metricas
covid
Buscar en
Acta Otorrinolaringológica Española
Toda la web
Inicio Acta Otorrinolaringológica Española Despistaje de la hipoacusia neonatal: resultados después de 3 años de iniciar ...
Información de la revista
Vol. 56. Núm. 2.
Páginas 55-58 (febrero 2005)
Compartir
Compartir
Descargar PDF
English PDF
Más opciones de artículo
Vol. 56. Núm. 2.
Páginas 55-58 (febrero 2005)
Despistaje de la hipoacusia neonatal: resultados después de 3 años de iniciar nuestro programa
Neonatal hearing loss screening: our results three years after starting the program
Visitas
3093
J.C. Méndez Colunga*,a, J.C. Álvarez Méndez**, J.M. Carreño Villarreal**, M.J. Álvarez Zapico**, C. Manrique Estrada**, M.L. Fernández Álvarez***, F. García Díez***
* Jefe Servicio ORL
** Adjunto Servicio ORL
*** D.U.E. Servicio de ORL. Hospital de Cabueñes. Gijón. Asturias
Este artículo ha recibido
Información del artículo
Resumen

Desde los años 90 hay un gran interés en la detección precoz de la hipoacusia, tanto por la posibilidad real de hacer un despistaje universal, como por la posibilidad de una intervención temprana. Ello ha provocado la instauración de programas de detección precoz de la hipoacusia basados fundamentalmente en el empleo de otoemisiones acústicas, además de un gran aumento de la literatura científica en este campo. Nuestro hospital inició el programa de detección universal de la hipoacusia neonatal mediante otoemisiones acústicas evocadas por clic en marzo de 2000, utilizando un equipo Capella Cochlear Emissions (MADSEN Electronics). Hasta mayo de 2003 hemos realizado la prueba en 6372 niños de una edad media de 71 días. En nuestro estudio la sensibilidad fue del 90,9% y la especificidad del 99,7%. Nuestros resultados son similares a los de la literatura, si bien la edad media de los niños estudiados es netamente superior y hemos encontrado una incidencia de hipoacusia inferior a otros estudios

Palabras clave:
Hipoacusia neonatal
Despistaje
Otoemisiones acústicas
Abstract

Since the 90s there increasing interest in early detection of neonatal hearing loss due to the feasibility of universal neonatal screening as well as to the possibility of early intervention. This has led to set up neonatal screening programs based upon otoacoustic emissions and to a great increase in the number of publications in the field. Our hospital started a neonatal hearing loss screening program using otoacoustic emission in March 2000. We used a Capella Capella Cochlear Emissions (MADSEN electronics) equipment. Until May 2003 we have performed the test in 6372 children with a median age of 71 days. In our study, the sensibility of the test was 90.9% and the specificity 99.7%. Our results are similar to those reported in the literature although the age of the children was higher and we have found an incidence of hearing loss lower than other studies

Key words:
Neonatal hearing loss
Screening
Otoacoustic emissions

Artículo

Opciones para acceder a los textos completos de la publicación Acta Otorrinolaringológica Española
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Acta Otorrinolaringológica Española

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos