Inicio Colombian Journal of Anesthesiology The passive leg raising test (PLR)
Información de la revista
Vol. 43. Núm. 3.
Páginas 214-218 (julio - septiembre 2015)
Visitas
9394
Vol. 43. Núm. 3.
Páginas 214-218 (julio - septiembre 2015)
Review
Acceso a texto completo
The passive leg raising test (PLR)
Prueba de elevación de piernas pasiva
Visitas
9394
Jorge Iván Alvarado-Sáncheza,b,
Autor para correspondencia
jialvarados@unal.edu.co

Correspondence to: Calle 15 sur No. 24G-31, Apt. 403, Bogotá, Colombia.
a Anesthesiologist, Centro Policlínico del Olaya, Bogotá, Colombia
b Intensive Cares, Fundación Hospital San Carlos, Bogotá, Colombia
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Abstract
Introduction

The passive leg raising test (PLR) allows physicians to determine which patients require treatment with intravenous fluids.

Objectives

It is important to be aware of tools that help us to determine the response to the passive leg raising test, as well as understanding in which clinical situations it can be performed.

Materials and methods

Non-systematic review. Medline and PubMed databases were consulted in search of relevant articles.

Results

Through echocardiography, pulse pressure and capnography can be determined as a response to leg raising.

Conclusions

This article explores the tools that are useful in determining the response to this maneuver, and the clinical conditions in which it is indicated.

Keywords:
Shock
Ultrasonography
Echocardiography
Pulse
Anesthesia
Resumen
Introducción

la prueba de elevación de piernas pasivas permite determinar en qué paciente se requiere manejo con líquidos endovenosos.

Objetivos

es importante conocer las herramientas que ayudan a determinar la respuesta a la prueba de elevación de piernas pasiva, además conocer en qué situaciones clínicas se puede realizar.

Materiales y métodos

revisión no sistemática. Se consultaron las siguientes bases de datos Medline y Pubmed, en búsqueda de artículos relevantes.

Resultados

mediante ecocardiografía, presión de pulso y capnografía se puede determinar la respuesta a la elevación de piernas.

Conclusiones

el presente artículo explora las herramientas que son útiles para determinar la respuesta a esta maniobra y las condiciones clínicas donde se indica.

Palabras clave:
Choque
Ultrasonografía
Echocardiografía
Pulso arterial
Anestesia
Texto completo
Introduction

When we approach a patient with circulatory shock, we always ask ourselves if this patient requires resuscitation with intravenous fluids. More or less 50% of patients in the Intensive Care Unit (ICU) respond to the administration of intravenous fluids. This response is defined as an increase in Cardiac Output (CO) between 10% and 15% after the administration of intravenous fluids1,2.

Energetic resuscitation with intravenous fluids can contribute to the development of pulmonary edema, respiratory failure, prolonged periods of mechanical ventilation, and abdominal hypertension3,4. Furthermore, the positive balance of fluids is related to an increase in mortality.5 Directed therapy reduces the incidence of thirst, drowsiness, postoperative nausea, morbidity, and serum acid levels, as well as the length of hospital stay, the number of postoperative complications, the duration of mechanical ventilation, and days in the ICU6–13. As such, it is crucial to appropriately direct fluid therapy.

Materials and methods

This is a non-systematic review. The Medline and PubMed databases were consulted. The following keywords were chosen for the searches: fluid responsiveness, stroke volume, blood flow, shock, Doppler, echocardiography. These were related with: intra-abdominal hypertension, pulse contour analysis, pulse pressure variation, systolic pressure variation, systolic volume variability, respiratory distress syndrome, and pediatrics.

Results

There are several tests that allow us to assess the probability that a patient will respond to therapy with intravenous fluids. The static measures of cardiac preload, filling pressure, and volume are poor predictors of fluid responsiveness1,14,15. Dynamic measures, based on heart–lung interaction, like Systolic Blood Pressure Variation (SBPV), Pulse Pressure Variation (PPV), and Stroke Volume Variability (SVV) have been shown to be good indicators of the need for fluid therapy2,16–20. In clinical situations where there is no heart–lung interaction, these variables are not appropriate21. An example would be a patient with spontaneous respiration and arrhythmias.

The response to passive leg raising (PLR) has turned out to be a good indicator of response to fluid. The PLR test is a reversible maneuver and simulates a rapid infusion of fluids since the blood moves out of the lower limbs22 and the abdominal compartment23 through the intra-thoracic compartment24. This leads to an increase of left and right cardiac preload (autotransfusion), with later temporary increase in stroke volume (SV) and cardiac output.

Physiological response to leg raising

PLR mobilizes an average of 300ml of blood from the lower limbs13 and could move a bit more blood if it is initiated in the semi-sitting position, since it also mobilizes blood in the abdominal compartment14. The increase in volume in patients dependent on preload leads to an increase in SV. These changes are reversible and rapid. It requires quick methods for measuring CO or SV. For this reason, the thermodilution method is not applicable, even in automatic and semi-continuous modes, because these methods require at least 10min to detect changes in CO. There are different ways of determining the response to this test, such as the increase in aortic blood flow through esophageal Doppler, changes in pulse pressure, VTI (velocity time integral), cardiac output (CO) (through transesophageal echocardiogram or transthoracic echocardiogram) and stroke volume (SV) (TEE, TTE or Vigileo).

In theory, the best indicator of response to PLR is the increase in SV or CO. Aortic pulse pressure is directly proportional to the SV of the left ventricle, and if arterial distensibility is not altered, the pulse pressure should show an increase in SV. Boulain et al25. found a relationship between changes in radial pulse pressure (PP) and SV (r=0.77, p<0.001) during PLR. PP increase is maintained for up to 4min. The correlation indexes are adequate but not excellent. This is due, certainly, to the fact that radial pulse pressure does not reflect changes in pressure of the aortic pulse due to phenomena of propagation and reflection of the pressure wave during changes in blood flow induced by the raising of the legs. This study was conducted on a patient undergoing controlled mechanical ventilation and calculating CO with a pulmonary artery catheter25.

The esophageal Doppler provides an adequate measure of blood flow in the descending aorta. This is a good indicator of overall CO26 and has a good correlation with the pulmonary artery catheter27. Lafanechere et al28. wanted to improve the predictive value of this test through a more direct method for estimating SV. Through respiratory changes of the pulse pressure and changes in blood flow in the descending aorta, they found that an increase in blood flow in the descending aorta by more than 8% with the raising of the legs predicts fluid response with a sensitivity of 90% and a specificity of 83%. The positive predictive value is 82% and the negative predictive value is 91%. Pulse pressure variation greater than 12% has a sensitivity of 70% and a specificity of 92%28.

Changes in pulse pressure due to changes in SV also depend on arterial compliance and vasomotor tone29. For this reason, Monnet et al30. in their study compared changes in aortic blood flow, PPV, and PP during leg raising in two types of patients: those under controlled mechanical ventilation and without arrhythmias and those with invasive spontaneous ventilation and arrhythmias. They found that an increase in blood flow greater than or equal to 10% with PLR predicted fluid response with a sensitivity of 97% and a specificity of 94% (ROC 0.96). This increase in flow occurred after 30s. An increase in PP greater than or equal to 12% with PLR predicted fluid response with a sensitivity of 60% and a specificity of 85% (ROC 0.75). In patients under controlled ventilation and without arrhythmias, a PPV greater than 12% predicted fluid response with a sensitivity of 88% and a specificity of 93%. In patients that presented spontaneous breathing on the ventilator and arrhythmias, the specificity of the PPV falls30.

Nevertheless, measuring aortic blood flow with an esophageal Doppler can be more uncomfortable since it requires profound sedation and cannot be performed on patients without invasive ventilation. Negative intrathoracic pressure during mechanical ventilation can change the amount of increase in blood volume and the response of baroreceptors. Added to this, arterial tone may be modified during sedation, which changes the response to the increase or decrease in volume31. The data from the above studies was found from intubated and sedated patients. Thus we recommend that these studies be validated in non-intubated patients.

Lamia et al32. studied the effects of PLR measured with a transthoracic echocardiogram (TTE) and compared them to echocardiographic preload indicators, such as the Left Ventricular Diastolic Area index (LVEDAi), and the relation to diastolic peak wave velocity/lateral mitral annular early wave velocity (E/Ea). They calculated the SV as the product of velocity time integral (VTI) and the area of the aortic valve. They found that the peak of the VTI occurred within the first 90s of PLR. If this maneuver induces increases in VTI, and thus the stroke volume index (SVI), by 12.5% or more, it predicts an increase of 15% or more in the SVI after the infusion of fluids with a sensitivity of 77% and a specificity of 100% in intubated and non-intubated patients. Preload indicators (LVEDAi and E/Ea), however, do not predict fluid responsiveness32. In the study by Maizel et al31., they also used TTE on non-intubated patients and showed similar results31. In a study by Préau et al33., good sensitivity and specificity of PLR was also found for measuring changes in SV with TTE in non-intubated patients with sepsis and pancreatitis. These studies allow us to measure the response to PLR with TTE in patients that are not under invasive mechanical ventilation to determine the need for intravenous fluids.

The aforementioned studies have several limitations. To calculate SV with TTE or TEE, the aortic diameter is required to calculate the aortic area. The aortic diameter can change due to an increase in SV34. These studies31–33, and the use of esophageal devices that consider aortic diameter to be constant, can increase the false negative rate and thus under estimate the response to intravenous fluids. Inter-observer variability in these studies is less than 5%, which means that less experienced researchers may not obtain the same results35.

Another, more simple, way of determining PLR response, and that is available in Colombian operating rooms and ICUs, is capnography. The quantity of exhaled CO2 is proportional to CO in stable patients from the respiratory and metabolic point of view. Monnet et al36. determined their role in patients under controlled mechanical ventilation with or without arrhythmia. They found that an increase in exhaled CO2 (ETCO2) greater than 5% with PLR predicts an increase in cardiac index (CI) greater than 15% with a sensitivity of 71% and a specificity of 100%, with a significant area under the curve (AUC) (0.93) and acceptable correlation indexes (r2=0.45)36.

PLR requires the quick determination of CO. Biais et al37. tried to determine changes in CO through Vigileo and TTE in patients under spontaneous ventilation. They found an increase in SV with TTE after PLR in the first 90s, just as in Lamia's study. They also found an increase in SV with Vigileo after PLR within the first 2min with acceptable correlation indexes (r2=0.56)37. This result is expected for several reasons. First, the measures for calculating CO with Vigileo are based on heart–lung interaction, which is lost in spontaneous ventilation21. Second, Vigileo in patients with pathologies involving low systemic vascular resistance is not appropriate38–40. The same is true for critically ill patients41.

Importance of the position

Leg raising mobilizes an average of 300ml of blood22, and if it is initiated in the semi-sitting position, it could mobilize an additional 150ml of blood in the abdominal compartment42. Jabot et al23. studied the hemodynamic effect of initiating the PLR maneuver in the semi-sitting position versus the supine position. They found that, if PLR is initiated in the semi-sitting position, the cardiac index increases more than if it is initiated in the supine position. This effect is due to blood gathering from the splanchnic compartment23.

We must take into account that the studies were conducted in a 45° semi-sitting position30,32, 30° semi-sitting position31, or in supine position25,28. The meta-analysis from Cavallaro et al43. found no differences between initiating PLR in dorsal decubitus43.

Passive leg raising test in pediatrics

Like aortic peak flow velocity, PLR predicts an increase in CO in the pediatric population, unlike certain dynamic variables (PPV, SVV, SBPV)44.

Clinical situations in which the passive leg raising test may not be performed

The increase in intra-abdominal pressure leads to important hemodynamic changes in patients in the ICU and surgical units. It leads to an increase in mean arterial pressure (MAP) and SVR, and a decrease in cardiac output secondary to a decrease of blood flow in the vena cava due to collapse45. Furthermore, the increase in intra-abdominal pressure leads to a reduction in pulmonary compliance, which may alter heart–lung interaction. PPV and SVV increase when intra-abdominal pressure increases and continue to be adequate indicators of hypovolemia in this clinical situation46,47. The incidence of elevated intra-abdominal pressure (IAP) in critical patients (defined as IAP greater than or equal to 12mmHg) is 50%. The incidence of abdominal compartment syndrome (IAP greater than or equal to 20mmHg) is 8%48,49. PLR could have false negatives in this kind of patient. Mahjoub et al50. found that intra-abdominal pressure greater than or equal to 16mmHg has a false negative rate of 48% for PLR with a sensitivity of 100% and a specificity of 87.5%50.

In patients with Adult Respiratory Distress Syndrome (ARDS), there are alterations to pulmonary compliance. This is a condition that requires an adequate heart–lung interaction in the patient under invasive controlled mechanical ventilation and sinus rhythm. The dynamic variables, like pulse pressure variation, require pulmonary compliance to be adequate to properly predict fluid responsiveness2. Monnet et al51. found that in patients with pulmonary compliance under 30ml/cm H2O under controlled mechanical ventilation and sinus rhythm, PPV is less acute for determining the need for fluids compared to PLR and the end-expiratory occlusion test (ROC PPV 0.69, PLR 0.94, end-expiratory occlusion test 0.93)51.

Conclusions

PLR is a maneuver that allows physicians to determine which patients require fluid therapy. The response can be determined through an increase in CO or SV with a transesophageal Doppler, a transthoracic echocardiogram, and increase in VTI, PP, and so on. This type of maneuver presents false negatives in patients with increased intra-abdominal pressure. It is superior to PPV in patients with ARDS and pulmonary compliance under 30ml H2O.

Conflicts of interest

The authors have no conflicts of interest to declare.

Funding

None.

