metricas
covid
Buscar en
Revista Española de Medicina Nuclear e Imagen Molecular
Toda la web
Inicio Revista Española de Medicina Nuclear e Imagen Molecular Aportación clínica de la SPECT/TC en la gammagrafía con leucocitos marcados c...
Información de la revista
Vol. 38. Núm. 4.
Páginas 212-217 (julio - agosto 2019)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Visitas
352
Vol. 38. Núm. 4.
Páginas 212-217 (julio - agosto 2019)
Original
Aportación clínica de la SPECT/TC en la gammagrafía con leucocitos marcados con 99mTc-HMPAO en infección de prótesis de cadera y rodilla
The clinical contribution of SPECT/CT with 99mTc-HMPAO-labeled leukocyte scintigraphy in hip and knee prosthetic infections
Visitas
352
T. Sengoza,
Autor para correspondencia
tsengoz@pau.edu.tr

Autor para correspondencia.
, O. Yaylalia, D. Yuksela, F. Demirkanb, O. Uluyola
a Pamukkale University, Medical Faculty, Department of Nuclear Medicine, Denizli, Turquía
b Pamukkale University, Medical Faculty, Department of Orthopedics, Denizli, Turquía
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (2)
Tablas (2)
Tabla 1. Características demográficas y resultados de la gammagrafía con leucocitos marcados con 99mTc-HMPAO (planar y SPECT/TC) en el grupo de positivos para infección de la prótesis
Tabla 2. Características demográficas y resultados de la gammagrafía con leucocitos marcados con 99mTc-HMPAO (planar y SPECT/TC) en el grupo de negativos para infección de la prótesis
Mostrar másMostrar menos
Resumen
Objetivo

La gammagrafía con leucocitos marcados con 99mTc-HMPAO ha resultado un método de estudio específico y altamente sensible en el diagnóstico y seguimiento de pacientes con sospecha de infección protésica. El objetivo de este estudio retrospectivo fue evaluar la utilidad de la SPECT/TC en infección protésica.

Material y métodos

Se realizó una gammagrafía con leucocitos marcados con 99mTc-HMPAO a 37 pacientes con prótesis articular (11 hombres y 26 mujeres; rango de edades de 38 a 84 años; edad media±DE, 65,7±5,6 años). Se obtuvieron imágenes planares 2, 4 y 24horas después de la inyección. A las 4horas se realizó SPECT/TC usando una gammacámara híbrida de doble detector con TC de baja energía. En todos los pacientes se compararon los resultados de la gammagrafía con los resultados de la intervención quirúrgica, el cultivo y el seguimiento clínico.

Resultados

De 37 pacientes estudiados con leucocitos marcados con 99mTc-HMPAO, con gammagrafía y SPECT/TC, 17 (45,9%) tenían infección protésica y 20 (54,1%) tenían afecciones protésicas no infecciosas. La gammagrafía con leucocitos marcados con 99mTc-HMPAO fue verdadero positivo para infección en 16 de 37 pacientes y verdadero negativo en 20 de 37 pacientes. La SPECT/TC proporciona una localización anatómica precisa de todos los posibles focos. Considerando el diagnóstico final, la SPECT/TC aportó una contribución clínica significativa en 22 de 37 pacientes (59,4%). La sensibilidad, especificidad, valor predictivo negativo y valor predictivo positivo fueron del 100%, 59,1%, 100%, 62,5% en las imágenes planares y de 100%, 90,1%, 100%, 88,2% en la imagen planar más SPECT/TC respectivamente.

Discusión

Nuestros resultados indican que la realización de la SPECT/TC puede mejorar el estudio con leucocitos marcados con 99mTc-HMPAO en pacientes con sospecha de osteomielitis, y proporcionar una localización anatómica y una definición precisa del alcance de la infección.

Palabras clave:
Gammagrafía con leucocitos marcados con 99mTc-HMPAO
Inflamación
SPECT
SPECT/TC
Abstract
Objectives

White blood cell scanning with 99mTc-hexamethylpropylene amine oxime (HMPAO) has proven a sensitive and specific imaging method in the diagnosis of suspected prosthesis infection. The aim of this retrospective study was to evaluate the usefulness of SPECT/CT performed simultaneously using a hybrid imaging device of prosthesis infections.

Materials and methods

99mTc-HMPAO scintigraphy was performed on 37 patients (11 men and 26 women; age range 38-84 years; mean age±SD, 65.7±5.6 years). Planar scans were acquired 2.4 and 24hour after injection. SPECT/CT was obtained 4 h after injection, using a dual-head hybrid gama camera coupled with a low-power x-ray tube. In all patients, scintigraphic results were matched with the results of surgery, cultures and clinical follow-up.

Results

Seventeen (45,9%) out of 37 patients had prosthesis infection and 20 (54,1%) out of 37 patients had non-infectious prosthesis pathologies with 99mTc-HMPAO scintigraphy and SPECT/CT. The 99mTc-HMPAO scintigraphy was true-positive for infection in 16 of 37 patients and true-negative in 20 of 37 patients. SPECT/CT provided an accurate anatomic localization of all positive foci. With regard to the final diagnosis, SPECT/CT added a significant clinical contribution in 22 of 37 patients (59,4%). Sensitivity, specificity, negative predictive value and positive predictive values were 100%,59.1%,100%,62.5% in planar images with 99mTc-HMPAO scintigraphy and 100%,90.1%,100%,88.2% in the planar+SPECT/CT imaging, respectively.

Discussion

Our results indicate that SPECT/CT performed using a hybrid device can improve imaging with 99mTc-HMPAO scintigraphy in patients with suspected osteomyelitis by providing accurate anatomic localization and precise definition of the extent of infection.

Keywords:
99mTc-HMPAO–labeled leukocyte scintigraphy
Inflammation
SPECT
SPECT/CT

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Medicina Nuclear e Imagen Molecular
Socio
Si es usted socio de la Sociedad Española de Medicina Nuclear e Imagen Molecular (SEMNIM) puede acceder al texto completo de los contenidos de la Revista Española de Medicina Nuclear e Imagen Molecular desde los enlaces a la revista publicados en la web de la SEMNIN (enlace a https://semnim.es/iniciar-sesion/), previo inicio de sesión como socio. Si tiene problemas de acceso puede contactar con la Secretaría Técnica de la SEMNIM en el correo electrónico secretaria.tecnica@semnim.es o en el teléfono: + 34 619 594 780
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Medicina Nuclear e Imagen Molecular

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos