metricas
covid
Buscar en
Acta Otorrinolaringológica Española
Toda la web
Inicio Acta Otorrinolaringológica Española Variación del parámetro acústico harmonic-to-noise ratio en relación con dis...
Journal Information
Vol. 72. Issue 3.
Pages 177-181 (May - June 2021)
Share
Share
Download PDF
More article options
Visits
26
Vol. 72. Issue 3.
Pages 177-181 (May - June 2021)
ARTÍCULO ORIGINAL
Variación del parámetro acústico harmonic-to-noise ratio en relación con distintos niveles de ruido de fondo
Variation of the acoustic parameter harmonic-to-noise ratio in relation to different background noise levels
Visits
26
María-José Marsano-Cornejoa,b,
Corresponding author
mj.marsano@uautonoma.cl

Autor para correspondencia.
, Ángel Roco-Videlac,d, Damián Capona-Corbalána, Carla Silva-Hartheya
a Facultad de Ciencias de la Salud, Universidad Autónoma de Chile, Santiago, Chile
b Facultad de Ciencias de la Salud, Universidad de Las Américas, Santiago, Chile
c Programa de Magister en Ciencias Químico-Biológicas, Facultad de Salud, Universidad Bernardo O’Higgins, Santiago, Chile
d Departamento de Ingeniería Civil, Facultad de Ingeniería,Universidad Católica de la Santísima Concepción, Concepción, Chile
This item has received
Article information
Abstract
Full Text
Bibliography
Download PDF
Statistics
Tables (1)
Tabla 1. Comparación estadística de los valores promedios de harmonic-to-noise ratio según distintos niveles de ruido de fondo
Resumen
Introducción y objetivos

El análisis acústico es una herramienta muy utilizada por los profesionales afines al estudio de la voz que permite obtener información de ella a partir de una grabación. Se ha identificado que en las investigaciones que se realizan hoy en día que involucran análisis acústico, se realiza el proceso de grabación en recintos con distintos niveles de ruido de fondo. El objetivo de este estudio es determinar si el parámetro acústico harmonic-to-noise ratio (HNR) varía en relación con los distintos niveles de ruido de fondo del recinto donde se realiza la grabación y determinar un valor máximo recomendado de ruido de fondo para esa sala.

Métodos

A través del programa Praat se obtuvo el valor promedio del parámetro acústico HNR de 43 sujetos, en el interior de la cabina audiométrica de la Universidad Autónoma de Chile, cuyo nivel de ruido de fondo es de 28,1dB(A), y se comparó con los valores promedio de HNR obtenidos con niveles de ruido de fondo superiores.

Resultados

Los valores promedios de HNR fueron disminuyendo desde 19,8 hasta 14,0dB(A) a medida que el nivel de ruido de fondo del recinto aumentaba de 28,1 a 57,8dB(A). Se realizó la prueba t para muestras dependientes, con la cual se compararon los valores de HNR promedio obtenidos con el nivel de ruido de fondo basal (28,1dB[A]). Se encontraron diferencias significativas con el nivel de ruido de fondo basal cuando el nivel de ruido de fondo de la sala era superior a 47,7dB(A).

Conclusiones

El ruido de fondo del recinto donde se realiza la grabación de voz necesaria para el análisis acústico influye en el valor del parámetro acústico HNR, el cual desciende a medida que el ruido de fondo del recinto aumenta. Se establece como valor máximo recomendado un nivel de ruido de fondo que no supere los 43,8dB(A).

Palabras clave:
Harmonic-to-noise ratio
Análisis acústico
Ruido de fondo
Voz
Praat
Abstract
Introduction and objectives

Acoustic analysis is a tool widely used by professionals related to the study of voice that gives us information from a recording. It has been identified that in investigations carried out today that involve acoustic analysis, the recording process takes place in rooms with different levels of background noise. The objective of this study is to establish whether the acoustic parameter harmonic-to-noise ratio (HNR) varies in relation to the different background noise levels of the premises where the recording is made and recommend a maximum level of background noise.

Methods

Through the Praat programme, the average value of the acoustic parameter HNR of 43 subjects was obtained, inside the audiometric booth of the Universidad Autónoma de Chile, whose background noise level is 28.1dB(A) and it was compared with the HNR average values obtained with higher background noise levels.

Results

The HNR average values decreased from 19.8 to 14.0dB(A) as the background noise level of the premises increased from 28.1 to 57.8dB(A). The t-test for dependent samples was performed, with which the HNR average values obtained were compared with the baseline background noise level (28.1dB[A]). Significant differences were found with the baseline background noise level when the room noise level was higher than 47.7dB(A).

Conclusions

The background noise of the premises where the voice recording for the acoustic analysis is performed, influences the value of the acoustic parameter HNR, which decreases as the background noise of the premises increases. It is recommended that the background noise level should not exceed 43.8dB(A).

Keywords:
Harmonic-to-noise ratio
Acoustic analysis
Background noise
Voice
Praat

Article

These are the options to access the full texts of the publication Acta Otorrinolaringológica Española
Subscriber
Subscriber

If you already have your login data, please click here .

If you have forgotten your password you can you can recover it by clicking here and selecting the option “I have forgotten my password”
Subscribe
Subscribe to

Acta Otorrinolaringológica Española

Purchase
Purchase article

Purchasing article the PDF version will be downloaded

Price 19.34 €

Purchase now
Contact
Phone for subscriptions and reporting of errors
From Monday to Friday from 9 a.m. to 6 p.m. (GMT + 1) except for the months of July and August which will be from 9 a.m. to 3 p.m.
Calls from Spain
932 415 960
Calls from outside Spain
+34 932 415 960
E-mail
Article options
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos