metricas
covid
Buscar en
Neurología (English Edition)
Toda la web
Inicio Neurología (English Edition) False ischaemic penumbras in CT perfusion in patients with carotid artery stenos...
Información de la revista
Vol. 35. Núm. 1.
Páginas 24-31 (enero - febrero 2020)
Visitas
4216
Vol. 35. Núm. 1.
Páginas 24-31 (enero - febrero 2020)
Original article
Open Access
False ischaemic penumbras in CT perfusion in patients with carotid artery stenosis and changes following angioplasty and stenting
Falsas penumbras isquémicas en la TC de perfusión en pacientes con estenosis carotídea y cambios después de la angioplastia y stenting
Visitas
4216
A.J. Mosqueiraa,
Autor para correspondencia
drmosqueiramartinez@gmail.com

Corresponding author.
, J.M. Pumara, S. Ariasb, M. Rodríguez-Yáñezb, M. Blanco Ullaa, F. Vázquez Herreroa, J. Castillob
a Servicio de Neurorradiología, Hospital Universitario Santiago de Compostela, Santiago de Compostela, A Coruña, Spain
b Servicio de Neurología, Hospital Universitario Santiago de Compostela, Santiago de Compostela, A Coruña, Spain
Este artículo ha recibido

Under a Creative Commons license
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (2)
Tablas (3)
Table 1. Summary of baseline clinical and carotid artery stenosis characteristics of the patient sample.
Table 2. Comparison of CT perfusion parameters in the deep and surface middle cerebral artery territories before and after carotid angioplasty and stenting.
Table 3. Comparison of CT perfusion parameters in the deep and surface middle cerebral artery territories before and after carotid angioplasty and stenting, broken down by degree of stenosis.
Mostrar másMostrar menos
Abstract
Introduction

Carotid artery stenosis influences CT perfusion (CTP) studies, sometimes manifesting as a false ischaemic penumbra (FIP). This study aims to estimate the incidence of FIP in patients with carotid artery stenosis, establish their relationship with the degree of stenosis, and measure quantitative and qualitative changes in CTP after carotid angioplasty and stenting (CAS).

Methods

Between October 2013 and June 2015, we prospectively selected 26 patients with carotid stenosis who underwent CAS, with CTP being performed 2-10 days before and after CAS.

Results

Sixteen patients had unilateral stenosis (11 in the subgroup displaying <90% stenosis and 5 in the subgroup with ≥90% stenosis) and 10 patients had bilateral stenosis. The incidence of FIP in patients with carotid artery stenosis was 38.5%. Risk of FIP increased in direct relation to degree of stenosis, with a relative risk of 11 in the subgroup with ≥90% stenosis with respect to the subgroup displaying <90% stenosis (95% CI, 1.7-71.3; P=.0005). There were statistically significant changes in the parameters CBF, TTP, MTT, and Tmax CTP, which reverted after angioplasty. No significant changes were found in CBV.

Conclusions

Carotid artery stenosis involves changes in CTP parameters. Patients with ≥90% stenosis carry a high risk of FIP; CTP studies may therefore be misinterpreted in these cases. Changes in CTP parameters are reverted after CAS.

Keywords:
Ischaemic stroke
Neuroimaging
CT perfusion
False penumbra
Carotid angioplasty and stenting
Resumen
Introducción

La estenosis carotídea tiene una influencia en la TC de perfusión (TCP), que en ocasiones se manifiesta como una falsa penumbra isquémica (FPI). El objetivo de nuestro estudio es estimar la incidencia de FPI en pacientes con estenosis carotídea, establecer su relación con el grado de estenosis y medir los cambios cuantitativos y cualitativos de la TCP después de la angioplastia carotídea y stenting (ACS).

Métodos

Entre octubre del 2013 y junio del 2015 se seleccionó prospectivamente a 26 pacientes con estenosis carotídea que fueron sometidos a una ACS, realizándose un TCP 2-10 días antes y después de la ACS.

Resultados

Dieciséis pacientes tenían una estenosis unilateral (11 en el subgrupo de < 90% de estenosis y 5 en el de ≥ 90%) y 10 pacientes una estenosis bilateral. La incidencia de FPI en pacientes con estenosis carotídea es del 38,5%. El riesgo de FPI aumenta en relación directa con el grado de estenosis, con un riesgo relativo de 11 en el grupo de ≥ 90% respecto al grupo de < 90% (IC del 95%: 1,7-71,3; p=0,0005). Existen cambios estadísticamente significativos en los parámetros CBF, TTP, MTT y Tmáx de la TCP que revierten tras la ACS. No hay cambios significativos en CBV.

Conclusiones

La estenosis carotídea implica cambios en los parámetros de la TCP, condicionando un alto riesgo de FPI en estenosis ≥ 90% y, por tanto, una posible interpretación equivocada de estos estudios. Estos cambios se revierten tras la ACS.

Palabras clave:
Ictus isquémico
Neuroimagen
TC perfusión
Falsas penumbra
Angioplastia carotídea y stenting
Texto completo
Introduction

Computed tomography (CT) plays a major role in diagnosis and therapeutic decision-making for acute stroke. Various clinical and imaging tools have been used to identify the ischaemic penumbra.1,2 One of these is CT perfusion, a widely available, easy-to-use tool providing fast measurement of perfusion, an essential step in the assessment of acute stroke.3–5

Understanding the limitations of CT perfusion is important given its widespread use. One of the limitations of CT perfusion is the inability to clearly differentiate between a true ischaemic penumbra (brain tissue at risk of progressing to infarction if vascular occlusion is not resolved) and benign oligaemia (slightly hypoperfused brain tissue with no imminent risk of infarction). Haemodynamically significant carotid artery stenosis may lead to alterations in CT perfusion values similar to those caused by ischaemic penumbra; this is known as false ischaemic penumbra (FIP).6

Although perfusion changes secondary to carotid artery stenosis are well known and are usually taken into consideration when interpreting CT perfusion images in clinical practice, no prospective studies have quantified the incidence of these changes or their association with the degree of stenosis, or analysed this effect in contexts other than acute stroke.7–9 We aimed to estimate the incidence of FIP in CT perfusion images from patients with carotid artery disease, establish the association with the degree of stenosis, and measure quantitative and qualitative changes in CT perfusion after carotid angioplasty and stenting (CAS).

Patients and methods

This study complies with the ethical principles of the Declaration of Helsinki. Confidentiality of patient data was guaranteed in accordance with Spanish legislation on data protection (Organic Law 15/1999). All patients signed informed consent forms prior to inclusion in the study.

Patient selection

From October 2013 to June 2015, we prospectively gathered data from 45 patients undergoing CAS in our centre, 19 of whom were excluded either due to medical contraindications or logistic obstacles to CT perfusion (n=6), or because they declined to participate (n=13). Our final sample included 26 patients, who were classified into 3 groups according to the degree of carotid artery stenosis: <90%, ≥90%, and bilateral stenosis. The patients with bilateral stenosis underwent revascularisation in the symptomatic carotid artery. None of the patients had any contraindication to contrast agents. All patients underwent CT perfusion scans before (2-10 days) and after CAS (2-10 days); imaging studies were performed at least 5 days after the last ischaemic event in all cases.

Diagnosis and treatment of carotid artery stenosis

Carotid artery stenosis was identified using duplex ultrasonography and subsequently measured with digital subtraction angiography (DSA), following the NASCET criteria.10 Presence of intracranial stenosis was ruled out with DSA. Presence of >50% stenosis in both carotid arteries was classified as bilateral stenosis. CAS was performed by one or 2 interventional neuroradiologists with over 15 years of experience. Patients were treated with antiplatelets (300mg acetylsalicylic acid+75mg clopidogrel) for 3 days prior to the procedure. All patients were treated with a self-expanding stent (Zilver vascular stent; Cook Ireland Ltd, Limerick, Ireland) and an embolic protection device (ANGIOGUARD; J&J Cordis, New Brunswick, USA). They received systemic anticoagulation during CAS; after the procedure, they were treated with acetylsalicylic acid plus clopidogrel for 3 months, followed by acetylsalicylic acid in monotherapy.

