metricas
covid
Buscar en
Cirugía Española (English Edition)
Toda la web
Inicio Cirugía Española (English Edition) Glove Port Cholecystectomy
Información de la revista
Vol. 92. Núm. 5.
Páginas 363-364 (mayo 2014)
Vol. 92. Núm. 5.
Páginas 363-364 (mayo 2014)
Scientific letter
Acceso a texto completo
Glove Port Cholecystectomy
Colecistectomía por puerto único
Visitas
2920
Verónica Gumbau Puchola, José Mir Labradorb,
Autor para correspondencia
jomirla@gmail.com

Corresponding author.
a Hospital General Universitario, Valencia, Spain
b Unidad Hepatobiliopancreática, Hospital General Universitario, Valencia, Spain
Este artículo ha recibido
Información del artículo
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (2)
Texto completo

The objectives of single-port procedures for cholecystectomy are: to minimize postoperative pain, improve esthetic results and not increase costs while maintaining patient safety.

In this paper, we describe how a surgical glove together with a conventional wound protector can be used to create a device that is comparable to commercially available ones to facilitate the single-incision approach for gallbladder resection in a Hepatobiliopancreatic Surgery Unit.

The proposed access device is made from a standard retractor (ALEXIS®, small size) and a number 8 surgical glove.

An umbilical incision is made in the skin with a 2–3cm aponeurotic orifice to allow for the correct placement of the retractor. The area is checked for adherences to the abdominal wall that could impede proper placement, and the inner ring is then put into place. With the intraperitoneal device in position, the outer ring is then correctly secured and the device is turned to achieve correct retraction and placement in the abdominal wall. Prior to giving the last two turns of the outer ring, we introduce the glove to be included in these last 2 turns so that the device presents no air leaks and stays in place throughout the entire intervention (Fig. 1).

Fig. 1.

Skin retractor.

(0.06MB).

We cut 2–3cm off of the glove fingers in order to provide better fixation of the trocar to the glove, greater stability and good mobility. We use the same instruments as in conventional laparoscopy since the device does not restrict their size. We introduce an 11mm trocar in the ring finger of the glove, a 5mm trocar in the thumb and the 11mm optical trocar in the middle finger. The trocars are secured by tying the fingers of the other glove around them, which makes the device airtight (Fig. 2).

Fig. 2.

Trocar and surgical glove.

(0.07MB).

These ports likewise provide a good entry orifice for the instruments that must be interchanged during surgery (camera, endo-stapler, dissector, etc.), while maintaining the pneumoperitoneum. Curved devices can be used if necessary.

During the maneuvers for introducing the instruments in the cavity, it is necessary for the camera to retrocede in order to show the parietal orifice and allow for the instruments to enter correctly without causing injury.

Triangulation with this type of surgery gives exposure of an adequate surgical field in order to correctly identify the elements of Calot's triangle and to perform cholecystectomy.

Once the surgical specimen is detached, it is withdrawn with the traction clamp. After disassembling the glove from the retractor, it is extracted through the orifice of the ALEXIS®. An additional savings of the use of the skin retractor is that it is not necessary to use an extraction bag for the gallbladder.

Wall closure is done conventionally and absorbable intradermal suture is used to reconstruct the skin; the incision scar is hidden within the navel.

We have used this technique in 3 patients between January and February 2013, with no immediate complications.

The approach that we propose for glove-port laparoscopic cholecystectomy uses a device that provides patient benefits and is affordably accessible for all surgeons and not just for those who have commercial devices available to them. With its use, we have found many advantages, which are not just cost-related.1,2 The use of this device is easy. Up to 5 instruments can be worked with simultaneously, with no size restrictions, while most commercial devices only have 3 or 4 working ports.

The glove port is certainly also attractive with regard to technique, as it provides a wider axis of movement. The instruments can be interchanged, crossed and rotated as the situation requires. Furthermore, there is freedom of movement in the horizontal and vertical planes and friction is avoided between the trocars and abdominal wall. This could be an advantage with regard to parietal trauma and could result in less postoperative pain.3,4

The use of the glove port is an inexpensive, safe, easy-to-do technique that should be considered for numerous procedures,5,6 such as laparoscopic cholecystectomy. It provides access that is, at the very least, similar to commercial devices. Due to its ease of use and the fact that it is a low-cost, reproducible technique, we believe that it can be implemented as a routine procedure for cholecystectomy in selected patients.

To validate the utility of this device, we believe that it is necessary to develop a comparative study between conventional single-port devices and the glove port system in order to analyze their advantages and disadvantages, with special emphasis given to the costs involved in the two procedures.

References
[1]
N.A. Henriksen, H. Al-Tayar, J. Rosenberg, L.N. Jorgensen.
Cost assessment of instruments for single-incision laparoscopic cholecystectomy.
[2]
R. Hompes, I. Lindsey, O.M. Jones, R. Guy, C. Cunningham, N.J. Mortensen.
A Cahill step-wise integration of single-port laparoscopic surgery into routine colorectal surgical practice by use of a surgical glove port.
Tech Coloproctol, 15 (2011), pp. 165-171
[3]
L. Livraghi, M. Berselli, V. Bianchi, L. Latham, L. Farassino, E. Cocozza.
Glove technique in single-port access laparoscopic surgery: results of an initial experience.
Minim Invasive Surg, 2012 (2012), pp. 415-430
[4]
M. Tsujie, M. Ikenaga, A. Miyamoto, S. Nakamori, M. Yasui, H. Omiya, et al.
Effectiveness of a surgical glove port with homemade trocars made of syringes for single incision laparoscopic cholecystectomy.
Hepatogastroenterology, 59 (2012), pp. 2407-2409
[5]
S.H. Choi, H.K. Hwang, C.M. Kang, W.J. Lee.
Transumbilical single port laparoscopic adrenalectomy: a technical report on right and left adrenalectomy using the glove port.
Yonsei Med J, 53 (2012), pp. 442-445
[6]
E. Ismail, C. Akyo, S.I. Basceken, U. Tantoglu, I. Kayılıoglu, A. Cakmak.
Glove port single-incision laparoscopic splenectomy and the treatment of its complications.
Clinics (Sao Paulo), 67 (2012), pp. 1519-2111

Please cite this article as: Gumbau Puchol V, Mir Labrador J. Colecistectomía por puerto único. Cir Esp. 2014;92:363–364.

Copyright © 2013. AEC
Descargar PDF
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

Quizás le interese:
10.1016/j.cireng.2019.12.012
No mostrar más