Detección y análisis de un brote de Achromobacter xylosoxidans en una unidad de urodinamia
Detection and analysis of an Achromobacter xylosoxidans outbreak in a urodynamics unit
Visitas
42
Simón Juárez Zapataa,
Autor para correspondencia
sjuarez@fundacio-puigvert.es

Autor para correspondencia.
, Carla Benjumea Morenob, Charo Porrónc, Carles Alonso-Tarrésb,d
a Enfermero control de infección, Fundación Puigvert, Barcelona, España
b Microbiología, Fundación Puigvert, Barcelona, España
c Enfermera control de infección, Centro Coordinador Programa VINCat, Hospitalet de Llobregat, Barcelona, España
d Departament de Genètica i Microbiologia, Universitat Autònoma de Barcelona, Cerdanyola del Vallès, Barcelona, España
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (2)
Tablas (2)
Tabla 1. Perfil de sensibilidad de la cepa de Acromobacter xylosoxidans
Tabla 2. Pacientes con cultivo de orina positivo para Achromobacter xylosoxidans
Mostrar másMostrar menos
Resumen
Introducción

Achromobacter xylosoxidans es un bacilo gramnegativo resistente a múltiples antibióticos, presente tanto en el medio ambiente como en hospitales. Este estudio describe un brote de colonizaciones e infecciones por A. xylosoxidans en la unidad de urodinamia de la Fundación Puigvert.

Métodos

El 11 de noviembre de 2022, un paciente presentó fiebre, y se detectó A. xylosoxidans en su orina y sangre. El caso se relacionó con un estudio urodinámico reciente. Debido a esto se revisaron todos los casos de A. xylosoxidans desde 2018, y se realizaron inspecciones en el servicio y se recogieron 24 muestras ambientales.

Resultados

En la revisión de los casos se identificaron 21 pacientes con infecciones por A. xylosoxidans tras procedimientos urodinámicos desde abril de 2022. Los controles microbiológicos ambientales revelaron que los transductores de presión fueron las probables fuentes de infección. Las medidas correctivas incluyeron el cierre temporal del servicio, la limpieza a fondo con hipoclorito, el uso de sondas vesicales de un solo uso, el cambio diario de líneas del equipo y transductores de presión, así como otras mejoras de desinfección, manipulación y circuitos. Se formó un equipo multidisciplinar para implementar y supervisar estas acciones.

Conclusión

Las medidas resultaron en la eliminación del brote y la reanudación segura de las actividades en la unidad. Este incidente subraya la importancia de la vigilancia continua y la respuesta rápida en entornos clínicos para prevenir infecciones y mejorar la seguridad del paciente.

Palabras clave:
Infección urinaria
Brote
Achromobacter xylosoxidans
Urodinamia
Infección relacionada con la asistencia sanitaria
Abstract
Introduction

Achromobacter xylosoxidans is a gramnegative bacillus resistant to multiple antibiotics, present both in the environment and in hospitals. This study describes an outbreak of colonizations and infections by A. xylosoxidans in the urodynamics unit of the Puigvert Foundation.

Methods

On November 11, 2022, a patient developed a fever, and A. xylosoxidans was detected in their urine and blood. The case was linked to a recent urodynamic study. As a result, all A. xylosoxidans cases since 2018 were reviewed, and inspections were conducted in the unit, along with the collection of 24 environmental samples.

Results

The review identified 21 patients with A. xylosoxidans infections after urodynamic procedures since April 2022. Environmental microbiological controls revealed that pressure transducers were the likely source of infection. Corrective measures included the temporary closure of the unit, thorough cleaning with hypochlorite, use of single-use urinary catheters, daily replacement of equipment lines and pressure transducers, as well as other improvements in disinfection, handling, and workflows. A multidisciplinary team was formed to implement and supervise these actions.

Conclusion

The measures resulted in the elimination of the outbreak and the safe resumption of activities in the unit. This incident highlights the importance of continuous surveillance and rapid response in clinical settings to prevent infections and improve patient safety.

Keywords:
Urinary infection
Outbreak
Achromobacter xylosoxidans
Urodynamics
Healthcare-associated infection

Artículo

Opciones para acceder a los textos completos de la publicación Enfermedades Infecciosas y Microbiología Clínica
Socio

Socio de la Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica

Para acceder a la revista

Es necesario que lo haga desde la zona privada de la web de la SEIMC, clique aquí

Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Enfermedades Infecciosas y Microbiología Clínica

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos