Perforating endoscopic surgery (PES) is a safe, efficient procedure for the treatment of chronic venous insufficiency with perforator incompetence. One of the advances in modern surgery is the harmonic scalpel (HS), which allows cutting and coagulation in a precise site, with minimum lateral heat damage. The procedure will be easier to carry out with this instrument.
AimsThe aim of this study was to show the value of HS in PES.
Patients and methodsA prospective study involving 39 consecutive patients who were submitted to surgery in the Phlebology Unit at the University Hospital in Caracas. These patients were classified according to the CEAP: C4 7%, C5 45%, C6 48%. PES was performed with HS and the following parameters were determined: surgery time, visualisation of perforators in the work channel, and post-operative progress.
ResultsThe procedure was performed in an average time of 37minutes (20-60min) and 2-4 perforators were identified in Linton's channel, where optimal visualisation was obtained. No complications associated with the use of HS appeared. The follow-up of the patients reported a 100% improvement in symptoms and 72% of the C6 patients were reclassified as C5 in a follow-up time of 4-10 weeks.
ConclusionsHS constitutes a safe, reliable method that enables PES to be performed, lowers surgery time and leaves an appropriate workspace, with no complications associated to its use.
La cirugía endoscópica de perforantes (CEP) es un procedimiento seguro y eficaz para el tratamiento de la insuficiencia venosa crónica con incompetencia de perforantes. Entre los adelantos de la cirugía moderna contamos con el bisturí armónico (BA) con corte y coagulación en un sitio preciso, con un daño térmico lateral mínimo; este instrumento facilitará la realización del procedimiento.
ObjetivoDemostrar la utilidad del BA en la CEP.
Pacientes y métodosEstudio prospectivo de 39 pacientes consecutivos, intervenidos en la Unidad de Fleblogía del Hospital Universitario de Caracas, clasificados según CEAP: C4 7%, C5 45%, C6 48%; se realiza CEP con BA, y se determina el tiempo quirúrgico, la visualización de perforantes en el canal de trabajo y la evolución posoperatoria.
ResultadosEl procedimiento se realizó en un tiempo promedio de 37minutos (20-60min), y se identificaron 2-4 perforantes en el canal de Linton, donde se obtuvo una óptima visualización. No se presentaron complicaciones asociadas al uso del BA. El seguimiento de los pacientes muestra una mejoría de los síntomas en el 100%, y la reclasificación del 72% de los pacientes C6 en C5 en un tiempo de seguimiento de 4-10 semanas.
ConclusiónEl BA constituye un método seguro y fiable que permite la realización de la CEP, disminuye el tiempo quirúrgico y deja un espacio de trabajo adecuado, sin complicaciones asociadas a su uso.
A cirurgia endoscópica das perfurantes (CEP) é um procedimento seguro e eficaz para o tratamento da insuficiência venosa crónica com incompetência das perfurantes. Entre os avanços da cirurgia moderna contamos com o bisturi harmónico (BH) com corte e coagulação num sítio preciso, com lesão térmica lateral mínima; este instrumento facilitará a realização do procedimento.
ObjectivoDemonstrar a utilidade do BH na CEP.
Doentes e métodosEstudo prospectivo de 39 doentes consecutivos, submetidos a intervenção na Unidade de Flebologia do Hospital Universitário de Caracas, classificados segundo o CEAP: C4 7%, C5 45%, C6 48%; realiza-se CEP com BH, e determina-se: tempo cirúrgico, visualização de perfurantes no campo de trabalho, evolução pós-operatória.
ResultadosO procedimento realizouse num tempo médio de 37minutos (20-60min), e identificaram-se 2-4 perfurantes no canal de Linton, donde se obteve uma óptima visualização. Não se apresentaram complicações associadas ao uso do BH. O seguimento dos doentes comunica uma melhoria dos sintomas em 100%, e a reclassificação de 72% dos doentes C6 em C5 num tempo de seguimento de 4 a 10 semanas.
Conclusão.O BH constitui um método seguro e fiável que permite a realização da CEP, diminui o tempo cirúrgico e deixa um espaço de trabalho adequado, sem complicações associadas ao seu uso.