covid
Buscar en
Progresos de Obstetricia y Ginecología
Toda la web
Inicio Progresos de Obstetricia y Ginecología Ritmo cardíaco materno imitando el ritmo cardíaco fetal en un caso de muerte f...
Journal Information
Vol. 46. Issue 11.
Pages 520-522 (January 2003)
Share
Share
Download PDF
More article options
Vol. 46. Issue 11.
Pages 520-522 (January 2003)
Full text access
Ritmo cardíaco materno imitando el ritmo cardíaco fetal en un caso de muerte fetal
Maternal heart rate mimicking fetal heart rate in a case of fetal death
Visits
6976
C. Bedoya
Corresponding author
carbed@supercable.es

Correspondencia: Avda. Blas Infante 8-A, piso 4.°, puerta 4.a. 41011 Sevilla. España
, N. Gaitan
Servicio de Obstetricia y Ginecología. Hospital Universitario Virgen Macarena. Sevilla. España
This item has received
Article information
Resumen

Un ritmo cardíaco materno fue erróneamente interpretado intraparto como un ritmo cardíaco fetal. El modelo del ritmo del corazón materno tenía una línea basal de 120 lat/min, variabilidad normal de las oscilaciones y aceleraciones con las contracciones uterinas. A las 2 h de comenzado el registro de la frecuencia cardíaca en un control ultrasonográfico se evidenció la ausencia de latidos cardíacos fetales. Inmediatamente después se recogió el mismo modelo de frecuencia cardíaca materna que nos había confundido. Horas más tarde nació por vía vaginal un feto muerto sin signos de maceración.

Palabras clave:
Muerte fetal intraparto
Ritmo cardíaco materno
Ritmo cardíaco fetal
Summary

A maternal heart rate was erroneously interpreted intrapartum as the fetal heart rate. The maternal heart rate pattern had a baseline of 120 beats per minute, normal variability and accelerations with maternal uterine contractions. After two hours of recording, ultrasonography showed the absence of fetal heart beats. Immediately afterwards, the same pattern of maternal heart rate was registered simulating a fetal heart rate. Some hours later the patient vaginally delivered a stillborn fetus without signs of maceration.

Keywords:
Intrapartum fetal death
Maternal heart rate
Fetal heart rate
Full text is only aviable in PDF
Bibliografía
[1.]
B.S. Schifrin, R. Harwell, T. Rubinstein, G.H.A. Visser.
Maternal heart rate pattern: a confounding factor in intrapartum fetal surveillance.
Prenat Neonat Med, 6 (2001), pp. 75-82
[2.]
P.S. Ramsey, B.W. Johnston, V.E. Welter, P.L Ogburn Jr..
Artifactual fetal electrocardiographic detection using internal monitoring following intrapartum fetal demise during VBAC trial.
[3.]
D.J. Sherman, E. Frenkel, Y. Kurzweil, A. Padua, S. Arieli, M. Bahar.
Characteristics of maternal heart rate patterns during labor and delivery.
Obstet Gynecol, 99 (2002), pp. 542-547
[4.]
N.A. McWhinney, S. Knowles, H.L. Green, H. Gordon.
Transmission of the maternal electrocardiograph via a fetal scalp electrode in the presence of intrauterine death. Case report.
Br J Obstet Gynecol, 91 (1984), pp. 1046-1048
Copyright © 2003. Sociedad Española de Ginecología y Obstetricia
Download PDF
Article options
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos