metricas
covid
Buscar en
Archivos de la Sociedad Española de Oftalmología
Toda la web
Inicio Archivos de la Sociedad Española de Oftalmología Albinismo ocular con mutación en GPR143: hallazgos en autofluorescencia de camp...
Información de la revista
Vol. 94. Núm. 6.
Páginas 288-292 (junio 2019)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Visitas
72
Vol. 94. Núm. 6.
Páginas 288-292 (junio 2019)
Comunicación corta
Albinismo ocular con mutación en GPR143: hallazgos en autofluorescencia de campo amplio y tomografía de coherencia óptica
Ocular albinism with mutation in GPR143: Findings in wide-field autofluorescence and optical coherence tomography
Visitas
72
M.J. Montoya Delgado
Autor para correspondencia
manuel.montiya77@gmail.com

Autor para correspondencia.
, M.C. Astiazarán, F. Casanova Imken, A. Ramírez Estudillo, Á. Hernández Vázquez
Departamento de Retina y Vítreo, Fundación Hospital Nuestra Señora de la Luz, Ciudad de México, México
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (3)
Mostrar másMostrar menos
Resumen

Varón de 12 años que consulta por nistagmo y visión baja desde el nacimiento. Su madre también consulta por visión baja de ojo derecho desde pequeña que empeoró últimamente. El examen físico no reveló alteraciones en la pigmentación de piel y cabello. En el examen del segmento anterior del niño se observaron áreas de hipopigmentación circunferencial leve de iris en ambos ojos. El examen de fondo de ojo reveló un fondo coroideo por ausencia de melanina en el epitelio pigmentario retiniano. En la autofluorescencia se observa una ausencia de la hipoautofluorescencia macular fisiológica y en la tomografía de coherencia óptica se objetivó hipoplasia foveal en ambos ojos. En el examen de fondo de ojo de la madre se observaron cambios pigmentarios maculares tenues en el ojo derecho y unas manchas radiadas hiperpigmentadas en la periferia retiniana de ambos ojos que en la autofluorescencia de campo amplio se vieron hipoautofluorescentes. En la tomografía de coherencia óptica del ojo derecho se objetivó una cavitación de las capas externas retinianas en la fóvea. Se hace el estudio genético por secuenciación nucleotídica en madre e hijo y se encuentra una mutación en el gen GPR143: el niño fue hemicigote y la madre heterocigote. Se diagnostica albinismo ocular ligado a X y se realiza el aconsejamiento genético respectivo.

El albinismo ocular ligado a X es la variante genética más frecuente de esta enfermedad. Si bien las alteraciones pigmentarias periféricas en las madres heterocigotas fueron descritas en la literatura previamente, no existen reportes de cavitaciones en las capas retinianas externas por tomografía de coherencia óptica.

Palabras clave:
Albinismo ocular
Autofluorescencia de campo amplio
Cavitación de capas externas retinianas
Abstract

A 12 year-old boy who consulted due to nystagmus and low vision from birth. His mother also consulted for low vision of the right eye since she was a child, which worsened recently. The physical examination revealed no alterations in skin and hair pigmentation. In the examination of the anterior segment of the child, areas of slight circumferential hypopigmentation were observed in the iris in both eyes. The fundus examination revealed a choroidal fundus due to the absence of melanin in the retinal pigment epithelium. In the autofluorescence, an absence of physiological macular hypo-autofluorescence was observed and, in optical coherence tomography, foveal hypoplasia was observed in both eyes. In the ocular fundus examination of the mother, slight macular pigmentary changes were observed in the right eye, with hyperpigmented radiated spots in the retinal periphery of both eyes, which were hypo-autofluorescent in the wide-field autofluorescence. In the optical coherence tomography of the right eye, a cavitation of the outer retinal layers was observed in the fovea. The genetic study by nucleotide sequencing was performed on the mother and the child. In the mutation found in the GPR143 gene, the son was hemizygous and the mother was heterozygous. X-linked ocular albinism was diagnosed and the genetic counselling was carried out.

Ocular albinism linked to X is the most frequent genetic variant of this disease. Peripheral pigment alterations in heterozygous mothers have been previously described in the literature, but there are no reports of cavitations in the external retinal layers using optical coherence tomography.

Keywords:
Ocular albinism
Wide-field autofluorescence
Retinal outer layer cavitations

Artículo

Opciones para acceder a los textos completos de la publicación Archivos de la Sociedad Española de Oftalmología
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Archivos de la Sociedad Española de Oftalmología

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

Quizás le interese:
10.1016/j.oftal.2020.11.025
No mostrar más