metricas
covid
Buscar en
Enfermería Clínica
Toda la web
Inicio Enfermería Clínica Bioaerosol pollution in intensive-care unit of Dr. Wahidin Sudirohusodo Hospital...
Información de la revista
Vol. 30. Núm. S4.
First International Conference on Nutrition and Public Health (ICNPH-2019)
Páginas 35-38 (junio 2020)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Vol. 30. Núm. S4.
First International Conference on Nutrition and Public Health (ICNPH-2019)
Páginas 35-38 (junio 2020)
Bioaerosol pollution in intensive-care unit of Dr. Wahidin Sudirohusodo Hospital Makassar: Morning and midday assessment
Visitas
6
Owildan Wisudawan B.a,
Autor para correspondencia
wildan.graduates@gmail.com

Corresponding author.
, Anwar Mallongib, Syamsiar S. Russengc, Muh Hattad, Anwar Daudb, Muhamad Subhanf
a Faculty of Public Health, Hasanuddin University, Indonesia
b Department of Environmental Health, Faculty of Public Health, Hasanuddin University, Indonesia
c Department of Occupational Health and Safety, Faculty of Public Health, Hasanuddin University, Indonesia
d Department of Marine Science, Faculty of Marine Science and Fisheries, Hasanuddin University, Indonesia
f Department of Public Health, Faculty of Public Health Dayanu Ikhsanuddin University, Baubau, Indonesia
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Tablas (2)
Table 1. Spearman test results for bioaerosol correlations of temperature, humidity, and lighting for measurements in the morning.
Table 2. Spearman test results for bioaerosol correlations of temperature, humidity, and lighting for midday measurements.
Mostrar másMostrar menos
Abstract
Objective

This research aims to determine the correlation of bioaerosol pollution with temperature, humidity, and lighting in the ICU for measurement in morning and midday.

Methods

The research was an observational analytic with a cross-sectional study design conducted in Dr. Wahidin Sudirohusodo hospital. The sample of the research consisted of 8 ICU rooms. The data were analyzed using the Spearman test.

Results

The total of bioaerosol in the morning ranged from 320–1885CFU/m3 and the total of bioaerosol in midday ranged from 366–1895CFU/m3. The result showed that the humidity factor correlated with the total of microbial (p=0.006) but the temperature (p=0.471) and lighting (p=0.232) did not correlate with the total of bioaerosol for morning measurement. While the temperature, humidity and lighting factors correlated with the total of bioaerosol (p=0.000) for midday measurement.

Conclusion

The quality of bioaerosol correlates with temperature, humidity, and lighting. For further improvement designing well-built HVAC.

Keywords:
Bioaerosol
Humidity
ICU
Lighting
Temperature

Artículo

Opciones para acceder a los textos completos de la publicación Enfermería Clínica
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Enfermería Clínica

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

Quizás le interese:
10.1016/j.enfcli.2019.10.113
No mostrar más