was read the article
array:24 [ "pii" => "S1988885612000892" "issn" => "19888856" "doi" => "10.1016/j.recote.2012.09.005" "estado" => "S300" "fechaPublicacion" => "2012-09-01" "aid" => "346" "copyright" => "SECOT" "copyrightAnyo" => "2012" "documento" => "article" "crossmark" => 0 "subdocumento" => "sco" "cita" => "Rev Esp Cir Ortop Traumatol. 2012;56:385-8" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:2 [ "total" => 1246 "formatos" => array:2 [ "HTML" => 1022 "PDF" => 224 ] ] "Traduccion" => array:1 [ "es" => array:19 [ "pii" => "S1888441512000768" "issn" => "18884415" "doi" => "10.1016/j.recot.2012.05.008" "estado" => "S300" "fechaPublicacion" => "2012-09-01" "aid" => "346" "copyright" => "SECOT" "documento" => "article" "crossmark" => 0 "subdocumento" => "sco" "cita" => "Rev Esp Cir Ortop Traumatol. 2012;56:385-8" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:2 [ "total" => 2577 "formatos" => array:3 [ "EPUB" => 10 "HTML" => 2088 "PDF" => 479 ] ] "es" => array:13 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Nota clínica</span>" "titulo" => "Luxación del polietileno en prótesis patelo-femoral con patela móvil. Caso clínico" "tienePdf" => "es" "tieneTextoCompleto" => "es" "tieneResumen" => array:2 [ 0 => "es" 1 => "en" ] "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "385" "paginaFinal" => "388" ] ] "titulosAlternativos" => array:1 [ "en" => array:1 [ "titulo" => "Dislocation of the polyethylene in a patello-femoral replacement with a movable patella" ] ] "contieneResumen" => array:2 [ "es" => true "en" => true ] "contieneTextoCompleto" => array:1 [ "es" => true ] "contienePdf" => array:1 [ "es" => true ] "resumenGrafico" => array:2 [ "original" => 0 "multimedia" => array:7 [ "identificador" => "fig0010" "etiqueta" => "Figura 2" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr2.jpeg" "Alto" => 707 "Ancho" => 950 "Tamanyo" => 60304 ] ] "descripcion" => array:1 [ "es" => "<p id="spar0020" class="elsevierStyleSimplePara elsevierViewall">separación del polietileno de la base metálica patelar.</p>" ] ] ] "autores" => array:1 [ 0 => array:2 [ "autoresLista" => "M.J. Sangüesa Nebot, F. Cabanes Soriano, R. Fernández Gabarda, A. Darder Prats" "autores" => array:4 [ 0 => array:2 [ "nombre" => "M.J." "apellidos" => "Sangüesa Nebot" ] 1 => array:2 [ "nombre" => "F." "apellidos" => "Cabanes Soriano" ] 2 => array:2 [ "nombre" => "R." "apellidos" => "Fernández Gabarda" ] 3 => array:2 [ "nombre" => "A." "apellidos" => "Darder Prats" ] ] ] ] ] "idiomaDefecto" => "es" "Traduccion" => array:1 [ "en" => array:9 [ "pii" => "S1988885612000892" "doi" => "10.1016/j.recote.2012.09.005" "estado" => "S300" "subdocumento" => "" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:1 [ "total" => 0 ] "idiomaDefecto" => "en" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S1988885612000892?idApp=UINPBA00004N" ] ] "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S1888441512000768?idApp=UINPBA00004N" "url" => "/18884415/0000005600000005/v1_201305031909/S1888441512000768/v1_201305031909/es/main.assets" ] ] "itemSiguiente" => array:19 [ "pii" => "S1988885612000818" "issn" => "19888856" "doi" => "10.1016/j.recote.2012.08.003" "estado" => "S300" "fechaPublicacion" => "2012-09-01" "aid" => "347" "copyright" => "SECOT" "documento" => "article" "crossmark" => 0 "subdocumento" => "sco" "cita" => "Rev Esp Cir Ortop Traumatol. 2012;56:389-92" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:2 [ "total" => 1442 "formatos" => array:2 [ "HTML" => 1248 "PDF" => 194 ] ] "en" => array:13 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Case report</span>" "titulo" => "Acute calcific prevertebral tendinitis: Case report and literature review" "tienePdf" => "en" "tieneTextoCompleto" => "en" "tieneResumen" => array:2 [ 0 => "en" 1 => "es" ] "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "389" "paginaFinal" => "392" ] ] "titulosAlternativos" => array:1 [ "es" => array:1 [ "titulo" => "Tendinitis calcificante prevertebral aguda: a propósito de un caso y revisión de la literatura" ] ] "contieneResumen" => array:2 [ "en" => true "es" => true ] "contieneTextoCompleto" => array:1 [ "en" => true ] "contienePdf" => array:1 [ "en" => true ] "resumenGrafico" => array:2 [ "original" => 0 "multimedia" => array:7 [ "identificador" => "fig0005" "etiqueta" => "Figure 1" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr1.jpeg" "Alto" => 1742 "Ancho" => 2333 "Tamanyo" => 165124 ] ] "descripcion" => array:1 [ "en" => "<p id="spar0015" class="elsevierStyleSimplePara elsevierViewall">(A) Lateral radiographic projection showing a normal prevertebral space (about 7<span class="elsevierStyleHsp" style=""></span>mm at the C3 level and 3<span class="elsevierStyleHsp" style=""></span>cm at the C7 level). (B) Anterior displacement of the airway due to a marked increase of the prevertebral space, mainly from C1 to C4. A radiodense image can be seen at the C1–C2 level. The time interval between both radiographs was 2 days.</p>" ] ] ] "autores" => array:1 [ 0 => array:2 [ "autoresLista" => "V. Pellicer García, C. Pérez Moya, A. Magán Martín" "autores" => array:3 [ 0 => array:2 [ "nombre" => "V." "apellidos" => "Pellicer García" ] 1 => array:2 [ "nombre" => "C." "apellidos" => "Pérez Moya" ] 2 => array:2 [ "nombre" => "A." "apellidos" => "Magán Martín" ] ] ] ] ] "idiomaDefecto" => "en" "Traduccion" => array:1 [ "es" => array:9 [ "pii" => "S188844151200077X" "doi" => "10.1016/j.recot.2012.05.009" "estado" => "S300" "subdocumento" => "" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:1 [ "total" => 0 ] "idiomaDefecto" => "es" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S188844151200077X?idApp=UINPBA00004N" ] ] "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S1988885612000818?idApp=UINPBA00004N" "url" => "/19888856/0000005600000005/v1_201305031814/S1988885612000818/v1_201305031814/en/main.assets" ] "itemAnterior" => array:19 [ "pii" => "S1988885612000806" "issn" => "19888856" "doi" => "10.1016/j.recote.2012.08.002" "estado" => "S300" "fechaPublicacion" => "2012-09-01" "aid" => "343" "copyright" => "SECOT" "documento" => "article" "crossmark" => 0 "subdocumento" => "sco" "cita" => "Rev Esp Cir Ortop Traumatol. 2012;56:381-4" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:2 [ "total" => 650 "formatos" => array:2 [ "HTML" => 541 "PDF" => 109 ] ] "en" => array:13 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Case report</span>" "titulo" => "Aplasia of the posterior arches of the atlas: A presentation of 2 cases" "tienePdf" => "en" "tieneTextoCompleto" => "en" "tieneResumen" => array:2 [ 0 => "en" 1 => "es" ] "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "381" "paginaFinal" => "384" ] ] "titulosAlternativos" => array:1 [ "es" => array:1 [ "titulo" => "Aplasia de los arcos posteriores del atlas: a propósito de 2 casos" ] ] "contieneResumen" => array:2 [ "en" => true "es" => true ] "contieneTextoCompleto" => array:1 [ "en" => true ] "contienePdf" => array:1 [ "en" => true ] "resumenGrafico" => array:2 [ "original" => 0 "multimedia" => array:7 [ "identificador" => "fig0005" "etiqueta" => "Figure 1" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr1.jpeg" "Alto" => 1820 "Ancho" => 1300 "Tamanyo" => 242666 ] ] "descripcion" => array:1 [ "en" => "<p id="spar0035" class="elsevierStyleSimplePara elsevierViewall">(A) Lateral radiograph of case 1. (B) Lateral radiograph of case 2, showing a remnant of the right arch. (C) 3D CT scan image of case 1.</p>" ] ] ] "autores" => array:1 [ 0 => array:2 [ "autoresLista" => "T. Quinteiro Antolín, I. Castellano Romero, J. Yáñez Calvo" "autores" => array:3 [ 0 => array:2 [ "nombre" => "T." "apellidos" => "Quinteiro Antolín" ] 1 => array:2 [ "nombre" => "I." "apellidos" => "Castellano Romero" ] 2 => array:2 [ "nombre" => "J." "apellidos" => "Yáñez Calvo" ] ] ] ] ] "idiomaDefecto" => "en" "Traduccion" => array:1 [ "es" => array:9 [ "pii" => "S1888441512000732" "doi" => "10.1016/j.recot.2012.05.005" "estado" => "S300" "subdocumento" => "" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:1 [ "total" => 0 ] "idiomaDefecto" => "es" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S1888441512000732?idApp=UINPBA00004N" ] ] "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S1988885612000806?idApp=UINPBA00004N" "url" => "/19888856/0000005600000005/v1_201305031814/S1988885612000806/v1_201305031814/en/main.assets" ] "en" => array:20 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Case report</span>" "titulo" => "Dislocation of the polyethylene in a patellofemoral replacement with a movable patella" "tieneTextoCompleto" => true "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "385" "paginaFinal" => "388" ] ] "autores" => array:1 [ 0 => array:4 [ "autoresLista" => "M.J. Sangüesa Nebot, F. Cabanes Soriano, R. Fernández Gabarda, A. Darder Prats" "autores" => array:4 [ 0 => array:4 [ "nombre" => "M.J." "apellidos" => "Sangüesa Nebot" "email" => array:1 [ 0 => "mjsanneb@hotmail.com" ] "referencia" => array:1 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">¿</span>" "identificador" => "cor0005" ] ] ] 1 => array:2 [ "nombre" => "F." "apellidos" => "Cabanes Soriano" ] 2 => array:2 [ "nombre" => "R." "apellidos" => "Fernández Gabarda" ] 3 => array:2 [ "nombre" => "A." "apellidos" => "Darder Prats" ] ] "afiliaciones" => array:1 [ 0 => array:1 [ "entidad" => "Servicio de Traumatología y Cirugía Ortopédica, Hospital Arnau de Vilanova de Valencia, Valencia, Spain" ] ] "correspondencia" => array:1 [ 0 => array:3 [ "identificador" => "cor0005" "etiqueta" => "⁎" "correspondencia" => "Corresponding author." ] ] ] ] "titulosAlternativos" => array:1 [ "es" => array:1 [ "titulo" => "Luxación del polietileno en prótesis patelo-femoral con patela móvil" ] ] "resumenGrafico" => array:2 [ "original" => 0 "multimedia" => array:7 [ "identificador" => "fig0005" "etiqueta" => "Figure 1" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr1.jpeg" "Alto" => 950 "Ancho" => 1274 "Tamanyo" => 131693 ] ] "descripcion" => array:1 [ "en" => "<p id="spar0015" class="elsevierStyleSimplePara elsevierViewall">Left patellofemoral arthroplasty with LCS patellofemoral prosthesis (DePuy, Warsaw, IN, USA).