Programa Externo de Control de Calidad SEIMC. Año 2007
Pages 8-13 (November 2008)
Programa externo de control de calidad seimc. año 2007
Full text access
Análisis de resultados del Programa Externo de Control de Calidad SEIMC de carga viral del VIH-1 y del VHC. Año 2007
Analysis of the results of the SEIMC External Quality Control Program for HIV-1 and HCV viral loads, 2007
Visits
2027
Nieves Orta Miraa,b, María del Remedio Guna Serranoa,c, José-Carlos Latorre Martínezd, María Rosario Oviesa, José L. Péreza,e,
Corresponding author
jlperez@hsd.es

Correspondencia: Servicio de Microbiología. Hospital Universitario Son Dureta. Andrea Doria, 55. 07014 Palma de Mallorca. España.
, Concepción Gimeno Cardonaa,c,f
a Programa Externo de Control de Calidad SEIMC. Hospital Francesc de Borja. Gandía. Valencia. España
b Servicio de Microbiología. Hospital Francesc de Borja. Gandía. Valencia. España
c Servicio de Microbiología. Hospital General Universitario. Valencia. España
d Servicio de Microbiología. Hospital Clínico Universitario. Valencia. España
e Servicio de Microbiología. Hospital Son Dureta. Palma de Mallorca. España
f Facultad de Medicina. Universidad de Valencia. Valencia. España
This item has received
Article information
Fundamentos

La determinación de la carga viral de los virus de la inmunodeficiencia humana tipo 1 (VIH-1) y de la hepatitis C (VHC) constituye una labor primordial del laboratorio de microbiología molecular, por su valor pronóstico y como guía en el tratamiento. Es crucial que el laboratorio disponga de herramientas para garantizar la fiabilidad de sus resultados. Se presentan el análisis del Programa de Control de Calidad SEIMC de carga viral de ambos virus remitido durante el año 2007.

Métodos y resultados

En el control de VIH se remitieron 5 estándares, de los que uno (plasma humano seronegativo) no contenía el virus, y los otros consistían en plasma de 3 pacientes virémicos distintos en un intervalo de concentraciones de 2-5 log10 copias/ml; 2 de ellos eran idénticos, con el fin de analizar la repetitividad. La especificidad fue buena por todos los métodos comerciales, y sólo 2 de 75 resultados fueron falsos positivos. Una parte importante de los laboratorios obtuvo resultados fuera de límites (media ± 0,2 log10 copias/ml), dependiendo del estándar y del método empleado, en promedio el 20%. Se detectaron errores atribuibles a la transcripción de los resultados analíticos. La repetitividad también fue aceptable, pero en torno al 15% de los laboratorios no superó esta evaluación. En el control de VHC se remitieron 2 estándares con diferente contenido del virus. La mayor parte de los participantes (94,6%) obtuvo resultados dentro de los límites de la media ± 1,96 DE log10 UI/ml, y la variabilidad interlaboratorio fue inferior a 0,5 unidades logarítmicas para ambos estándares y con los distintos métodos.

Conclusiones

Estos resultados refuerzan la utilidad de los controles externos para asegurar la calidad de los resultados analíticos, incluyendo la fase postanalítica. Debido a la notable variabilidad interlaboratorio, es aconsejable utilizar un mismo método y el mismo laboratorio en el seguimiento de los pacientes.

Palabras clave:
VHC
VIH-1
Carga viral
Control de calidad externo
Intercomparación
Background

Human immunodeficiency virus type 1 (HIV-1) and hepatitis C virus (HCV) viral load determinations are among the most important tasks performed in the molecular microbiology laboratory, due to their importance in patient follow-up. Quality control tools are crucial in these laboratories to ensure the accuracy of the results. This article presents the analysis of the results obtained in 2007 from the SEIMC External Quality Control Program for HIV-1 and HCV viral loads.

Methods and results

In the HIV-1 program, a total of five standards were sent. One standard consisted of seronegative human plasma, while the remaining four contained plasma from three different viremic patients, in a range of 2-5 log10 copies/mL; to analyze repeatability, two of these standards were identical. The specificity was good for all the methods used by the participants, and only two out of 75 results were considered to be false positive results. A substantial proportion of the laboratories (20% on average) obtained values outside the accepted range (mean ±0.2 log10 copies/mL), depending on the standard and on the method used for quantification. A few errors were due to the transcription of the analytical result. Repeatability was also acceptable but approximately 15% of laboratories failed this evaluation. The HCV program consisted of two standards with different viral load contents. Most of the participants (94.6%) obtained results within the accepted range (mean ±1.96 SD log10 UI/mL), and interlaboratory variability was <0.5 log units for both standards and all techniques.

Conclusions

Data from this analysis reinforce the utility of proficiency programs to ensure the quality of the results obtained by a particular laboratory, as well as the importance of the post-analytical phase in overall quality. Due to wide interlaboratory variability, the use of the same method and the same laboratory for patient follow-up is advisable.

Key words:
HCV
HIV-1
Viral load
External Quality Control
Proficiency
Full text is only aviable in PDF
Bibliografía
[1.]
P.R. Bevington, D.K. Robinson.
Data reduction and error analysis for the physical sciences.
3rd ed., McGraw-Hill, (2003),
[2.]
Niesters HGM. QCMD 2005 human immunodeficiency virus type 1 (HIVRNA05) proficiency programme. Final report. Glasgow: Quality Control for Molecular Diagnostics, 2005. Disponible en: www.qcmd.org
[3.]
N. Orta, M.R. Guna, J.C. Latorre, J.L. Pérez, C. Gimeno.
Análisis de resultados del Programa de Control de Calidad Externo de Carga Viral del VIH-1 y del VHC, año 2006.
Enferm Infecc Microbiol Clin, 25 (2007), pp. 8-13
[4.]
Programa Nacional de Control de Calidad de Carga Viral del VIH. Versión Anual. 7.ª ed. Madrid: Ministerio de Sanidad y Consumo. Secretaría del Plan Nacional sobre el SIDA; 2005.
[5.]
S.J. Best, A.P. Gust, E.J.M. Johnson, C.H. McGavin, E.M. Dax.
Quality of human virus viral load testing in Australia.
J Clin Microbiol, 38 (2000), pp. 4015-4020
[6.]
D.J. Brambilla, S. Granger, C. Jennings, J.W. Bremer.
Multisite comparison of reproducibility and recovery from the standard and ultrasensitive Roche Amplicor HIV Monitor assays.
J Clin Microbiol, 29 (2001), pp. 1221-1223
[7.]
G. Muyldermans, L. Debaisieux, K. Fransen, D. Marissens, K. Miller, D. Vaira, et al.
Blinded, multicenter quality control study for the quantification of human immunodeficiency virus type 1 RNA in plasma by the Belgian AIDS reference laboratories.
Clin Microbiol Infect, 6 (2000), pp. 213-217
[8.]
Niesters HGM. QCMD 2005 hepatitis C virus (HCVRNA05) proficiency programme. Final report. Glasgow: Quality Control for Molecular Diagnostics, 2005. Disponible en: www.qcmd.org
[9.]
G. Gentili, K. Cristiano, G. Pisani, G.M. Bisso, M. Miceli, M. Wirz, et al.
Collaborative study for the calibration of a new Italian HCV RNA reference preparation against the international standard.
Ann Ist Super Sanità, 39 (2003), pp. 183-187
[10.]
L. Fanning, E. Kenny-Walsh, J. Levis, K.R. Choudhury, B. Cannon, M. Sheehan, et al.
Natural fluctuations of hepatitis C virus load in a homogeneous patient population: a prospective study.
Hepatology, 35 (2000), pp. 225-229
[11.]
E. Martínez-Bauer, J. Crespo, M. Romero-Gómez, R. Moreno-Otero, R. Sola, N. Tesei, et al.
Development and validation of two models for early prediction of response to therapy in genotype 1 chronic hepatitis C.
Hepatology, 43 (2006), pp. 72-80
Copyright © 2008. Elsevier España S.L.. Todos los derechos reservados
Download PDF
Article options
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos