covid
Buscar en
Revista Colombiana de Cardiología
Toda la web
Inicio Revista Colombiana de Cardiología Primer implante de electrodo de estimulación selectiva del haz de His en Colomb...
Journal Information
Vol. 17. Issue 3.
Pages 141-144 (May - June 2010)
Share
Share
Download PDF
More article options
Vol. 17. Issue 3.
Pages 141-144 (May - June 2010)
Open Access
Primer implante de electrodo de estimulación selectiva del haz de His en Colombia. Reporte de dos casos
First implantation of selective his bundle pacing in Colombia. Report of two cases
Visits
1958
Jorge E. Velásquez1,3, Mauricio Duque1,3,
Corresponding author
mauricioduque@une.net.co

Correspondencia: Carrera 24B No. 16-26, Medellín, Colombia.
, Jorge E. Marín V.1,2,3, Julián M. Aristizábal1,3, Luis E. Medina1,2,3, Edgardo González1,2,3, Laura Duque1,3, William Uribe1,2,3
1 Universidad CES. Medellín, Colombia
2 Clínica Medellín. Medellín, Colombia
3 Servicio de Electrofisiología - Cardiología Clínica Medellín. Universidad CES Medellín
This item has received

Under a Creative Commons license
Article information

Se conoce que la estimulación en el ápex del ventrículo derecho produce disincronía ventricular y muchas veces los pacientes desarrollan miocardiopatía dilatada, lo que ha llevado a realizar una estimulación más fisiológica. Con el reciente desarrollo tecnológico de los electrodos para la estimulación selectiva del haz de His (fisiológica), se quiere mostrar la experiencia en el implante de este tipo de electrodos en los dos primeros casos del servicio de electrofisiología de la Clínica Medellín.

Palabras clave:
estimulación fisiológica
select site
haz de His

Pacing in the right ventricular apex is known to produce ventricular dysynchrony and patients often develop dilated cardiomiopathy. For this reason, a more physiological stimulation has been performed. With the recent technological development of electrodes for selective stimulation of the His bundle, we want to show the experience of this type of implantation in the first two cases made in the electrophysiology laboratory in Medellin.

Key words:
physiological stimulation
select site
bundle of His
Full text is only aviable in PDF
Bibliografía
[1.]
B.L. Wilkoff, J.R. Cook, A.E. Epstein, H.L. Greene, A.P. Hallstrom, H. Hsia, S.P. Kutalek, A. Sharma, Dual Chamber and VVI Implantable Defibrillator Trial Investigators.
Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator: the Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial.
JAMA, 288 (2002), pp. 3115-3123
[2.]
M.O. Sweeney, A.S. Hellkamp, D.A. Ellenbogen, for the MOde Selection Trial (MOST) Investigators, et al.
Adverse effect of ventricular pacing on heart failure and atrial fibrillation among patients with normal baseline QRS duration in a clinical trial of pacemaker therapy for sinus node dysfunction.
Circulation, 107 (2003), pp. 2932-2937
[3.]
M. Anelli-Monti, H. Machler, S. Schweiger, L. Salaymeh, B. Rigler.
QRS-duration in right ventricular outflow tract (RVOT) pacing (Conference Abstract).
Europace Supplements, 7 (2005), pp. 287
[4.]
M. Anelli-Monti, H. Machler, S. Schweiger, Martin D., B. Rigler.
RVOT pacing with the Select Secure System- Clinical experience (Conference Abstract).
Europace Supplements, 7 (2005), pp. 294
[5.]
S. Saksena.
The role of multisite atrial pacing in rhythm control in AF: insights from sub-analyses of the dual site atrial pacing for prevention of atrial fibrillation study.
Pacing Clin Electrophysiol, 26 (2003), pp. 1565
[6.]
E. Posan, R. Yee, B. Petrellis, D. Redfearn, G. Klein, A. Krahn, et al.
Long-term performance of a new catheter delivered lead (Conference Abstract).
Europace Supplements, 7 (2005), pp. 294
[7.]
B. Hansky, H. Gueldner, U. Blanz, M. Peuster, H. Meyer, R. Koerfer.
First experiences with catheter-guided atrial and ventricular lumenless pacing lead implantation in 28 pediatric patients (Conference Abstract).
Heart Rhythm, 2 (2005), pp. S88
[8.]
M.D. Gammage, R.A. Lieberman, R. Yee, A.S. Manolis, S.J. Compton, C. Khazen, et al.
Multi-center clinical experience with a lumenless, catheter- delivered, bipolar, permanent pacemaker lead: implant safety and electrical performance.
Pacing Clin Electrophysiol, 29 (2006), pp. 858-865
[9.]
P.P. Karpawich, P. Webster, E. Goodman, T. Forbes.
Repositioning a dislodged new lumenless pacing lead: a simple tool and technique.
Pacing Clin Electrophysiol, 31 (2008), pp. 354-357
[10.]
F. Zanon, E. Baracca, S. Aggio, G. Pastore, G. Boaretto, P. Cardano, et al.
A feasible approach for direct his-bundle pacing using a new steerable catheter to facilitate precise lead placement.
J Cardiovasc Electrophysiol, 17 (2006), pp. 29-33
[11.]
F. Cantu, P. DE Filippo, P. Cardano, A. DE Luca, A. Gavazzi.
Validation of criteria for selective his bundle and para-hisian permanent pacing.
Pacing Clin Electrophysiol, 29 (2006), pp. 1326-1333
[12.]
P.E. Hill.
Complications of permanent transvenous cardiac pacing: a 14-year review of all transvenous pacemakers inserted at one communityhospital.
PACE, (1987), pp. 564-570
Copyright © 2010. Socidad Colombiana de Cardiología y Cirugía Cardiovascular
Download PDF
Article options