</p>" ] ] ] "textoCompleto" => "<span class="elsevierStyleSections"><span id="sec0005" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle">Introduction</span><p id="par0005" class="elsevierStylePara elsevierViewall">Isolated patellofemoral osteoarthritis remains an unsolved problem in degenerative knee pathology. It is radiographically observed in 11% of men and 24% of women over 55 years in whom a radiographic study is conducted due to a symptomatic knee.<a class="elsevierStyleCrossRefs" href="#bib0005"><span class="elsevierStyleSup">1–3</span></a> Surgical treatment is reserved for patients with functional failure and severe pain symptoms in whom conservative measures have not been successful. The choice of surgical technique is based on the symptoms, along with objective findings and other factors such as age, level of activity and occupation.<a class="elsevierStyleCrossRef" href="#bib0020"><span class="elsevierStyleSup">4</span></a> Such procedures include cleaning arthroscopy, osteotomy, osteochondral transplants and patellectomies, all with poor results.<a class="elsevierStyleCrossRef" href="#bib0025"><span class="elsevierStyleSup">5</span></a> Although in older patients total knee arthroplasty seems the best option, in patients under 55–60 years with normal tibiofemoral alignment, without signs of patellar subluxation and with reasonable functional expectations, patellofemoral arthroplasty may be considered as a preferable option as it is less invasive and preserves the tibiofemoral joint.</p><p id="par0010" class="elsevierStylePara elsevierViewall">McKeever created the first design for a patellofemoral prosthesis in 1955, although it was not until the 1970s, with the introduction of the designs by Lubinus and Richard, that their regular use became widespread. In an attempt to improve results, in recent years there has been a renewed interest in patellofemoral arthroplasties which incorporated design changes and enhancements, improved instrumentation for a more accurate surgical technique and an adjustment in the indications. The latest prosthetic design to be introduced has been a patellofemoral prosthesis with mobile polyethylene.</p><p id="par0015" class="elsevierStylePara elsevierViewall">We report a rare complication: dislocation of polyethylene in the patellar metal base. This is the first case reported in the Spanish literature and the tenth worldwide.</p></span><span id="sec0010" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle">Case report</span><p id="par0020" class="elsevierStylePara elsevierViewall">We describe the case of a 55-year-old woman who attended our service due to persistent bilateral knee pain after undergoing partial medial patellectomy and arthroscopy on her left knee 1 year earlier. Exploration of the left knee, more symptomatic than the right, revealed patellofemoral findings and a range of movement with 10° extension. Radiographic images showed gonarthrosis, mainly of the patellofemoral compartment (<a class="elsevierStyleCrossRef" href="#fig0005">Fig. 1</a>), and a magnetic resonance study revealed a bilateral patellofemoral arthrosic chondropathy.</p><elsevierMultimedia ident="fig0005"></elsevierMultimedia><p id="par0025" class="elsevierStylePara elsevierViewall">In February 2005, the patient underwent a patellofemoral arthroplasty with a left Low Contact Stress (LCS) patellofemoral prosthesis (DePuy, Warsaw, IN, USA) (<a class="elsevierStyleCrossRef" href="#fig0005">Fig. 1</a>). She progressed satisfactorily, reporting clinical improvement and personal satisfaction. Two years later, plain radiographs showed no change compared to the initial images and the range of motion was −5°/130°. Three years after the surgery, radiographic images remained unchanged and the range of motion was 10°/130°.</p><p id="par0030" class="elsevierStylePara elsevierViewall">At 4 years after surgery, the patient consulted due to persistent knee pain without history of trauma and with an evolution of various months. Plain radiographs showed a separation of the polyethylene component from the patellar metal base. According to its markers, the polyethylene was located at the bottom of the external quadricipital recess (<a class="elsevierStyleCrossRef" href="#fig0010">Fig. 2</a>). We considered replacing the partial patellofemoral arthroplasty with a total knee arthroplasty. During surgery, we confirmed that the patellar polyethylene component was dislocated and free within the knee. In addition, discrete metallosis was also observed in the periprosthetic soft tissues, supposedly due to the dislocation and the duration of knee pain. Once removed, the implant showed metal–metal friction marks. Review surgery was performed using a complete LCS primary prosthesis with rotating platform (DePuy, Warsaw, IN, USA), without incident and with a good subsequent evolution. Three years after surgery, the patient remained asymptomatic, presented a good range of motion (−5°/100°) and manifested her satisfaction.</p><elsevierMultimedia ident="fig0010"></elsevierMultimedia></span><span id="sec0015" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle">Discussion</span><p id="par0035" class="elsevierStylePara elsevierViewall">Different causes of patellofemoral arthropathy require different treatments, with the most common causes being malalignment, dysplasia, instability, trauma, inflammatory arthritis, obesity and osteoarthritis. The choice of treatment is based on the symptoms, on objective findings and on other data such as age, activity and occupation.<a class="elsevierStyleCrossRef" href="#bib0020"><span class="elsevierStyleSup">4</span></a> According to Witjes, the best candidates for patellofemoral arthroplasty are patients younger than 55–60 years with normal tibiofemoral alignment and without signs of patellar subluxation.<a class="elsevierStyleCrossRef" href="#bib0020"><span class="elsevierStyleSup">4</span></a></p><p id="par0040" class="elsevierStylePara elsevierViewall">A literature review resulted in the identification of the following contraindications for patellofemoral arthroplasty: first treatment choice being without having tried other conservative options, tibiofemoral joint osteoarthritis, systemic inflammatory joint disease, unevolved patellofemoral osteoarthritis, low patella, instability with patellofemoral misalignment, tibiofemoral mechanical malalignment (more than 5° varus or more than 8° valgus), active infection, clinical symptoms of complex regional pain and limitation of knee motion (−10° extension and 110° flexion).<a class="elsevierStyleCrossRef" href="#bib0025"><span class="elsevierStyleSup">5</span></a> In any case, it should be noted that this literature review was conducted on very few studies, all with a low number of patients and limited available data. The problems leading to failure of a patellofemoral arthroplasty include progression to tibiofemoral osteoarthritis, patellar pain, subluxation due to poor balance of soft parts, poor surgical technique with malposition of the components and design problems.<a class="elsevierStyleCrossRef" href="#bib0030"><span class="elsevierStyleSup">6</span></a></p><p id="par0045" class="elsevierStylePara elsevierViewall">Most current patellofemoral arthroplasty designs are based on total knee arthroplasty patellofemoral designs with certain modifications such as intramedullary instrumentation, a greater range of sizes, providing compatibility of the patellar prosthesis with total review arthroplasty, a minimal incision, improved cementing techniques and better polyethylene materials, a superolateral extension of the trochlear ridge to improve patellar capture and a less constrained trochlear angle to reduce path errors of the patellar prosthesis.<a class="elsevierStyleCrossRef" href="#bib0035"><span class="elsevierStyleSup">7</span></a></p><p id="par0050" class="elsevierStylePara elsevierViewall">It was Merchant who, in 2001, designed a modular patellofemoral prosthesis based on the design of the LCS total knee prosthesis, with some design inspiration from Richards.<a class="elsevierStyleCrossRef" href="#bib0040"><span class="elsevierStyleSup">8</span></a> This was a patellar implant prosthesis with mobile and congruent anatomical polyethylene seated on a thin metal base. Congruence improved any potential polyethylene wear problems, whereas mobility decreased shear forces and thus reduced loosening. This patellar component was articulated with a metallic trochlear component.<a class="elsevierStyleCrossRef" href="#bib0045"><span class="elsevierStyleSup">9</span></a></p><p id="par0055" class="elsevierStylePara elsevierViewall">The percentages of reviews in LCS patellofemoral arthroplasties with mobile polyethylene have been high, even leading some authors to abandon their use.<a class="elsevierStyleCrossRef" href="#bib0045"><span class="elsevierStyleSup">9</span></a> The weakest point of the LCS patellofemoral prosthesis lies in the interface of the articulated polyethylene insert with the metallic base.<a class="elsevierStyleCrossRef" href="#bib0050"><span class="elsevierStyleSup">10</span></a></p><p id="par0060" class="elsevierStylePara elsevierViewall">Dislocation of the polyethylene component is a rare complication. So far, we found 9 reported cases in the literature of polyethylene dislocations in LCS patellofemoral prostheses: Witjes et al. reported 2 cases in 2009,<a class="elsevierStyleCrossRef" href="#bib0020"><span class="elsevierStyleSup">4</span></a> Van Jonbergen et al. reported 2 cases in 2009,<a class="elsevierStyleCrossRef" href="#bib0015"><span class="elsevierStyleSup">3</span></a> Sreekumar et al. reported 1 case in 2009,<a class="elsevierStyleCrossRef" href="#bib0030"><span class="elsevierStyleSup">6</span></a> Arumilli et al. reported 2 cases in 1 patient (repetition) in 2010<a class="elsevierStyleCrossRef" href="#bib0050"><span class="elsevierStyleSup">10</span></a> and Charalambous et al. reported 2 cases in 2011.<a class="elsevierStyleCrossRef" href="#bib0010"><span class="elsevierStyleSup">2</span></a></p><p id="par0065" class="elsevierStylePara elsevierViewall">The causes of component dissociation would be multifactorial: poor surgical technique regarding the placement of implants, prosthetic design and selection of patients.</p><p id="par0070" class="elsevierStylePara elsevierViewall">Leadbetter collects a personal communication by Fulkerson, stating that high patella leads to a risk of collision in the first degrees of flexion of the patellar component at the top ridge of the femoral prosthesis, with this posing a risk of dislocation.<a class="elsevierStyleCrossRef" href="#bib0025"><span class="elsevierStyleSup">5</span></a> This would be a cause of residual clicking and locking sensation in the initial designs of Lubinus, which Argenson et al. attempted to compensate by inserting the femoral component slightly deeper, with the drawback of creating a femoral notch.<a class="elsevierStyleCrossRef" href="#bib0055"><span class="elsevierStyleSup">11</span></a></p><p id="par0075" class="elsevierStylePara elsevierViewall">Other authors have noted that dislocation occurs when the polyethylene rotates over 30°, at which point it jumps over the pin anchoring it to the metal base, which stays in place. In other words, the problem would be a wrong position of the patellar insert, leading to a rotation of the polyethylene over 30° on the base. In order to avoid this, we must be careful when orienting the patella, as this orientation takes place with the patella in an everted position, and its transverse axis is not the same when everted as after being reduced. With an everted patella, the patellar guide should be placed with about 20° inferior deflection. Thus, when its transverse axis is reduced, it will be parallel to the transverse axis of the knee.<a class="elsevierStyleCrossRef" href="#bib0045"><span class="elsevierStyleSup">9</span></a> But even after adequately orienting the patellar metal base, patellofemoral malalignment or instability represent contraindications, as they may require a rotation of the polyethylene over 35°.<a class="elsevierStyleCrossRef" href="#bib0020"><span class="elsevierStyleSup">4</span></a> A wrong patellar path could cause the corner of the polyethylene component to become caught in the margin or corner of the femoral trochlear component, leading to polyethylene dislocation.<a class="elsevierStyleCrossRef" href="#bib0010"><span class="elsevierStyleSup">2</span></a></p><p id="par0080" class="elsevierStylePara elsevierViewall">One advantage introduced by the LCS design in patellofemoral arthroplasties is that, in case conversion into total knee arthroplasty becomes necessary, it is not necessary to replace the patella. Obviously, if a dislocation of the polyethylene from the patellar base takes place, total replacement will be required in order to correct the deficiencies leading to this complication.</p><p id="par0085" class="elsevierStylePara elsevierViewall">In the case described it seemed that a previous high patella (with an Insall–Salvati index of 1.29) was the reason that led to a high prosthetised patella with respect to the trochlear insert, eventually leading to the polyethylene becoming caught on the trochlear edge and dislocating upon flexion.</p><p id="par0090" class="elsevierStylePara elsevierViewall">The use of patellofemoral arthroplasties remains controversial. Arumilli et al. observed high rates of review after a short series of mobile patellofemoral arthroplasties, leading them to abandon the technique.<a class="elsevierStyleCrossRef" href="#bib0050"><span class="elsevierStyleSup">10</span></a> Charalambous et al. conducted an independent, short-term review of mobile LCS patellofemoral prostheses with disappointing results. They reported a high percentage of reviews and concluded that their use could not be recommended.<a class="elsevierStyleCrossRef" href="#bib0010"><span class="elsevierStyleSup">2</span></a> In any case, patellofemoral prostheses do not replace patellofemoral realignment, and in the event of there existing a patellofemoral misalignment and obviously also a high patella, these should be corrected during the same surgical procedure of patellofemoral prosthesis, adapting the technique to the previous pathology.</p></span><span id="sec0020" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle">Level of evidence</span><p id="par0095" class="elsevierStylePara elsevierViewall">Level of evidence IV.</p></span><span id="sec0025" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle">Ethical responsibilities</span><p id="par0100" class="elsevierStylePara elsevierViewall"><span class="elsevierStyleBold">Protection of people and animals</span>. The authors declare that this investigation did not require experiments on humans or animals.<span class="elsevierStyleVsp" style="height:0.5px"></span><span class="elsevierStyleBold">Confidentiality of data</span>. The authors declare that this study does not reflect any patient data.<span class="elsevierStyleVsp" style="height:0.5px"></span><span class="elsevierStyleBold">Right to privacy and informed consent</span>. The authors declare that this study does not reflect any patient data.</p></span></span>" "textoCompletoSecciones" => array:1 [ "secciones" => array:10 [ 0 => array:2 [ "identificador" => "xres116675" "titulo" => "Abstract" ] 1 => array:2 [ "identificador" => "xpalclavsec103961" "titulo" => "Keywords" ] 2 => array:2 [ "identificador" => "xres116676" "titulo" => "Resumen" ] 3 => array:2 [ "identificador" => "xpalclavsec103960" "titulo" => "Palabras clave" ] 4 => array:2 [ "identificador" => "sec0005" "titulo" => "Introduction" ] 5 => array:2 [ "identificador" => "sec0010" "titulo" => "Case report" ] 6 => array:2 [ "identificador" => "sec0015" "titulo" => "Discussion" ] 7 => array:2 [ "identificador" => "sec0020" "titulo" => "Level of evidence" ] 8 => array:2 [ "identificador" => "sec0025" "titulo" => "Ethical responsibilities" ] 9 => array:1 [ "titulo" => "References" ] ] ] "pdfFichero" => "main.pdf" "tienePdf" => true "fechaRecibido" => "2012-03-05" "fechaAceptado" => "2012-05-23" "PalabrasClave" => array:2 [ "en" => array:1 [ 0 => array:4 [ "clase" => "keyword" "titulo" => "Keywords" "identificador" => "xpalclavsec103961" "palabras" => array:4 [ 0 => "Patellofemoral arthritis" 1 => "Patellofemoral arthroplasty" 2 => "Dislocation of mobile component" 3 => "Complication of patellofemoral arthroplasty" ] ] ] "es" => array:1 [ 0 => array:4 [ "clase" => "keyword" "titulo" => "Palabras clave" "identificador" => "xpalclavsec103960" "palabras" => array:4 [ 0 => "Artrosis femoro-patelar" 1 => "Artroplastia femoro-patelar" 2 => "Luxación polietileno patela" 3 => "Complicaciones artroplastia patelo-femoral" ] ] ] ] "tieneResumen" => true "resumen" => array:2 [ "en" => array:2 [ "titulo" => "Abstract" "resumen" => "<p id="spar0005" class="elsevierStyleSimplePara elsevierViewall">Patellofemoral arthroplasty is an infrequently used surgical technique because of its controversial results. In an attempt to improve the results, a design with a mobile-bearing polyethylene patellar component has been developed. We describe a clinical case with an unusual complication: the dislocation of polyethylene from the metal backing; and accordingly, we carried out a literature review of this complication.</p>" ] "es" => array:2 [ "titulo" => "Resumen" "resumen" => "<p id="spar0010" class="elsevierStyleSimplePara elsevierViewall">La artroplastia femoro-patelar continúa siendo una técnica quirúrgica poco utilizada por los discutidos resultados obtenidos. En un intento de mejorar sus resultados se introdujo el diseño con polietileno móvil. Presentamos un caso clínico con una complicación poco frecuente: la luxación del polietileno de la base metálica de la patela; y a propósito realizamos una revisión bibliográfica de esta complicación.</p>" ] ] "NotaPie" => array:1 [ 0 => array:2 [ "etiqueta" => "☆" "nota" => "<p class="elsevierStyleNotepara">Please cite this article as: Sangüesa Nebot MJ, et al. Luxación del polietileno en prótesis patelo-femoral con patela móvil. Caso clínico. Rev Esp Cir Ortop Traumatol. 2012;<span class="elsevierStyleBold">56</span>:385–8.</p>" ] ] "multimedia" => array:2 [ 0 => array:7 [ "identificador" => "fig0005" "etiqueta" => "Figure 1" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr1.jpeg" "Alto" => 950 "Ancho" => 1274 "Tamanyo" => 131693 ] ] "descripcion" => array:1 [ "en" => "<p id="spar0015" class="elsevierStyleSimplePara elsevierViewall">Left patellofemoral arthroplasty with LCS patellofemoral prosthesis (DePuy, Warsaw, IN, USA).</p>" ] ] 1 => array:7 [ "identificador" => "fig0010" "etiqueta" => "Figure 2" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr2.jpeg" "Alto" => 707 "Ancho" => 950 "Tamanyo" => 60304 ] ] "descripcion" => array:1 [ "en" => "<p id="spar0020" class="elsevierStyleSimplePara elsevierViewall">Separation of the polyethylene from the patellar metallic base.</p>" ] ] ] "bibliografia" => array:2 [ "titulo" => "References" "seccion" => array:1 [ 0 => array:2 [ "identificador" => "bibs0005" "bibliografiaReferencia" => array:11 [ 0 => array:3 [ "identificador" => "bib0005" "etiqueta" => "1" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Radiographic patterns of osteoarthritis of the knee joint in the community: the importance of the patellofemoral joint" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:4 [ 0 => "T.O. McAlindon" 1 => "S. Snow" 2 => "C. Cooper" 3 => "P.A. Dieppe" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Ann Rheum Dis" "fecha" => "1992" "volumen" => "51" "paginaInicial" => "844" "paginaFinal" => "849" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/1632657" "web" => "Medline" ] ] ] ] ] ] ] ] 1 => array:3 [ "identificador" => "bib0010" "etiqueta" => "2" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "The low contact stress patellofemoral replacement. High early failure rate" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:6 [ 0 => "C.P. Charalambous" 1 => "Z. Abiddin" 2 => "S.P. Mills" 3 => "S. Rogers" 4 => "P. Sutton" 5 => "R. Parkinson" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:5 [ "tituloSerie" => "J Bone Joint Surg Br" "fecha" => "2011" "volumen" => "93 B" "paginaInicial" => "484" "paginaFinal" => "489" ] ] ] ] ] ] 2 => array:3 [ "identificador" => "bib0015" "etiqueta" => "3" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Dissociation of mobile-bearing patellar component in low contact stress patellofemoral arthroplasty. Its mechanism and management: two case reports" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "H.P.W. Van Jonbergen" 1 => "D.M. Werkman" 2 => "A.F.W. Barnaart" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:5 [ "tituloSerie" => "Cases J" "fecha" => "2009" "volumen" => "2" "paginaInicial" => "750" "paginaFinal" => "752" ] ] ] ] ] ] 3 => array:3 [ "identificador" => "bib0020" "etiqueta" => "4" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Dislocation of the mobile bearing component of a patellofemoral arthroplasty: a report of two cases" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:4 [ 0 => "S. Witjes" 1 => "C. Van Den Broek" 2 => "S. Koeter" 3 => "C. Van Loon" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Acta Orthop Belg" "fecha" => "2009" "volumen" => "75" "paginaInicial" => "411" "paginaFinal" => "416" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/19681331" "web" => "Medline" ] ] ] ] ] ] ] ] 4 => array:3 [ "identificador" => "bib0025" "etiqueta" => "5" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "The appropriate use of patellofemoral arthroplasty. An analysis of reported indications, contraindications and failures" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "W.B. Leadbetter" 1 => "P.S. Ragland" 2 => "M.A. Mont" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Clin Orthop" "fecha" => "2005" "volumen" => "436" "paginaInicial" => "91" "paginaFinal" => "99" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/15995426" "web" => "Medline" ] ] ] ] ] ] ] ] 5 => array:3 [ "identificador" => "bib0030" "etiqueta" => "6" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Patellar button dissociation in a mobile-bearing LCS patellofemoral joint arthroplasty" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "R. Sreekumar" 1 => "S. Subramanian" 2 => "A. Mohammed" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "J Knee Surg" "fecha" => "2009" "volumen" => "22" "paginaInicial" => "275" "paginaFinal" => "278" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/19634736" "web" => "Medline" ] ] ] ] ] ] ] ] 6 => array:3 [ "identificador" => "bib0035" "etiqueta" => "7" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Indications, contraindications, and pitfalls of patellofemoral arthroplasty" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:4 [ 0 => "W.B. Leadbetter" 1 => "T.M. Seyler" 2 => "P.S. Ragland" 3 => "M.A. Mont" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "J Bone Joint Surg" "fecha" => "2006" "volumen" => "88A" "numero" => "Suppl. 4" "paginaInicial" => "122" "paginaFinal" => "137" ] ] ] ] ] ] 7 => array:3 [ "identificador" => "bib0040" "etiqueta" => "8" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Early results with a total patellofemoral joint replacement arthroplasty prosthesis" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:1 [ 0 => "A.C. Merchant" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "J Arthroplasty" "fecha" => "2004" "volumen" => "19" "paginaInicial" => "829" "paginaFinal" => "836" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/15483797" "web" => "Medline" ] ] ] ] ] ] ] ] 8 => array:3 [ "identificador" => "bib0045" "etiqueta" => "9" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "The long-term results of a metal-backed mobile bearing patella" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:4 [ 0 => "L.R. Jordan" 1 => "R.B. Sorrells" 2 => "L.C. Jordan" 3 => "J.L. Olivo" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Clin Orthop" "fecha" => "2005" "volumen" => "436" "paginaInicial" => "111" "paginaFinal" => "118" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/15995428" "web" => "Medline" ] ] ] ] ] ] ] ] 9 => array:3 [ "identificador" => "bib0050" "etiqueta" => "10" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Unusual mechanical complications of unicompartimental low contact stress mobile bearing patellofemoral arthroplasty: a cause of concern" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:4 [ 0 => "B.R.B. Arumilli" 1 => "A.B.Y. Ng" 2 => "D.J. Ellis" 3 => "P. Hirst" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.knee.2009.10.006" "Revista" => array:6 [ "tituloSerie" => "The Knee" "fecha" => "2010" "volumen" => "17" "paginaInicial" => "362" "paginaFinal" => "364" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/19897372" "web" => "Medline" ] ] ] ] ] ] ] ] 10 => array:3 [ "identificador" => "bib0055" "etiqueta" => "11" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Is there a place for patellofemoral arthroplasty?" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "J.N. Argenson" 1 => "J.M. Guillaume" 2 => "J.M. Aubinac" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Clin Orthop" "fecha" => "1995" "volumen" => "321" "paginaInicial" => "162" "paginaFinal" => "167" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/7497663" "web" => "Medline" ] ] ] ] ] ] ] ] ] ] ] ] ] "idiomaDefecto" => "en" "url" => "/19888856/0000005600000005/v1_201305031814/S1988885612000892/v1_201305031814/en/main.assets" "Apartado" => array:4 [ "identificador" => "7586" "tipo" => "SECCION" "en" => array:2 [ "titulo" => "Case reports" "idiomaDefecto" => true ] "idiomaDefecto" => "en" ] "PDF" => "https://static.elsevier.es/multimedia/19888856/0000005600000005/v1_201305031814/S1988885612000892/v1_201305031814/en/main.pdf?idApp=UINPBA00004N&text.app=https://www.elsevier.es/" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S1988885612000892?idApp=UINPBA00004N" ]
Year/Month | Html | Total | |
---|---|---|---|
2024 November | 5 | 0 | 5 |
2024 October | 26 | 5 | 31 |
2024 September | 28 | 5 | 33 |
2024 August | 32 | 2 | 34 |
2024 July | 32 | 2 | 34 |
2024 June | 24 | 3 | 27 |
2024 May | 28 | 2 | 30 |
2024 April | 32 | 5 | 37 |
2024 March | 45 | 2 | 47 |
2024 February | 54 | 4 | 58 |
2024 January | 61 | 8 | 69 |
2023 December | 37 | 4 | 41 |
2023 November | 31 | 3 | 34 |
2023 October | 45 | 13 | 58 |
2023 September | 21 | 4 | 25 |
2023 August | 23 | 4 | 27 |
2023 July | 70 | 6 | 76 |
2023 June | 40 | 5 | 45 |
2023 May | 52 | 5 | 57 |
2023 April | 32 | 3 | 35 |
2023 March | 53 | 1 | 54 |
2023 February | 33 | 10 | 43 |
2023 January | 38 | 7 | 45 |
2022 December | 38 | 14 | 52 |
2022 November | 28 | 9 | 37 |
2022 October | 29 | 22 | 51 |
2022 September | 28 | 8 | 36 |
2022 August | 32 | 25 | 57 |
2022 July | 28 | 14 | 42 |
2022 June | 13 | 6 | 19 |
2022 May | 11 | 6 | 17 |
2022 April | 13 | 11 | 24 |
2022 March | 20 | 19 | 39 |
2022 February | 15 | 13 | 28 |
2022 January | 15 | 14 | 29 |
2021 December | 14 | 17 | 31 |
2021 November | 14 | 17 | 31 |
2021 October | 24 | 14 | 38 |
2021 September | 8 | 9 | 17 |
2021 August | 12 | 13 | 25 |
2021 July | 7 | 8 | 15 |
2021 June | 15 | 5 | 20 |
2021 May | 17 | 9 | 26 |
2021 April | 25 | 34 | 59 |
2021 March | 23 | 11 | 34 |
2021 February | 26 | 9 | 35 |
2021 January | 16 | 6 | 22 |
2020 December | 1 | 0 | 1 |
2018 February | 16 | 2 | 18 |
2018 January | 12 | 1 | 13 |
2017 December | 7 | 0 | 7 |
2017 November | 12 | 1 | 13 |
2017 October | 24 | 1 | 25 |
2017 September | 15 | 4 | 19 |
2017 August | 20 | 14 | 34 |
2017 July | 18 | 3 | 21 |
2017 June | 31 | 3 | 34 |
2017 May | 38 | 3 | 41 |
2017 April | 21 | 2 | 23 |
2017 March | 23 | 34 | 57 |
2017 February | 25 | 8 | 33 |
2017 January | 47 | 0 | 47 |
2016 December | 22 | 4 | 26 |
2016 November | 33 | 6 | 39 |
2016 October | 56 | 7 | 63 |
2016 September | 63 | 6 | 69 |
2016 August | 22 | 2 | 24 |
2016 July | 15 | 1 | 16 |
2016 June | 12 | 4 | 16 |
2016 May | 19 | 5 | 24 |
2016 April | 13 | 7 | 20 |
2016 March | 20 | 6 | 26 |
2016 February | 26 | 7 | 33 |
2016 January | 15 | 4 | 19 |
2015 December | 25 | 5 | 30 |
2015 November | 10 | 2 | 12 |
2015 October | 23 | 6 | 29 |
2015 September | 18 | 7 | 25 |
2015 August | 41 | 7 | 48 |
2015 July | 38 | 9 | 47 |
2015 June | 20 | 2 | 22 |
2015 May | 32 | 6 | 38 |
2015 April | 32 | 10 | 42 |
2015 March | 23 | 3 | 26 |
2015 February | 15 | 1 | 16 |
2015 January | 24 | 4 | 28 |
2014 December | 19 | 5 | 24 |
2014 November | 14 | 2 | 16 |
2014 October | 29 | 7 | 36 |
2014 September | 21 | 10 | 31 |
2014 August | 1 | 0 | 1 |
2014 July | 1 | 1 | 2 |
2014 June | 1 | 1 | 2 |
2014 May | 5 | 1 | 6 |
2013 July | 1 | 0 | 1 |
2013 June | 1 | 0 | 1 |
2013 May | 3 | 0 | 3 |