array:24 [ "pii" => "S0001651906786587" "issn" => "00016519" "doi" => "10.1016/S0001-6519(06)78658-7" "estado" => "S300" "fechaPublicacion" => "2006-01-01" "aid" => "78658" "copyright" => "Elsevier España, S.L.. Todos los derechos reservados" "copyrightAnyo" => "2001" "documento" => "article" "crossmark" => 0 "subdocumento" => "fla" "cita" => "Acta Otorrinolaringol Esp. 2006;57:24-7" "abierto" => array:3 [ "ES" => true "ES2" => true "LATM" => true ] "gratuito" => true "lecturas" => array:2 [ "total" => 4293 "formatos" => array:3 [ "EPUB" => 31 "HTML" => 2298 "PDF" => 1964 ] ] "itemSiguiente" => array:18 [ "pii" => "S0001651906786599" "issn" => "00016519" "doi" => "10.1016/S0001-6519(06)78659-9" "estado" => "S300" "fechaPublicacion" => "2006-01-01" "aid" => "78659" "copyright" => "Elsevier España, S.L." "documento" => "article" "crossmark" => 0 "subdocumento" => "fla" "cita" => "Acta Otorrinolaringol Esp. 2006;57:28-33" "abierto" => array:3 [ "ES" => true "ES2" => true "LATM" => true ] "gratuito" => true "lecturas" => array:2 [ "total" => 3120 "formatos" => array:3 [ "EPUB" => 27 "HTML" => 1560 "PDF" => 1533 ] ] "es" => array:10 [ "idiomaDefecto" => true "titulo" => "Estudio de comorbilidad de la hipoacusia neurosensorial y otras enfermedades de patogenia autoinmune. Utilidad de las pruebas de laboratorio" "tienePdf" => array:2 [ 0 => "es" 1 => "en" ] "tieneTextoCompleto" => 0 "tieneResumen" => array:2 [ 0 => "es" 1 => "en" ] "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "28" "paginaFinal" => "33" ] ] "titulosAlternativos" => array:1 [ "en" => array:1 [ "titulo" => "Cormobidity of sensorineural hearing loss and other autoimmune diseases. Usefulness of laboratory tests" ] ] "contieneResumen" => array:2 [ "es" => true "en" => true ] "contienePdf" => array:2 [ "es" => true "en" => true ] "autores" => array:2 [ 0 => array:2 [ "autoresLista" => "F.J. García Callejo, C. de Paula Vernetta, J. Ramírez Sabio, J. Marco Algarra" "autores" => array:4 [ 0 => array:2 [ "nombre" => "F.J." "apellidos" => "García Callejo" ] 1 => array:2 [ "nombre" => "C." "apellidos" => "de Paula Vernetta" ] 2 => array:2 [ "nombre" => "J." "apellidos" => "Ramírez Sabio" ] 3 => array:2 [ "nombre" => "J." "apellidos" => "Marco Algarra" ] ] ] 1 => array:2 [ "autoresLista" => "J. Corts, P. Laporta" "autores" => array:2 [ 0 => array:2 [ "nombre" => "J." "apellidos" => "Corts" ] 1 => array:2 [ "nombre" => "P." "apellidos" => "Laporta" ] ] ] ] ] "idiomaDefecto" => "es" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0001651906786599?idApp=UINPBA00004N" "url" => "/00016519/0000005700000001/v1_201304231440/S0001651906786599/v1_201304231440/es/main.assets" ] "itemAnterior" => array:18 [ "pii" => "S0001651906786575" "issn" => "00016519" "doi" => "10.1016/S0001-6519(06)78657-5" "estado" => "S300" "fechaPublicacion" => "2006-01-01" "aid" => "78657" "copyright" => "Elsevier España, S.L." "documento" => "article" "crossmark" => 0 "subdocumento" => "fla" "cita" => "Acta Otorrinolaringol Esp. 2006;57:2-23" "abierto" => array:3 [ "ES" => true "ES2" => true "LATM" => true ] "gratuito" => true "lecturas" => array:2 [ "total" => 4940 "formatos" => array:3 [ "EPUB" => 38 "HTML" => 2514 "PDF" => 2388 ] ] "es" => array:10 [ "idiomaDefecto" => true "titulo" => "Evaluación del implante coclear como técnica de tratamiento de la hipoacusia profunda en pacientes pre y post locutivos" "tienePdf" => array:2 [ 0 => "es" 1 => "en" ] "tieneTextoCompleto" => 0 "tieneResumen" => array:2 [ 0 => "es" 1 => "en" ] "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "2" "paginaFinal" => "23" ] ] "titulosAlternativos" => array:1 [ "en" => array:1 [ "titulo" => "Analysis of the cochlear implant as a treatment technique for profound hearing loss in pre and postlocutive patients" ] ] "contieneResumen" => array:2 [ "es" => true "en" => true ] "contienePdf" => array:2 [ "es" => true "en" => true ] "autores" => array:1 [ 0 => array:2 [ "autoresLista" => "M. Manrique, A. Ramos, C. Morera, C. Cenjor, M.J. Lavilla, M.S. Boleas, F.J. Cervera-Paz" "autores" => array:7 [ 0 => array:2 [ "nombre" => "M." "apellidos" => "Manrique" ] 1 => array:2 [ "nombre" => "A." "apellidos" => "Ramos" ] 2 => array:2 [ "nombre" => "C." "apellidos" => "Morera" ] 3 => array:2 [ "nombre" => "C." "apellidos" => "Cenjor" ] 4 => array:2 [ "nombre" => "M.J." "apellidos" => "Lavilla" ] 5 => array:2 [ "nombre" => "M.S." "apellidos" => "Boleas" ] 6 => array:2 [ "nombre" => "F.J." "apellidos" => "Cervera-Paz" ] ] ] ] ] "idiomaDefecto" => "es" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0001651906786575?idApp=UINPBA00004N" "url" => "/00016519/0000005700000001/v1_201304231440/S0001651906786575/v1_201304231440/es/main.assets" ] "es" => array:14 [ "idiomaDefecto" => true "titulo" => "Resultados audiológicos comparando prótesis de teflón <span class="elsevierStyleItalic">versus</span> prótesis alambre/teflón tipo Schucknecht" "tieneTextoCompleto" => 0 "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "24" "paginaFinal" => "27" ] ] "autores" => array:1 [ 0 => array:4 [ "autoresLista" => "M. Martín Félix Trujillo, J. Eduardo Ramírez" "autores" => array:2 [ 0 => array:4 [ "nombre" => "M." "apellidos" => "Martín Félix Trujillo" "email" => array:1 [ 0 => "felixt_mx@yahoo.com.mx" ] "referencia" => array:2 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">*</span>" "identificador" => "aff0005" ] 1 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">1</span>" "identificador" => "cor0005" ] ] ] 1 => array:3 [ "nombre" => "J." "apellidos" => "Eduardo Ramírez" "referencia" => array:1 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">**</span>" "identificador" => "aff0010" ] ] ] ] "afiliaciones" => array:2 [ 0 => array:3 [ "entidad" => "Médico Cirujano Otorrinolaringólogo. Otólogo. Maestro en Ciencias" "etiqueta" => "<span class="elsevierStyleSup">*</span>" "identificador" => "aff0005" ] 1 => array:3 [ "entidad" => "Jefe del departamento de Audiología y Otoneurología. Servicio de Otorrinolaringología y Cirugía de Cabeza y Cuello. Unidad Médica de alta especialidad. Hospital General “Dr. Gaudencio González Garza”. Centro Médico Nacional “La Raza”. México D.F" "etiqueta" => "<span class="elsevierStyleSup">**</span>" "identificador" => "aff0010" ] ] "correspondencia" => array:1 [ 0 => array:3 [ "identificador" => "cor0005" "etiqueta" => "1" "correspondencia" => "Correspondencia: Flores Magón 209, edificio Aldama, Entrada F, Departamento 221. Col. Tlatelolco, Delegación Cuahutémoc. CP. 06900 México" ] ] ] ] "titulosAlternativos" => array:1 [ "en" => array:1 [ "titulo" => "Auditory results used to compare a Teflon prosthesis vs a Schucknecht type wire/Teflon prosthesis" ] ] "pdfFichero" => "main.pdf" "tienePdf" => true "fechaRecibido" => "2005-03-21" "fechaAceptado" => "2005-10-17" "PalabrasClave" => array:2 [ "es" => array:1 [ 0 => array:4 [ "clase" => "keyword" "titulo" => "Palabras clave" "identificador" => "xpalclavsec81370" "palabras" => array:3 [ 0 => "Estapedectomía" 1 => "Ganancia auditiva" 2 => "Prótesis" ] ] ] "en" => array:1 [ 0 => array:4 [ "clase" => "keyword" "titulo" => "Key words" "identificador" => "xpalclavsec81369" "palabras" => array:3 [ 0 => "Stapedectomy" 1 => "Hearing gain" 2 => "Prosthesis" ] ] ] ] "tieneResumen" => true "resumen" => array:2 [ "es" => array:2 [ "titulo" => "Resumen" "resumen" => "<span class="elsevierStyleSectionTitle">Objetivo</span><p id="spar0005" class="elsevierStyleSimplePara elsevierViewall">Determinar los resultados audiológicos, comparando prótesis de teflón (Fluoroplastic) con prótesis tipo pistón de alambre/teflón post-estapedectomía</p> <span class="elsevierStyleSectionTitle">Material y métodos</span><p id="spar0010" class="elsevierStyleSimplePara elsevierViewall">Realizamos un ensayo clínico controlado aleatorizado ciego simple de junio de 2003 a agosto de 2004 en el Servicio de Otorrinolaringología y Cirugía de Cabeza y Cuello, de la Unidad médica de alta especialidad, Hospital General Centro Médico Nacional "La Raza", México D.F. El grupo de estudio se formó con aquellos pacientes en quienes se colocó prótesis de teflón (Fluoroplastic) y el grupo control con prótesis tipo Schucknecht con pistón de alambre/teflón. Se realizó valoración audiológica pre y post-quirúrgica en el servicio de Audiología y Otoneurología del mismo Hospital utilizando un audiómetro marca Madzen Minimate 602, de donde se obtuvo el promedio de la vía aérea en frecuencias bajas, medias, altas, el diferencial aéreo/ósea por frecuencias y total. Los resultados fueron analizados utilizando el paquete estadístico SPSS 8.0</p> <span class="elsevierStyleSectionTitle">Resultados</span><p id="spar0015" class="elsevierStyleSimplePara elsevierViewall">Se estudiaron 138 pacientes: 68 para el grupo de estudio (prótesis de Fluoroplastic) y 70 para el grupo control (prótesis de alambre/teflón); se obtuvo una diferencia estadísticamente significativa entre grupos (p< 0,04) de acuerdo a U de Mann-Whitney. El cierre del diferencial aéreo/ósea, mostró una diferencia estadísticamente significativa (p< 0,001) en frecuencias bajas y altas para el grupo de estudio</p>" ] "en" => array:2 [ "titulo" => "Abstract" "resumen" => "<span class="elsevierStyleSectionTitle">Purpose</span><p id="spar0020" class="elsevierStyleSimplePara elsevierViewall">To compare aTeflon prosthesis to a piston-type wire/Teflon prosthesis assessing auditory results post – Stapedectomy</p> <span class="elsevierStyleSectionTitle">Material and methods</span><p id="spar0025" class="elsevierStyleSimplePara elsevierViewall">We conducted a randomized controlled blinded clinical study from June 2003 to August 2004 at the Otorhinolaryngology, and Head and Neck Surgical Wards at the highly specialized medical unit of “La Raza” General Hospital National Medical Center in Mexico City. The study group was comprised by patients receiving a Teflon prosthesis (Fluoroplastic piston), while the control group received a Schuckneckt type piston wire/Teflonprosthesis. A pre- and post-auditory assessment was done obtaining the average at low, medium and high airway frequencies, the air/bone frequency differences and the total, at the Audiology and Otoneurology Service at the same hospital using a Madzen Minimate 602 brand audiometer. The results were analyzed using SPSS statistical software version 8.0</p> <span class="elsevierStyleSectionTitle">Results</span><p id="spar0030" class="elsevierStyleSimplePara elsevierViewall">138 patients were studied: 68 were included in the study group (Fluoroplastic prosthesis) and 70 in the control group (wire/Teflon prosthesis). A statistically significant difference was found between the groups (p < 0.04) according to the Mann-Whitney U test. The air/bone closure difference was statistically significant (p < 0.001) at low and high frequency ranges for the study group</p>" ] ] "bibliografia" => array:2 [ "titulo" => "Bibliografía" "seccion" => array:1 [ 0 => array:2 [ "identificador" => "bibs0005" "bibliografiaReferencia" => array:10 [ 0 => array:3 [ "identificador" => "bib0005" "etiqueta" => "1." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Thirty years of stapes surgery" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:1 [ 0 => "J.J. Shea" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:5 [ "tituloSerie" => "J Laringol Otol" "fecha" => "1988" "volumen" => "102" "paginaInicial" => "14" "paginaFinal" => "90" ] ] ] ] ] ] 1 => array:3 [ "identificador" => "bib0010" "etiqueta" => "2." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Fenestration of the oval window" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:1 [ 0 => "J.J. Jr. Shea" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:4 [ "tituloSerie" => "Ann Otol Rhinol Laringol" "fecha" => "1958" "volumen" => "67" "paginaInicial" => "932" ] ] ] ] ] ] 2 => array:3 [ "identificador" => "bib0015" "etiqueta" => "3." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Stapedotomy technique and result" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "J.B. Causse" 1 => "J.R. Causse" 2 => "C. Parahy" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:5 [ "tituloSerie" => "Am J Oto" "fecha" => "1985" "volumen" => "6" "paginaInicial" => "68" "paginaFinal" => "70" ] ] ] ] ] ] 3 => array:3 [ "identificador" => "bib0020" "etiqueta" => "4." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Comparison of wire-vein and wire-gelfoam prosthesis in stapedectomy for otosclerosis" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "F.A. Sooy" 1 => "E. Owens" 2 => "E.S. Neufelds" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Ann Otol Rhinol Laryngol" "fecha" => "1973" "volumen" => "82" "paginaInicial" => "149" "paginaFinal" => "152" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/4702350" "web" => "Medline" ] ] ] ] ] ] ] ] 4 => array:3 [ "identificador" => "bib0025" "etiqueta" => "5." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "The necrosed incus in estapedectomy revision" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:1 [ 0 => "A. El Seifi" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Laryngoscope" "fecha" => "1996" "volumen" => "106" "paginaInicial" => "511" "paginaFinal" => "512" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/8614233" "web" => "Medline" ] ] ] ] ] ] ] ] 5 => array:3 [ "identificador" => "bib0030" "etiqueta" => "6." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Revision estapedectomy: intraoperative findings, results, and review of the literature" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:6 [ 0 => "W.W. Han" 1 => "A. Incesulu" 2 => "M.J. Mckenna" 3 => "S.D. Rauch" 4 => "J.B. Nadol" 5 => "R.J. Glynn" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Laryngoscope" "fecha" => "1997" "volumen" => "107" "paginaInicial" => "1185" "paginaFinal" => "1192" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/9292601" "web" => "Medline" ] ] ] ] ] ] ] ] 6 => array:3 [ "identificador" => "bib0035" "etiqueta" => "7." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "A review of 308 cases of revision stapedectomy" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "P.E. Hammerschlag" 1 => "A. Fhisman" 2 => "A.A. Scheer" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Laryngoscope" "fecha" => "1998" "volumen" => "108" "paginaInicial" => "1794" "paginaFinal" => "1800" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/9851493" "web" => "Medline" ] ] ] ] ] ] ] ] 7 => array:3 [ "identificador" => "bib0040" "etiqueta" => "8." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Revision estapedectomy for incus erosion: long-term hearing" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:4 [ 0 => "L.W. Krieger" 1 => "W.H. Lippy" 2 => "A.G. Schuring" 3 => "F.M. Rizer" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Otolaryngol Head Neck Surg" "fecha" => "1998" "volumen" => "119" "paginaInicial" => "370" "paginaFinal" => "373" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/9781993" "web" => "Medline" ] ] ] ] ] ] ] ] 8 => array:3 [ "identificador" => "bib0045" "etiqueta" => "9." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Laser Stapedotomy: A comparative Study of prostheses and seals" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:2 [ 0 => "R. Perkins" 1 => "F.S. Curto" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1288/00005537-199212000-00001" "Revista" => array:6 [ "tituloSerie" => "Laryngoscope" "fecha" => "1992" "volumen" => "102" "paginaInicial" => "1321" "paginaFinal" => "1327" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/1453835" "web" => "Medline" ] ] ] ] ] ] ] ] 9 => array:3 [ "identificador" => "bib0050" "etiqueta" => "10." "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Hearing results in otosclerosis surgery after partial stapedectomy, total stapedectomy and stapedotomy" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "P. Perssom" 1 => "H. Harder" 2 => "B. Magnuson" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:5 [ "tituloSerie" => "Acta Otolaryngol (Stockh)" "fecha" => "1997" "volumen" => "117" "paginaInicial" => "94" "paginaFinal" => "99" ] ] ] ] ] ] ] ] ] ] ] "idiomaDefecto" => "es" "url" => "/00016519/0000005700000001/v1_201304231440/S0001651906786587/v1_201304231440/es/main.assets" "Apartado" => array:4 [ "identificador" => "5888" "tipo" => "SECCION" "es" => array:2 [ "titulo" => "Investigación clínica" "idiomaDefecto" => true ] "idiomaDefecto" => "es" ] "PDF" => "https://static.elsevier.es/multimedia/00016519/0000005700000001/v1_201304231440/S0001651906786587/v1_201304231440/es/main.pdf?idApp=UINPBA00004N&text.app=https://www.elsevier.es/" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0001651906786587?idApp=UINPBA00004N" "pdfAlternativo" => array:1 [ 0 => array:3 [ "idioma" => "en" "documentoPdf" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/file/00016519/addon/S0001651906786587/S300/en/102v57n1a13096849pdf001_2.pdf" "portada" => "102v57n1a13096849pdf001_2.png" ] ] ]
Journal Information
Resultados audiológicos comparando prótesis de teflón versus prótesis alambre/teflón tipo Schucknecht
Auditory results used to compare a Teflon prosthesis vs a Schucknecht type wire/Teflon prosthesis
M. Martín Félix Trujillo
, J. Eduardo Ramírez**
,1
Corresponding author
felixt_mx@yahoo.com.mx
Correspondencia: Flores Magón 209, edificio Aldama, Entrada F, Departamento 221. Col. Tlatelolco, Delegación Cuahutémoc. CP. 06900 México
Correspondencia: Flores Magón 209, edificio Aldama, Entrada F, Departamento 221. Col. Tlatelolco, Delegación Cuahutémoc. CP. 06900 México
* Médico Cirujano Otorrinolaringólogo. Otólogo. Maestro en Ciencias
** Jefe del departamento de Audiología y Otoneurología. Servicio de Otorrinolaringología y Cirugía de Cabeza y Cuello. Unidad Médica de alta especialidad. Hospital General “Dr. Gaudencio González Garza”. Centro Médico Nacional “La Raza”. México D.F