Original
Open Access
Twelve-month follow-up of complex patients treated with the Xience VTM everolimus drug-eluting stents in daily practice – results of the BRAVO Brazilian Registry
Seguimento de 12 meses de pacientes complexos tratados com stents farmacológicos liberadores de everolimus XIENCE V® na prática diária – resultados do registro brasileiro BRAVO
Visitas
2398
BRAVO study investigators
,1
Este artículo ha recibido

Under a Creative Commons license
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Tablas (5)
Table 1. Baseline clinical and angiographic characteristics.
Table 2. Cumulative rates of adverse events up to 12 months of follow-up (n = 535).
Table 3. Description of stent thrombosis cases reported up to 12 months of follow-up (organized by the time up to the event from the index procedure).
Table 4. Description of major bleeding cases according tothe TIMI17 criterion up to 12 months of follow-up (organized by time up to the event from the index procedure).
Table 5. Comparison of clinical studies with XIENCE VTM Everolimus-eluting stent.
Mostrar másMostrar menos
Abstract
Background

The Xience VTM everolimus-eluting stent is a new generation drug-eluting stent (DES) that incorporates a low profile cobalt-chromium platform (81μm) and a highly biocompatible polymer (fluoropolymer), which carries and controls the release of everolimus. Recent studies have demonstrated sustained safety and efficacy of the Xience VTM in the treatment of real-world populations. Our aim was to report the clinical results of 12 months of the BRAVO Brazilian protocol.

Methods

The BRAVO Registry was a prospective, non-randomized, single-arm, multicenter (25 centers) study that evaluated the late clinical results of 535 minimally selected patients treated with the drug- eluting stent Xience VTM in Brazilian daily practice.

Results

Overall, 40% of patients had diabetes, 25% prior myocardial infarction, and 42% presented with acute coronary artery syndrome. The majority of lesions (69%) was highly complex (ACC/AHA type B2 or C). The mean length and the nominal stent diameter were 19.9 ± 5.3mm and 3.0 ± 0.4mm, respectively. The angiographic and procedural successes were 99.7 and 98%, respectively. At 12 months, the cumulative rate of major adverse cardiac events, available in 100% of patients, was 5.6% (cardiac death: 1.3%; acute myocardial infarction: 3.0%; revascularization of the target lesion: 2.2%). Stent thrombosis occurred in 5 patients (0,9%), and only 1 case was reported between 6 and 12 months.

Conclusions

The drug-eluting stent Xience VTM demonstrated sustained safety and efficacy up to 12 months in the treatment of complex coronary lesions in patients from daily practice.

Keywords:
Coronary disease
Percutaneous coronary intervention
Drug-eluting stents
Resumo
Introdução

O stent liberador de everolimus XIENCE V® é um stent farmacológico de nova geração que incorpora uma plataforma de cromo-cobalto de baixo perfil (81μm) e um polímero de elevada biocompatibilidade (fluoropolímero), o qual carreia e controla a liberação do fármaco everolimus. Estudos recentes demonstram segurança e eficácia sustentadas do dispositivo XIENCE V® no tratamento de populações da prática clínica. Nosso objetivo foi reportar resultados clínicos de 12 meses do protocolo brasileiro BRAVO.

Métodos

O registro BRAVO foi um estudo prospectivo, não randomizado, de braço único, multicêntrico (25 centros), que avaliou os resultados clínicos tardios de 535 pacientes minimamente selecionados, tratados com o stent farmacológico XIENCE V®.

Resultados

Cerca de 40% dos pacientes tinham diabetes, 25% infarto agudo do miocárdio prévio e 42% apresentaram-se com síndrome coronária aguda. A maioria das lesões (69%) era de elevada complexidade (ACC/AHA tipo B2/C). As médias da extensão e do diâmetro nominais dos stents foram, respectivamente, 19,9 ± 5,3mm e 3,0 ± 0,4mm. Os sucessos angiográfico e de procedimento foram de 99,7% e 98%, respectivamente. Aos 12 meses, a taxa cumulativa de eventos cardíacos adversos maiores, disponível em 100% dos pacientes, foi de 5,6% (morte cardíaca: 1,3%; infarto agudo do miocárdio: 3,0%; revascularização da lesão-alvo: 2,2%). Já a trombose de stent ocorreu em cinco pacientes (0,9%), sendo reportada apenas uma ocorrência entre 6 e 12 meses.

Conclusões

O stent farmacológico XIENCE V® demonstrou segurança e eficácia sustentadas ao final de 12 meses no tratamento de lesões coronárias complexas em pacientes da prática diária.

Palavras-chave:
Doença das coronárias
Intervenção coronária percutânea
Stents farmacológicos
Texto completo
Introduction

In general, the new generation of drug-eluting stents (DES) has shown high efficacy and safety in the treatment of patients with coronary lesions in daily practice.1–3 Compared with older DES,4,5 these devices are characterized by the presence of smaller profile metallic components, drug carrier systems with optimized biocompatibility and potent antiproliferative agents.6–13The XIENCE VTM stent (Abbott Vascular, Santa Clara, USA) incorporates an 81μm thick cobalt-chromium platform with a non-thrombogenic polymer (fluoropolymer), which carries and controls the everolimus release.6 Recent studies with the XIENCE VTM stent, including real-world populations, have shown low occurrence of major adverse cardiac events (MACE) and late and very late stent thrombosis.14–19Specifically in the 6 month follow-up of BRAVO registry (BRazil XIENCE VTM Everolimus-Eluting Coronary Stent System “Real-World” Outcomes Registry), which evaluated 535 patients, the cumulative rates of MACE (4.3%), cardiac death (1.1%) and stent thrombosis (0.8%) were relatively low, especially considering a complex Brazilian cohort treated at multiple centers in daily practice.20 However, long-term follow-up data are still needed to better assess the impact of this device in our population. Thus, our objective was to report the clinical results of the 12 month follow-up of patients included in the BRAVO protocol.

MethodsProtocol and procedure

The protocol details and the initial results of the BRAVO registry had been previously reported.20 In short, this was a prospective, non-randomized, single-arm, multicenter (25 centers), national, post-marketing clinical trial, which used a validated electronic data capture system, independently managed by a Representative Organization of Clinical Research in São Paulo (SP). The objective of the study was to assess the late clinical outcomes in minimally selected patients (exclusion: saphenous graft and life expectancy < 24 months) undergoing percutaneous coronary intervention (PCI) with XIENCE VTM DES in Brazilian daily practice. Patients with at least one lesion with stenosis ≥ 50%, located in a native coronary artery with favorable anatomy for PCI with stenting were included. In general, PCI procedures were performed according to current guidelines,21 and the final strategy was left to the operator's discretion. The available stents had the following measurements: 2.5, 3.0 and 3.5mm in diameter, and 8, 12, 15, 18, 23 and 28mm in length. In relation to dual antiplatelet therapy (DAPT) recommendations after the procedure, aspirin was prescribed indefinitely and thienopyridine (clopidogrel) was prescribed for at least 12 months.

Clinical outcomes and definitions

The primary study outcome was the occurrence of MACE in the 12 months of follow-up. The considered late clinical outcomes included target-lesion revascularization (TLR) at 6 and 12 months, stent thrombosis and major bleeding up to 12 months. The composite MACE outcome was defined as cardiac death, acute myocardial infarction (AMI) and TLR. Target-vessel revascularization (TVR) included cases of TLR.

Stent thrombosis was defined according to the criteria of the Academic Research Consortium (ARC).22 Major bleeding followed the Thrombolysis in Myocardial Infarction (TIMI) criteria, including intracranial hemorrhage or absolute decrease ≥ 5g/dL in hemoglobin concentrations or absolute decrease ≥ 15% in hematocrit levels.23

Clinical follow-up was scheduled at 30 days, 6, 12 and 24 months post-procedure and consisted of medical consultations or telephone contact carried out according to a predefined protocol. A total of 535 patients were enrolled between September 2008 and September 2010, and all (100%) completed the follow-up at 12 months.

All adverse events had their information directly verified in the source documentation and were later adjudicated by an independent Clinical Events Committee, which included three experienced professionals from the Clinical and Invasive Cardiology areas. For the current analysis, clinical results were reported up to 12 months.

Statistical analysis

Categorical variables are shown as frequencies and percentages. Quantitative variables are shown as mean and standard deviation.

ResultsBaseline and procedure characteristics

The baseline clinical and angiographic characteristics are shown in Table 1. Overall, 40% of patients had diabetes, 25% had a previous AMI, and 42% had acute coronary syndrome (ACS), including 29% with unstable angina, 9% with AMI without ST-segment elevation, and 4% with AMI with ST-segment elevation. Regarding the PCI procedure, 14% received multiple stents, 42% had post-dilation with balloon catheter and the mean nominal length and nominal diameter of the stents were, respectively, 19.9 ± 5.3mm and 3.0 ± 0.4mm. At the end of the procedure, the angiographic and procedure success were 99.7% and 98%, respectively.

Table 1.

Baseline clinical and angiographic characteristics.

Variable  n = 535 (770 lesions) 
Age, years  62.7 ± 11.1 
Female gender, n (%)  171 (32.0) 
Diabetes mellitus, n (%)  214 (40.0) 
Using insulin  60 (11.2) 
Hypertension, n (%)  433 (80.9) 
Dyslipidemia, n (%)  407 (76.1) 
Smoking history, n (%)  234 (43.7) 
Current smoking  101 (18.9) 
Family history of CAD, n (%)  265 (49.5) 
Previous myocardial infarction n (%)  133 (24.9) 
Previous PCI, n (%)  206 (38.5) 
Previous CABG, n (%)  54 (10.1) 
Previous stroke, n (%)  21 (3.9) 
CHF functional class III or IVa, n (%)  39 (7.3) 
Renal failureb, n (%)  33 (6.2) 
Peripheral vascular disease, n (%)  25 (4.7) 
Clinical presentation of ACS, n (%)  224 (41.9) 
Target vessel, n (%)   
Left anterior descending artery  335 (46.1) 
Left circumflex artery  181 (23.5) 
Right coronary artery  213 (27.7) 
Left main coronary artery  21 (2.7) 
Bifurcation, n (%)  89 (11.6) 
Total occlusion, n (%)  48 (6.2) 
In-stent restenosis, n (%)  54 (7.0) 
Type B2/C lesionc, n (%)  531 (69.0) 
Lesion length, mm  17.8 ± 7.3d 
Reference vessel diameter, mm  3.0 ± 1.4d 
Stenosis diameter, %  82.9 ± 10.1d 

CAD: coronary artery disease; PCI: percutaneous coronary intervention; CABG: coronary artery bypass graft; CHF: congestive heart failure; ACS: acute coronary syndrome.

a According to the New York Heart Association classification.

b Defined by the measurement of baseline serum creatinine ≥ 1.5mg/dL.

c According to the modified classification of the American College of Cardiology/American Heart Association.

d Estimated by visual analysis, as reported by the operator.

Clinical events

Table 2 shows the cumulative rates of adverse events up to 12 months of clinical follow-up. Between 6 and 12 months, there were seven new cases of MACE, including two cardiac deaths. In the first case, a 53 year-old patient with multiple risk factors (systemic arterial hypertension – SAH, diabetes, dyslipidemia, smoking, acute myocardial infarction and previous coronary artery bypass graft – CABG), had initially two lesions treated in the right coronary artery in the presence of ACS, but developed inferior AMI with ST-segment elevation followed by death 245 days after the procedure. In the second case, a 70 year-old female, with a history of SAH, dyslipidemia and diabetes, had the left anterior descending artery treated in the index procedure due to the clinical picture of stable angina functional class III; however, she showed recurrence of the lesion in the treated vessel and progression of atherosclerotic disease, being submitted to CABG; she developed postoperative complications and died on the day 289. Additionally, three patients had non-cardiac death due to the development of pancreatic cancer (day 246), multiple trauma (day 280) and respiratory failure (day 295).

Table 2.

Cumulative rates of adverse events up to 12 months of follow-up (n = 535).

Event  Hospital  30 days  6 months  12 months 
MACE, n (%)  10 (1.9)  13 (2.4)  23 (4.3)  30 (5.6) 
Cardiac death, n (%)  0 (0)  2 (0.4)  5 (0.9)  7 (1.3) 
MI, n (%)  10 (1.9)  10 (1.9)  12 (2.2)  16 (3.0) 
TLR, n (%)  0 (0)  1 (0.2)  5 (0.9)  12 (2.2) 
TVR, n (%)  0 (0)  2 (0.4)  7 (1.3)  15 (2.8) 
ST, n (%)  1 (0.2)  2 (0.4)  4 (0.8)  5 (0.9) 
Definitive 
Probable 
Possible 

MACE: major adverse cardiac events; MI: myocardial infarction; TLR: target lesion revascularization; TVR: target vessel revascularization; ST: stent thrombosis.

The cumulative rate of any stent thrombosis reported up to 12 months was 0.9%, totaling five cases; the rate of definitive/probable stent thrombosis was 0.6% (three cases). The detailed description of the cases is shown in Table 3. Finally, cases of major bleeding according to the TIMI criteria were reported in three patients up to 12 months of follow-up and, in one case, the patient had two distinct episodes of gastrointestinal bleeding (Table 4).

Table 3.

Description of stent thrombosis cases reported up to 12 months of follow-up (organized by the time up to the event from the index procedure).

Case  Age (years)  Gender  Previous history  Indication  Target vessel  Event presentation  Use of DAPT  Days until the event  Adjudication (ARC criterion)22 
52  SAH, dyslipidemia, smoking, PVD, previous MI, previous PCI  ACS  LAD/Dg (bifurcation)  Unstable angina  Yes  Definite ST (acute) 
75  DM, SAH, dyslipidemia  Silent ischemia  Dg (1st branch)  Sudden death  Yes  28  Probable ST (subacute) 
80  SAH, dyslipidemia, smoking, CHF, permanent pacemaker  UA class II  RCA  Sudden death  Yes  42  Possible ST (late) 
77  DM, SAH, dyslipidemia, dialytic CRF  ACS  LAD (2 lesions)  Sudden death  Yes  154  Possible ST (late) 
53  DM, SAH, dyslipidemia, smoking, previous MI, previous CABG  ACS  RCA (2 lesions)  AMI with ST elevation  Yes  245  Definitive ST (late) 

DAPT: dual antiplatelet therapy; ARC: Academic Research Consortium; M: male; SAH: systemic arterial hypertension; PVD: peripheral vascular disease; AMI: acute myocardial infarction; PCI: percutaneous coronary intervention; ACS: acute coronary syndrome; LAD: left anterior descending artery; Dg: diagonal branch: ST: stent thrombosis; F: female; DM: diabetes mellitus; CHF: congestive heart failure; SA: stable angina; RCA: right coronary artery; CRF: chronic renal failure; CABG: coronary artery bypass graft surgery.

