metricas
covid
Buscar en
Actas Urológicas Españolas
Toda la web
Inicio Actas Urológicas Españolas Procedimiento Cabestrillo Autólogo versus Sintético: Tasa de éxito y frecuenc...
Información de la revista
Vol. 33. Núm. 2.
Páginas 154-158 (enero 2009)
Compartir
Compartir
Descargar PDF
English PDF
Más opciones de artículo
Vol. 33. Núm. 2.
Páginas 154-158 (enero 2009)
Procedimiento Cabestrillo Autólogo versus Sintético: Tasa de éxito y frecuencia de obstrucción del tracto urinario inferior
Autologous versus Synthetic sling procedure: Success rate and bladder outlet obstruction rates
Visitas
2461
A. Ricardo1
Autor para correspondencia
ppalma@uol.com.br

Correspondencia autor: Dr. Paulo C. Rodrigues Palma Departamento de Urología Cidade Universitária “Zeferino Vaz” Rua: Tessália Vieira de Camargo, 126 CEP: 13083-887 Campinas - SP - Brasil. Tel: +55 19 3521 7486.
, Natalin, Cassio Riccetto, Renato Nardi Pedro, Alessandro Prudente, Guillermo Salvador Navarrete, C. Paulo, Rodrigues Palma
Departamento de Urología. Universidad Estatal de Campinas - UNICAMP - Brasil.
Este artículo ha recibido
Información del artículo
Resumen
Introducción

Disfunción en el vaciamiento y retención urinaria son complicaciones frecuentes del cabestrillo. Recientemente se han incluido en el arsenal para el soporte sub-uretral, suministros sintéticos tales como la malla de polipropilenol.

Métodos

Se llevó a cabo un Estudio prospectivo no aleatorizado. El procedimiento cabestrillo se realizó en 436 pacientes consecutivos con IUE (Incontinencia Urinaria de Esfuerzo). Las pacientes fueron divididas en grupos según el tipo de malla, en autólogos 210 y 226 sintéticos. Las pacientes fueron evaluadas en cuanto a condición de vaciamiento, continencia y satisfacción. Los resultados quirúrgicos fueron evaluados en función de la clasificación de Blaivas. Se consideró significativo p<0,05.

Resultados

La media de edad fue 48,4 años. El tiempo medio operatorio para los Cabestrillo autólogos fue de 107,6 minutos frente a 20,6 min para el sintético. El promedio de hospitalización fue de 36 horas para autólogos frente a 24 horas para los sintéticos y la media de seguimiento fue de 25 meses. Se encontró 87,1% y 92,9% de las pacientes continentes en los grupos autólogos y sintéticos, respectivamente. Fallo en el procedimiento se presentó en un 7% en el grupo autólogo y 4,8% en el sintético (p=0,1961). La tasa global de obstrucción del tracto urinario inferior fue de 4,5% (20/436), cuando se analizó por grupos, encontramos en el grupo autólogo una tasa de 8,5% (18/210), en comparación con el 0,9% en el grupo sintético (2/226) (p=0,000126).

Conclusiones

Cabestrillos autólogos y sintéticos presentan las tasas de éxito comparables, sin embargo la obstrucción del tracto urinario inferior fue más común entre las pacientes tratadas con fascias autólogas.

Palabras claves:
Cabestrillo
Sling
autólogo Sintético
Malla
Incontinencia urinaria
Abstract
Objectives

Voiding dysfunction and urinary retention were frequent complications of sling. More recently synthetic supplies such as polypropylene mesh have been included in the armamentarium for sub urethral support.

Methods

A prospective non randomized study was conducted. Sling procedure was performed in 436 consecutive patients with SUI. Patients were divided in groups according to mesh type, being 210 on autologous and 226 on synthetic. Patients were surveyed on voiding condition, continence and satisfaction. Surgical results were assessed according to Blaivas classification. Results were considered significant p<0.05.

Results

Mean patient age was 48,4years. Mean operative time for autologous sling was of 107,6 min versus 20,6min for synthetic. Mean hospitalization was 36h on autologous versus 24h on synthetic and mean follow up was 25 months. We found 87,1% and 92,9% of patients continent in autologous and synthetic group, respectively. Failure was presented by 7% in autologous and 4,8 % in synthetic group (p=0.1961). The global rate of BOO was of 4,5 % (20/436), when analysed by groups we found on autologous a rate of 8.5% (18/210), compared to 0.9% on synthetics (2/226) (p=0.000126).

Conclusions

Autologous and synthetic slings presented comparable success rates, however BOO was more common among patients treated by autologous slings.

Keywords:
Sling
Autologous
Synthetic
Mesh
Urinary incontinence

Artículo

Opciones para acceder a los textos completos de la publicación Actas Urológicas Españolas
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Actas Urológicas Españolas

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos