metricas
covid
Buscar en
Actas Urológicas Españolas
Toda la web
Inicio Actas Urológicas Españolas Estudio urodinámico en la evaluación de la incontinencia urinaria femenina, co...
Journal Information
Vol. 32. Issue 3.
Pages 325-331 (January 2008)
Share
Share
Download PDF
More article options
Vol. 32. Issue 3.
Pages 325-331 (January 2008)
Estudio urodinámico en la evaluación de la incontinencia urinaria femenina, con el nuevo sistema MoniTorr MR (urodinamia monocanal con medición de presión de retro-resistencia uretral). Experiencia con 100 pacientes
Urodynamic study in the female urinary incontinence evualuation, with the new monitorrmr system (nonmultichannel urodynamic with urethral retro-resistance pressure measure). experience with 100 patients
Visits
1912
V. Solà Dalenz, P. Ricci Arriola1
Corresponding author
pricci@clinicalascondes.cl
pricci@vtr.net

Correspondencia autor: P. Ricci Arriola Unidad de Uroginecología y Cirugía vaginal. Departamento de Obstetricia y Ginecología. Clínica Las Condes Lo Fontecilla 441, Las Condes. Santiago de Chile. Chile Tel.: (56-2) 210 4000 (56-2) 210 4610
, J. Pardo Schanz
Unidad de Uroginecología y Cirugía Vaginal. Departamento de Obstetricia y Ginecología. Clínica Las Condes. Santiago de Chile. Chile
This item has received
Article information
Resumen
Objetivos

Correlacionar el diagnóstico clínico de la incontinencia urinaria con los resultados de la cistometría (LPP) y URP, obtenidas por medio de urodinamia monocanal. Evaluar la tolerancia de los pacientes a este examen.

Paciente y método

Entre agosto y diciembre del 2006, se realizaron 100 urodinamias monocanal con medición de URP, en las pacientes que consultaron por diagnóstico clínico de incontinencia de orina, en la Unidad de Uroginecología y Cirugía Vaginal, de Clínica Las Condes. Se correlacionó el diagnóstico clínico con los resultados de la urodinamia. Se aplicó una escala de tolerancia subjetiva del examen, donde 0 es la mayor tolerancia y 10 la menor.

Resultados

De las 66 pacientes con clínica de incontinencia de orina de esfuerzo: 10 fueron tipo 0, 2 tipo I, 23 tipo II, 1 tipo III, 17 tipo II+III, 1 detrusor hiperactivo, 5 tipo 0+detrusor hiperactivo, 3 tipo II+detrusor hiperactivo, 4 II+III+detrusor hiperactivo. De las 15 pacientes con IOM: 6 urodinamias fueron tipo 0, 2 tipo II, 2 tipo II+III, 3 detrusor hiperactivo, 1 tipo II+detrusor hiperactivo y 1 tipo III+detrusor hiperactivo. De las 16 pacientes con urgeincontinencia: 2 normal, 4 II+III, 7 detrusor hiperactivo, 1 II+detrusor hiperactivo y 2 II+III+detrusor hiperactivo. En 3 pacientes se solicitó una urodinamia como parte del estudio pre-operatorio, por corresponder respectivamente a dos casos de prolapso de cúpula y un cistocele, todos grado IV (POP-Q), con una gran potencialidad de incontinencia de orina después de la corrección. Presentaron respectivamente una incontinencia de esfuerzo tipo III+detrusor hiperactivo, una tipo II+III y una urodinamia normal. Todas las pacientes identificaron una tolerancia que clasificaron como 2 o 3 (escala de 0 a 10, donde 0 corresponde al grado mayor tolerancia y 10 al grado de menor tolerancia).

Conclusiones

La urodinamia monocanal más la medición de la URP es un examen complementario de gran utilidad en la objetivación y clasificación del diagnóstico de la incontinencia urinaria, sospechada por la clínica. Permite al médico planificar la solución adecuada para cada caso y tiene un alto grado de tolerancia en las pacientes.

Palabras clave:
Urodinamia
Urodinamia Monocanal
URP
Urodinamia Multicanal
Incontinencia de Orina
Incontinencia de orina de esfuerzo
Abstract
Objective

To compare the clinical diagnosis of the urinary incontinence with the results of LPP and URP obtained by non-multichannel urodynamic. To evaluate the tolerance of the patients to this examination.

Pathient and Method

Between August and December 2006, 100 urodynamics were made in patients with clinical diagnosis of urinary incontinence, in the Urogynecology Unit of Clínica Las Condes. The clinical diagnosis was compared with the urodynamic results. A subjective tolerance scale was applied (0 was greater tolerance and 10 was maximum discomfort).

Results

In 66 patients with clinical diagnosis of IUS, the urodynamic registered 10 Type 0, 2 (I), 23 (II), 1 (III), 17 (II+III),1 hyperactive detrusor, 5 (0+ hyperactive detrusor), 3 (II+hyperactive detrusor) and 4 (II+III+hyperactive detrusor). In 15 with Mixed urinary incontinence, the urodynamic showed 6 (Type 0), 2 (II), 2 (II+III), 3 hyperactive detrusor, 1 (II+hyperactive detrusor) and 1 (III+hyperactive detrusor). In 16 patients with urgency incontinence, urodynamic showed 2 normal, 4 (II+III), 7 hyperactive detrusor, 1 (II+hyperactive detrusor) and 2 (II+III+hyperactive detrusor). In 3 patients (two vaginal cuff prolapse and one cistocele, degree IV POP-Q) the urodynamic was indicated in the pre-surgery study considering a great potentially incontinence after correction. Respectively, the patients presented: IUS type III+hyperactive detrusor, IUS type II+III and one normal. All patients expressed 2 and 3 degree tolerance (subjective scale: 1 major tolerance and 10 a minor tolerance).

Conclusions

The MoniTorrMR urodynamic is a complementary examination very useful in the study of the urinary incontinence. It allows planning the solution adapted for each case and has a high degree of tolerance in the patients.

Key words:
Urodinamyc
URP
Multichannel Urodynamic
Urinary Incontinence
Stress urinary incontinence

Article

These are the options to access the full texts of the publication Actas Urológicas Españolas
Subscriber
Subscriber

If you already have your login data, please click here .

If you have forgotten your password you can you can recover it by clicking here and selecting the option “I have forgotten my password”
Subscribe
Subscribe to

Actas Urológicas Españolas

Purchase
Purchase article

Purchasing article the PDF version will be downloaded

Price 19.34 €

Purchase now
Contact
Phone for subscriptions and reporting of errors
From Monday to Friday from 9 a.m. to 6 p.m. (GMT + 1) except for the months of July and August which will be from 9 a.m. to 3 p.m.
Calls from Spain
932 415 960
Calls from outside Spain
+34 932 415 960
E-mail
Article options
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos