covid
Buscar en
Revista Colombiana de Anestesiología
Toda la web
Inicio Revista Colombiana de Anestesiología Depresión respiratoria neonatal y fentanilo intratecal
Journal Information
Vol. 40. Issue 2.
Pages 100-105 (April - June 2012)
Share
Share
Download PDF
More article options
Vol. 40. Issue 2.
Pages 100-105 (April - June 2012)
Open Access
Depresión respiratoria neonatal y fentanilo intratecal
Neonatal Respiratory Depression and Intrathecal Fentanyl
Visits
8856
V.H. González Cárdenas
Corresponding author
vhgc79@yahoo.es

Autor para correspondencia: Autopista Norte No. 94-45, Bogotá, Colombia.
Médico y cirujano, anestesiólogo, epidemiólogo clínico, anestesiólogo e instructor de Anestesiología y Cuidado Crítico, Hospital Universitario de la Samaritana; docente clínico, Universidad de la Sabana; anestesiólogo, Hospital Infantil Universitario de San José; Instructor FUCS, anestesiólogo intensivista, Clínica Universitaria Colombia-Organización Sanitas; Departamento de Anestesiología, Clínica Materno Infantil, Corporación Saludcoop, Bogotá, Colombia
This item has received

Under a Creative Commons license
Article information
Resumen
Objetivo

Establecer la prevalencia de depresión respiratoria neonatal en pacientes expuestas a fentanil intratecal durante cesárea.

Métodos

Estudio Observacional Retrospectivo Analítico Tipo Corte Transversal realizado en la Clínica Materno-Infantil de la Corporación Saludcoop en pacientes llevadas a cesárea y que recibieron Fentanil intratecal para anestesia regional en los años 2007 y 2008. Desenlaces primarios: APGAR Bajo (APGAR<7) y APGAR Severo (APGAR<4).

Resultados

2165 Registros de cesáreas y fentanil intratecal con dosis media de 19,21mcg (DE=0,206mcg). Prevalencia de APGAR Bajo al nacer al minuto 01=1,77% (DE=0,63%), al minuto 05=0,11% (DE 0,163%), al minuto 10=0%; siendo estos dos últimos valores diferentes al valor del minuto 01 (ANOVA Test Scheffé p=0,031) y sin diferenciarse entre ellos (minutos 5 y 10) (ANOVA p=0,861). APGAR Severamente disminuido al nacer al minuto 1=0,059% (DE 0,058), a los minutos 5 y 10=0%. Los tres valores severamente disminuidos no presentaron diferencias estadísticamente significativas entre sí (ANOVA p=0,861).

Conclusiones

La prevalencia de Depresión Respiratoria medido con el test de APGAR al nacer es baja; el compromiso severo del APGAR presenta una tendencia a 0 en todos los minutos de su valoración; aun así es cuestionable la fiabilidad de la herramienta diagnóstica (APGAR) al existir discrepancias en el análisis con una escala mucho más sensible para el diagnóstico (Test de Silverman).

La importancia de este estudio solo radica como evaluación de prevalencia y fuente de hipótesis de investigación, no como estudio de asociación o predicción.

Palabras clave:
Anestesia de conducción
Cesárea
Prevalencia
Insuficiencia respiratoria
Abstract
Objective

To establish the prevalence of neonatal respiratory depression in patients exposed to intrathecal fentanyl during Cesarean section.

Methods

Cross-sectional Analytical Observational Retrospective Study conducted at the Mother and Child Clinic of the Saludcoop Corporation in patients undergoing C-section who received intrathecal fentanyl for regional anesthesia in 2007 and 2008. Primary endpoints: low APGAR score (APGAR<7) and severe APGAR (APGAR<4).

Results

2165 records of C-sections and intrathecal fentanyl with a mean dose of 19.21mcg (SD=0.206mcg). Prevalence of low APGAR at 1, 5 and 10 minutes was 1.77% (SD=0.63%), 0.11% (SD 0.163%), and 0%, respectively. The latter two values were different from the 1-minute value (ANOVA Scheffé Test, p=0.031) and there was no difference between them (minutes 5 and 10) (ANOVA p=0.861). Severely diminished APGAR results were, 0.059% (SD 0.058) 1 minute after birth and 0% at 5 and 10 minutes. There were no statistically significant differences between the three severely diminished values (ANOVA p=0.861).

Conclusions

The prevalence of respiratory depression measured with the APGAR test at birth is low; severely compromised APGAR shows a trend towards 0 in the different minutes of assessment. However, the reliability of the diagnostic tool (APGAR) is questionable, considering discrepancies when the analysis is done with a far more sensitive diagnostic tool (Silverman test).

The importance of this study relates only to the assessment of prevalence and its use as a source of a research hypothesis, and not as an association or prediction study.

Keywords:
Anesthesia
Conduction
Cesarean section
Prevalence
Respiratory insufficiency
Full text is only aviable in PDF
Referencias
[1.]
Resolución No. 008430 de 1993 (04 de Octubre de 1993), Ministerio de Protección Social de la República de Colombia.
[2.]
J. Littleford.
Effects on the fetus and newborn of maternal analgesia and anesthesia: a review; Obstetrical and Pediatric Anesthesia.
Can J Anesth, 51 (2004), pp. 586-609
[3.]
C.V. Smith, W.F. Rayburn, K.V. Allen, T.M. Bane, G.T. Livezey.
Influence of intravenous fentanyl on fetal biophysical parameters during labor.
[4.]
E.M. Nikkola, T.T. Kirjavainen, U.U. Ekblad, P.O. Kero, M.A. Salonen.
Postnatal adaptation after caesarean section or vaginal delivery, studied with the staticcharge-sensitive bed.
Acta Paediatr, 91 (2002), pp. 927-933
[5.]
C.M. Cowan, J.B. Kendall, P.M. Barclay, R.G. Wilkes.
Comparison of intratechal fentanyl and diamorphine in addition to bupivacaine for Caesarean section under spinal anesthesia.
Br J Anaesth, 89 (2002), pp. 452-458
[6.]
M.A. Frölich, D.J. Burchfield, T.Y. Euliano, D. Caton.
A single dose of fentanyl and midazolam prior to Cesarean section have no adverse neonatal effects.
Can J Anesth, 53 (2006), pp. 79-85
[7.]
D. Shende, G.M. Cooper, M.I. Bowden.
The influence of intrathecal fentanyl on the characteristics of subarachnoid block for caesarean section.
Anaesthesia, 53 (1998), pp. 702-710
[8.]
M.C. Kelly, U.A. Carabine, R.K. Mirakhur.
Intrathecal for diamorphine for analgesia after caesarean section.
Anaesthesia, 53 (1998), pp. 231-237
[9.]
C.O. Hunt, J.S. Naulty, A.M. Bader, M.A. Hauch, J.V. Vartikar, S. Datta, et al.
Perioperative analgesia with subarachnoid fentanil-bupivacaine for cesarean delivery.
Anesthesiology, 71 (1989), pp. 535-540
[10.]
S.D. Belzarena.
Clinical effects of intrathecally administered fentayl in patients undergoing cesarean section.
Anesth Analg, 74 (1992), pp. 653-657
[11.]
C. Mardirosoff, L. Dumont, M. Boulvain, M.R. Tramer.
Fetal bradycardia due to intrathecal opioids for labour analgesia: a systematic review.
BJOG, 109 (2002), pp. 274-281
[12.]
American Society of Anesthesiologists Task Force on Neuroaxial Opioids: Terese Horlocker (Chair) et al.
Practice Guidelines for the Prevention, Detection, and Management of Respiratory Depression Associated with Neuroaxial Administration.
Anesthesiology, 110 (2009), pp. 218-230
[13.]
C.A. Wong, B.M. Scavone, A.M. Peaceman, R.J. McCarthy, D. Pharm, J.T. Sullivan, et al.
The risk of cesarean delivery with neuroaxial analgesia given early versus late in labor.
N Engl J Med, 352 (2005), pp. 655-665
[14.]
S. Alvarez, C. Perdomo, C. Salinas, L. Garcia.
Efectos del fentanyl adicionado a Bupivacaína en anestesia peridural para operación cesárea.
Rev Colomb Anestesiol, 30 (2002), pp. 23-31
Copyright © 2012. Sociedad Colombiana de Anestesiología y Reanimación
Download PDF
Article options