Table 4.

Description of major bleeding cases according tothe TIMI17 criterion up to 12 months of follow-up (organized by time up to the event from the index procedure).

Case  Age (years)  Gender  History  Indication  Target Vessel  Event presentation  Use of DAPT  Days until the event  Treatment/ Evolution 
75  DM, SAH, dyslipidemia, CRF  ACS  RCA, LCx  Gastrointestinal bleedinga  Yes  12  Packed red blood cell transfusion 
            Gastrointestinal bleedinga,b  Yes  75  Packed red blood cell transfusion 
70  SAH, dyslipidemia, smoking, CHF, definitive pacemaker, gastrointestinal bleeding  SA class II  RCA  Rectal bleeding  Yes  20  Death (non-cardiac) 
87  SAH, dyslipidemia  ACS  LMCA, LAD, LCx  Hemorrhagic stroke  Yes  153  Death (non-cardiac) 

DAPT: dual antiplatelet therapy; M: male; DM: diabetes mellitus; SAH: Systemic arterial hypertension; CRF: chronic renal failure; ACS: acute coronary syndrome; RCA: right coronary artery; LCx: left circumflex artery; CHF: congestive heart failure; SA: stable angina; LMCA: left main coronary artery; LAD: left anterior descending artery.

a Event associated with the decrease in serum hemoglobin levels ≥ 5g/dL.

b Second bleeding event in the same patient (case 1).

Discussion

In general, the clinical results at 12 months in the current analysis, which involved a relatively large number of minimally selected patients (n = 535) obtained from the national daily practice, confirmed the safety and efficacy profile previously observed in our registry at 6 months.20 They were also comparable to a series of reported studies with the XIENCE VTM device in real-world populations, which showed high rates of procedure success (96% to 99%), as well as clinical safety and effectiveness that persisted during the late and very late follow-up (Table 5).14–19 These findings unequivocally suggest a very favorable performance of this second-generation everolimus-eluting DES in different clinical settings, including high-risk subgroups.

Table 5.

Comparison of clinical studies with XIENCE VTM Everolimus-eluting stent.

Study  BRAVO  COMPARE14  RESET15  EXCELLENT16  SPIRIT III17  SPIRIT IV18  TWENTE19 
Patients, n  535  897  1,597  1,079  669  2,458  694 
Lesions, n  770  1,286  1,967  1,459  772  3,142  1,036 
Diabetics, %  40  17  45  37  30  32  21 
ACS, %  42  60  18  53  19  28  51 
LAD, %  46  40  49  50  41  41  42 
Bifurcation, %  12  17  39  11  ND  ND  25 
B2/C lesion, %  69  74  ND  53  ND  ND  70 
Lesion length, mm  17.8  16.8  17.0  20.31  14.7  14.8  14.30 
RVD, mm  3.0  2.56  2.58  2.87  2.77  2.75  2.66 
Procedure success, %  98  98  97.8  99  NA  NA  95.8 
Follow-up at 12 months, %  100  100  98  98.9  97.9  98.3  99.7 
MACE, %  5.6  6.2  3.8  4.2 
Cardiac death, %  1.3  0.3  0.8  0.4  1.4 
MI, %  1.4  2.8  1.9  4.6 
TLR, %  2.2  4.3  2.4  3.4  2.5  1.4 
TVR, %  2.8  6.9  3.1  6.1  3.9  NA 
ST (definitive/probable), %  0.6  0.7  0.4  0.4  1.1  0.3  1.2 

ACS: acute coronary syndrome; LAD: left anterior descending artery; NA: not available; RVD: reference vessel diameter; MACE: major adverse cardiac events; MI: myocardial infarction; TLR: target lesion revascularization; TVR: target vessel revascularization; ST: stent thrombosis.

In the BRAVO registry, the MACE rate at 6 months was 4.3%20; however, there were seven new occurrences of this outcome between 6 and 12 months, representing a small increase (approximately 1.3%) during the period. It is noteworthy the fact that the new revascularization, due to the late stenosis recurrence or disease progression, was the main determining factor in six of seven new reported cases. In the era of balloon angioplasty, the main late recurrence mechanism seemed to be vascular remodeling or recoil, with the binary angiographic restenosis occurring in up to 50% of the cases. Regarding the cases of post-bare metal stent recurrence, they have been associated mainly with neointimal hyperplasia, with rates ranging between 20% and 30%.4,5,24,25

It was noteworthy that, in both situations, the incidence peak seemed to occur at the similar time, between 3 and 6 months.26 However, with the DES, the formation of neointimal tissue is significantly inhibited – binary angiographic restenosis usually < 10% and such process is also delayed due to the local action of the antiproliferative drug.1,4–12,27 Therefore, albeit unlikely, cases of recurrence may occur at a later stage (> 6 months) in comparison with bare-metal stents (≤ 6 months). However, the predictors classically associated with post-PCI restenosis (diabetes, long lesions, small-caliber vessels, complex lesions, etc.) remain the same.28,29

Interestingly, in addition to neointimal hyperplasia, recent studies have demonstrated a new post-stent recurrence mechanism, including the neoatherosclerosis process, which can occur even in the presence of second-generation DES.30,31 Serial analyses of quantitative coronary angiography in the SPIRIT II and III studies showed relatively low rates of binary angiographic restenosis in the segment treated with XIENCE VTM stent (3.4 to 4.7% at 6 and 8 months, respectively), which were associated with TLR rates of 1.8% at 6 months (SPIRIT II) and 3.4% at 12 months (SPIRIT III).17,18 Similarly, clinical restenosis rates in the BRAVO registry were 0.9% at 6 months and 2.2% at 12 months, despite the high prevalence of diabetes, ACS and complex lesions. These findings demonstrate the clinical effectiveness of the second-generation DES, especially of the everolimus-releasing system, even in more complex populations (Table 5).

Despite the remarkable efficacy in reducing neointimal hyperplasia, restenosis, and thus the need for new revascularization demonstrated by the first-generation DES vs. bare-metal stents,4,5 safety-related concerns, particularly in late and very late stages,3 eventually prompted the research and development of new DES systems, aiming at a better safety profile. A series of studies showed, quite clearly, the multifactorial profile associated with the genesis of thrombosis post-DES implantation.3,32,33 Of note, among others, are the characteristics associated with: comorbidities and clinical presentation (diabetes, renal failure, ACS, etc.); lesion morphology and procedure (complex lesions, bifurcation, thrombus, multivessel PCI, stent underexpansion, dissection, etc.); DAPT interruption (mainly in the first 6 months); and stent type.

Nevertheless, even considering the current evidence, it is not completely determined to which extent (or to what degree) one or another of these characteristics, or a combination of them, may influence and/or predict the occurrence of stent thrombosis. Regarding DES, strut thickness, biocompatibility of the carrier systems and the action mechanism of the antiproliferative drug have been considered decisive components for performance and safety profile, both early and late/very late. Among the most used second-generation DES, the thin chrome-cobalt and platinum-cobalt metallic platforms (74-91 microns) are commonly found.6,9,10,13 In relation to the carrier systems, they incorporate “non-thrombogenic” or biodegradable polymers with a better biocompatibility profile, when compared to those durable polymers used in older DES.6–13,34

Finally, drugs from the “limus” family currently prevail.6–13 Three randomized trials comparing the XIENCE VTM stent vs. Taxus™ paclitaxel-eluting stent (Boston Scientific, Natick, USA) showed lower rates of MACE and stent thrombosis with the first one in the 12 months of follow-up.14,17,18 Three other randomized studies showed non-inferiority of everolimus-releasing DES vs. CYPHERTM sirolimus-releasing stent (Cordis Corp., Warren, USA) regarding the clinical outcomes at 12 or 18 months of follow-up;15,16,35 however, very late stent thrombosis rate (> 1 year) seems to be lower with the everolimus-releasing system.3

Stent thrombosis rates reported up to 1 year with the XIENCE VTM stent ranged from 0.4% to 1.2%. In our population, this rate (definite/probable) was 0.6%, despite the high prevalence of diabetic patients (40%), ACS (42%) and complex lesions (69% B2/C type). Considering only the late (between 1 and 12 months) stent thrombosis (definite/probable), the rate was extremely low (0.2%), representing only one occurrence.

It is noteworthy the fact that most patients that had any stent thrombosis (n = 5) had multiple clinical comorbidities and ACS in the index procedure, although they were being treated with DAPT at the time of the thrombotic event. Nonetheless, the evaluation of event incidence in the very late clinical follow-up (not yet reported) is required, so the sustainability of these results can be verified.

Conclusions

Results of the late clinical follow-up of the BRAVO Brazilian multicenter registry showed sustained safety and efficacy of the XIENCE VTM everolimus-eluting stent in the treatment of complex coronary lesions in minimally selected patients from the national daily practice, including relatively low stent thrombosis (< 1%) and target-lesion revascularization rates (2.2%) after 12 months.

Funding sources

None declared.

Conflicts of interest

The authors declare no conflicts of interest.

Acknowledgements

The following investigators are part of the BRAVO study: Alexandre Abizaid Instituto Dante Pazzanese de Cardiologia, São Paulo (SP), Brazil; Amanda G. M. R. Sousa Instituto Dante Pazzanese de Cardiologia, São Paulo (SP), Brazil; Andrea S. Abizaid Instituto Dante Pazzanese de Cardiologia, São Paulo (SP), Brazil; Antônio C. N. Ferreira Hospital Mater Dei S.A., Belo Horizonte, MG, Brazil; Ari Mandil Hospital Lifecenter, Belo Horizonte, MG, Brazil; César R. Medeiros Hospital Rede D’Or, Unidades Copa, Barra e Quinta D’Or, Rio de Janeiro, RJ, Brazil; Costantino R. Costantini Hospital Cardiológico Costantini, Curitiba, PR, Brazil; Décio Salvadori Hospital Beneficência Portuguesa, São Paulo (SP), Brazil; Erlon O. de Abreu-Silva Cardiovascular Research Center, São Paulo (SP), Brazil; Flávio R. A. Oliveira Maximagem Diagnóstico por Imagem Ltda., Recife, PE, Brazil; Gilberto Nunes Santa Casa de Misericórdia, Porto Alegre, RS, Brazil; Hélio Castello Jr. Hospital Bandeirantes, São Paulo (SP), Brazil; Heloísa M. S. Guimarães Centro Integrado de Medicina Intervencionista, Belém, PA, Brazil; José Airton Arruda CIAS Unimed, Vitória, ES, Brazil; José Armando Mangione Hospital Beneficência Portuguesa, São Paulo (SP), Brazil; José Eduardo Sousa Instituto Dante Pazzanese de Cardiologia, São Paulo (SP), Brazil; Juliana P. de Castro Cardiovascular Research Center, São Paulo (SP), Brazil; Luiz A. Mattos Instituto Dante Pazzanese de Cardiologia, São Paulo (SP), Brazil; Marco Perin Hospital Israelita Albert Einstein, São Paulo (SP), Brazil; Marco V. Wainstein Hospital Moinhos de Vento, Porto Alegre, RS, Brazil; Marcos Marino Hospital Madre Teresa, Nova Lima, MG, Brazil; Maurício L. Prudente Encore Cardiologia e Radiologia Intervencionista, Goiânia, GO, Brazil; Newton Stadler S. Filho Instituto de Neurologia de Curitiba, Curitiba, PR, Brazil; Norberto T. Duda Hospital São Vicente de Paulo, Passo Fundo, RS, Brazil; Paulo Caramori Hospital São Lucas da Pontifícia Universidade Católica de Porto Alegre, Porto Alegre, RS, Brazil; Ricardo A. Costa Instituto Dante Pazzanese de Cardiologia, São Paulo (SP), Brazil; Roberto Botelho Instituto do Coração do Triângulo Mineiro, Uberlândia, MG, Brazil; Rodrigo F. Cardoso Hemocor, Rio de Janeiro, RJ, Brazil; Rogério Sarmento-Leite Instituto de Cardiologia/Fundação Universitária de Cardiologia, Porto Alegre, RS, Brazil.

References
[1]
P.W. Serruys, S. Silber, S. Garg, R.J. van Geuns, G. Richardt, P.E. Buszman, et al.
Comparison of zotarolimus-eluting and everolimus-eluting coronary stents.
N Engl J Med., 363 (2010), pp. 136-146
[2]
S. Windecker, P.W. Serruys, S. Wandel, P. Buszman, S. Trznadel, A. Linke, et al.
Biolimus-eluting stent with biodegradable polymer versus sirolimus-eluting stent with durable polymer for coronary revascularisation (LEADERS): a randomised non-inferiority trial.
Lancet., 372 (2008), pp. 1163-1173
[3]
L. Räber, M. Magro, G.G. Stefanini, B. Kalesan, R.T. van Domburg, Y. Onuma, et al.
Very late coronary stent thrombosis of a newer-generation everolimus-eluting stent compared with early-generation drug-eluting stents: a prospective cohort study.
Circulation., 125 (2012), pp. 1110-1121
[4]
J.W. Moses, M.B. Leon, J.J. Popma, P.J. Fitzgerald, D.R. Holmes, C. O'Shaughnessy, et al.
SIRIUS Investigators. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery.
N Engl J Med., 349 (2003), pp. 1315-1323
[5]
G.W. Stone, S.G. Ellis, D.A. Cox, J. Hermiller, C. O'Shaughnessy, J.T. Mann, et al.
; TAXUS-IV Investigators. A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease.
N Engl J Med., 350 (2004), pp. 221-231
[6]
P.W. Serruys, A.T. Ong, J.J. Piek, F.J. Neumann, W.J. van der Giessen, M. Wiemer, et al.
A randomized comparison of a durable polymer Everolimus-eluting stent with a bare metal coronary stent: The SPIRIT first trial.
EuroIntervention., 1 (2005), pp. 58-65
[7]
R.A. Costa, A.J. Lansky, G.S. Mintz, R. Mehran, Y. Tsuchiya, M. Negoita, et al.
Angiographic results of the first human experience with everolimus-eluting stents for the treatment of coronary lesions (the FUTURE I trial).
Am J Cardiol., 95 (2005), pp. 113-116
[8]
R.A. Costa, A.J. Lansky, A. Abizaid, R. Müeller, Y. Tsuchiya, K. Mori, et al.
Angiographic results of the first human experience with the Biolimus A9 drug-eluting stent for de novo coronary lesions.
Am J Cardiol., 98 (2006), pp. 443-446
[9]
I.T. Meredith, S. Worthley, R. Whitbourn, D.L. Walters, D. McClean, M. Horrigan, et al.
; RESOLUTE Investigators. Clinical and angiographic results with the next-generation resolute stent system: a prospective, multicenter, first-in-human trial.
JACC Cardiovasc Interv., 2 (2009), pp. 977-985
[10]
I.T. Meredith, R. Whitbourn, D. Scott, S. El-Jack, R. Zambahari, G.W. Stone, et al.
PLATINUM QCA: a prospective, multicentre study assessing clinical, angiographic, and intravascular ultrasound outcomes with the novel platinum chromium thin-strut PROMUS Element everolimus-eluting stent in de novo coronary stenoses.
EuroIntervention., 7 (2011), pp. 84-90
[11]
S. Dani, R.A. Costa, H. Joshi, J. Shah, R. Pandya, R. Virmani, et al.
First-in-human evaluation of the novel BioMime sirolimus-eluting coronary stent with bioabsorbable polymer for the treatment of single de novo lesions located in native coronary vessels - results from the meriT-1 trial.
EuroIntervention., 9 (2013), pp. 493-500
[12]
E.E. Ribeiro, C.M. Campos, H.B. Ribeiro, A.C. Lopes, R.B. Esper, G.X. Meirelles, et al.
First-in-man randomised comparison of a novel sirolimus-eluting stent with abluminal biodegradable polymer and thin-strut cobalt-chromium alloy: INSPIRON-I trial.
EuroIntervention., 9 (2014), pp. 1380-1384
[13]
I.T. Meredith, S. Verheye, C.L. Dubois, J. Dens, J. Fajadet, D. Carrié, et al.
Primary endpoint results of the EVOLVE trial: a randomized evaluation of a novel bioabsorbable polymer-coated, everolimus-eluting coronary stent.
J Am Coll Cardiol., 59 (2012), pp. 1362-1370
[14]
E. Kedhi, K.S. Joesoef, E. McFadden, J. Wassing, C. van Mieghem, D. Goedhart, et al.
Second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice (COMPARE): a randomised trial.
Lancet., 375 (2010), pp. 201-209
[15]
T. Kimura, T. Morimoto, M. Natsuaki, H. Shiomi, K. Igarashi, K. Kadota, et al.
RESET Investigators. Comparison of everolimus-eluting and sirolimus-eluting coronary stents: 1-year outcomes from the Randomized Evaluation of Sirolimus-eluting Versus Everolimus-eluting stent Trial (RESET).
Circulation., 126 (2012), pp. 1225-1236
[16]
K.W. Park, I.H. Chae, D.S. Lim, K.R. Han, H.M. Yang, H.Y. Lee, et al.
Everolimus-eluting versus sirolimus-eluting stents in patients undergoing percutaneous coronary intervention: the EXCELLENT (Efficacy of Xience/Promus Versus Cypher to Reduce Late Loss After Stenting) randomized trial.
J Am Coll Cardiol., 58 (2011), pp. 1844-1854
[17]
G.W. Stone, M. Midei, W. Newman, M. Sanz, J.B. Hermiller, J. Williams, et al.
SPIRIT III Investigators. Comparison of an everolimus-eluting stent and a paclitaxel-eluting stent in patients with coronary artery disease: a randomized trial.
JAMA., 299 (2008), pp. 1903-1913
[18]
G.W. Stone, A. Rizvi, W. Newman, K. Mastali, J.C. Wang, R. Caputo, et al.
SPIRIT IV Investigators. Everolimus-eluting versus paclitaxel-eluting stents in coronary artery disease.
N Engl J Med., 362 (2010), pp. 1663-1674
[19]
C. von Birgelen, M.W. Basalus, K. Tandjung, K.G. van Houwelingen, M.G. Stoel, J.H. Louwerenburg, et al.
A randomized controlled trial in second-generation zotarolimus-eluting Resolute stents versus everolimus-eluting Xience V stents in real-world patients: the TWENTE trial.
J Am Coll Cardiol., 59 (2012), pp. 1350-1361
[20]
E.O. Abreu-Silva, R.A. Costa, A.S. Abizaid, M. Perin, R.F. Cardoso, M.L. Prudente, et al.
Stents Farmacológicos liberadores de everolimus XienceTM V no tratamento de pacientes com lesões coronárias complexas na prática diária: resultados iniciais do registro brasileiro BRAVO.
Rev Bras Cardiol Invasiva., 19 (2011), pp. 357-366
[21]
Mattos LA, Lemos PA, Rassi A Jr., Marin-Neto JA, Sousa AGMR, Devito FS, et al. Diretrizes da Sociedade Brasileira de Cardiologia - Intervenção Coronária Percutânea e Métodos Adjuntos Diagnósticos em Cardiologia Intervencionista (II Edição - 2008) [Internet]. Rev Bras Cardiol Invasiva. 2008 [cited 2015 Feb 26]; Suplemento 2. Available from: http://www.rbci.org.br/imageBank/PDF/RBCI_Diretrizes_16-2.pdf.
[22]
D.E. Cutlip, S. Windecker, R. Mehran, A. Boam, D.J. Cohen, G.A. van Es, et al.
Academic Research Consortium. Clinical end points in coronary stent trials: a case for standardized definitions.
Circulation, 115 (2007), pp. 2344-2351
[23]
J.H. Chesebro, G. Knatterud, R. Roberts, J. Borer, L.S. Cohen, J. Dalen, et al.
Thrombolysis in Myocardial Infarction (TIMI) Trial. Phase I: A comparison between intravenous tissue plasminogen activator and intravenous streptokinase. Clinical findings through hospital discharge.
Circulation., 76 (1987), pp. 142-154
[24]
P.W. Serruys, P. de Jaegere, F. Kiemeneij, C. Macaya, W. Rutsch, G. Heyndrickx, et al.
A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease.
Benestent Study Group. N Engl J Med., 331 (1994), pp. 489-495
[25]
G.S. Mintz, J.J. Popma, M.K. Hong, A.D. Pichard, K.M. Kent, L.F. Satler, et al.
Intravascular ultrasound to discern device-specific effects and mechanisms of restenosis.
Am J Cardiol., 78 (1996), pp. 18-22
[26]
A. Kastrati, A. Schömig, R. Dietz, F.J. Neumann, G. Richardt.
Time course of restenosis during the first year after emergency coronary stenting.
Circulation., 87 (1993), pp. 1498-1505
[27]
J.E. Sousa, P.W. Serruys, M.A. Costa.
New frontiers in cardiology: drug-eluting stents: Part I.
Circulation, 107 (2003), pp. 2383-2389
[28]
S. Cassese, R.A. Byrne, T. Tada, S. Pinieck, M. Joner, T. Ibrahim, et al.
Incidence and predictors of restenosis after coronary stenting in 10 004 patients with surveillance angiography.
[29]
J.J. Popma, M.B. Leon, J.W. Moses, D.R. Holmes Jr., N. Cox, M. Fitzpatrick, et al.
Investigators S. Quantitative assessment of angiographic restenosis after sirolimus-eluting stent implantation in native coronary arteries. Circulation, 110 (2004), pp. 3773-3780
[30]
G. Nakazawa, F. Otsuka, M. Nakano, M. Vorpahl, S.K. Yazdani, E. Ladich, et al.
The pathology of neoatherosclerosis in human coronary implants bare-metal and drug-eluting stents.
J Am Coll Cardiol., 57 (2011), pp. 1314-1322
[31]
D. Chamié, J.R. Costa Jr., A. Abizaid.
Neoaterosclerose precoce como causa de reestenose de stent farmacológico de segunda geração.
Rev Bras Cardiol Invasiva., 20 (2012), pp. 333-336
[32]
I. Iakovou, T. Schmidt, E. Bonizzoni, L. Ge, G.M. Sangiorgi, G. Stankovic, et al.
Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents.
JAMA, 293 (2005), pp. 2126-2130
[33]
R.A. Costa, A.G.M.R. Sousa, A. Moreira, J.R. Costa Jr., G. Maldonado, M. Cano, et al.
Trombose de stent farmacológico no “mundo-real”: análise crítica do registro DESIRE (Drug-Eluting Stent in the Real World).
Rev Bras Cardiol Invasiva., 16 (2008), pp. 144-154
[34]
F. Otsuka, M. Vorpahl, M. Nakano, J. Foerst, J.B. Newell, K. Sakakura, et al.
Pathology of second-generation everolimus-eluting stents versus first-generation sirolimus- and paclitaxel-eluting stents in humans.
Circulation., 129 (2014), pp. 211-223
[35]
L.O. Jensen, P. Thayssen, H.S. Hansen, E.H. Christiansen, H.H. Tilsted, L.R. Krusell, et al.
Scandinavian Organization for Randomized Trials With Clinical Outcome IVI. Randomized comparison of everolimus-eluting and sirolimus-eluting stents in patients treated with percutaneous coronary intervention: the Scandinavian Organization for Randomized Trials with Clinical Outcome IV (SORT OUT IV).
Circulation, 125 (2012), pp. 1246-1255

A complete list of the names of BRAVO study investigators appears in the Acknowledgements section, at the end of the article.