Drawing blood samples through a central venous catheter (CVC) is a customary practice in Intensive Care Units (ICUs). It is indicated to discard a volume of waste blood to avoid interference in the results.
AimTo determine whether a lower discard volume for obtaining blood samples from temporary CVCs placed into the internal jugular, femoral or subclavian vein offers valid results.
MethodA quasi-experimental prospective cross-sectional study for which sixty-five patients of over 18 years of age in ICUs, who had been fitted with a triple lumen central venous catheter, were recruited over a period of eight months. Two consecutive blood samples were extracted with tubes for biochemistry, coagulation and hemogram from each patient from the distal lumen. The first sample was obtained with a discarded waste of 1.5 ml from a total extracted volume of 10.2 ml, similar to the usual waste in our ambit (10 ml). Subsequently the second sample was obtained. The paired t-test was used to analyse the data. The Bland-Altman plot and intraclass correlation coefficient (ICC) were used to measure the agreement between methods. The reference change value (RCV) was established as the admissible limit of variation between the pairs of samples.
ResultsA total of 65 sample pairs were drawn (intervention-control). The paired t-test found statistically significant differences with a significance level of α = .05 for chlorine (−.536; .012); prothrombin time (−.092; .019) and prothrombin activity (.284; 1.375).The ICC was greater than .9 in all the variables and the limit determined for the RCV was not surpassed by any value.
ConclusionsThe results show the reliability of the blood samples drawn with a discard volume of 1.5 ml.
La extracción de muestras sanguíneas a través de un catéter venoso central (CVC) es una práctica habitual en las Unidades de Cuidados Intensivos (UCI). Está indicado desechar un volumen de sangre, denominado volumen de descarte, con la finalidad de evitar que los resultados puedan verse alterados.
ObjetivosDeterminar si un menor volumen de descarte para la obtención de analíticas procedentes de CVC temporales alojados en la vena yugular interna, femoral o subclavia ofrece resultados válidos.
MétodoEstudio cuasiexperimental, prospectivo, transversal donde se reclutaron 65 pacientes críticos mayores de 18 años portadores de CVC temporal de tres luces durante un período de ocho meses. Se extrajeron dos analíticas consecutivas en cada paciente de la luz distal con los valores de hemograma, bioquímica y coagulación comúnmente analizados en paciente crítico. Se obtuvieron dos muestras consecutivas; la primera con un descarte de 1,5 ml y un volumen extraído total de 10,2 ml y seguidamente se obtuvo la segunda muestra. Para el análisis de datos se utilizó la pruebat pareada; para medir la concordancia entre métodos, la representación de Bland-Altman y el Coeficiente de Correlación Intraclase (CCI). Se estableció el Valor de Referencia del Cambio (VRC) como límite admisible de variación entre los pares de muestras.
ResultadosSe extrajeron un total de 65 pares de muestras (intervención-control). El contraste de medias encontró diferencias estadísticamente significativas con α = 0,05 para cloro (−0,536; 0,012); tiempo de protombina (−0,092; 0,019) y actividad de protombina (0,284; 1,375). El CCI resultó mayor a 0,9 en todas las variables y el VRC no fue superado por ningún valor.
ConclusionesLos resultados muestran la validez de los análisis de las muestras de sangre extraídas con un volumen de descarte de 1,5 ml.