array:24 [ "pii" => "S2173579417300403" "issn" => "21735794" "doi" => "10.1016/j.oftale.2016.11.012" "estado" => "S300" "fechaPublicacion" => "2017-09-01" "aid" => "1141" "copyright" => "Sociedad Española de Oftalmología" "copyrightAnyo" => "2017" "documento" => "simple-article" "crossmark" => 1 "subdocumento" => "cor" "cita" => "Arch Soc Esp Oftalmol. 2017;92:e53-4" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:2 [ "total" => 2 "formatos" => array:2 [ "HTML" => 1 "PDF" => 1 ] ] "Traduccion" => array:1 [ "es" => array:19 [ "pii" => "S0365669117300163" "issn" => "03656691" "doi" => "10.1016/j.oftal.2016.11.020" "estado" => "S300" "fechaPublicacion" => "2017-09-01" "aid" => "1141" "copyright" => "Sociedad Española de Oftalmología" "documento" => "simple-article" "crossmark" => 1 "subdocumento" => "cor" "cita" => "Arch Soc Esp Oftalmol. 2017;92:e53-4" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:2 [ "total" => 24 "formatos" => array:2 [ "HTML" => 20 "PDF" => 4 ] ] "es" => array:10 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Carta al director</span>" "titulo" => "Pérdida endotelial con la lente fáquica de apoyo angular AcrySof<span class="elsevierStyleSup">®</span> Cachet<span class="elsevierStyleSup">®</span>" "tienePdf" => "es" "tieneTextoCompleto" => "es" "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "e53" "paginaFinal" => "e54" ] ] "titulosAlternativos" => array:1 [ "en" => array:1 [ "titulo" => "Endothelial loss with AcrySof<span class="elsevierStyleSup">®</span> Cachet<span class="elsevierStyleSup">®</span> angle-supported phakic lens" ] ] "contieneTextoCompleto" => array:1 [ "es" => true ] "contienePdf" => array:1 [ "es" => true ] "autores" => array:1 [ 0 => array:2 [ "autoresLista" => "V. Galvis, A. Tello, N.I. Carreño, R.D. Berrospi, C.A. Niño, M.O. Cuadros" "autores" => array:6 [ 0 => array:2 [ "nombre" => "V." "apellidos" => "Galvis" ] 1 => array:2 [ "nombre" => "A." "apellidos" => "Tello" ] 2 => array:2 [ "nombre" => "N.I." "apellidos" => "Carreño" ] 3 => array:2 [ "nombre" => "R.D." "apellidos" => "Berrospi" ] 4 => array:2 [ "nombre" => "C.A." "apellidos" => "Niño" ] 5 => array:2 [ "nombre" => "M.O." "apellidos" => "Cuadros" ] ] ] ] ] "idiomaDefecto" => "es" "Traduccion" => array:1 [ "en" => array:9 [ "pii" => "S2173579417300403" "doi" => "10.1016/j.oftale.2016.11.012" "estado" => "S300" "subdocumento" => "" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:1 [ "total" => 0 ] "idiomaDefecto" => "en" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2173579417300403?idApp=UINPBA00004N" ] ] "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0365669117300163?idApp=UINPBA00004N" "url" => "/03656691/0000009200000009/v1_201708280004/S0365669117300163/v1_201708280004/es/main.assets" ] ] "itemSiguiente" => array:19 [ "pii" => "S2173579417301160" "issn" => "21735794" "doi" => "10.1016/j.oftale.2017.02.017" "estado" => "S300" "fechaPublicacion" => "2017-09-01" "aid" => "1183" "copyright" => "Sociedad Española de Oftalmología" "documento" => "simple-article" "crossmark" => 1 "subdocumento" => "cor" "cita" => "Arch Soc Esp Oftalmol. 2017;92:e55" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:2 [ "total" => 4 "HTML" => 4 ] "en" => array:10 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Letter to the Editor</span>" "titulo" => "Author's reply" "tienePdf" => "en" "tieneTextoCompleto" => "en" "paginas" => array:1 [ 0 => array:1 [ "paginaInicial" => "e55" ] ] "titulosAlternativos" => array:1 [ "es" => array:1 [ "titulo" => "Respuesta a los autores" ] ] "contieneTextoCompleto" => array:1 [ "en" => true ] "contienePdf" => array:1 [ "en" => true ] "autores" => array:1 [ 0 => array:2 [ "autoresLista" => "J.L. Alio" "autores" => array:1 [ 0 => array:2 [ "nombre" => "J.L." "apellidos" => "Alio" ] ] ] ] ] "idiomaDefecto" => "en" "Traduccion" => array:1 [ "es" => array:9 [ "pii" => "S0365669117301235" "doi" => "10.1016/j.oftal.2017.02.014" "estado" => "S300" "subdocumento" => "" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:1 [ "total" => 0 ] "idiomaDefecto" => "es" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0365669117301235?idApp=UINPBA00004N" ] ] "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2173579417301160?idApp=UINPBA00004N" "url" => "/21735794/0000009200000009/v2_201708291316/S2173579417301160/v2_201708291316/en/main.assets" ] "itemAnterior" => array:19 [ "pii" => "S2173579417301299" "issn" => "21735794" "doi" => "10.1016/j.oftale.2017.06.002" "estado" => "S300" "fechaPublicacion" => "2017-09-01" "aid" => "1155" "copyright" => "Sociedad Española de Oftalmología" "documento" => "article" "crossmark" => 1 "subdocumento" => "fla" "cita" => "Arch Soc Esp Oftalmol. 2017;92:451-4" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:1 [ "total" => 0 ] "en" => array:13 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Short communication</span>" "titulo" => "Sterile infiltrates after cross-linking" "tienePdf" => "en" "tieneTextoCompleto" => "en" "tieneResumen" => array:2 [ 0 => "en" 1 => "es" ] "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "451" "paginaFinal" => "454" ] ] "titulosAlternativos" => array:1 [ "es" => array:1 [ "titulo" => "Infiltrados estériles tras <span class="elsevierStyleItalic">cross-linking</span>" ] ] "contieneResumen" => array:2 [ "en" => true "es" => true ] "contieneTextoCompleto" => array:1 [ "en" => true ] "contienePdf" => array:1 [ "en" => true ] "resumenGrafico" => array:2 [ "original" => 0 "multimedia" => array:7 [ "identificador" => "fig0010" "etiqueta" => "Fig. 2" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr2.jpeg" "Alto" => 676 "Ancho" => 1575 "Tamanyo" => 139556 ] ] "descripcion" => array:1 [ "en" => "<p id="spar0030" class="elsevierStyleSimplePara elsevierViewall">Result 3 days after the cross-linking, showing whitish infiltrates occupying superficial layers as well as the absence of conjunctival hyperemia: (A) anterior pole photograph and (B) Cleft photograph.</p>" ] ] ] "autores" => array:1 [ 0 => array:2 [ "autoresLista" => "G. García de Oteyza, J. Álvarez de Toledo" "autores" => array:2 [ 0 => array:2 [ "nombre" => "G." "apellidos" => "García de Oteyza" ] 1 => array:2 [ "nombre" => "J." "apellidos" => "Álvarez de Toledo" ] ] ] ] ] "idiomaDefecto" => "en" "Traduccion" => array:1 [ "es" => array:9 [ "pii" => "S0365669117300308" "doi" => "10.1016/j.oftal.2017.01.006" "estado" => "S300" "subdocumento" => "" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:1 [ "total" => 0 ] "idiomaDefecto" => "es" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0365669117300308?idApp=UINPBA00004N" ] ] "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2173579417301299?idApp=UINPBA00004N" "url" => "/21735794/0000009200000009/v2_201708291316/S2173579417301299/v2_201708291316/en/main.assets" ] "en" => array:13 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Letter to the Editor</span>" "titulo" => "Endothelial loss with AcrySof<span class="elsevierStyleSup">®</span> Cachet<span class="elsevierStyleSup">®</span> angle-supported phakic lens" "tieneTextoCompleto" => true "saludo" => "Dear Editor:" "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "e53" "paginaFinal" => "e54" ] ] "autores" => array:1 [ 0 => array:4 [ "autoresLista" => "V. Galvis, A. Tello, N.I. Carreño, R.D. Berrospi, C.A. Niño, M.O. Cuadros" "autores" => array:6 [ 0 => array:3 [ "nombre" => "V." "apellidos" => "Galvis" "referencia" => array:3 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">a</span>" "identificador" => "aff0005" ] 1 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">b</span>" "identificador" => "aff0010" ] 2 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">c</span>" "identificador" => "aff0015" ] ] ] 1 => array:4 [ "nombre" => "A." "apellidos" => "Tello" "email" => array:1 [ 0 => "alejandrotello@gmail.com" ] "referencia" => array:4 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">a</span>" "identificador" => "aff0005" ] 1 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">b</span>" "identificador" => "aff0010" ] 2 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">c</span>" "identificador" => "aff0015" ] 3 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">*</span>" "identificador" => "cor0005" ] ] ] 2 => array:3 [ "nombre" => "N.I." "apellidos" => "Carreño" "referencia" => array:3 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">a</span>" "identificador" => "aff0005" ] 1 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">b</span>" "identificador" => "aff0010" ] 2 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">c</span>" "identificador" => "aff0015" ] ] ] 3 => array:3 [ "nombre" => "R.D." "apellidos" => "Berrospi" "referencia" => array:2 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">a</span>" "identificador" => "aff0005" ] 1 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">b</span>" "identificador" => "aff0010" ] ] ] 4 => array:3 [ "nombre" => "C.A." "apellidos" => "Niño" "referencia" => array:2 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">a</span>" "identificador" => "aff0005" ] 1 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">b</span>" "identificador" => "aff0010" ] ] ] 5 => array:3 [ "nombre" => "M.O." "apellidos" => "Cuadros" "referencia" => array:2 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">a</span>" "identificador" => "aff0005" ] 1 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">b</span>" "identificador" => "aff0010" ] ] ] ] "afiliaciones" => array:3 [ 0 => array:3 [ "entidad" => "Centro Oftalmológico Virgilio Galvis, Floridablanca, Colombia" "etiqueta" => "a" "identificador" => "aff0005" ] 1 => array:3 [ "entidad" => "Fundación Oftalmológica de Santander FOSCAL, Floridablanca, Colombia" "etiqueta" => "b" "identificador" => "aff0010" ] 2 => array:3 [ "entidad" => "Universidad Autónoma de Bucaramanga, Facultad de Salud, Bucaramanga, Colombia" "etiqueta" => "c" "identificador" => "aff0015" ] ] "correspondencia" => array:1 [ 0 => array:3 [ "identificador" => "cor0005" "etiqueta" => "⁎" "correspondencia" => "<span class="elsevierStyleItalic">Corresponding author</span>." ] ] ] ] "titulosAlternativos" => array:1 [ "es" => array:1 [ "titulo" => "Pérdida endotelial con la lente fáquica de apoyo angular AcrySof<span class="elsevierStyleSup">®</span> Cachet<span class="elsevierStyleSup">®</span>" ] ] "textoCompleto" => "<span class="elsevierStyleSections"><p id="par0005" class="elsevierStylePara elsevierViewall">We have read with great interest the article about the results with the phakic AcrySof<span class="elsevierStyleSup">®</span> Cachet<span class="elsevierStyleSup">®</span> lens by Alió et al.<a class="elsevierStyleCrossRef" href="#bib0020"><span class="elsevierStyleSup">1</span></a> Our first comment is that, even though the fact is mentioned in the figures and tables of said article, for the sake of clarity it would have been good to point out in the text that only 25 eyes had a follow-up of 5 years.</p><p id="par0010" class="elsevierStylePara elsevierViewall">In the late 80s Baikoff revived the concept of angle support phakic intraocular lenses with the Baikoff (ZB, ZB5M and NuVita) models. In addition, several manufacturers released in the first decade of the present century similar types of lenses (Phakic 6 H2, Vivarte, GBR, NewLife, I-Care, ZSAL-4 and AcrySof<span class="elsevierStyleSup">®</span> Cachet<span class="elsevierStyleSup">®</span>). However, at present and without exception all angle support phakic lenses have been withdrawn from the market due to mid- and long-term complications mainly related to endothelial loss (including AcrySof<span class="elsevierStyleSup">®</span> Cachet<span class="elsevierStyleSup">®</span> by Alcon<span class="elsevierStyleSup">®</span>, withdrawn September 2014). In a letter addressed to ophthalmologists, Alcon<span class="elsevierStyleSup">®</span> explained that the decision was taken because 2.7% of lenses in a group of 1323 cases had to be explanted due to endothelial loss.<a class="elsevierStyleCrossRef" href="#bib0025"><span class="elsevierStyleSup">2</span></a></p><p id="par0015" class="elsevierStylePara elsevierViewall">There is very few literature on explants of said lens. Pechméja et al. reported the case of a patient who required explantation due to severe endothelial loss. Endothelial count was found to be 680<span class="elsevierStyleHsp" style=""></span>cells/mm<span class="elsevierStyleSup">2</span> prior to explant.<a class="elsevierStyleCrossRef" href="#bib0030"><span class="elsevierStyleSup">3</span></a> Alió et al. also mentioned that the AcrySof<span class="elsevierStyleSup">®</span> Cachet<span class="elsevierStyleSup">®</span> lens had to be withdrawn from one eye. It would be important to determine endothelial cells density of that case before and after the explant. In addition, said authors mentioned that one eye exhibited cell density below 1500<span class="elsevierStyleHsp" style=""></span>cells/mm<span class="elsevierStyleSup">2</span> (this case explains the extremely low inferior range of cell density after 5 years of 808<span class="elsevierStyleHsp" style=""></span>cells/mm<span class="elsevierStyleSup">2</span>). Was that the above-mentioned explanation case or a different eye? If it was another patient, what approach was taken? It would be interesting to know how many of the 25 eyes that were followed up for 5 years exhibited densities between 1500 and 2000<span class="elsevierStyleHsp" style=""></span>cells/mm<span class="elsevierStyleSup">2</span>.</p><p id="par0020" class="elsevierStylePara elsevierViewall">In addition, even though the authors indicate that the biggest endothelial loss took place within the first 6 months after surgery, it is surprising that the inferior range of that range diminished significantly after 2 years follow-up, which suggests a late continuous loss, at least in one eye.</p><p id="par0025" class="elsevierStylePara elsevierViewall">The fact that multiple attempts to develop a safe angle support phakic lens have failed, together with the existence of severe corneal complications that jeopardize vision, quite clearly suggests that this type of approach should not be pursued in the future. On the other hand, it is very important to call the patients who received implants of said lenses for a corneal endothelial cell count in order to assess the need for an early explant before the appearance of irreversible corneal edema and the need for a corneal transplant.</p></span>" "pdfFichero" => "main.pdf" "tienePdf" => true "NotaPie" => array:1 [ 0 => array:2 [ "etiqueta" => "☆" "nota" => "<p class="elsevierStyleNotepara" id="npar0005">Please cite this article as: Galvis V, Tello A, Carreño NI, Berrospi RD, Niño CA, Cuadros MO. Pérdida endotelial con la lente fáquica de apoyo angular AcrySof<span class="elsevierStyleSup">®</span> Cachet<span class="elsevierStyleSup">®</span>. Arch Soc Esp Oftalmol. 2017;92:e53–e54.</p>" ] ] "bibliografia" => array:2 [ "titulo" => "References" "seccion" => array:1 [ 0 => array:2 [ "identificador" => "bibs0005" "bibliografiaReferencia" => array:3 [ 0 => array:3 [ "identificador" => "bib0020" "etiqueta" => "1" "referencia" => array:1 [ 0 => array:3 [ "comentario" => "[in English, Spanish]" "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "An angle-supported foldable phakic intraocular lens for correction of myopia: a five-year follow-up" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:5 [ 0 => "J.L. Alió" 1 => "A.B. Plaza-Puche" 2 => "F. Cavas" 3 => "P. Yébana Rubio" 4 => "E. Sala" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.oftal.2016.05.009" "Revista" => array:6 [ "tituloSerie" => "Arch Soc Esp Oftalmol" "fecha" => "2017" "volumen" => "92" "paginaInicial" => "4" "paginaFinal" => "11" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/27453580" "web" => "Medline" ] ] ] ] ] ] ] ] 1 => array:3 [ "identificador" => "bib0025" "etiqueta" => "2" "referencia" => array:1 [ 0 => array:1 [ "referenciaCompleta" => "Corrective Action Alcon AcrySof<span class="elsevierStyleSup">®</span> CACHET<span class="elsevierStyleSup">®</span> Phakic Lens Product Discontinuation. Available from: <a href="http://www.bfarm.de/SharedDocs/Kundeninfos/EN/11/2014/06204_14_Kundeninfo_en.pdf?__blob=publicationFile%26v=3">http://www.bfarm.de/SharedDocs/Kundeninfos/EN/11/2014/06204_14_Kundeninfo_en.pdf?__blob=publicationFile&v=3</a> [accessed 27.11.16]." ] ] ] 2 => array:3 [ "identificador" => "bib0030" "etiqueta" => "3" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Severe endothelial cell loss with anterior chamber phakic intraocular lenses" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:4 [ 0 => "J. Pechméja" 1 => "J. Guinguet" 2 => "J. Colin" 3 => "P.S. Binder" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.jcrs.2012.04.022" "Revista" => array:6 [ "tituloSerie" => "J Cataract Refract Surg" "fecha" => "2012" "volumen" => "38" "paginaInicial" => "1288" "paginaFinal" => "1292" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/22727299" "web" => "Medline" ] ] ] ] ] ] ] ] ] ] ] ] ] "idiomaDefecto" => "en" "url" => "/21735794/0000009200000009/v2_201708291316/S2173579417300403/v2_201708291316/en/main.assets" "Apartado" => array:4 [ "identificador" => "5813" "tipo" => "SECCION" "en" => array:2 [ "titulo" => "Letter to the Editor" "idiomaDefecto" => true ] "idiomaDefecto" => "en" ] "PDF" => "https://static.elsevier.es/multimedia/21735794/0000009200000009/v2_201708291316/S2173579417300403/v2_201708291316/en/main.pdf?idApp=UINPBA00004N&text.app=https://www.elsevier.es/" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2173579417300403?idApp=UINPBA00004N" ]
Journal Information
Vol. 92. Issue 9.
Pages e53-e54 (September 2017)
Share
Download PDF
More article options
Vol. 92. Issue 9.
Pages e53-e54 (September 2017)
Letter to the Editor
Endothelial loss with AcrySof® Cachet® angle-supported phakic lens
Pérdida endotelial con la lente fáquica de apoyo angular AcrySof® Cachet®
Visits
8
This item has received
Article information
These are the options to access the full texts of the publication Archivos de la Sociedad Española de Oftalmología (English Edition)
Subscriber
Subscribe
Purchase
Contact
Phone for subscriptions and reporting of errors
From Monday to Friday from 9 a.m. to 6 p.m. (GMT + 1) except for the months of July and August which will be from 9 a.m. to 3 p.m.
Calls from Spain
932 415 960
Calls from outside Spain
+34 932 415 960
E-mail