Analysis of CT perfusion data

CT perfusion was performed using a helical scanner with a 64-row detector (LightSpeed VCT; General Electric, USA). Images were taken at the level of the basal ganglia, with the following acquisition parameters: 0.625-mm collimation (1-second cycle time), 80kV, 120mA. Each scan was performed with a dose-length product of 1565.19mGy-cm. We injected a 50-mL bolus of iodinated contrast agent (Ultravist 300; Schering, Berlin, Germany), followed by 35mL of physiological saline (0.9%) at a flow rate of 4mL/s. Data were processed using a workstation with specialised software (CT Perfusion 4D Neuro; GE Healthcare, USA) to generate maps with absolute mean values for cerebral blood flow (CBF), in mL/100g/min; cerebral blood volume (CBV), in mL/100g; and mean transit time (MTT), time to peak (TP), and time to peak of the residue function (Tmax), in seconds.

Several studies have shown that absolute CT perfusion values are subject to inter- and intra-individual variations resulting from such physiological factors as arterial blood pressure, as well as post-processing steps.11–13 Using relative perfusion parameters may help overcome these limitations. We therefore calculated ratios of perfusion values between both hemispheres for the parameters CBF and CBV (rCBF and rCBV), as well as absolute interhemispheric differences in MTT, TP, and Tmax (dMTT, dTP, and dTmax), as recommended by other authors.14

Quantitative analyses measured mean values in regions of interest (ROI) in different vascular territories of the brain; we either drew ROIs manually15 or placed circular ROIs.13,16 To evaluate these maps, we placed 2 bilateral circular ROIs at the level of the basal ganglia, 3cm above the sella turcica, in the deep middle cerebral artery (MCA) territory, and manually drew 2 additional ROIs at the level of the cortex, in the surface MCA territory, according to the templates provided by Damasio17 (Fig. 1).

Figure 1.

Positioning of the regions of interest. Example of how the regions of interest were placed in the deep and surface middle cerebral artery territories to measure CT perfusion parameters.

(0.24MB).
Definition of false ischaemic penumbra and false ischaemic core

Visual interpretation of CT perfusion images is based on the analysis of colour perfusion maps, comparing the ischaemic lesion with the surrounding tissue and the contralateral area.18,19 The ischaemic penumbra was measured using a Tmax threshold of >6s20,21 and a CBV threshold of <1mL/100g,22 as per the most recent recommendations. Areas with Tmax alterations and normal CBV values, covering over 50% of the MCA territory, on CT perfusion were classified as FIPs. Areas with alterations in Tmax and CBV values, covering over 25% of the MCA territory, were classified as false ischaemic cores.

Statistical analysis

We performed a descriptive analysis of the patients’ baseline characteristics. The t test for paired samples was used to determine the differences in rCBF, rCBV, dMTT, dTP, and dTmax in the deep and surface MCA territories before and after CAS. We performed an analysis of covariance to compare the means between the 3 study groups. The relationship between FIPs and the degree of carotid artery stenosis was obtained with the chi square test; we used the Fisher exact test when necessary. The two-tailed significance level was set at P<.05 for all comparisons. Statistical analysis was performed using Stata/IC version 13.1 (StataCorp, Texas, USA).

Results

CT perfusion scans were performed before (mean of 53.8hours) and after CAS (mean of 42.2hours) in 26 patients. Mean time between the last ischaemic event and CAS was 21 days. Baseline clinical and carotid artery disease characteristics are listed in Table 1.

Table 1.

Summary of baseline clinical and carotid artery stenosis characteristics of the patient sample.

Baseline characteristics
Mean age, years (range)  69 (54-83) 
Men  18 (69%) 
Arterial hypertension  19 (73%) 
Hyperlipidaemia  16 (62%) 
Diabetes mellitus  10 (38%) 
Tobacco use  7 (27%) 
History of AMI  4 (15%) 
Peripheral artery disease  5 (19%) 
Clinical characteristics
NIHSS score before CAS
18 (69%) 
1-4  5 (19%) 
5-10  3 (11%) 
>10 
mRS score before CAS
≤2  19 (73%) 
3-4  7 (27%) 
>4 
Carotid artery stenosis
Location
Unilateral  16 (62%) 
Bilateral  10 (38%) 
Side undergoing CAS
Left  15 (58%) 
Right  11 (42%) 
Degree of treated stenosis
Unilateral stenosis
<90%  11 (69%) 
≥90%  5 (31%) 
Bilateral stenosis
<90%  3 (30%) 
≥90%  7 (70%) 
Median time between symptom onset and CAS, days  21 

AMI: acute myocardial infarction; CAS: carotid angioplasty and stenting; mRS: modified Rankin Scale; NIHSS: National Institutes of Health Stroke Scale.

The degree of stenosis in the treated carotid artery ranged from 50% to 99%; 16 patients had unilateral stenosis (11 patients with <90% stenosis and 5 patients with ≥90% stenosis) and 10 patients had bilateral stenosis. In the patients with bilateral stenosis, the treated stenosis was ≥90% in 3 patients and <90% in 7 patients, and the untreated carotid artery had <90% stenosis in 5 patients, 90%-99% stenosis in one patient, and occlusion in the remaining 4.

Quantitative analysis of CT perfusion images before and after carotid angioplasty and stenting

We performed a quantitative study of CT perfusion parameters in the deep and surface MCA territories and compared values obtained before and after CAS. Differences were statistically significant for rCBF, dMTT, dTP, and dTmax (P<.05). No statistically significant changes in rCBV were observed in any of the territories studied (Table 2).

Table 2.

Comparison of CT perfusion parameters in the deep and surface middle cerebral artery territories before and after carotid angioplasty and stenting.

CT perfusion parameter in the dMCA and sMCA territories  Before CAS  After CAS  Difference pre-post CAS  P 
rCBF
dMCA  0.95±0.17  1.04±0.10  −0.08±0.17  .02 
sMCA  0.97±0.23  1.05±0.12  −0.07±0.17  .03 
rCBV
dMCA  1.03±0.13  1.03±0.14  0.00±0.08  .95 
sMCA  1.04±0.14  1.06±0.13  −0.02±0.09  .25 
dMTT
dMCA  1.20±2.73  −0.13±2.74  1.30±3.00  .04 
sMCA  0.9±2.50  0.14±1.35  0.79±1.82  .03 
dTP
dMCA  0.46±1.64  −0.36±1.07  0.82±1.27  <.01 
sMCA  0.89±2.18  −0.26±1.01  1.15±1.63  <.01 
dTmax
dMCA  0.50±1.46  −0.18±0.76  0.69±0.94  <.01 
sMCA  0.63±1.66  0.00±0.77  0.64±1.17  .01 

The two-tailed significance level was set at P<.05 for all comparisons.

CAS: carotid angioplasty and stenting; CT: computed tomography; dMCA: deep middle cerebral artery territory; dMTT: relative mean transit time; dTmax: relative time to peak of the residue function; dTP: relative time to peak; P: level of significance; rCBF: relative cerebral blood flow; rCBV: relative cerebral blood volume; sMCA: surface middle cerebral artery territory.

The group with unilateral ≥90% stenosis displayed the most marked differences between CT perfusion parameters measured before and after CAS. These intergroup differences were significant except for CBV in all territories and CBF in the deep MCA territory (Table 3).

Table 3.

Comparison of CT perfusion parameters in the deep and surface middle cerebral artery territories before and after carotid angioplasty and stenting, broken down by degree of stenosis.

CT perfusion parameter in the dMCA and sMCA territories  Difference pre-post CASP 
  Carotid artery stenosis ≥90%  Carotid artery stenosis <90%  Bilateral carotid artery stenosis   
rCBF
dMCA  −0.21±0.17  −0.05±0.12  −0.04±0.19  .13 
sMCA  −0.23±0.13  −0.03±0.15  −0.03±0.16  .03 
rCBV
dMCA  0.03±0.69  0.00±0.10  −0.02±0.08  .52 
sMCA  0.01±0.08  −0.07±0.11  0.01±0.8  .10 
dMTT
dMCA  2.48±1.68  −0.26±2.33  2.15±3.66  .01 
sMCA  2.57±2.21  −0.04±1.05  0.56±1.62  .01 
dTP
dMCA  2.40±1.25  0.25±0.66  0.45±0.60  <.01 
sMCA  3.10±2.53  0.60±0.67  0.59±0.86  <.01 
dTmax
dMCA  2.07±0.72  0.22±0.62  0.32±0.58  <.01 
sMCA  2.27±0.81  0.05±0.56  0.24±0.91  <.01 

The two-tailed significance level was set at P<.05 for all comparisons.

CAS: carotid angioplasty and stenting; CT: computed tomography; dMCA: deep middle cerebral artery territory; dMTT: relative mean transit time; dTmax: relative time to peak of the residue function; dTP: relative time to peak; P: level of significance; rCBF: relative cerebral blood flow; rCBV: relative cerebral blood volume; sMCA: surface middle cerebral artery territory.

Analysis of false ischaemic penumbras and false ischaemic cores in CT perfusion images before and after carotid angioplasty and stenting

A total of 10 patients (38.5%) showed FIPs in pre-CAS CT perfusion images (Fig. 2). Of these, 6 patients had unilateral carotid artery stenosis (incidence of 37.5%): 5 patients had ≥90% stenoses (incidence of 100%) and only one patient had <90% stenosis (incidence of 9.1%). The relative risk of FIP in patients with unilateral stenosis ≥90% compared to the <90% stenosis group is 11 (95% CI, 1.70-71.3, P=.0005). All FIPs disappeared after CAS.

Figure 2.

Examples of digital subtraction angiography images and CT perfusion parametric maps (Tmax-CBV) before (a and b) and after carotid angioplasty and stenting (c and d).

(0.16MB).

We identified FIPs in 4 patients with bilateral carotid artery stenoses (40%). Three of these displayed FIPs in the hemisphere with the highest degree of stenosis (carotid artery occlusion). In the fourth patient, the FIP was located in the hemisphere with less severe (80% vs 95% in the contralateral hemisphere) but symptomatic stenosis. The group of patients with bilateral stenoses showed no changes in post-CAS CT perfusion parameters. None of the participants displayed false ischaemic cores.

Discussion

We observed changes in different CT perfusion parameters secondary to carotid artery stenosis. A time period of at least 5 days between the ischaemic event and CAS was a necessary condition for inclusion in the study. Thus, CT perfusion changes are affected exclusively by carotid artery stenosis, rather than by a true ischaemic penumbra. These changes involve a high incidence of FIP, which may lead to diagnostic errors.

The phenomenon of increased MTT and TP in the hemisphere ipsilateral to the stenosis has been recognised for over 10 years. More recent studies report changes in other CT perfusion parameters such as CBV or CBF, affecting both the deep and surface MCA territories.7,20 These changes may be attributed to carotid artery stenosis since they normalise after revascularisation with CAS, as shown in studies similar to our own.7,23 The fact that our patients underwent CT perfusion scans after the acute phase of ischaemic stroke enabled us to isolate the effect of the event on functional imaging studies; in this case, stenosis was the only factor influencing perfusion.

In line with previous studies, we found a strong association between alterations in CT perfusion parameters and the degree of stenosis, especially in patients with severe stenoses (≥90%).24 Our results are consistent with those of studies using transcranial Doppler ultrasound, which report decreases in MCA peak systolic velocity and the pulsatility index ipsilateral to severe carotid artery stenosis.25

CT perfusion data analysis was performed with a software tool based on the mathematical model of deconvolution, which is more precise than other options,26 particularly for estimating perfusion in patients with carotid artery stenosis.27 However, our results show that carotid artery stenosis continues to cause FIP on CT perfusion images, despite using this tool, resulting in obvious limitations for clinical practice.

False ischaemic cores were not detected in any patient on CT perfusion images. This is consistent with the lack of significant differences in CBV between pre-CAS and post-CAS images; the latter was the only parameter that remained unaltered. This demonstrates that CBV is a consistent parameter not vulnerable to haemodynamic changes secondary to carotid artery stenosis. In line with this idea, and contrary to our results, Chin et al.9 found significantly lower CBV in pre-CAS images than in post-CAS images; these authors used the maximum slope model for mathematical analysis. However, results based exclusively on a quantitative analysis of CT perfusion data may not be clinically relevant since the difference in CBV between pre-CAS and post-CAS images was only 0.03mL/100g; this difference, though statistically significant, is insufficient to cause false ischaemic cores with threshold values.

The definition of valid thresholds to determine the penumbra and core areas with CT perfusion imaging is a highly controversial issue. In addition to these 2 concepts, which make reference to at-risk tissue and infarcted tissue, respectively, we should also consider the concept of benign oligaemia (slightly hypoperfused brain tissue with no risk of infarction).

The boundaries between penumbra and benign oligaemia are not well defined. Some authors have suggested that the area of benign oligaemia may be excluded using a Tmax threshold of >6s, as shown in MRI studies.20,21 A relative MTT of 145% has also been proposed,23 although this criterion is less widely accepted.20 The fact that our patients were clinically stable, with symptoms appearing at least 5 days before the CT perfusion scan, rules out the hypothesis that changes were caused by true ischaemic penumbras.

To our knowledge, this is the first study evaluating changes in Tmax in patients with carotid artery stenosis. We observed increases of nearly 0.7s, which disappeared after CAS, demonstrating that the boundary between penumbra and benign oligaemia in these patients has not yet been successfully established.

Although multiple studies have described quantitative CT perfusion changes secondary to carotid artery stenosis, no prospective studies have evaluated the extent to which these changes may lead to diagnostic errors when interpreting CT perfusion images.24 Ours is the first prospective study to demonstrate a direct correlation between the degree of carotid artery stenosis and presence of FIP.

The phenomenon of FIP is more complex in patients with bilateral stenosis. Unlike in the case of unilateral stenosis, FIPs in patients with bilateral stenosis do not always appear in the hemisphere with the most severe stenosis. Patients with bilateral stenosis and occlusion of one of the carotid arteries usually display a FIP ipsilateral to the occlusion, which, logically, persists after treating the non-occluded artery. The small number of patients with bilateral stenosis in our sample prevents us from drawing robust conclusions on FIP in these patients.

Carotid artery stenosis is responsible for nearly 11% of ischaemic events28; in these cases, CT perfusion is frequently used for decision-making during the acute phase. In view of the high incidence of FIP in this group of patients, we recommend performing a study of the supra-aortic trunks prior to interpreting CT perfusion images in order to avoid diagnostic errors in patients with acute ischaemic stroke. In addition to acknowledging this limitation, it would be desirable to develop algorithms to correct for the effect of carotid artery stenosis on CT perfusion parameters, improving the reliability of data on penumbra.

Carotid artery stenosis is associated with a high risk of FIP, especially in patients with a high degree of stenosis; FIP resolves after treatment with CAS. The possibility of false-positive results, i.e. FIP, must always be considered when assessing CT perfusion images; while we await more precise diagnostic tools, analysis of the correlation between clinical findings and angiography results is essential.

Study limitations

We did not assess perfusion parameters with standard tools, such as PET or xenon-enhanced CT. However, previous studies have shown an adequate correlation between the values obtained with CT perfusion and those obtained with standard techniques for identifying the penumbra.29

We did not evaluate the effects of the configuration of the circle of Willis or other mechanisms of collateral supply, such as flow direction in the ophthalmic arteries or collateral circulation via leptomeningeal vessels. In any case, while collateral pathways may change vascular territories, they do not limit the validity of results once the territories have been defined.

Our results do not allow us to draw conclusions about prognosis, such as the likelihood of cerebral hyperperfusion syndrome, which has been evaluated in other studies.9 Further prospective studies with larger samples and longer follow-up times should be carried out to address this and other issues.

Conflicts of interest

The authors have no conflicts of interest to declare.

Acknowledgements

The authors would like to thank Dr Canneti for her scientific support and assistance in drafting the manuscript, and Dr Cuéllar for his valuable contributions to this study.