References
[1]
D. Osman, C. Ridel, P. Ray, X. Monnet, N. Anguel, C. Richard, et al.
Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge.
[2]
F. Michard, S. Boussat, D. Chemla, N. Anguel, A. Mercat, Y. Lecarpentier, et al.
Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic.
Am J Respir Crit Care Med, 162 (2000), pp. 134-138
[3]
A. Upadya, L. Tilluckdharry, V. Muralidharan, Y. Amoateng-Adjepong, C.a. Manthous.
Fluid balance and weaning outcomes.
Intensive Care Med, 31 (2005), pp. 1643-1647
[4]
M.L.N.G. Malbrain, D. Chiumello, P. Pelosi, D. Bihari, R. Innes, V.M. Ranieri, et al.
Incidence and prognosis of intraabdominal hypertension in a mixed population of critically ill patients: a multiple-center epidemiological study.
Crit Care Med, 33 (2005), pp. 315-322
[5]
F. Alsous, M. Khamiees, A. DeGirolamo, Y. Amoateng-Adjepong, C.A. Manthous.
Negative fluid balance predicts survival in patients with septic shock.
Chest, 117 (2000), pp. 1749-1754
[6]
S. Yogendran, B. Asokumar, C.D. Cheng, H.F. Chung.
A prospective randomized double-blinded study of the effect of intravenous fluid therapy on adverse outcomes on outpatient surgery.
Anesth Analg, 80 (1995), pp. 682-686
[7]
R. Venn, A. Steele, P. Richardson, J. Poloniecki, M. Grounds, P. Newman.
Randomized controlled trial to investigate influence of the fluid challenge on duration of hospital stay and perioperative morbidity in patients with hip fractures.
Br J Anaesth, 88 (2002), pp. 65-71
[8]
M. McKendry, H. McGloin, D. Saberi, L. Caudwell, A.R. Brady, M. Singer.
Randomised controlled trial assessing the impact of a nurse delivered, flow monitored protocol for optimisation of circulatory status after cardiac surgery.
[9]
M.R. Lopes, M.A. Oliveira, V.O.S. Pereira, I.P.B. Lemos, J.O.C. Auler, F. Michard.
Goal-directed fluid management based on pulse pressure variation monitoring during high-risk surgery: a pilot randomized controlled trial.
Crit Care, 11 (2007), pp. R100
[10]
H.G. Wakeling, M.R. McFall, C.S. Jenkins, W.G.A. Woods, W.F.A. Miles, G.R. Barclay, et al.
Intraoperative oesophageal Doppler guided fluid management shortens postoperative hospital stay after major bowel surgery.
Br J Anaesth, 95 (2005), pp. 634-642
[11]
I. Chytra, R. Pradl, R. Bosman, P. Pelnár, E. Kasal, A. Zidková.
Esophageal Doppler-guided fluid management decreases blood lactate levels in multiple-trauma patients: a randomized controlled trial.
Crit Care, 11 (2007), pp. R24
[12]
S. Sinclair, S. James, M. Singer.
Intraoperative intravascular volume optimisation and length of hospital stay after repair of proximal femoral fracture: randomised controlled trial.
Br J Anaesth, 315 (1997), pp. 909-912
[13]
C. Eduardo, L. Sabogal, A. Felipe, C. Rivera, Y. Joya.
Lactato y déficit de bases en trauma: valor pronóstico.
Rev Colomb Anestesiol, 2 (2015), pp. 60-64
[14]
P.E. Marik, M. Baram, B. Vahid.
Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares.
Chest, 134 (2008), pp. 172-178
[15]
A. Kumar, R. Anel, E. Bunnell, K. Habet, S. Zanotti, S. Marshall, et al.
Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects.
Crit Care Med, 32 (2004), pp. 691-699
[16]
P. Azriel, R. Pizov, S. Cotev.
Systolic blood pressure variation is a sensitive indicator of hypovolemia in ventilated dogs subjected to graded hemorrhage.
Anesthesiology, 67 (1987), pp. 498-502
[17]
H. Berkenstadt, N. Margalit, M. Hadani, Z. Friedman, E. Segal, Y. Villa, et al.
Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery.
Anesth Analg, 92 (2001), pp. 984-989
[18]
P.E. Marik, R. Cavallazi, T. Vasu, A. Hirani.
Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature.
Crit Care Med, 37 (2009), pp. 2642-2647
[19]
F. Michard.
Changes in arterial pressure during mechanical.
Anesthesiology, 103 (2005), pp. 34-36
[20]
F.O.I.S. Jardin, J. Farcot, P. Gueret, J.F. Prost, Y. Ozier, J.P. Bourdarias.
Cyclic changes in arterial pulse during respiratory support.
[21]
S. Soubrier, F. Saulnier, H. Hubert, P. Delour, H. Lenci, T. Onimus, et al.
Can dynamic indicators help the prediction of fluid responsiveness in spontaneously breathing critically ill patients?.
Intensive Care Med, 33 (2007), pp. 1117-1124
[22]
D.L. Rutlen, F.J. Wackers, B.L. Zaret.
Radionuclide assessment of peripheral intravascular capacity: a technique to measure intravascular volume changes in the capacitance circulation in man.
Circulation, 64 (1981), pp. 146-152
[23]
J. Jabot, J.-L. Teboul, C. Richard, X. Monnet.
Passive leg raising for predicting fluid responsiveness: importance of the postural change.
Intensive Care Med, 35 (2009), pp. 85-90
[24]
D. Reich, S. Konstadt, S. Raissi.
Trendelenburg position and passive leg raising do not significantly improve cardiopulmonary performance in the anesthetized patient with coronary artery disease.
Crit Care Med, 17 (1989), pp. 313-317
[25]
T. Boulain, J. Achard, J. Teboul, C. Richard, D. Perrotin, G. Ginies.
Changes in BP induced by passive leg raising predict response to fluid loading in critically ill patients.
Chest, 121 (2002), pp. 1245-1252
[26]
B. Valtier, B.P. Cholley, J. Belot, J. De Coussaye, J. Mateo, D.M. Payen.
Noninvasive monitoring of cardiac output in critically ill patients using transesophageal Doppler.
Am J Respir Crit Care Med, 158 (1998), pp. 77-83
[27]
M. Roeck, S.M. Jakob.
Change in stroke volume in response to fluid challenge: assessment using esophageal Doppler.
Intensive Care Med, 29 (2003), pp. 1729-1735
[28]
A. Lafanechère, F. Pène, C. Goulenok, A. Delahaye, V. Mallet, G. Choukroun, et al.
Changes in aortic blood flow induced by passive leg raising predict fluid responsiveness in critically ill patients.
Crit Care, 10 (2006), pp. 1-8
[29]
C. Coirault, K. Zamani, D. Chemla, J. He, I. Suard, P. Colin, et al.
Total arterial compliance estimated by stroke volume-to-aortic pulse pressure ratio in humans.
Am J Physiol, 274 (1998), pp. H500-H505
[30]
X. Monnet, M. Rienzo, D. Osman, N. Anguel, C. Richard, M.R. Pinsky, et al.
Passive leg raising predicts fluid responsiveness in the critically ill.
Crit Care Med, 34 (2006), pp. 1402-1407
[31]
J. Maizel, N. Airapetian, E. Lorne, C. Tribouilloy, Z. Massy, M. Slama.
Diagnosis of central hypovolemia by using passive leg raising.
Intensive Care Med, 33 (2007), pp. 1133-1138
[32]
B. Lamia, A. Ochagavia, X. Monnet, D. Chemla, C. Richard, J. Teboul.
Echocardiographic prediction of volume responsiveness in critically ill patients with spontaneously breathing activity.
Intensive Care Med, 33 (2007), pp. 1125-1132
[33]
S. Préau, F. Saulnier, F. Dewavrin, A. Durocher, J. Chagnon.
Passive leg raising is predictive of fluid responsiveness in spontaneously breathing patients with severe sepsis or acute pancreatitis.
Crit Care Med, 38 (2010), pp. 819-825
[34]
X. Monnet, D. Chemla, D. Osman, N. Anguel, C. Richard, M.R. Pinsky, et al.
Measuring aortic diameter improves accuracy of esophageal Doppler in assessing fluid responsiveness.
Crit Care Med, 35 (2007), pp. 477-482
[35]
D. De Backer, M. Pinsky.
Can one predict fluid responsiveness in spontaneously breathing patients?.
Intensive Care Med, 33 (2007), pp. 1111-1113
[36]
X. Monnet, A. Bataille, E. Magalhaes, J. Barrois, M. Corre, C. Le Gosset, et al.
End-tidal carbon dioxide is better than arterial pressure for predicting volume responsiveness by the passive leg raising test.
Intensive Care Med, 39 (2013), pp. 93-100
[37]
M. Biais, L. Vidil, P. Sarrabay, V. Cottenceau, P. Revel.
Changes in stroke volume induced by passive leg raising in spontaneously breathing patients: comparison between echocardiography and Vigileo™/FloTrac™ device.
Crit Care, 13 (2009), pp. R195
[38]
G. Gouvea, R. Diaz, L. Auler, R. Toledo, J.M. Martinho.
Evaluation of the pulse pressure variation index as a predictor of fluid responsiveness during orthotopic liver transplantation.
Br J Anaesth, 103 (2009), pp. 238-243
[39]
B. Matthieu, N.-G. Karine, C. Vincent, V. Alain, C.J. Francois, R. Philippe, et al.
Cardiac output measurement in patients undergoing liver transplantation: pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis.
Anesth Analg, 106 (2008), pp. 1480-1486
[40]
G. Biancofiore, L.A.H. Critchley, A. Lee, X. Yang, L.M. Bindi, M. Esposito, et al.
Evaluation of a new software version of the FloTrac/Vigileo (Version 3.02) and a comparison with previous data in cirrhotic patients undergoing liver transplant surgery.
Anesth Analg, 113 (2011), pp. 515-522
[41]
F.D. Compton, B. Zukunft, C. Hoffmann, W. Zidek, J.-H. Schaefer.
Performance of a minimally invasive uncalibrated cardiac output monitoring system (Flotrac™/Vigileo™) in haemodynamically unstable patients.
Br J Anaesth, 100 (2008), pp. 451-456
[42]
W. Buhre, A. Weyland, K. Buhre, S. Kazmaier, K. Mursch, M. Schmidt, et al.
Effects of the sitting position on the distribution of blood volume in patients undergoing neurosurgical procedures.
Br J Anaesth, 84 (2000), pp. 354-357
[43]
F. Cavallaro, C. Sandroni, C. Marano, G. La Torre, A. Mannocci, C. De Waure, et al.
Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: systematic review and meta-analysis of clinical studies.
Intensive Care Med, 36 (2010), pp. 1475-1483
[44]
H. Gan, M. Cannesson, J.R. Chandler, J.M. Ansermino.
Predicting fluid responsiveness in children.
Anesth Analg, 117 (2013), pp. 1380-1392
[45]
E. Vivier, O. Metton, V. Piriou, F. Lhuillier, P. Branche, S. Duperret1, et al.
Effects of increased intra-abdominal pressure on central circulation.
Intensive Care Med, 96 (2006), pp. 701-707
[46]
J. Renner, M. Gruenewald, R. Quaden, R. Hanss, P. Meybohm, M. Steinfath, et al.
Influence of increased intra-abdominal pressure on fluid responsiveness predicted by pulse pressure variation and stroke volume variation in a porcine model.
Crit Care Med, 37 (2009), pp. 650-658
[47]
D. Jacques, K. Bendjelid, S. Duperret, J. Colling, V. Piriou, J. Viale.
Pulse pressure variation and stroke volume variation during increased intra-abdominal pressure: an experimental study.
Crit Care, 15 (2011), pp. R33
[48]
M.L. Malbrain, M.L. Cheatham, A. Kirkpatrick, M. Sugrue, M. Parr, J. De Waele, et al.
Results from the international conference of experts on intra-abdominal hypertension and abdominal compartment syndrome. I: Definitions.
Intensive Care Med, 32 (2006), pp. 1722-1732
[49]
M.L. Cheatham, M.L. Malbrain, A. Kirkpatrick, M. Sugrue, M. Parr, J. DeWaele, et al.
Results from the international conference of experts on intra-abdominal hypertension and abdominal compartment syndrome. II: Recommendations.
Intensive Care Med, 33 (2007), pp. 951-962
[50]
Y. Mahjoub, J. Touzeau, N. Airapetian, E. Lorne, U. Hijazi, E. Zogheib, et al.
The passive leg-raising maneuver cannot accurately predict fluid responsiveness in patients with intra-abdominal hypertension.
Crit Care Med, 38 (2010), pp. 1824-1829
[51]
X. Monnet, A. Bleibtreu, M. Dres, R. Gharbi, C. Richard, J. Teboul.
Passive leg-raising and end-expiratory occlusion tests perform better than pulse pressure variation in patients with low respiratory system compliance.
Crit Care Med, 40 (2012), pp. 152-157

Please cite this article as: Alvarado-Sánchez JI. Prueba de elevación de piernas pasiva. Rev Colomb Anestesiol. 2015;43:214–218.

Copyright © 2015. Sociedad Colombiana de Anestesiología y Reanimación
Descargar PDF
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos