was read the article
array:24 [ "pii" => "S1988885620300286" "issn" => "19888856" "doi" => "10.1016/j.recote.2020.03.006" "estado" => "S300" "fechaPublicacion" => "2020-05-01" "aid" => "851" "copyright" => "SECOT" "copyrightAnyo" => "2020" "documento" => "article" "crossmark" => 1 "subdocumento" => "fla" "cita" => "Rev Esp Cir Ortop Traumatol. 2020;64:167-76" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:1 [ "total" => 0 ] "Traduccion" => array:1 [ "es" => array:19 [ "pii" => "S1888441520300023" "issn" => "18884415" "doi" => "10.1016/j.recot.2019.12.004" "estado" => "S300" "fechaPublicacion" => "2020-05-01" "aid" => "851" "copyright" => "SECOT" "documento" => "article" "crossmark" => 1 "subdocumento" => "fla" "cita" => "Rev Esp Cir Ortop Traumatol. 2020;64:167-76" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:1 [ "total" => 0 ] "es" => array:13 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Original</span>" "titulo" => "Descripción y análisis del patrón de normalidad de flujo dinámico y morfológico de las arterias principales de la muñeca y mano en población sana española" "tienePdf" => "es" "tieneTextoCompleto" => "es" "tieneResumen" => array:2 [ 0 => "es" 1 => "en" ] "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "167" "paginaFinal" => "176" ] ] "titulosAlternativos" => array:1 [ "en" => array:1 [ "titulo" => "Description and analysis of the dynamic and morphological flow pattern of the main arteries of the wrist and hand in a healthy spanish population" ] ] "contieneResumen" => array:2 [ "es" => true "en" => true ] "contieneTextoCompleto" => array:1 [ "es" => true ] "contienePdf" => array:1 [ "es" => true ] "resumenGrafico" => array:2 [ "original" => 0 "multimedia" => array:7 [ "identificador" => "fig0015" "etiqueta" => "Figura 3" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr3.jpeg" "Alto" => 2613 "Ancho" => 2500 "Tamanyo" => 353022 ] ] "descripcion" => array:1 [ "es" => "<p id="spar0050" class="elsevierStyleSimplePara elsevierViewall">Estudio comparativo del tamaño (diámetro trasversal) de las arterias radial y ulnar a nivel de la muñeca mostrado en cm. A)<span class="elsevierStyleHsp" style=""></span>Comparación a nivel general (sin ninguna discriminación). B)<span class="elsevierStyleHsp" style=""></span>Comparación en función del lado (muñeca derecha/muñeca izquierda). C)<span class="elsevierStyleHsp" style=""></span>Comparación en función de la dominancia (mano dominante/mano no dominante). D)<span class="elsevierStyleHsp" style=""></span>Comparación en función del género (masculino/femenino). El asterisco indica diferencias estadísticamente significativas en un valor de p <<span class="elsevierStyleHsp" style=""></span>0,05.</p>" ] ] ] "autores" => array:1 [ 0 => array:2 [ "autoresLista" => "Jaime Coderech Carretero, Fernando Corella Montoya, Miguel Grande Barez, Miguel Ángel Corella Montoya, Montserrat Ocampos Hernández, Ricardo Larrainzar-Garijo" "autores" => array:6 [ 0 => array:2 [ "nombre" => "Jaime" "apellidos" => "Coderech Carretero" ] 1 => array:2 [ "nombre" => "Fernando" "apellidos" => "Corella Montoya" ] 2 => array:2 [ "nombre" => "Miguel" "apellidos" => "Grande Barez" ] 3 => array:2 [ "nombre" => "Miguel Ángel" "apellidos" => "Corella Montoya" ] 4 => array:2 [ "nombre" => "Montserrat" "apellidos" => "Ocampos Hernández" ] 5 => array:2 [ "nombre" => "Ricardo" "apellidos" => "Larrainzar-Garijo" ] ] ] ] ] "idiomaDefecto" => "es" "Traduccion" => array:1 [ "en" => array:9 [ "pii" => "S1988885620300286" "doi" => "10.1016/j.recote.2020.03.006" "estado" => "S300" "subdocumento" => "" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:1 [ "total" => 0 ] "idiomaDefecto" => "en" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S1988885620300286?idApp=UINPBA00004N" ] ] "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S1888441520300023?idApp=UINPBA00004N" "url" => "/18884415/0000006400000003/v1_202004190614/S1888441520300023/v1_202004190614/es/main.assets" ] ] "itemSiguiente" => array:19 [ "pii" => "S1988885620300274" "issn" => "19888856" "doi" => "10.1016/j.recote.2020.03.005" "estado" => "S300" "fechaPublicacion" => "2020-05-01" "aid" => "850" "copyright" => "SECOT" "documento" => "article" "crossmark" => 1 "subdocumento" => "fla" "cita" => "Rev Esp Cir Ortop Traumatol. 2020;64:177-84" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:1 [ "total" => 0 ] "en" => array:13 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Original Article</span>" "titulo" => "Development of a calculator to establish indications to refer patients with lumbar degenerative disease for spinal surgery consultation" "tienePdf" => "en" "tieneTextoCompleto" => "en" "tieneResumen" => array:2 [ 0 => "en" 1 => "es" ] "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "177" "paginaFinal" => "184" ] ] "titulosAlternativos" => array:1 [ "es" => array:1 [ "titulo" => "Desarrollo de una calculadora para establecer indicación de derivación a consulta de cirugía del raquis en patología degenerativa lumbar" ] ] "contieneResumen" => array:2 [ "en" => true "es" => true ] "contieneTextoCompleto" => array:1 [ "en" => true ] "contienePdf" => array:1 [ "en" => true ] "resumenGrafico" => array:2 [ "original" => 0 "multimedia" => array:7 [ "identificador" => "fig0025" "etiqueta" => "Figure 5" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr5.jpeg" "Alto" => 432 "Ancho" => 2167 "Tamanyo" => 65493 ] ] "descripcion" => array:1 [ "en" => "<p id="spar0075" class="elsevierStyleSimplePara elsevierViewall">Final calculator.</p>" ] ] ] "autores" => array:1 [ 0 => array:2 [ "autoresLista" => "M.G. Puerto-Vázquez, C. Vicario-Espinosa, J.J. Criado-Álvarez, F. Marco-Martínez" "autores" => array:4 [ 0 => array:2 [ "nombre" => "M.G." "apellidos" => "Puerto-Vázquez" ] 1 => array:2 [ "nombre" => "C." "apellidos" => "Vicario-Espinosa" ] 2 => array:2 [ "nombre" => "J.J." "apellidos" => "Criado-Álvarez" ] 3 => array:2 [ "nombre" => "F." "apellidos" => "Marco-Martínez" ] ] ] ] ] "idiomaDefecto" => "en" "Traduccion" => array:1 [ "es" => array:9 [ "pii" => "S1888441520300011" "doi" => "10.1016/j.recot.2019.12.003" "estado" => "S300" "subdocumento" => "" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:1 [ "total" => 0 ] "idiomaDefecto" => "es" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S1888441520300011?idApp=UINPBA00004N" ] ] "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S1988885620300274?idApp=UINPBA00004N" "url" => "/19888856/0000006400000003/v1_202005231742/S1988885620300274/v1_202005231742/en/main.assets" ] "itemAnterior" => array:19 [ "pii" => "S1988885620300298" "issn" => "19888856" "doi" => "10.1016/j.recote.2020.03.007" "estado" => "S300" "fechaPublicacion" => "2020-05-01" "aid" => "853" "copyright" => "SECOT" "documento" => "article" "crossmark" => 1 "subdocumento" => "fla" "cita" => "Rev Esp Cir Ortop Traumatol. 2020;64:160-6" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:1 [ "total" => 0 ] "en" => array:13 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Original Article</span>" "titulo" => "Post-traumatic clinodactyly of the little finger in Basque hand-pelota players" "tienePdf" => "en" "tieneTextoCompleto" => "en" "tieneResumen" => array:2 [ 0 => "en" 1 => "es" ] "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "160" "paginaFinal" => "166" ] ] "titulosAlternativos" => array:1 [ "es" => array:1 [ "titulo" => "Clinodactilia postraumática del meñique en el pelotari manista" ] ] "contieneResumen" => array:2 [ "en" => true "es" => true ] "contieneTextoCompleto" => array:1 [ "en" => true ] "contienePdf" => array:1 [ "en" => true ] "resumenGrafico" => array:2 [ "original" => 0 "multimedia" => array:7 [ "identificador" => "fig0015" "etiqueta" => "Figure 3" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr3.jpeg" "Alto" => 1664 "Ancho" => 1245 "Tamanyo" => 135192 ] ] "descripcion" => array:1 [ "en" => "<p id="spar0055" class="elsevierStyleSimplePara elsevierViewall">Distension of the ulnar collateral ligament of the DIP joint, untreated after repetitive trauma, developing lateral instability. The tractor effect of the insertion of the deep flexor tendon of the fingers in the distal phalange acts as a bowstring developing the deformity.</p>" ] ] ] "autores" => array:1 [ 0 => array:2 [ "autoresLista" => "A. Barriga-Martín, L.M. Romero-Muñoz, D. Aquerreta-Beola, S. Amillo-Garayoa" "autores" => array:4 [ 0 => array:2 [ "nombre" => "A." "apellidos" => "Barriga-Martín" ] 1 => array:2 [ "nombre" => "L.M." "apellidos" => "Romero-Muñoz" ] 2 => array:2 [ "nombre" => "D." "apellidos" => "Aquerreta-Beola" ] 3 => array:2 [ "nombre" => "S." "apellidos" => "Amillo-Garayoa" ] ] ] ] ] "idiomaDefecto" => "en" "Traduccion" => array:1 [ "es" => array:9 [ "pii" => "S1888441520300047" "doi" => "10.1016/j.recot.2020.01.001" "estado" => "S300" "subdocumento" => "" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:1 [ "total" => 0 ] "idiomaDefecto" => "es" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S1888441520300047?idApp=UINPBA00004N" ] ] "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S1988885620300298?idApp=UINPBA00004N" "url" => "/19888856/0000006400000003/v1_202005231742/S1988885620300298/v1_202005231742/en/main.assets" ] "en" => array:20 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Original Article</span>" "titulo" => "Description and analysis of the dynamic and morphological flow pattern of the main arteries of the wrist and hand in a healthy Spanish population" "tieneTextoCompleto" => true "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "167" "paginaFinal" => "176" ] ] "autores" => array:1 [ 0 => array:4 [ "autoresLista" => "Jaime Coderech Carretero, Fernando Corella Montoya, Miguel Grande Barez, Miguel Ángel Corella Montoya, Montserrat Ocampos Hernández, Ricardo Larrainzar-Garijo" "autores" => array:6 [ 0 => array:3 [ "nombre" => "Jaime" "apellidos" => "Coderech Carretero" "referencia" => array:1 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">a</span>" "identificador" => "aff0005" ] ] ] 1 => array:4 [ "nombre" => "Fernando" "apellidos" => "Corella Montoya" "email" => array:1 [ 0 => "Fernando.corella@gmail.com" ] "referencia" => array:4 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">b</span>" "identificador" => "aff0010" ] 1 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">c</span>" "identificador" => "aff0015" ] 2 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">d</span>" "identificador" => "aff0020" ] 3 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">*</span>" "identificador" => "cor0005" ] ] ] 2 => array:3 [ "nombre" => "Miguel" "apellidos" => "Grande Barez" "referencia" => array:1 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">e</span>" "identificador" => "aff0025" ] ] ] 3 => array:3 [ "nombre" => "Miguel Ángel" "apellidos" => "Corella Montoya" "referencia" => array:1 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">f</span>" "identificador" => "aff0030" ] ] ] 4 => array:3 [ "nombre" => "Montserrat" "apellidos" => "Ocampos Hernández" "referencia" => array:2 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">c</span>" "identificador" => "aff0015" ] 1 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">d</span>" "identificador" => "aff0020" ] ] ] 5 => array:3 [ "nombre" => "Ricardo" "apellidos" => "Larrainzar-Garijo" "referencia" => array:2 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">b</span>" "identificador" => "aff0010" ] 1 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">c</span>" "identificador" => "aff0015" ] ] ] ] "afiliaciones" => array:6 [ 0 => array:3 [ "entidad" => "Facultad de Medicina, Universidad Complutense de Madrid, Madrid, Spain" "etiqueta" => "a" "identificador" => "aff0005" ] 1 => array:3 [ "entidad" => "Departamento de Cirugía, Facultad de Medicina, Universidad Complutense de Madrid, Madrid, Spain" "etiqueta" => "b" "identificador" => "aff0010" ] 2 => array:3 [ "entidad" => "Servicio de Cirugía Ortopédica y Traumatología, Hospital Universitario Infanta Leonor, Madrid, Spain" "etiqueta" => "c" "identificador" => "aff0015" ] 3 => array:3 [ "entidad" => "Unidad de Cirugía de Mano, Hospital Universitario Quironsalud, Madrid, Spain" "etiqueta" => "d" "identificador" => "aff0020" ] 4 => array:3 [ "entidad" => "Servicio de Radiología, Hospital Universitario Infanta Leonor, Madrid, Spain" "etiqueta" => "e" "identificador" => "aff0025" ] 5 => array:3 [ "entidad" => "Área de Analytics Geoblink, Madrid, Spain" "etiqueta" => "f" "identificador" => "aff0030" ] ] "correspondencia" => array:1 [ 0 => array:3 [ "identificador" => "cor0005" "etiqueta" => "⁎" "correspondencia" => "Corresponding author." ] ] ] ] "titulosAlternativos" => array:1 [ "es" => array:1 [ "titulo" => "Descripción y análisis del patrón de normalidad de flujo dinámico y morfológico de las arterias principales de la muñeca y mano en población sana española" ] ] "resumenGrafico" => array:2 [ "original" => 0 "multimedia" => array:7 [ "identificador" => "fig0025" "etiqueta" => "Figure 5" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr5.jpeg" "Alto" => 1826 "Ancho" => 2506 "Tamanyo" => 328883 ] ] "descripcion" => array:1 [ "en" => "<p id="spar0060" class="elsevierStyleSimplePara elsevierViewall">Comparative study of the size (transverse diameter) of the digital arteries in the fingers shown in cm. (A) General comparison (with no discrimination). (B) Comparison in terms of side (right hand/left hand). (C) Comparison in terms of dominance (dominant hand/non-dominant hand). (D) Comparison in terms of gender (male/female). The asterisk indicates statistically significant differences at <span class="elsevierStyleItalic">p</span><span class="elsevierStyleHsp" style=""></span><<span class="elsevierStyleHsp" style=""></span>.05.</p>" ] ] ] "textoCompleto" => "<span class="elsevierStyleSections"><span id="sec0005" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0060">Introduction</span><p id="par0005" class="elsevierStylePara elsevierViewall">The vascular anatomy of the hand has already been widely described macroscopically. The main arteries providing blood supply to the hand are the radial artery (RA) and the ulnar artery (UA); once they reach the hand they give rise to the superficial palmar arch, which in turn emits the common and own palmar digital arteries.<a class="elsevierStyleCrossRef" href="#bib0075"><span class="elsevierStyleSup">1</span></a> There are many anatomical variations,<a class="elsevierStyleCrossRef" href="#bib0080"><span class="elsevierStyleSup">2</span></a> but the presence is constant of the radial and ulnar artery at the wrist and the ulnar and radial digital arteries at the level of each finger.</p><p id="par0010" class="elsevierStylePara elsevierViewall">In recent years, dynamic <span class="elsevierStyleItalic">in vivo</span> vascular study has been added to macroscopic vascular anatomical study thanks to ultrasound and Doppler ultrasound.<a class="elsevierStyleCrossRefs" href="#bib0085"><span class="elsevierStyleSup">3–5</span></a> This technique has generally been used to study vascularisation in impaired situations – e.g. in smokers – or to assess vascular changes when performing the Allen test.<a class="elsevierStyleCrossRefs" href="#bib0100"><span class="elsevierStyleSup">6–8</span></a> Despite all the studies carried out in impaired situations, there are very few papers that study the pattern of normality of vascularisation of the hand or vascular dominance between different arteries in a healthy population to serve as a reference.<a class="elsevierStyleCrossRefs" href="#bib0085"><span class="elsevierStyleSup">3,5,9</span></a></p><p id="par0015" class="elsevierStylePara elsevierViewall">This study aims to describe, in a healthy Spanish population, the morphological pattern and dynamic flow of the radial and ulnar arteries at the level of the wrist and of each of the digital arteries. We will also analyse the dominance of one artery (radial or ulnar) over the other in the wrist and in each of the fingers and we will analyse the influence of the laterality of the hand (right or left), dominance (right or left) and gender. In this way we expect to achieve normal values that can serve as a reference for the study of different conditions.</p></span><span id="sec0010" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0065">Material and method</span><p id="par0020" class="elsevierStylePara elsevierViewall">The study is cross-sectional, descriptive, and observational in design. To assess the variables studied by ultrasound in a healthy Spanish population, a population of 100 volunteer subjects was selected. The participants were randomly selected in different locations, mainly in the areas near the Hospital Universitario Infanta Leonor; this includes facilities such as sports centres, university centres, public offices, shops and the health facilities themselves.</p><p id="par0025" class="elsevierStylePara elsevierViewall">For the selection of the healthy population to serve as a reference and in whom a normal pattern could be estimated, people between the ages of 20 and 30 were taken as the inclusion criteria with no exclusion criteria.</p><p id="par0030" class="elsevierStylePara elsevierViewall">The exclusion criteria were the following: patients under 20 years of age or over 30, a history of high blood pressure and/or diabetes, smoking habits in the last 5 years, vascular pathology, connective tissue disease, history of inflammatory disease, systemic metabolic diseases, Raynaud's disease and a history of trauma in the forearm or hand, including from the elbow joint to the proximal interphalangeal joints.</p><p id="par0035" class="elsevierStylePara elsevierViewall">The chosen age range of the sample was between 20 and 30, since at this age growth is complete and there are usually no vascular conditions (such as arteriosclerosis) that could alter normal arterial flow. Of the 100 patients selected, 50 were men and 50 were women. The dominant hand was the right in 90 participants (45 women and 45 men) and the left in 10 (5 women and 5 men). The patients were first interviewed briefly, when they were informed of the study objectives and the reason for the questions about their medical history. After confirming that both inclusion and exclusion criteria had been met, all the participants were given an informed consent form to sign, as well as a patient information sheet referring to the research objectives and the subsequent handling of the data obtained. The study was approved by the Clinical Research Ethics Committee of the Hospital General Universitario Gregorio Marañón in Madrid (protocol code: HUIL-181025).</p><p id="par0040" class="elsevierStylePara elsevierViewall">The variables studied were the following:</p><p id="par0045" class="elsevierStylePara elsevierViewall"><span class="elsevierStyleItalic">Epidemiological and general anthropometric variables:</span> age, gender, height in cm, weight in kg, body mass index, dominant hand, considering the hand that the patient used to write as dominant.</p><p id="par0050" class="elsevierStylePara elsevierViewall"><span class="elsevierStyleItalic">Ultrasound study of the wrist and hand</span>: the variables collected in each artery were the cross-sectional diameter of the artery in cm and the flow velocity in cm/s. These parameters were measured in the wrist in the radial artery and the ulnar artery, as well as in all the radial and ulnar digital arteries specific to each finger. The GE Logiq ultrasound system from GE Health Care® was used to take the measurements, with a GE i12L-RS probe, at a frequency range of 4.0–10.0<span class="elsevierStyleHsp" style=""></span>MHz, designed for the examination of vascular structures, among others. The patients’ arms were first placed in a supination and elbow joint flexion position, with the wrist placed on a support surface to keep it relaxed.</p><p id="par0055" class="elsevierStylePara elsevierViewall">All the patients underwent an ultrasound scan of first the right upper limb and then the left upper limb.</p><p id="par0060" class="elsevierStylePara elsevierViewall">Once the hand was in position, the ultrasound settings were adjusted; mainly by activating the colour function to be able to locate the vessels and differentiate between vein and artery, and modifying the angle of the Doppler function, which should always be kept between 55° and 60°, never exceeding 60°.</p><p id="par0065" class="elsevierStylePara elsevierViewall">First, the ultrasound study was performed on the right wrist, starting with the radial artery. The proximal palmar fold was taken as a superficial anatomical reference. The probe was placed on this fold perpendicular to the forearm, with the notch of the probe facing medially at all times (<a class="elsevierStyleCrossRef" href="#fig0005">Fig. 1</a>A). In this plane, the ultrasound scan showed the radial artery accompanied by the 2 veins and the styloid process of the radius, which was the anatomical reference at ultrasound level (<a class="elsevierStyleCrossRef" href="#fig0005">Fig. 1</a>B). Once the artery had been located, minimum pressure was exerted on the wrist to avoid reducing the diameter of the vessel and the transverse diameter was measured in cm. Once the diameter had been measured, in the same plane, the probe was rotated by 90°, the notch being orientated distally (<a class="elsevierStyleCrossRef" href="#fig0005">Fig. 1</a>C). Once the rotation had been made, the longitudinal section of the artery was observed, and the flow velocity was measured. First the colour function was activated, then the <span class="elsevierStyleItalic">Steer</span> function, at all times placing the angle in favour of the vessel (from 55° to 60°) and placing the centre of the vessel in the longitudinal section as a reference. Once all this had been done, the <span class="elsevierStyleItalic">Doppler</span> function was activated and the arterial flow velocity, in both systole and diastole, was observed on the screen. By freezing the screen, if the recorded pulse was regular, the ultrasound machine marked the arterial flow velocity at the time of the systolic peak, and this value was recorded for the study (<a class="elsevierStyleCrossRef" href="#fig0005">Fig. 1</a>D). If the recorded pulse was not regular, the manoeuvre was repeated.</p><elsevierMultimedia ident="fig0005"></elsevierMultimedia><p id="par0070" class="elsevierStylePara elsevierViewall">After study of the radial artery, we continued with the ulnar artery; the superficial anatomical reference was the same as for the radial artery. The probe was placed over the fold, this time in the medial region of the wrist, perpendicular to the forearm, with the notch facing medially. However, at ultrasound level the reference was the distal epiphysis of the ulna. After taking the diameter of the artery in the transverse plane, the probe was rotated 90° and the notch was oriented distally to measure the flow velocity of the ulnar artery in the longitudinal section.</p><p id="par0075" class="elsevierStylePara elsevierViewall">Once the data collection in the arteries of the wrist was completed, the ultrasound of the finger arteries was performed. We started with the first finger at all times and in each finger, we first collected the variables of the digital radial artery and then the ulnar.</p><p id="par0080" class="elsevierStylePara elsevierViewall">To measure the arterial diameter of both the radial and the ulnar digital arteries, the proximal interphalangeal joint was taken as the anatomical reference, placing the probe proximal to it and in a perpendicular position to the proximal phalanx (<a class="elsevierStyleCrossRef" href="#fig0010">Fig. 2</a>A). In the radial digital artery (Rx, x being the finger) the probe was placed in the lateral half of the finger, while in the ulnar digital artery (Ux, x being the finger) the probe was placed in the medial half. In this plane, to facilitate locating the arteries, the colour function of the ultrasound machine was activated. Once located, the diameter of the artery was taken (<a class="elsevierStyleCrossRef" href="#fig0010">Fig. 2</a>B). For the flow velocity, the measurement was taken in the same position, proximal to the IFP joint, with the probe in a longitudinal direction (<a class="elsevierStyleCrossRef" href="#fig0010">Fig. 2</a>C). As with the arteries in the wrist, we took the flow velocity value at the systolic peak, a value indicated by the ultrasound machine (<a class="elsevierStyleCrossRef" href="#fig0010">Fig. 2</a>D).</p><elsevierMultimedia ident="fig0010"></elsevierMultimedia><p id="par0085" class="elsevierStylePara elsevierViewall">After completing the measurements in the right hand, we proceeded to take samples in the left hand following the same method.</p><p id="par0090" class="elsevierStylePara elsevierViewall">Once the abovementioned variables had been measured, the following comparative analysis was carried out:<ul class="elsevierStyleList" id="lis0005"><li class="elsevierStyleListItem" id="lsti0005"><span class="elsevierStyleLabel">•</span><p id="par0095" class="elsevierStylePara elsevierViewall">Comparative study of the size (transverse diameter) of the arteries in the wrist. The analysis was performed in 4 scenarios: in general; in relation to laterality; in relation to dominance, and in relation to gender.</p></li><li class="elsevierStyleListItem" id="lsti0010"><span class="elsevierStyleLabel">•</span><p id="par0100" class="elsevierStylePara elsevierViewall">Comparative study of the flow velocity (systolic peak) of the arteries of the wrist. Conducted in the same 4 scenarios: generally, in relation to laterality, in relation to dominance, and in relation to gender.</p></li><li class="elsevierStyleListItem" id="lsti0015"><span class="elsevierStyleLabel">•</span><p id="par0105" class="elsevierStylePara elsevierViewall">Comparative study of the size (transverse diameter) of the digital radial artery versus the digital ulnar artery in each of the five fingers generally; in each of the five fingers in relation to laterality; in each of the five fingers in relation to dominance, and in each of the five fingers in relation to gender.</p></li><li class="elsevierStyleListItem" id="lsti0020"><span class="elsevierStyleLabel">•</span><p id="par0110" class="elsevierStylePara elsevierViewall">Comparative study of the flow velocity (systolic peak) of the radial digital artery versus the ulnar digital artery in each of the five fingers generally; in each of the five fingers in relation to laterality; in each of the five fingers in relation to dominance, and in each of the five fingers in relation to gender.</p></li></ul></p><p id="par0115" class="elsevierStylePara elsevierViewall">R for Mac software (version 3.5.1; R, Vienna, Austria) was used for the statistical analysis. The descriptive values for the study of the arteries are always presented in terms of median and interquartile range (Q1–Q3). Given the large sample size available for the study and the fact that the main variables of analysis, diameter and arterial flow, are continuous quantitative, the Student's <span class="elsevierStyleItalic">t</span>-test for independent samples was used to carry out comparisons between paired groups of individuals (by gender). Similarly, when making comparisons in the same individual (in terms of side, in terms of dominance) the Student's <span class="elsevierStyleItalic">t</span>-test for paired samples was used. In all cases the level of statistical significance was set at <span class="elsevierStyleItalic">p</span><span class="elsevierStyleHsp" style=""></span><<span class="elsevierStyleHsp" style=""></span>.05.</p></span><span id="sec0015" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0070">Results</span><p id="par0120" class="elsevierStylePara elsevierViewall">The results of the descriptive study of the transverse diameter and of the arterial flow velocity at the time of the systolic peak in each of the 12 arteries studied can be seen in <a class="elsevierStyleCrossRef" href="#tbl0005">Table 1</a>.</p><elsevierMultimedia ident="tbl0005"></elsevierMultimedia><p id="par0125" class="elsevierStylePara elsevierViewall">The results of the same descriptive study broken down by right/left hand can be found in <a class="elsevierStyleCrossRef" href="#tbl0010">Table 2</a>.</p><elsevierMultimedia ident="tbl0010"></elsevierMultimedia><p id="par0130" class="elsevierStylePara elsevierViewall">The following results were obtained for the comparative analysis of the variables studied:<ul class="elsevierStyleList" id="lis0010"><li class="elsevierStyleListItem" id="lsti0025"><span class="elsevierStyleLabel">1.</span><p id="par0135" class="elsevierStylePara elsevierViewall">In the comparative study of the size (transverse diameter) of the arteries of the wrist.<ul class="elsevierStyleList" id="lis0015"><li class="elsevierStyleListItem" id="lsti0030"><span class="elsevierStyleLabel">•</span><p id="par0140" class="elsevierStylePara elsevierViewall">In general, that is, without considering laterality, dominance or gender, a larger (statistically significant) size of the radial artery is observed with respect to the ulnar artery (<a class="elsevierStyleCrossRef" href="#fig0015">Fig. 3</a>A).</p><elsevierMultimedia ident="fig0015"></elsevierMultimedia></li><li class="elsevierStyleListItem" id="lsti0035"><span class="elsevierStyleLabel">•</span><p id="par0145" class="elsevierStylePara elsevierViewall">In terms of laterality, the tendency is the same as described above, with a larger (statistically significant) size of the radial artery in both the right and left wrist (<a class="elsevierStyleCrossRef" href="#fig0015">Fig. 3</a>B).</p></li><li class="elsevierStyleListItem" id="lsti0040"><span class="elsevierStyleLabel">•</span><p id="par0150" class="elsevierStylePara elsevierViewall">In terms of dominance, there is no statistically significant difference between the size of the radial ulnar arteries of the dominant hand and the size of the same arteries in the non-dominant wrist (<a class="elsevierStyleCrossRef" href="#fig0015">Fig. 3</a>C).</p></li><li class="elsevierStyleListItem" id="lsti0045"><span class="elsevierStyleLabel">•</span><p id="par0155" class="elsevierStylePara elsevierViewall">In terms of gender, the two arteries in the wrist were found to be statistically significantly larger in the men than in the women (<a class="elsevierStyleCrossRef" href="#fig0015">fig. 3</a>D).</p></li></ul></p></li><li class="elsevierStyleListItem" id="lsti0050"><span class="elsevierStyleLabel">2.</span><p id="par0160" class="elsevierStylePara elsevierViewall">In the comparative study of the flow velocity (systolic peak) of the arteries of the wrist.<ul class="elsevierStyleList" id="lis0020"><li class="elsevierStyleListItem" id="lsti0055"><span class="elsevierStyleLabel">•</span><p id="par0165" class="elsevierStylePara elsevierViewall">In general. A higher (statistically significant) flow was observed of the ulnar artery with respect to the radial artery (<a class="elsevierStyleCrossRef" href="#fig0020">Fig. 4</a>A).</p><elsevierMultimedia ident="fig0020"></elsevierMultimedia></li><li class="elsevierStyleListItem" id="lsti0060"><span class="elsevierStyleLabel">•</span><p id="par0170" class="elsevierStylePara elsevierViewall">In terms of laterality, the trend was the same, with greater flow of the ulnar artery (statistically significant) in both the right and the left wrist (<a class="elsevierStyleCrossRef" href="#fig0020">Fig. 4</a>B).</p></li><li class="elsevierStyleListItem" id="lsti0065"><span class="elsevierStyleLabel">•</span><p id="par0175" class="elsevierStylePara elsevierViewall">In terms of dominance, no statistically significant differences were observed between the radial and ulnar artery flow of the dominant hand with respect to the same arteries in the non-dominant hand (<a class="elsevierStyleCrossRef" href="#fig0020">Fig. 4</a>C).</p></li><li class="elsevierStyleListItem" id="lsti0070"><span class="elsevierStyleLabel">•</span><p id="par0180" class="elsevierStylePara elsevierViewall">In terms of gender, it was observed that in both arteries the flow is statistically significantly higher in the men than in the women (<a class="elsevierStyleCrossRef" href="#fig0020">Fig. 4</a>D).</p></li></ul></p></li><li class="elsevierStyleListItem" id="lsti0075"><span class="elsevierStyleLabel">3.</span><p id="par0185" class="elsevierStylePara elsevierViewall">In the comparative study of the size (transverse diameter) of the digital arteries in the fingers:<ul class="elsevierStyleList" id="lis0025"><li class="elsevierStyleListItem" id="lsti0080"><span class="elsevierStyleLabel">•</span><p id="par0190" class="elsevierStylePara elsevierViewall">In general, it was observed that in the first, second and third fingers the digital ulnar artery was larger (statistically significant) than the digital radial artery. In the fourth and fifth fingers, the digital radial artery was larger (statistically significant) than the digital ulnar artery (<a class="elsevierStyleCrossRef" href="#fig0025">Fig. 5</a>A).</p><elsevierMultimedia ident="fig0025"></elsevierMultimedia></li><li class="elsevierStyleListItem" id="lsti0085"><span class="elsevierStyleLabel">•</span><p id="par0195" class="elsevierStylePara elsevierViewall">In terms of laterality, the trend was the same. Larger diameter of the digital ulnar artery in the first, second and third fingers, and larger diameter of the digital radial artery in the fourth and fifth fingers, both in the right and left hand (<a class="elsevierStyleCrossRef" href="#fig0025">Fig. 5</a>B).</p></li><li class="elsevierStyleListItem" id="lsti0090"><span class="elsevierStyleLabel">•</span><p id="par0200" class="elsevierStylePara elsevierViewall">In terms of dominance, no statistically significant differences were observed between the digital radial and ulnar arteries of each finger of the dominant hand compared to the digital arteries of the same fingers in the non-dominant hand (<a class="elsevierStyleCrossRef" href="#fig0025">Fig. 5</a>C).</p></li><li class="elsevierStyleListItem" id="lsti0095"><span class="elsevierStyleLabel">•</span><p id="par0205" class="elsevierStylePara elsevierViewall">In terms of gender, both the digital radial and digital ulnar arteries of the 5 fingers were found to be larger in the men than in the women (<a class="elsevierStyleCrossRef" href="#fig0025">Fig. 5</a>D).</p></li></ul></p></li><li class="elsevierStyleListItem" id="lsti0100"><span class="elsevierStyleLabel">4.</span><p id="par0210" class="elsevierStylePara elsevierViewall">In the comparative study of the flow velocity (systolic peak) of the digital arteries in the fingers:<ul class="elsevierStyleList" id="lis0030"><li class="elsevierStyleListItem" id="lsti0105"><span class="elsevierStyleLabel">•</span><p id="par0215" class="elsevierStylePara elsevierViewall">In general, it was observed that in the first, second and third fingers the flow of the digital ulnar artery was greater compared to the digital radial artery. However, in the fourth and fifth fingers it was observed that the flow of the digital radial artery was greater in comparison to the digital ulnar artery, all of these results being statistically significant (<a class="elsevierStyleCrossRef" href="#fig0030">Fig. 6</a>A).</p><elsevierMultimedia ident="fig0030"></elsevierMultimedia></li><li class="elsevierStyleListItem" id="lsti0110"><span class="elsevierStyleLabel">•</span><p id="par0220" class="elsevierStylePara elsevierViewall">In terms of laterality, the trend was the same. With greater flow of the digital ulnar artery in the first, second and third fingers and greater flow of the digital radial artery in the fourth and fifth fingers, in both the right and left hand (<a class="elsevierStyleCrossRef" href="#fig0030">Fig. 6</a>B).</p></li><li class="elsevierStyleListItem" id="lsti0115"><span class="elsevierStyleLabel">•</span><p id="par0225" class="elsevierStylePara elsevierViewall">In terms of dominance, no statistically significant differences were observed between the digital radial and ulnar arteries of each finger of the dominant hand with respect to the digital arteries of the same fingers of the non-dominant hand (<a class="elsevierStyleCrossRef" href="#fig0030">Fig. 6</a>C).</p></li><li class="elsevierStyleListItem" id="lsti0120"><span class="elsevierStyleLabel">•</span><p id="par0230" class="elsevierStylePara elsevierViewall">In terms of gender, it was observed that the flow of the arteries, both digital radial and digital ulnar of the 5 fingers, was greater in the men than in the women (<a class="elsevierStyleCrossRef" href="#fig0030">Fig. 6</a>D).</p></li></ul></p></li></ul></p></span><span id="sec0020" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0075">Discussion</span><p id="par0235" class="elsevierStylePara elsevierViewall">In this study describe the normal flow pattern of the radial and ulnar arteries of the wrist and the radial and ulnar digital arteries of each finger in a healthy Spanish population. In general terms, we observed that, regardless of the variables studied, at the level of the wrist the radial artery is of a greater size. However, it is the ulnar artery that presented flow dominance at this level. At finger level, we observed that in the first, second and third fingers it is the ulnar digital artery that presents a greater size, as well as flow dominance, over the radial digital artery. However, in the fourth and fifth fingers the digital radial artery was shown to be of greater size and flow dominance compared to the digital ulnar artery.</p><p id="par0240" class="elsevierStylePara elsevierViewall">Regarding the ultrasound study of the size of the arteries of the wrist, in the current literature there are several studies that focus on the comparative analysis between the radial and ulnar arteries, with different conclusions. Ashraf et al.<a class="elsevierStyleCrossRef" href="#bib0115"><span class="elsevierStyleSup">9</span></a> establish that the ulnar artery is larger in size than the radial. However, other studies conclude that the radial artery is larger at the wrist,<a class="elsevierStyleCrossRefs" href="#bib0085"><span class="elsevierStyleSup">3–5</span></a> or that they find no significant differences in sizes.<a class="elsevierStyleCrossRef" href="#bib0120"><span class="elsevierStyleSup">10</span></a> Some of these studies also compared the size of these arteries according to laterality, and found no differences between the arteries of the right and left wrist,<a class="elsevierStyleCrossRef" href="#bib0085"><span class="elsevierStyleSup">3</span></a> or differences between the dominant and non-dominant hand,<a class="elsevierStyleCrossRefs" href="#bib0090"><span class="elsevierStyleSup">4,10</span></a> but found a larger size of the radial artery in men compared to women.<a class="elsevierStyleCrossRefs" href="#bib0090"><span class="elsevierStyleSup">4,10</span></a> In our study we observed that, regardless of the discriminated variable, the size of the radial artery is always larger than the ulnar artery, in contrast to some of the abovementioned studies. In terms of laterality, we also found no differences in arterial size when comparing right and left hands. Similarly, we found no differences in terms of dominance. Finally, on analysing size in terms of gender, we did find statistically significant differences in the size of both the radial and ulnar arteries, which were larger in the men. To explain the difference in the results, we should mention that our sample was obtained from completely healthy patients, with demanding exclusion criteria, while many of these studies included a populations with diseases that could impair vascularisation.</p><p id="par0245" class="elsevierStylePara elsevierViewall">The arterial flow in the arteries of the wrist has also been studied in several papers. There are studies describing a flow pattern in which the ulnar artery is the dominant artery in the wrist<a class="elsevierStyleCrossRefs" href="#bib0090"><span class="elsevierStyleSup">4,11</span></a>; however, we also found studies describing a pattern of radial dominance.<a class="elsevierStyleCrossRefs" href="#bib0085"><span class="elsevierStyleSup">3,12</span></a> It seems that radial dominance is more likely in patients who smoke, since in smokers the ulnar artery is most affected.<a class="elsevierStyleCrossRef" href="#bib0130"><span class="elsevierStyleSup">12</span></a> The harmful effect of smoking on the circulation of the hand is known,<a class="elsevierStyleCrossRefs" href="#bib0135"><span class="elsevierStyleSup">13,14</span></a> and finding radial dominance in patients who smoke does not go against our study, in which smoking was a criterion for exclusion. In our study it was observed that, in the wrist, the ulnar artery is dominant over the radial artery; our findings coincide with the first studies mentioned. If we take laterality into account, there are no marked differences between the flow of the left and right hand, the ulnar artery being the dominant artery in both hands. No previous studies of arterial flow in the wrist have been described that consider dominance, and in our study no statistically significant differences were observed between the flow from the dominant and the non-dominant hand. Finally, when considering gender, blood flow at the wrist was found to be higher in the men than in the women. Probably one of the most curious data of this study is the discrepancy between the size and flow of the radial and ulnar arteries, since, in spite of the larger size of the radial artery, the flow is less.</p><p id="par0250" class="elsevierStylePara elsevierViewall">Regarding the size of the radial and ulnar digital arteries of each finger, the only article we found that studies the size of the digital vessels ultrasonically is the one by Trager et al.<a class="elsevierStyleCrossRef" href="#bib0125"><span class="elsevierStyleSup">11</span></a> on 20 patients. They describe that the ulnar artery of the first, second and third fingers is larger than the radial, while the radial artery of the fourth and fifth fingers is the largest. The same results were obtained in our study.</p><p id="par0255" class="elsevierStylePara elsevierViewall">Finally, our last comparative analysis refers to the flow of the digital arteries in the fingers. Similarly, the only article we found that studies the flow velocity of the digital arteries is that of Trager et al.<a class="elsevierStyleCrossRef" href="#bib0125"><span class="elsevierStyleSup">11</span></a> They describe a greater flow in the arteries with a larger diameter, i.e. the ulnar of the first to the third fingers and the radial of the fourth and fifth fingers. In our study of 200 hands and 1000 fingers we found the same results. We were able to make a heat map in which the flow in each of the arteries of the fingers can be seen graphically (<a class="elsevierStyleCrossRef" href="#fig0035">Fig. 7</a>).</p><elsevierMultimedia ident="fig0035"></elsevierMultimedia><p id="par0260" class="elsevierStylePara elsevierViewall">As a limitation of the study, we should point out that the measurements were made by a single scanner (always the same one), but the measurements were not compared between two different scanners for interobserver validation.</p><p id="par0265" class="elsevierStylePara elsevierViewall">As a curiosity, it is worth noting that the size and flow is less in areas of the fingers “less protected from injury” and where greater support is provided, such as the ulnar area of the fourth and fifth fingers and the radial area of the first, second and third fingers, while the arteries in the more protected areas provide greater vascular support. This has a completely logical evolutionary explanation in which the vascular contribution of the finger is protected, giving greater importance to the arteries that have less risk of injury.</p></span><span id="sec0025" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0080">Conclusion</span><p id="par0270" class="elsevierStylePara elsevierViewall">The pattern of normal flow of the radial and ulnar arteries of the wrist and the radial and ulnar digital arteries of each finger in a healthy Spanish population has been described. In general terms, we observed that, regardless of the variables studied, at wrist level the radial arteries are greater in size. However, it is the ulnar artery that presented flow dominance at this level. At finger level, we observed that in the first, second and third fingers it is the ulnar digital artery that was larger in size, as well as flow dominance, than the radial digital artery of these fingers. However, in the fourth and fifth fingers we found that it is the digital radial artery that is larger in size and flow dominance compared to the digital ulnar artery of the same fingers. It can be concluded that there is a greater size and flow of the arteries in the areas of the fingers most protected from injury (ulnar area of the first, second and third fingers and radial area of the fourth and fifth) and a smaller size and flow in the areas of greater support and probability of injury (radial area of the first, second and third fingers and ulnar area of the fourth and fifth).</p></span><span id="sec0030" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0085">Level of evidence</span><p id="par0275" class="elsevierStylePara elsevierViewall">Level of evidence III.</p></span><span id="sec0035" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0090">Conflict of interests</span><p id="par0280" class="elsevierStylePara elsevierViewall">The authors have no conflict of interests to declare.</p></span></span>" "textoCompletoSecciones" => array:1 [ "secciones" => array:12 [ 0 => array:3 [ "identificador" => "xres1338947" "titulo" => "Abstract" "secciones" => array:3 [ 0 => array:2 [ "identificador" => "abst0005" "titulo" => "Background and aim" ] 1 => array:2 [ "identificador" => "abst0010" "titulo" => "Material and method" ] 2 => array:2 [ "identificador" => "abst0015" "titulo" => "Results" ] ] ] 1 => array:2 [ "identificador" => "xpalclavsec1232694" "titulo" => "Keywords" ] 2 => array:3 [ "identificador" => "xres1338948" "titulo" => "Resumen" "secciones" => array:4 [ 0 => array:2 [ "identificador" => "abst0020" "titulo" => "Antecedentes y objetivo" ] 1 => array:2 [ "identificador" => "abst0025" "titulo" => "Material y método" ] 2 => array:2 [ "identificador" => "abst0030" "titulo" => "Resultados" ] 3 => array:2 [ "identificador" => "abst0035" "titulo" => "Conclusión" ] ] ] 3 => array:2 [ "identificador" => "xpalclavsec1232695" "titulo" => "Palabras clave" ] 4 => array:2 [ "identificador" => "sec0005" "titulo" => "Introduction" ] 5 => array:2 [ "identificador" => "sec0010" "titulo" => "Material and method" ] 6 => array:2 [ "identificador" => "sec0015" "titulo" => "Results" ] 7 => array:2 [ "identificador" => "sec0020" "titulo" => "Discussion" ] 8 => array:2 [ "identificador" => "sec0025" "titulo" => "Conclusion" ] 9 => array:2 [ "identificador" => "sec0030" "titulo" => "Level of evidence" ] 10 => array:2 [ "identificador" => "sec0035" "titulo" => "Conflict of interests" ] 11 => array:1 [ "titulo" => "References" ] ] ] "pdfFichero" => "main.pdf" "tienePdf" => true "fechaRecibido" => "2019-08-17" "fechaAceptado" => "2019-12-21" "PalabrasClave" => array:2 [ "en" => array:1 [ 0 => array:4 [ "clase" => "keyword" "titulo" => "Keywords" "identificador" => "xpalclavsec1232694" "palabras" => array:5 [ 0 => "Radial artery" 1 => "Ulnar artery" 2 => "Doppler-colour ultrasound" 3 => "Digital arteries" 4 => "Reference values" ] ] ] "es" => array:1 [ 0 => array:4 [ "clase" => "keyword" "titulo" => "Palabras clave" "identificador" => "xpalclavsec1232695" "palabras" => array:5 [ 0 => "Arteria radial" 1 => "Arteria ulnar" 2 => "Ecografía Doppler-color" 3 => "Arterias digitales" 4 => "Valores de referencia" ] ] ] ] "tieneResumen" => true "resumen" => array:2 [ "en" => array:3 [ "titulo" => "Abstract" "resumen" => "<span id="abst0005" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0010">Background and aim</span><p id="spar0005" class="elsevierStyleSimplePara elsevierViewall">The vascular anatomy of the hand has already been widely described macroscopically. However, there are very few papers that study the pattern of normality of <span class="elsevierStyleItalic">in vivo</span> vascularisation that describe and analyse the main arteries of the hand. The aim of this paper was to carry out a study to serve as a reference for the normal values of size and flow of the radial and ulnar artery at the level of the wrist, and the digital radial and ulnar arteries at the level of the fingers.</p></span> <span id="abst0010" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0015">Material and method</span><p id="spar0010" class="elsevierStyleSimplePara elsevierViewall">A descriptive observational cross-sectional study on 200 hands in 100 healthy volunteers aged between 20 and 30 years. Doppler-colour ultrasound was performed on the ulnar and radial arteries in the wrist, as well as on the radial and ulnar digital arteries in each finger. Once the measurements had been taken, a general comparative analysis was performed also taking laterality, dominance and gender into account.</p></span> <span id="abst0015" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0020">Results</span><p id="spar0015" class="elsevierStyleSimplePara elsevierViewall">It was observed that the radial artery is larger in size than the ulnar at wrist level, however, it was the ulnar artery that showed flow dominance at this level. At finger level, the arteries are greater in size and flow in the areas of the fingers more protected from injury (digital ulnar artery in the first three and radial artery in the fourth and fifth digits).</p></span>" "secciones" => array:3 [ 0 => array:2 [ "identificador" => "abst0005" "titulo" => "Background and aim" ] 1 => array:2 [ "identificador" => "abst0010" "titulo" => "Material and method" ] 2 => array:2 [ "identificador" => "abst0015" "titulo" => "Results" ] ] ] "es" => array:3 [ "titulo" => "Resumen" "resumen" => "<span id="abst0020" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0030">Antecedentes y objetivo</span><p id="spar0020" class="elsevierStyleSimplePara elsevierViewall">La anatomía vascular de la mano ya ha sido ampliamente descrita a nivel macroscópico. Sin embargo, existen muy pocos trabajos que estudien el patrón de normalidad de la vascularización <span class="elsevierStyleItalic">in vivo</span> y describan y analicen las arterias principales de la mano. El objetivo de este trabajo es realizar un estudio que sirva de referencia para los valores normales de tamaño y flujo de la arteria radial y ulnar a nivel de la muñeca y de las arterias digitales radiales y ulnares a nivel de los dedos.</p></span> <span id="abst0025" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0035">Material y método</span><p id="spar0025" class="elsevierStyleSimplePara elsevierViewall">Estudio descriptivo observacional de corte trasversal sobre 200 manos en 100 voluntarios sanos entre 20-30<span class="elsevierStyleHsp" style=""></span>años. Se realizó ecografía Doppler-color de las arterias ulnar y radial en la muñeca, así como de las arterias digitales radial y ulnar de cada dedo. Una vez tomadas las medidas se llevó a cabo un análisis comparativo de forma general y también teniendo en cuenta la lateralidad, la dominancia y el género.</p></span> <span id="abst0030" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0040">Resultados</span><p id="spar0030" class="elsevierStyleSimplePara elsevierViewall">Se observó que existe un mayor tamaño de la arteria radial sobre la ulnar a nivel de la muñeca; sin embargo, es la arteria ulnar la que presentó dominancia de flujo a este nivel. A nivel de los dedos, en los tres primeros fue la arteria digital ulnar la que presentó un mayor tamaño y mayor flujo. No obstante, en el cuarto y quinto dedos fue la arteria digital radial la que presentó un mayor tamaño y dominancia de flujo.</p></span> <span id="abst0035" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0045">Conclusión</span><p id="spar0035" class="elsevierStyleSimplePara elsevierViewall">Ha quedado confirmado que la dominancia de flujo, pero no de tamaño, a nivel de la muñeca es de la arteria ulnar. A nivel de los dedos, existe un mayor tamaño y flujo de las arterias en las zonas de los dedos más protegidas de las lesiones (arteria digital ulnar en los tres primeros y radial en el cuarto y quinto).</p></span>" "secciones" => array:4 [ 0 => array:2 [ "identificador" => "abst0020" "titulo" => "Antecedentes y objetivo" ] 1 => array:2 [ "identificador" => "abst0025" "titulo" => "Material y método" ] 2 => array:2 [ "identificador" => "abst0030" "titulo" => "Resultados" ] 3 => array:2 [ "identificador" => "abst0035" "titulo" => "Conclusión" ] ] ] ] "NotaPie" => array:1 [ 0 => array:2 [ "etiqueta" => "☆" "nota" => "<p class="elsevierStyleNotepara" id="npar0005">Please cite this article as: Coderech Carretero J, Corella Montoya F, Grande Barez M, Corella Montoya MÁ, Ocampos Hernández M, Larrainzar-Garijo R. Descripción y análisis del patrón de normalidad de flujo dinámico y morfológico de las arterias principales de la muñeca y mano en población sana española. Rev Esp Cir Ortop Traumatol. 2020;64:167–176.</p>" ] ] "multimedia" => array:9 [ 0 => array:7 [ "identificador" => "fig0005" "etiqueta" => "Figure 1" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr1.jpeg" "Alto" => 1109 "Ancho" => 1298 "Tamanyo" => 154347 ] ] "descripcion" => array:1 [ "en" => "<p id="spar0040" class="elsevierStyleSimplePara elsevierViewall">(A) Procedure for measuring the diameter of the radial artery of the right wrist. Measured at the level of the proximal palmar fold. The probe is placed transversely to locate the artery (arrow) and the measurement is taken using the styloid of the radius as a reference (asterisk). (B) Procedure to measure the flow velocity of the radial artery of the right wrist. Measured at the level of the proximal palmar fold. The probe is placed longitudinally to locate the artery (white arrow) and the peak systolic value is taken if the pulse was regular (yellow arrow).</p>" ] ] 1 => array:7 [ "identificador" => "fig0010" "etiqueta" => "Figure 2" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr2.jpeg" "Alto" => 1101 "Ancho" => 1297 "Tamanyo" => 139286 ] ] "descripcion" => array:1 [ "en" => "<p id="spar0045" class="elsevierStyleSimplePara elsevierViewall">(A) Procedure for measuring the diameter of the ulnar digital artery of the third finger of the right hand. Measured proximal to the IFP joint. The probe is placed transversely to locate the artery adjacent to the flexor tendons (asterisk). (B) Procedure for measuring the flow velocity of the ulnar digital artery of the third finger of the right hand. Measured proximal to the IFP joint. The probe is placed longitudinally to locate the artery and the systolic peak value is taken if the pulse was regular (yellow arrow).</p>" ] ] 2 => array:7 [ "identificador" => "fig0015" "etiqueta" => "Figure 3" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr3.jpeg" "Alto" => 2613 "Ancho" => 2500 "Tamanyo" => 390195 ] ] "descripcion" => array:1 [ "en" => "<p id="spar0050" class="elsevierStyleSimplePara elsevierViewall">Comparative study of the size (transverse diameter) of the radial and ulnar arteries at wrist level shown in cm. (A) General comparison (with no discrimination). (B) Comparison in terms of side (right wrist/left wrist). (C) Comparison in terms of dominance (dominant hand/non-dominant hand). (D) Comparison in terms of gender (male/female). The asterisk indicates statistically significant differences at <span class="elsevierStyleItalic">p</span><span class="elsevierStyleHsp" style=""></span><<span class="elsevierStyleHsp" style=""></span>.05.</p>" ] ] 3 => array:7 [ "identificador" => "fig0020" "etiqueta" => "Figure 4" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr4.jpeg" "Alto" => 2621 "Ancho" => 2506 "Tamanyo" => 385177 ] ] "descripcion" => array:1 [ "en" => "<p id="spar0055" class="elsevierStyleSimplePara elsevierViewall">Comparative study of flow velocity (systolic peak) of the arteries of the wrist shown in cm/s. (A) General comparison (with no discrimination). (B) Comparison in terms of side (right wrist/left wrist). (C) Comparison in terms of dominance (dominant hand/non-dominant hand). (D) Comparison in terms of gender (male/female). The asterisk indicates statistically significant differences at <span class="elsevierStyleItalic">p</span><span class="elsevierStyleHsp" style=""></span><<span class="elsevierStyleHsp" style=""></span>.05.</p>" ] ] 4 => array:7 [ "identificador" => "fig0025" "etiqueta" => "Figure 5" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr5.jpeg" "Alto" => 1826 "Ancho" => 2506 "Tamanyo" => 328883 ] ] "descripcion" => array:1 [ "en" => "<p id="spar0060" class="elsevierStyleSimplePara elsevierViewall">Comparative study of the size (transverse diameter) of the digital arteries in the fingers shown in cm. (A) General comparison (with no discrimination). (B) Comparison in terms of side (right hand/left hand). (C) Comparison in terms of dominance (dominant hand/non-dominant hand). (D) Comparison in terms of gender (male/female). The asterisk indicates statistically significant differences at <span class="elsevierStyleItalic">p</span><span class="elsevierStyleHsp" style=""></span><<span class="elsevierStyleHsp" style=""></span>.05.</p>" ] ] 5 => array:7 [ "identificador" => "fig0030" "etiqueta" => "Figure 6" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr6.jpeg" "Alto" => 1826 "Ancho" => 2506 "Tamanyo" => 381973 ] ] "descripcion" => array:1 [ "en" => "<p id="spar0065" class="elsevierStyleSimplePara elsevierViewall">Comparative study of the flow velocity (systolic peak) of the digital arteries in the fingers shown in cm/s. (A) General comparison (with no discrimination). (B) Comparison in terms of side (right hand/left hand). (C) Comparison in terms of dominance (dominant hand/non-dominant hand). (D) Comparison in terms of gender (male/female). The asterisk indicates statistically significant differences at <span class="elsevierStyleItalic">p</span><span class="elsevierStyleHsp" style=""></span><<span class="elsevierStyleHsp" style=""></span>.05.</p>" ] ] 6 => array:7 [ "identificador" => "fig0035" "etiqueta" => "Figure 7" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr7.jpeg" "Alto" => 1296 "Ancho" => 1591 "Tamanyo" => 97401 ] ] "descripcion" => array:1 [ "en" => "<p id="spar0070" class="elsevierStyleSimplePara elsevierViewall">Heat map reflecting the flow for each digital artery. The colour shown is adjusted to the median obtained for the flow velocity of each artery.</p>" ] ] 7 => array:8 [ "identificador" => "tbl0005" "etiqueta" => "Table 1" "tipo" => "MULTIMEDIATABLA" "mostrarFloat" => true "mostrarDisplay" => false "detalles" => array:1 [ 0 => array:3 [ "identificador" => "at1" "detalle" => "Table " "rol" => "short" ] ] "tabla" => array:2 [ "leyenda" => "<p id="spar0080" class="elsevierStyleSimplePara elsevierViewall">Rx: radial digital artery of finger x; Ux: ulnar digital artery of finger x.</p><p id="spar0085" class="elsevierStyleSimplePara elsevierViewall">Results of the 200 hands studied, shown as median (Med) and interquartile range (IQR).</p>" "tablatextoimagen" => array:1 [ 0 => array:2 [ "tabla" => array:1 [ 0 => """ <table border="0" frame="\n \t\t\t\t\tvoid\n \t\t\t\t" class=""><thead title="thead"><tr title="table-row"><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black"> \t\t\t\t\t\t\n \t\t\t\t\t\t</th><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">Transverse diameter (cm) \t\t\t\t\t\t\n \t\t\t\t\t\t</th><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">Flow velocity (cm/s) \t\t\t\t\t\t\n \t\t\t\t\t\t</th></tr></thead><tbody title="tbody"><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Med radial (RIQ) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">.24 (.22–.28) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">48 (39.49–62.3175) \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Med ulnar (RIQ) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">.22 (.1875–.25) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">54.2 (39.145–70.46) \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Med U1 (RIQ) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">.09 (.08–.11) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">30.52 (19.2675–44.13) \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Med R2 (RIQ) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">.08 (.0775–.1) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">17.57 (13.16–24.78) \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Med U2 (RIQ) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">.1 (.08–.11) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">27.71 (17.615–37.3225) \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Med R3 (RIQ) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">.09 (.08–.1) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">21.68 (15.31–30.97) \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Med U3 (RIQ) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">.1 (.08–.11) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">25.55 (17.03–34.8325) \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Med R4 (RIQ) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">.09 (.08–.11) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">25.17 (16.525–34.66) \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Med U4 (RIQ) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">.09 (.08–.1) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">19.36 (13.94–26.32) \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Med R5 (RIQ) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">.09 (.08–.1) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">21.68 (15.0275–21.184) \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Med U5 (RIQ) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">.08 (.07–.09) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">15.3 (11.61–17.1041) \t\t\t\t\t\t\n \t\t\t\t</td></tr></tbody></table> """ ] "imagenFichero" => array:1 [ 0 => "xTab2296149.png" ] ] ] ] "descripcion" => array:1 [ "en" => "<p id="spar0075" class="elsevierStyleSimplePara elsevierViewall">Results of the diameter (in centimetres) and flow velocity (in centimetres/second) of the radial artery (radial) and ulnar artery (ulnar) in the wrist and of the radial and ulnar digital arteries of the five fingers.</p>" ] ] 8 => array:8 [ "identificador" => "tbl0010" "etiqueta" => "Table 2" "tipo" => "MULTIMEDIATABLA" "mostrarFloat" => true "mostrarDisplay" => false "detalles" => array:1 [ 0 => array:3 [ "identificador" => "at2" "detalle" => "Table " "rol" => "short" ] ] "tabla" => array:1 [ "tablatextoimagen" => array:1 [ 0 => array:2 [ "tabla" => array:1 [ 0 => """ <table border="0" frame="\n \t\t\t\t\tvoid\n \t\t\t\t" class=""><thead title="thead"><tr title="table-row"><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col"> \t\t\t\t\t\t\n \t\t\t\t\t\t</th><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " colspan="2" align="center" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">Right</th><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " colspan="2" align="center" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">Left</th></tr><tr title="table-row"><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black"> \t\t\t\t\t\t\n \t\t\t\t\t\t</th><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">Transverse diameter (cm) \t\t\t\t\t\t\n \t\t\t\t\t\t</th><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">Flow velocity (cm/s) \t\t\t\t\t\t\n \t\t\t\t\t\t</th><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">Transverse diameter (cm) \t\t\t\t\t\t\n \t\t\t\t\t\t</th><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">Flow velocity (cm/s) \t\t\t\t\t\t\n \t\t\t\t\t\t</th></tr></thead><tbody title="tbody"><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Med radial (RIQ) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">.24 (.22–.28) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">49.92 (40.0675–65.4275) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">.25 (.2175–.27) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">47.23 (38.71–61.0575) \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Med ulnar (RIQ) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">.22 (.1875–.25) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">54.47 (39.49–70.5475) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">.22 (.1875–.24) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">53.88 (37.16–69.7175) \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Med R1 (RIQ) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">.08 (.08–.1) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">19.91 (13.94–28.8425) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">.08 (.07–.09) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">19.38 (13.0675–26.42) \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Med U1 (RIQ) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">.09 (.08–.11) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">31.74 (18.58–44.13) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">.09 (.08–.1125) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">29.81 (19.36–44.3125) \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Med R2 (RIQ) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">.09 (.08–.1) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">17.81 (13.4975–24.78) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">.08 (.07–.1) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">16.72 (13.16–24.785) \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Med U2 (RIQ) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">.1 (.08–.11) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">28.87 (18.3875–37.94) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">.1 (.08–.1125) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">27.1 (17.03–37.16) \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Med R3 (RIQ) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">.09 (.08–.11) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">22.45 (16.26–31.0625) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">.09 (.08–.1) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">20.13 (14.71–29.705) \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Med U3 (RIQ) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">.1 (.09–.11) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">27.99 (17.465–35.9625) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">.1 (.08–.12) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">24.78 (17.03–33.4975) \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Med R4 (RIQ) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">.09 (.08–.1) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">24.39 (16.5–33.46) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">.1 (.08–.11) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">25.67 (16.8625–34-84) \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Med U4 (RIQ) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">.09 (.08–.1) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">20.58 (14.71–26.5325) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">.09 (.08–.1) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">17.61 (13.7775–25.7425) \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Med R5 (RIQ) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">.09 (.08–.1) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">21.68 (15.49–30.7) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">.09 (.08–.1) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">21.29 (14.5175–33.29) \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Med U5 (RIQ) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">.08 (.07–.09) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">15.49 (12.39–21.095) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">.08 (.07–.09) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="char" valign="\n \t\t\t\t\ttop\n \t\t\t\t">14.59 (11.61–19.5425) \t\t\t\t\t\t\n \t\t\t\t</td></tr></tbody></table> """ ] "imagenFichero" => array:1 [ 0 => "xTab2296150.png" ] ] ] ] "descripcion" => array:1 [ "en" => "<p id="spar0090" class="elsevierStyleSimplePara elsevierViewall">Results of the diameter (in centimetres) and flow velocity (in centimetres/second) of the 100 right hands and 100 left hands.</p>" ] ] ] "bibliografia" => array:2 [ "titulo" => "References" "seccion" => array:1 [ 0 => array:2 [ "identificador" => "bibs0015" "bibliografiaReferencia" => array:14 [ 0 => array:3 [ "identificador" => "bib0075" "etiqueta" => "1" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Anatomía humana: descriptiva, topográfica y funcional" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:2 [ 0 => "H. Rouviére" 1 => "A. Delmas" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Libro" => array:4 [ "edicion" => "11.<span class="elsevierStyleSup">a</span> ed." "fecha" => "2005" "editorial" => "Masson" "editorialLocalizacion" => "Barcelona" ] ] ] ] ] ] 1 => array:3 [ "identificador" => "bib0080" "etiqueta" => "2" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "A morphometric study on the superficial palmar arch of the hand" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:4 [ 0 => "O. Bilge" 1 => "Y. Pinar" 2 => "M.A. Ozer" 3 => "F. Gövsa" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1007/s00276-006-0109-9" "Revista" => array:6 [ "tituloSerie" => "Surg Radiol Anat" "fecha" => "2006" "volumen" => "28" "paginaInicial" => "343" "paginaFinal" => "350" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/16642281" "web" => "Medline" ] ] ] ] ] ] ] ] 2 => array:3 [ "identificador" => "bib0085" "etiqueta" => "3" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Dominancia vascular en la mano: Estudio dinámico de flujos" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:2 [ 0 => "C. Torres" 1 => "A. Sastre" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:5 [ "tituloSerie" => "Rev Iberam Cir Mano" "fecha" => "2017" "volumen" => "45" "paginaInicial" => "28" "paginaFinal" => "34" ] ] ] ] ] ] 3 => array:3 [ "identificador" => "bib0090" "etiqueta" => "4" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Flow and diameter changes of forearm arteries during temporary unilateral reciprocal occlusion: a prospective observational study" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:2 [ 0 => "H. Kaplanoglu" 1 => "O. Beton" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1002/jcu.22440" "Revista" => array:6 [ "tituloSerie" => "J Clin Ultrasound" "fecha" => "2017" "volumen" => "45" "paginaInicial" => "197" "paginaFinal" => "203" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/28164311" "web" => "Medline" ] ] ] ] ] ] ] ] 4 => array:3 [ "identificador" => "bib0095" "etiqueta" => "5" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Vascular dominance in the forearm" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:5 [ 0 => "M. Haerle" 1 => "H.M. Häfner" 2 => "K. Dietz" 3 => "H.E. Schaller" 4 => "F. Brunelli" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1097/01.PRS.0000057529.76413.D7" "Revista" => array:6 [ "tituloSerie" => "Plast Reconstr Surg" "fecha" => "2003" "volumen" => "111" "paginaInicial" => "1891" "paginaFinal" => "1898" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/12711949" "web" => "Medline" ] ] ] ] ] ] ] ] 5 => array:3 [ "identificador" => "bib0100" "etiqueta" => "6" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Dynamic Doppler evaluation of the radial and ulnar arteries in patients with carpal tunnel syndrome" "autores" => array:1 [ 0 => array:2 [ "etal" => true "autores" => array:6 [ 0 => "H. Özcan" 1 => "M. Kara" 2 => "F. Özcan" 3 => "S. Bostanoğlu" 4 => "M. Karademir" 5 => "G. Erkin" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:5 [ "tituloSerie" => "Am J Roentgenol" "fecha" => "2011" "volumen" => "197" "paginaInicial" => "817" "paginaFinal" => "820" ] ] ] ] ] ] 6 => array:3 [ "identificador" => "bib0105" "etiqueta" => "7" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "An objective Allen test using color Doppler echo" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:4 [ 0 => "A. Kajikawa" 1 => "K. Ueda" 2 => "Y. Mochizuki" 3 => "Y. Katsuragi" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1097/PRS.0b013e3181c725bc" "Revista" => array:6 [ "tituloSerie" => "Plast Reconstr Surg" "fecha" => "2010" "volumen" => "125" "paginaInicial" => "82e" "paginaFinal" => "85e" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/20124821" "web" => "Medline" ] ] ] ] ] ] ] ] 7 => array:3 [ "identificador" => "bib0110" "etiqueta" => "8" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Correlation of modified Allen test with Doppler ultrasonography" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:6 [ 0 => "K. Cagli" 1 => "A. Uzun" 2 => "M. Emir" 3 => "V. Bakuy" 4 => "M. Ulas" 5 => "E. Sener" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1177/021849230601400205" "Revista" => array:6 [ "tituloSerie" => "Asian Cardiovasc Thorac Ann" "fecha" => "2006" "volumen" => "14" "paginaInicial" => "105" "paginaFinal" => "108" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/16551815" "web" => "Medline" ] ] ] ] ] ] ] ] 8 => array:3 [ "identificador" => "bib0115" "etiqueta" => "9" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Size of radial and ulnar artery in local population" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:6 [ 0 => "T. Ashraf" 1 => "Z. Panhwar" 2 => "S. Habib" 3 => "M.A. Memon" 4 => "F. Shamsi" 5 => "J. Arif" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "J Pak Med Assoc" "fecha" => "2010" "volumen" => "60" "paginaInicial" => "817" "paginaFinal" => "819" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/21381609" "web" => "Medline" ] ] ] ] ] ] ] ] 9 => array:3 [ "identificador" => "bib0120" "etiqueta" => "10" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Forearm arterial anatomy and flow characteristics: a prospective observational study" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "S.B. Pancholy" 1 => "L.A. Heck" 2 => "T. Patel" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "J Invasive Cardiol" "fecha" => "2015" "volumen" => "27" "paginaInicial" => "218" "paginaFinal" => "221" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/25840406" "web" => "Medline" ] ] ] ] ] ] ] ] 10 => array:3 [ "identificador" => "bib0125" "etiqueta" => "11" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Color flow Doppler: imaging the upper extremity" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:4 [ 0 => "S. Trager" 1 => "M. Pignataro" 2 => "J. Anderson" 3 => "J.M. Kleinert" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/0363-5023(93)90304-L" "Revista" => array:6 [ "tituloSerie" => "J Hand Surg Am" "fecha" => "1993" "volumen" => "18" "paginaInicial" => "621" "paginaFinal" => "625" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/8349968" "web" => "Medline" ] ] ] ] ] ] ] ] 11 => array:3 [ "identificador" => "bib0130" "etiqueta" => "12" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Study of ulnar and radial arteries at wrist level in smokers" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:2 [ 0 => "S. Ali" 1 => "S. Srivastava" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1080/02844310802299742" "Revista" => array:6 [ "tituloSerie" => "Scand J Plast Reconstr Surg Hand Surg" "fecha" => "2008" "volumen" => "42" "paginaInicial" => "320" "paginaFinal" => "324" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/18991177" "web" => "Medline" ] ] ] ] ] ] ] ] 12 => array:3 [ "identificador" => "bib0135" "etiqueta" => "13" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "The acute effect of cigarette smoking on the microcirculation of a replanted digit" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:4 [ 0 => "L.N. Van Adrichem" 1 => "S.E. Hovius" 2 => "R. van Strik" 3 => "J.C. van der Meulen" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/0363-5023(92)90397-8" "Revista" => array:6 [ "tituloSerie" => "J Hand Surg Am" "fecha" => "1992" "volumen" => "17" "paginaInicial" => "230" "paginaFinal" => "234" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/1564268" "web" => "Medline" ] ] ] ] ] ] ] ] 13 => array:3 [ "identificador" => "bib0140" "etiqueta" => "14" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Cigarette smoking is associated with an acute impairment of microvascular function in humans" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:5 [ 0 => "R.G. Ijzerman" 1 => "E.H. Serne" 2 => "M.M. van Weissenbruch" 3 => "R.T. de Jongh" 4 => "C.D. Stehouwer" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1042/CS20020318" "Revista" => array:6 [ "tituloSerie" => "Clin Sci" "fecha" => "2003" "volumen" => "104" "paginaInicial" => "247" "paginaFinal" => "252" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/12605581" "web" => "Medline" ] ] ] ] ] ] ] ] ] ] ] ] ] "idiomaDefecto" => "en" "url" => "/19888856/0000006400000003/v1_202005231742/S1988885620300286/v1_202005231742/en/main.assets" "Apartado" => array:4 [ "identificador" => "7577" "tipo" => "SECCION" "en" => array:2 [ "titulo" => "Original articles" "idiomaDefecto" => true ] "idiomaDefecto" => "en" ] "PDF" => "https://static.elsevier.es/multimedia/19888856/0000006400000003/v1_202005231742/S1988885620300286/v1_202005231742/en/main.pdf?idApp=UINPBA00004N&text.app=https://www.elsevier.es/" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S1988885620300286?idApp=UINPBA00004N" ]
Year/Month | Html | Total | |
---|---|---|---|
2024 November | 4 | 1 | 5 |
2024 October | 22 | 11 | 33 |
2024 September | 33 | 8 | 41 |
2024 August | 29 | 6 | 35 |
2024 July | 53 | 7 | 60 |
2024 June | 11 | 4 | 15 |
2024 May | 28 | 3 | 31 |
2024 April | 13 | 10 | 23 |
2024 March | 24 | 16 | 40 |
2024 February | 20 | 10 | 30 |
2024 January | 38 | 3 | 41 |
2023 December | 45 | 8 | 53 |
2023 November | 39 | 6 | 45 |
2023 October | 63 | 4 | 67 |
2023 September | 35 | 2 | 37 |
2023 August | 44 | 7 | 51 |
2023 July | 86 | 4 | 90 |
2023 June | 56 | 6 | 62 |
2023 May | 88 | 1 | 89 |
2023 April | 114 | 6 | 120 |
2023 March | 122 | 8 | 130 |
2023 February | 72 | 3 | 75 |
2023 January | 91 | 9 | 100 |
2022 December | 68 | 8 | 76 |
2022 November | 98 | 6 | 104 |
2022 October | 50 | 11 | 61 |
2022 September | 50 | 20 | 70 |
2022 August | 59 | 10 | 69 |
2022 July | 55 | 15 | 70 |
2022 June | 50 | 12 | 62 |
2022 May | 62 | 13 | 75 |
2022 April | 50 | 15 | 65 |
2022 March | 60 | 18 | 78 |
2022 February | 29 | 7 | 36 |
2022 January | 38 | 5 | 43 |
2021 December | 19 | 9 | 28 |
2021 November | 42 | 12 | 54 |
2021 October | 36 | 12 | 48 |
2021 September | 28 | 9 | 37 |
2021 August | 21 | 4 | 25 |
2021 July | 27 | 9 | 36 |
2021 June | 10 | 2 | 12 |
2021 May | 25 | 7 | 32 |
2021 April | 69 | 2 | 71 |
2021 March | 15 | 6 | 21 |
2021 February | 10 | 8 | 18 |
2021 January | 10 | 8 | 18 |
2020 December | 2 | 0 | 2 |
2020 May | 1 | 2 | 3 |