References
[1]
J.C. Baron.
Perfusion thresholds in human cerebral ischemia: historical perspective and therapeutic implications.
Cerebrovasc Dis, 11 (2001), pp. 2-8
[2]
L.C. Shih, J.L. Saver, J.R. Alger, S. Starkman, M.C. Leary, F. Vinuela, et al.
Perfusion-weighted magnetic resonance imaging thresholds identifying core, irreversibly infarcted tissue.
[3]
S. Warach.
New imaging strategies for patient selection for thrombolytic and neuroprotective therapies.
Neurology, 57 (2001), pp. S48-S52
[4]
G.W. Albers, V.N. Thijs, L. Wechsler, S. Kemp, G. Schlaug, E. Skalabrin, et al.
Magnetic resonance imaging profiles predict clinical response to early reperfusion: the diffusion and perfusion imaging evaluation for understanding stroke evolution (DEFUSE) study.
Ann Neurol, 60 (2006), pp. 508-517
[5]
B.C. Campbell, P.J. Mitchell, T.J. Kleinig, H.M. Dewey, L. Churilov, N. Yassi, et al.
Endovascular therapy for ischemic stroke with perfusion-imaging selection.
N Engl J Med, 372 (2015), pp. 1009-1018
[6]
A.C. Best, N.R. Acosta, J.E. Fraser, M.T. Borges, K.E. Brega, T. Anderson, et al.
Recognizing false ischemic penumbras in CT brain perfusion studies.
Radiographics, 32 (2012), pp. 1179-1196
[7]
A. Trojanowska, A. Drop, T. Jargiello, J. Wojczal, M. Szczerbo-Trojanowska.
Changes in cerebral hemodynamics after carotid stenting: Evaluation with CT perfusion studies.
J Neuroradiol, 33 (2006), pp. 169-174
[8]
A. Waaijer, M.S. van Leeuwen, M.J. van Osch, B.H. van der Worp, F.L. Moll, R.T. Lo, et al.
Changes in cerebral perfusion after revascularization of symptomatic carotid artery stenosis: CT measurement.
Radiology, 245 (2007), pp. 541-548
[9]
S.C. Chin, C.H. Chang, T.Y. Chang, K.L. Huang, T.C. Wu, J.R. Lin, et al.
Brain computed tomography perfusion may help to detect hemodynamic reconstitution and predict intracerebral hemorrhage after carotid stenting.
J Vasc Surg, 56 (2012), pp. 1281-1290
[10]
North American Symptomatic Carotid Endarterectomy Trial.
Methods, patient characteristics, and progress.
Stroke, 22 (1991), pp. 711-720
[11]
L.M. Parkes, W. Rashid, D.T. Chard, P.S. Tofts.
Normal cerebral perfusion measurements using arterial spin labeling: reproducibility, stability, and age and gender effects.
Magn Reson Med, 51 (2004), pp. 736-743
[12]
A.S. Field, P.J. Laurienti, Y.F. Yen, J.H. Burdette, D.M. Moody.
Dietary caffeine consumption and withdrawal: confounding variables in quantitative cerebral perfusion studies?.
Radiology, 227 (2003), pp. 129-135
[13]
D. Fiorella, J. Heiserman, E. Prenger, S. Partovi.
Assessment of the reproducibility of postprocessing dynamic CT perfusion data.
AJNR, 25 (2004), pp. 97-107
[14]
A. Waaijer, I.C. van der Schaaf, B.K. Velthuis, M. Quist, M.J. van Osch, E.P. Vonken, et al.
Reproducibility of quantitative CT brain perfusion measurements in patients with symptomatic unilateral carotid artery stenosis.
AJNR, 28 (2007), pp. 927-932
[15]
M. Koenig, M. Kraus, C. Theek, E. Klotz, W. Gehlen, L. Heuser.
Quantitative assessment of the ischemic brain by means of perfusion-related parameters derived from perfusion CT.
Stroke, 32 (2001), pp. 431-437
[16]
E.G. Hoeffner, I. Case, R. Jain, S.K. Gujar, G.V. Shah, J.P. Deveikis, et al.
Cerebral perfusion CT: technique and clinical applications.
Radiology, 231 (2004), pp. 632-644
[17]
H. Damasio.
A computed tomographic guide to the identification of cerebral vascular territories.
Arch Neurol, 40 (1983), pp. 8-142
[18]
J.D. Eastwood, M.H. Lev, M. Wintermark, C. Fitzek, D.P. Barboriak, D.M. Delong, et al.
Correlation of early dynamic CT perfusion imaging with whole-brain MR diffusion and perfusion imaging in acute hemispheric stroke.
AJNR, 24 (2003), pp. 1869-1875
[19]
J.R. Reichenbach, J. Rother, L. Jonetz-Mentzel, M. Herzau, A. Fiala, C. Weiller, et al.
Acute stroke evaluated by time-to-peak mapping during initial and early follow-up perfusion CT studies.
AJNR, 20 (1999), pp. 1842-1850
[20]
S. Davis, G.A. Donnan.
Time is penumbra: imaging, selection and outcome. The Johann jacob wepfer award 2014.
Cerebrovasc Dis, 38 (2014), pp. 59-72
[21]
B.C. Campbell, S. Christensen, C.R. Levi, P.M. Desmond, G.A. Donnan, S.M. Davis, et al.
Comparison of computed tomography perfusion and magnetic resonance imaging perfusion-diffusion mismatch in ischemic stroke.
Stroke, 43 (2012), pp. 2648-2653
[22]
W.A. Copen, L.T. Morais, O. Wu, L.H. Schwamm, P.W. Schaefer, R.G. Gonzalez, et al.
In acute stroke, can CT perfusion-derived cerebral blood volume maps substitute for diffusion-weighted imaging in identifying the ischemic core?.
PLOS ONE, 10 (2015), pp. e0133566
[23]
J. Van der Heyden, A. Waaijer, E.S. dan Wouter, D. van Neerven, U. Sonker, M.J. Suttorp, et al.
CT measurement of changes in cerebral perfusion in patients with asymptomatic carotid artery stenosis undergoing carotid stenting prior to cardiac surgery: proof of principle.
EuroIntervention, 6 (2011), pp. 1091-1097
[24]
L.M. Jongen, H.B. van der Worp, A. Waaijer, Y. van der Graaf, W.P. Mali.
Interrelation between the degree of carotid stenosis, collateral circulation and cerebral perfusion.
Cerebrovasc Dis, 30 (2010), pp. 277-284
[25]
P.A. Schneider, M.E. Rossman, E.F. Bernstein, S. Torem, E.B. Ringelstein, S.M. Otis.
Effect of internal carotid artery occlusion on intracranial hemodynamics transcranial Doppler evaluation and clinical correlation.
Stroke, 19 (1988), pp. 589-593
[26]
J. Donahue, M. Wintermark.
Perfusion CT and acute stroke imaging: foundations, applications, and literature review.
J Neuroradiol, 42 (2015), pp. 21-29
[27]
A.A. Konstas, G.V. Goldmakher, T.Y. Lee, M.H. Lev.
Theoretic basis and technical implementations of CT perfusion in acute ischemic stroke, part 2: technical implementations.
AJNR, 30 (2009), pp. 885-892
[28]
L. Li, G.S. Yiin, O.C. Geraghty, U.G. Schulz, W. Kuker, Z. Mehta, et al.
Incidence, outcome, risk factors, and long-term prognosis of cryptogenic transient ischaemic attack and ischaemic stroke: a population-based study.
Lancet Neurol, 14 (2015), pp. 903-913
[29]
M. Wintermark, J.P. Thiran, P. Maeder, P. Schnyder, R. Meuli.
Simultaneous measurement of regional cerebral blood flow by perfusion CT and stable xenon CT: a validation study.
AJNR, 22 (2001), pp. 905-914

Please cite this article as: Mosqueira AJ, Pumar JM, Arias S, Rodríguez-Yáñez M, Blanco Ulla M, Vázquez Herrero F, et al. Falsas penumbras isquémicas en la TC de perfusión en pacientes con estenosis carotídea y cambios después de la angioplastia y stenting. Neurología. 2020;35:24–31.

This study is part of a doctoral thesis currently underway at Universidad de Santiago de Compostela.

Copyright © 2017. Sociedad Española de Neurología
Descargar PDF
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos