covid
Buscar en
Revista Colombiana de Anestesiología
Toda la web
Inicio Revista Colombiana de Anestesiología Intubación de paciente despierto con fibroscopio rígido bajo sedación con rem...
Información de la revista
Vol. 38. Núm. 3.
Páginas 395-401 (agosto - octubre 2010)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Vol. 38. Núm. 3.
Páginas 395-401 (agosto - octubre 2010)
REPORTE DE CASOS
Open Access
Intubación de paciente despierto con fibroscopio rígido bajo sedación con remifentanil
Rigid fiberscope intubation of a patient awake with remifentanil sedation
Visitas
4210
Juan Carlos Bocanegra
, Ángela María Ríos Medina**, Óscar David Aguirre Ospina***
* MD. Especialista en Anestesiología y Reanimación, Hospital SES de Caldas. Manizales, Colombia.
** MD. Residente de Anestesiología y Reanimación. Universidad de Caldas. Manizales. Colombia.
*** MD. Residente de Anestesiología y Reanimación. Universidad de Caldas. Manizales. Colombia.
Este artículo ha recibido

Under a Creative Commons license
Información del artículo
RESUMEN
Introducción

Al elegir el manejo de un paciente con vía aérea difícil, conocida o sospechada, es importante plantearse alternativas de intervención. Varios algoritmos de manejo, recomiendan la intubación con paciente despierto, con laringoscopia directa o instrumentos ópticos. Los estiletes rígidos y semirrígidos son dispositivos ópticos desarrollados para el manejo de la vía aérea difícil, que han mostrado ser rápidos, atraumáticos y confiables.

Objetivos

Describir el uso de diferentes estrategias de abordaje de la vía aérea difícil en el escenario de cirugía urgente, al utilizar como una de las opciones de manejo el dispositivo Airway RIFL (rigid intubation fiberoptic laryngoscope).

Metodología y resultados

Este es el caso de un paciente de 69 años, llevado de urgencia a cirugía para hemostasia de lesión neoplásica en tórax, considerado como vía aérea difícil por antecedente de múltiples resecciones de lesiones tumorales y radioterapia en vía aérea, con secuela de marcada deformidad facial. Intubación con estómago lleno. Se plantea como primera opción en el manejo de la via aérea el uso de anestesia tópica, sedación con remifentanil y laringoscopia directa, lo cual no es posible por limitada apertura oral: se intenta en tres ocasiones intubación nasal, la cual es fallida. Se decide intubación con el dispositivo Airway RIFL, la cual es exitosa.

Conclusiones

Dentro del enfoque del paciente considerado como vía aérea difícil, contar con varias estrategias de manejo, la analgesia local y la sedación, permiten una excelente colaboración por parte del paciente y una rápida intubación orotraqueal con fibroscopio rígido, incluso en escenarios de urgencia.

Palabras clave:
Intubación intratraqueal
dispositivos ópticos
anestesia
sedación consciente
neumonía por aspiración (fuente DeCS, BIREME)
SUMMARY
Introduction

When choosing the appropriate management for a difficult airway patient, either established or suspected, several intervention options should be considered. Some management algorithms recommend awake intubation under direct laryngoscopy or optical instruments. Rigid and semi-rigid stylets are optical devices developed for managing the difficult airway that have proven to be fast, non-traumatic and reliable.

Objectives

To describe the use of different strategies to approach the difficult airway in an emergency surgery, using the Airway RIFL (rigid intubation fiberoptic laryngoscope) as one of the options.

Methodology and results

This is a case of a 69-yr old patient admitted to the ER for hemostasis and surgery of a chest neoplasia. The patient was considered a difficult airway patient because of a history of multiple tumor resections and radiotherapy in the airway, resulting in a notorious facial deformity. Intubation on a full stomach. Topical anesthesia was considered the first choice for airway management, remifentanil sedation and direct laryngoscopy but this is not possible due to a limited oral opening: three nasal intubation attempts were made but failed. Then it was decided to use the Airway RIFL device and the procedure was successful.

Conclusions

When dealing with a difficult airway patient, having several management strategies at hand, local anesthesia and sedation, allow for excellent patient collaboration and a fast orotracheal intubation using a rigid fiberscope, even under emergency situations.

Keywords:
Endotracheal intubation
optical devices
anesthesia
awake sedation
aspiration pneumonia
El Texto completo está disponible en PDF
REFERENCES
[1.]
W. McEwan.
Clinical observations on the introduction of tracheal tubes by the mouth instead of performing tracheotomy or laryngotomy.
BMJ, 2 (1880), pp. 163-165
[2.]
I.W. Magill.
Endotracheal anaesthesia.
Proc R Soc Med, 22 (1928), pp. 83-88
[3.]
R.R. Macintosh.
A new laryngoscope.
Lancet, 1 (1943), pp. 205
[4.]
L. Davis, S. Cook-Sather, M. Schreiner.
Lighted stylet tracheal intubation: a review.
Anesth Analg, 90 (2000), pp. 745-756
[5.]
C.A. Marco, A.P. Marco.
Airway adjuncts.
Emerg Med Clin N Am, 26 (2008), pp. 1015-1027
[6.]
R.M. Levitan, S. Kush, J.E. Hollander.
Devices for difficult airway management in academic emergency departments: results of a national survey.
Ann Emerg Med, 33 (1999), pp. 694-698
[7.]
T.J. Reeder, C.K. Brown, D.L. Norris.
Managing the difficult airway: a survey of residency directors and a call for change.
J Emerg Med, 28 (2005), pp. 473-478
[8.]
T. Ezri, P. Szmuk, R.D. Warters, J. Katz, C.A. Hagberg.
Difficult airway management practice patterns among anesthesiologists practicing in the United States: have we made any progress?.
J Clin Anesth, 15 (2003), pp. 418-422
[9.]
E.B. Liem, D.G. Bjoraker, D. Gravenstein.
New options for airway management: intubating fibreoptic stylets.
Br J Anaesth, 91 (2003), pp. 408-418
[10.]
L. Pfitzner, M.G. Cooper, D. Ho.
The Shikani Seeing Stylet for difficult intubation in children: initial experience.
Anaesth Intensive Care, 30 (2002), pp. 462-466
[11.]
F. Gempeler, A. Devis, P. Pedraza.
Intubación con paciente despierto con fibroscopio retromolar de Bonfils bajo sedación con dexmedetomidina. Reporte de 7 casos.
Rev Col Anest, 37 (2009), pp. 49-56
[12.]
G. Kovacs, A. Law, D. Petrie.
Awake fiberoptic intubation using an optical stylet in ananticipated dificult airway.
Ann Emerg Med, 49 (2007), pp. 81-83
[13.]
J. Brimacombe, C. Keller, K.H. Künzel, O. Gaber, M. Boehler, F. Pühringer.
Cervical spine motion during airway management:a cinefluoroscopic study of the posteriorly destabilized third vertebrae in human cadavers.
Anesth Analg, 91 (2000), pp. 1274-1278
[14.]
C. Rudolph, M. Schlender.
Clinical experiences with fiber optic intubation with the Bonfils intubation fiberscope.
Anaesthesiol Reanim, 21 (1996), pp. 127-130
[15.]
C.A. Hagberg.
Special devices and techniques.
Anesthesiology Clin N Am, 20 (2002), pp. 907-932
[16.]
O. Hung, M. Murphy.
Management of the difficult and failed airway.
McGraw Hill, (2007),
Copyright © 2010. Revista Colombiana de Anestesiología
Descargar PDF
Opciones de artículo