Semin Ultrasound CT MR, 40 (2019), pp. 509-514
[32]
J.L. Wichmann, P. Majenka, M. Beeres, W. Kromen, B. Schulz, S. Wesarg, et al.
Single-portal-phase low-tube-voltage dual-energy CT for short-term follow-up of acute pancreatitis: Evaluation of CT severity index, interobserver agreement and radiation dose.
Eur Radiol, 24 (2014), pp. 2927-2935
[33]
T. Singh, P. Gupta.
Role of dual energy computed tomography in gallbladder disease: A review.
J Gastrointestinal Abdominal Radiol ISGAR, 05 (2022), pp. 107-113
[34]
A. Parakh, C. An, S. Lennartz, P. Rajiah, B.M. Yeh, F.J. Simeone, et al.
Recognizing and minimizing artifacts at dual energy.
Radiographics, 41 (2021), pp. 509-523
Copyright © 2022. SERAM
Download PDF
Article options
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

Quizás le interese:
10.1016/j.rxeng.2022.06.003