covid
Buscar en
Angiología
Toda la web
Inicio Angiología Espacio aortoentérico en pacientes sin patología aortoiliaca
Información de la revista
Vol. 59. Núm. 5.
Páginas 381-386 (enero 2007)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Vol. 59. Núm. 5.
Páginas 381-386 (enero 2007)
Acceso a texto completo
Espacio aortoentérico en pacientes sin patología aortoiliaca
Aortoenteric space in patients with no aortoiliac pathology
Visitas
2281
R. Gómez-Medialdeaa,
Autor para correspondencia
rgomezm@medynet.com

Correspondencia: Servicio de Angiología y Cirugía Vascular. Hospital Universitario Virgen de la Victoria. Campus Universitario de Teatinos. E-29010 Málaga.
, A. Rodríguez-Morataa, J. Azcona-Fabóna, E. Ros-Díec, J. Villalobos-Martínb, R. Aguilar-Cuevasb
a Servicio de Angiología y Cirugía Vascular
b Servicio de Radiología. Hospital Universitario Virgen de la Victoria. Málaga
c Servicio de Angiologia y Cirugía Vascular. Hospital Universitario San Cecilio. Granada, España
Este artículo ha recibido
Información del artículo
Resumen
Introducción

La separación entre la aorta abdominal y el intestino adyacente es una relación anatómica utilizada en el seguimiento de intervenciones por cirugía protésica aortoiliaca y en estudios diagnósticos por sospecha de fístulas aortoentéricas; esta relación se valora frecuentemente por tomografía axial computarizada (TAC), pero no encontramos en la bibliografía medidas de referencia del espacio aortoentérico (EAE). Por ello, para establecer los parámetros de normalidad de este espacio, que sirvieran de comparación con pacientes a los que realizamos epiploplastia preventiva, que fue motivo de otro trabajo, evaluamos los estudios con TAC contrastados en un grupo de pacientes no intervenidos.

Objetivo

Evaluar las medidas del EAE en enfermos no intervenidos.

Pacientes y métodos

Estudio de 55 TAC en 55 pacientes consecutivos, con una edad media de 59 años (sexo: masculino 48 y femenino 7). Se recogieron: la edad, el sexo, la talla, el peso y la medida del EAE en tres niveles.

Resultados

Las medidas del EAE dieron valores medios en el nivel A de 1,13, en B de 1,24 y en C de 1,33mm. Al comparar los valores de los tres niveles, hubo diferencia significativa sólo entre A y C (p < 0,005). También, comparamos las medidas en los niveles A, B y C entre las clases de edad, talla y peso, y se encontró diferencia significativa entre ellas.

Conclusión

El EAE estudiado por TAC contrastada en enfermos no intervenidos aumenta craneocaudalmente en la aorta infrarrenal y se relaciona con la edad y el peso.

Palabras clave:
Epiploplastia preventiva
Espacio aortoentérico
Tomografia axial computarizada
Summary
Introduction

The separation between the abdominal aorta and the adjacent intestine is an anatomical relation that is utilised in following up aortoiliac graft surgery and in diagnostic studies carried out due to suspected aortoenteric fistulae; this relation is frequently evaluated by computerised axial tomography (CAT) scans, but no reference measures for the aortoenteric space (AES) were found in the literature. Thus, to establish the parameters of normality for this space, which could be used in comparisons with patients who underwent preventive epiploplasty (which was the subject of a previous study), we evaluated the CAT scan studies that were contrasted in a group of patients who were not submitted to surgery.

Aims

To evaluate the measurements of the AES in patients who had not undergone surgery.

Patients and methods

We studied 55 CAT scans in 55 consecutive patients, with a mean age of 59 years (sex: 48 males and 7 females). Data collected: age, sex, height, weight and the size of the AES at three levels.

Results

The mean values of the AES measurements at level A were 1.13, at level B they were 1.24 and at level C they were 1.33mm. On comparing the values of the three levels, the only significant difference was found between A and C (p < 0.005). Furthermore, we compared the measurements at levels A, B and C between the age, height and weight classes, and significant differences were found between them.

Conclusions

The AES studied by CAT contrasted in patients who had not undergone surgery increases craniocaudally in the infrarenal aorta and is related to the age and weight.

Key words:
Aortoenteric space
Computerised axial tomography
Preventive epiploplasty
El Texto completo está disponible en PDF
Bibliografía
[1.]
Bacourt F..
Fistules aorto-digestives prothétiques.
Les urgences en chirurgie vasculaire, pp. 96-105
[2.]
Bernhard V.M..
Aortoenteric fistulas.
Vascular surgery, pp. 528-535
[3.]
Elliot J.P., Smith R.F., Szilagyi D.E..
Aorto-enteric and paraprosthetic enteric fistulas.
Arch Surg., 108 (1974), pp. 479-490
[4.]
Lázaro T..
Fistules aorto-enterics secondaires.
Lésions occlusives aorto-iliaques chroniques, pp. 287-292
[5.]
O';Brien S.P..
Aortoenteric fistulae.
Vascular surgery, pp. 763-775
[6.]
Ernst C.B..
Aortic grafts enteric fistula.
Current therapy in vascular surgery, pp. 440-446
[7.]
Harris J.P., Sheila G.R., Stephen H.S., Storey D.W., May J..
Lessons learnt in the management of aortoenteric fistulae.
J Cardiovasc Surg., 28 (1987), pp. 449-452
[8.]
Connoly J.E., Kwaan J.H., McCart P.M..
Aortoenteric fistula.
Ann Surg., 4 (1981), pp. 402-410
[9.]
Miller D.R..
Prevention of aortoduodenal fistula by duodenal reflection.
Am J Surg., 138 (1979), pp. 332-333
[10.]
O'Mara C.S., Williams G.M., Ernst C.B..
Secondary aortoenteric fistula, a 20 years experience.
Am J Surg., 142 (1981), pp. 203
[11.]
Levy M.J., Todd D.B., Lillehei C.W., Vargo R.L..
Aortico-intestinal fistulas following surgery of the aorta.
Surg Gynecol Obstet, 120 (1965), pp. 992-996
[12.]
Gómez R..
Prótesis bifurcadas en el sector aorto-ilio-femoral, la epiploplastia como profilaxis de la fístula aortoentérica secundaria, Facultad de Medicina, (1993),
[13.]
Moulton S., Adams M., Johansen K..
Aortoenteric fistula, a 7 years urban experience.
Am J Surg., 151 (1986), pp. 607-611
[14.]
Luca D.M., Feldhaus R.J., Shultz R.D..
Surgical treatment of infected aortofemoral grafts: a fifteen-year experience.
Vasc Surg., 21 (1987), pp. 229-236
[15.]
Kukora J.S., Rushton F.W., Cranston P.E..
New computed tomographic signs of aortoenteric fistula.
Arch Surg., 119 (1984), pp. 1073
[16.]
Taylor L.M., Van Kolken J.V., Baur G.M., Porter J.M..
Precise diagnostic of aortic anastomotic aneurysm by computed tomographic scan.
Arch Surg., 116 (1981), pp. 1209-1211
[17.]
Mark A.S., Moss A.A., McCarthy S..
CT of aortoenteric fistulas.
Invest Radiol., 20 (1985), pp. 272
Copyright © 2007. SEACV
Descargar PDF
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos