metricas
covid
Buscar en
Revista Española de Medicina Nuclear e Imagen Molecular
Toda la web
Inicio Revista Española de Medicina Nuclear e Imagen Molecular Uso de análisis semicuantitativo en la recidiva local del carcinoma colorrectal...
Información de la revista
Vol. 37. Núm. 6.
Páginas 366-372 (noviembre - diciembre 2018)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Visitas
48
Vol. 37. Núm. 6.
Páginas 366-372 (noviembre - diciembre 2018)
Original
Uso de análisis semicuantitativo en la recidiva local del carcinoma colorrectal mediante PET/TC con 18F-FDG: ¿mito o realidad?
Use of semiquantitative analysis in local recurrence of colorectal carcinoma with 18F-FDG PET/CT: A myth or a truth?
Visitas
48
G.K. Gedik
Autor para correspondencia
goncakara@selcuk.edu.tr

Autor para correspondencia.
, F. Yilmaz
Department of Nuclear Medicine, Faculty of Medicine, Selcuk University, Konya, Turquía
Este artículo ha recibido
Disponible módulo formativo: Unidad 3. Saber más
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (4)
Mostrar másMostrar menos
Tablas (2)
Tabla 1. Detalles de los pacientes con aumento de la captación de 18F-FDG en la zona quirúrgica
Tabla 2. Resultados del análisis semicuantitativo de la captación benigna y maligna de la 18F-FDG en el área quirúrgica
Mostrar másMostrar menos
Resumen
Objetivo

La recurrencia del cáncer colorrectal aparece principalmente en los primeros 2 años después de la cirugía. El sitio de recidiva más frecuente es la región posquirúrgica y su entorno. El propósito de este estudio fue evaluar la utilidad del análisis semicuantitativo de la captación de 18Flúor-fluorodeoxiglucosa (18F-FDG) con tomografía por emisión de positrones/tomografía computarizada (PET/TC) para determinar la recurrencia del carcinoma colorrectal en el lugar de la intervención quirúrgica.

Material y métodos

Se analizaron de forma retrospectiva 35 pacientes con carcinoma colorrectal (25 hombres, 10 mujeres, edad media: 59,25±2,82 años, rango: 27-80 años) tratados con cirugía a los que se les realizó una PET/TC con 18F-FDG para reestadificación y que mostraron un aumento de la captación de 18F-FDG en la anastomosis. Además del cálculo de SUVmáx de las áreas que presentaron captación de 18F-FDG en el sitio de la intervención quirúrgica, también se obtuvo el SUVmáx de la actividad fisiológica del colon y se calculó el SUVmáx de la lesión/SUVmáx de la pared del colon (RSUVmáx). Las características de la captación de 18F-FDG se clasificaron de acuerdo con el análisis histológico o el seguimiento clínico y de estudios de imagen.

Resultados

En 17 de 35 pacientes (49%) el estándar de referencia para el diagnóstico final fue el análisis histológico y en 18 (51%), el diagnóstico final se basó en imágenes y seguimiento clínico. En 15 de 35 pacientes (43%) la etiología del aumento de la captación de 18F-FDG fue la recurrencia y en 20 (57%), la acumulación de 18F-FDG se observó debido a la etiología benigna. La diferencia entre la media de los resultados de SUVmáx en pacientes con enfermedad recurrente y sin evidencia de recurrencia fue estadísticamente significativa (p=0,030). Para SUVmáx se calculó un valor de corte de 9,51 con una sensibilidad del 80% y una especificidad del 70%. En términos de resultados RSUVmáx, también se observó una diferencia estadísticamente significativa entre los valores medios en pacientes con enfermedad recurrente y en los que no (p=0,002). El análisis ROC demostró que el mejor valor predictivo de RSUVmáx era 1,75 con una sensibilidad del 67% y una especificidad del 95%.

Conclusiones

El análisis semicuantitativo de PET/TC con 18F-FDG se puede usar para detectar enfermedad recurrente en pacientes con carcinoma colorrectal. La eliminación de la interferencia de la actividad fisiológica del colon en el análisis puede tener un efecto incremental sobre el éxito de esta técnica mediante el aumento de la especificidad.

Palabras clave:
Carcinoma colorrectal
Recurrencia
Actividad fisiológica
FDG PET/TC
Semicuantitativo
Abstract
Objective

Recurrence of colorectal cancer is mostly seen within the first 2 years after surgery. The most frequent site of recurrence is the postsurgical areas and its surroundings. The purpose of this study was to evaluate the usefulness of semiquantitative analysis of 18Fluorine fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) in determining recurrence of colorectal carcinoma in the operation site.

Material and methods

Files of 35 patients with colorectal carcinoma (25 men, 10 women, mean age: 59.25±2.82 years, range: 27-80 years) who were treated with surgery and underwent FDG PET/CT scanning for restaging of colorectal carcinoma and showing increased FDG uptake in the postsurgical area, were retrospectively analysed. Besides calculating SUVmax of the areas showing FDG uptake, SUVmax of physiological colonic activity was also obtained and SUVmax of lesion/SUVmax of colonic wall (RSUVmax), was calculated. Characteristics of FDG uptake were classified according to histological analysis or clinical and imaging follow-up.

Results

In 17 of 35 patients (49%) the standard of reference for the final diagnosis was histologic analysis and in 18 (51%), final diagnosis was based on imaging and clinical follow-up. In 15 of 35 patients (43%) the etiology of increased FDG uptake was recurrence and in 20 (57%), FDG accumulation was observed due to benign etiology. The difference between the mean of the results of SUVmax in patients with recurrent disease and with no evidence of recurrence was statistically significant (P=.030). For SUVmax, a cut-off value for recurrence was calculated as 9.51 with a sensitivity of 80% and a specificity of 70%. In terms of RSUVmax results, a statistically significant difference was also observed between mean values in patients with recurrent disease and in those without (P=.002). ROC analysis demonstrated that the best predictive value of RSUVmax for recurrence was 1.75 with a sensitivity of 67% and specificity of 95%.

Conclusions

Semiquantitative analysis of FDG PET/CT may be used in detecting recurrent disease of patients with colorectal carcinoma. Eliminating interfering physiological colonic activity in analysis may have an incremental effect on the success of this technique, by means of increasing the specificity.

Keywords:
Colorectal carcinoma
Recurrence
Physiological activity
FDG PET/CT
Semiquantitative

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Medicina Nuclear e Imagen Molecular
Socio
Si es usted socio de la Sociedad Española de Medicina Nuclear e Imagen Molecular (SEMNIM) puede acceder al texto completo de los contenidos de la Revista Española de Medicina Nuclear e Imagen Molecular desde los enlaces a la revista publicados en la web de la SEMNIN (enlace a https://semnim.es/iniciar-sesion/), previo inicio de sesión como socio. Si tiene problemas de acceso puede contactar con la Secretaría Técnica de la SEMNIM en el correo electrónico secretaria.tecnica@semnim.es o en el teléfono: + 34 619 594 780
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Medicina Nuclear e Imagen Molecular

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos