covid
Buscar en
Colombian Journal of Anesthesiology
Toda la web
Inicio Colombian Journal of Anesthesiology Comment about “Randomized cross-over clinical trial comparing two pharmacokine...
Información de la revista
Vol. 45. Núm. S2.
Páginas 80-81 (diciembre 2017)
Vol. 45. Núm. S2.
Páginas 80-81 (diciembre 2017)
Brief Academy
Open Access
Comment about “Randomized cross-over clinical trial comparing two pharmacokinetic models of propofol using entropy indices”
Comentario acerca de “Ensayo clínico cruzado y aleatorizado para comparar 2 modelos farmacocinéticos de propofol usando índices de entropía”
Visitas
974
Jaime Torres Cruz
Autor para correspondencia
jtorresc62@yahoo.com

Correspondence to: Calle 13 27-60, Duitama, Colombia.
E.S.E. Hospital San Rafael de Tunja, Tunja, Colombia
Este artículo ha recibido

Under a Creative Commons license
Información del artículo
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Texto completo

The article, “Clinical cross-section, randomized clinical trial comparing two pharmacokinetic propofol models using entropy indexes”,1 published in the July–September 2016 journal, although an interesting and novel idea, it seems to me that a big mistake was made in the study's clinical design, that totally invalidates the results. The fact is that administering a bolus of propofol of 1mg per kg of weight to place a laryngeal mask, after starting the infusion, makes unrealistic the target concentration assigned to the pump, since the infusion pump “ignores” the bolus administration. Under the TCI modality of the intelligent infusion pumps, the pumps themselves administer the bolus as needed; in other words, when the anesthetist starts the infusion or increases the target concentration2; if greater anesthetic depth was needed, the target concentration should have been increased, instead of manually administering a bolus. Moreover, since each patient acts as his/her own control, this same bolus results in differences in propofol concentrations at each time period, since during each patient's second phase, the bolus is not administered. Furthermore, although the statistical work done by the authors endorse that results are achieved with just 14 patients, the fact that the general anesthesia has been assisted with a peripheral nerve block, which may not generate the same results in all patients, represents a major bias of the study, as Dr. Rosero states in his editorial.3

Financing

The author did not receive any sponsorship for preparing this article.

Conflicts of interest

The author has no conflicts of interest to disclose.

References
[1]
O.L. Mosquera-Dussán, A. Cárdenas, D.A. Botero-Rosas, A. Yepes, H. Oliveros, R. Henao.
Ensayo clínico cruzado y aleatorizado para comparar 2 modelos farmacocinéticos de propofol usando índices de entropía.
Rev Colomb Anestesiol, 44 (2016), pp. 194-202
[2]
M.M. Struys, T. De Smet, J.I. Glen, H.E. Vereecke, A.R. Absalom, T.W. Schnider.
The history of target-controlled infusion.
Anesth Analg, 122 (2016), pp. 56-69
[3]
E.B. Rosero.
La caracterización de la profundidad de la anestesia durante las infusiones controladas a objetivo: no es un trabajo fácil.
Rev Colomb Anestesiol, 44 (2016), pp. 187-189

Please cite this article as: Torres Cruz J. Comentario acerca del artículo “Ensayo clínico cruzado y aleatorizado para comparar 2 modelos farmacocinéticos de propofol usando índices de entropía”. Rev Colomb Anestesiol. 2017;45:80–81.

Descargar PDF
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos