metricas
covid
Buscar en
Fisioterapia
Toda la web
Inicio Fisioterapia Fiabilidad intra e interevaluador de un sensor inercial para el rango de movimie...
Información de la revista
Vol. 41. Núm. 3.
Páginas 123-130 (mayo - junio 2019)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Visitas
46
Vol. 41. Núm. 3.
Páginas 123-130 (mayo - junio 2019)
Original
Fiabilidad intra e interevaluador de un sensor inercial para el rango de movimiento de la rodilla en sujetos asintomáticos
Intra- and inter-reliability of an inertial sensor for knee range of motion in asymptomatic subjects
Visitas
46
H. Beltran-Alacreua,b,c, G. Navarro-Fernandezc, J. San Juan-Burgueñoa, J.A. Gonzalez-Sancheza, S. Lerma-Laraa,b, O. Rodriguez-Lopezc,
Autor para correspondencia
oscarrl@irflasalle.es

Autor para correspondencia.
, D. Muñoz-Garcíaa,b
a Departamento de Fisioterapia, Centro Superior de Estudios Universitarios La Salle, Universidad Autónoma de Madrid, Madrid, España
b Grupo de investigación Motion in Brains, Instituto de Neurociencias y Ciencias del Movimiento, Centro Superior de Estudios Universitarios La Salle, Universidad Autónoma de Madrid, Madrid, España
c Unidad de Trastornos musculoesqueléticos, Instituto de Rehabilitación Funcional (IRF) La Salle, Madrid, España
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (3)
Mostrar másMostrar menos
Tablas (3)
Tabla 1. Datos demográficos. Estadísticos descriptivos
Tabla 2. Fiabilidad Intraevaluador
Tabla 3. Fiabilidad inter-evaluador
Mostrar másMostrar menos
Resumen
Introducción

La cuantificación del rango de movimiento de la rodilla es una medida clínicamente relevante en el ámbito sanitario, ya que su disminución puede alterar las actividades de la vida diaria. La obtención de una medida fiable del rango de movimiento nos permite valorar la eficacia de las intervenciones, así como la gravedad de la enfermedad. Por esto, el objetivo de este estudio fue conocer la fiabilidad intra e interevaluador de un protocolo para el rango de movimiento articular de la rodilla llevado a cabo con un sensor inercial en sujetos asintomáticos.

Métodos

Se midió el rango de movimiento de 32 rodillas en sujetos asintomáticos, se realizaron 2 sesiones de medición, una por evaluador, en el mismo día. En cada sesión se hicieron un total de 8 mediciones (2 medidas para flexión en decúbito supino, 2 medidas para extensión en decúbito supino, 2 medidas para flexión en bipedestación y 2 para la extensión en bipedestación).

Resultados

Para la fiabilidad interevaluador se consiguieron buenos resultados con un ICC superior a 0,79 para todos los movimientos. Los datos obtenidos para la fiabilidad intraevaluador en todos los movimientos fueron excelentes (ICC>0,88).

Conclusión

Este estudio obtuvo una excelente fiabilidad interevaluador e intraevaluador para los sujetos sanos midiendo con sensores inerciales.

Palabras clave:
Fiabilidad test-retest
Reproductibilidad de resultados
Acelerometría
Rango de movimiento
Rodilla
Abstract
Introduction

The quantification of knee range of motion is a clinically relevant measurement in the healthcare setting, as its decrease can alter activities of daily living. Collecting reliable measurements of the range of motion allows us to evaluate the reliability of interventions, or the severity of the pathology. The objective of this study was to obtain the intra- and inter- rater reliability of a protocol for the knee the range of joint motion, measured with an inertial sensor in asymptomatic subjects.

Methods

The range of motion of 32 asymptomatic knees was measured. Two measurement sessions were performed by two different evaluators. A total of 8 measurements were made in each session: 2 measurements for flexion in supine decubitus position, 2 measurements for extension in supine decubitus, 2 measurements for flexion in standing position and 2 measurements for extension in standing position.

Results

For inter-rater reliability, good results were achieved, with an ICC>0.79 for all movements. The obtained data for intra-rater reliability in all the movements was excellent, with an ICC>0.88.

Conclusion

This study obtained excellent inter-rater and intra-rater reliability for healthy subjects.

Keywords:
Test-retest reliability
Reproducibility of results
Accelerometry
Range of motion
Knee

Artículo

Opciones para acceder a los textos completos de la publicación Fisioterapia
Socio
Socios AEF

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Problemas con el acceso de socios AEF
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
E-mail
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Fisioterapia

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos