Hipertensión arterial ¿Mal control? Quizá no tan malo*
Hypertension poorly controlled? Perhaps not so poorly
Visitas
2194
J.A. Divisóna,
Autor para correspondencia
jdivisong@medynet.com

Correspondencia: C./ Cuenca, 8, 2.º G. 02002 Albacete.
, C. Sanchisb, L. Carriónc, L.M. Artigaod, J.A. Carbayoe, J. Massoff, E. López de Cocagg, J. López Abrildd, B. Rodríguez Pañoshh, D. Caldevillaii
a Centro de Salud Casas Ibáñez. Albacete
b Centro de Salud Algemesí. Valencia
c Centro de Salud Zona IV. Albacete
d Centro de Salud Zona III. Albacete
e Base Aérea de los Llanos. Albacete
f Centro de Salud Casas Juan Núñez. Albacete
g Centro de Salud Chinchilla. Albacete
h Hospital Perpetuo Socorro. Albacete
i Servicio de Urgencias. Hospital General Universitario. Albacete. Grupo de Estudio de Enfermedades Vasculares de Albacete (GEVA)
Ver más
Este artículo ha recibido
Información del artículo
Objetivo

Conocer el grado de control de hipertensos tratados, en consulta de enfermería y con automedidas domiciliarias.

Material y métodos

Estudio descriptivo realizado en Atención Primaria. Mediante muestreo aleatorio simple se seleccionó una muestra de 600 hipertensos tratados, citados en consulta programada de enfermería. A los que aceptaron se les hizo 6 medidas consecutivas de presión arterial en consulta de enfermería, en condiciones estandarizadas y con aparato electrónico automático y se les entrenó para que hicieran 24 automedidas domiciliarias durante un día. Se consideró buen control en consulta cuando la presión arterial era < 140/90 mmHg y en domicilio cuando era < 135/85 mmHg.

Resultados

Se midió la presión arterial en consulta de enfermería y domicilio a 583 pacientes (54,4 % mujeres) con una edad media de 62,9 (DE: 10,4) años. Los valores medios de presión arterial en consulta de enfermería fueron 139,3 (DE: 17,1) y 81,3 (DE: 9,4) mmHg para la sistólica y diastólica y con medidas domiciliarias 131,4 (DE: 15,7) y 78,7 (DE: 8,8) mmHg. El grado de control fue del 50,9 % en consulta de enfermería y del 55,4% con medidas domiciliarias. Se observaron grados de control distintos en los diferentes momentos del día en los que se realizó la automedida y el control mejoró, tanto en enfermería como en domicilio, al excluir las dos primeras medidas.

Discusión

Las medidas clínicas infraestimaron el grado de control de los hipertensos. Con automedida de la presión arterial domiciliaria el grado de control observado fue más elevado. Sería de interés estandarizar las condiciones de medida para tener una información más exacta del grado de control y hacer comparables los diferentes estudios epidemiológicos.

Palabras clave:
hipertensión arterial
control
enfermera
automedida domiciliaria
Objective

To estimate the control rate of hypertensive patients who were treated, in the nurse office and with home self-measurements.

Material and methods

Descriptive study developed in Primary Health Care. By means of a random sample, 600 hypertensive treated who go to the programmed nurse office, were selected. Those who agreed, their previously trained nurse, made them 6 arterial blood pressure consecutive measurements, in standardized conditions and with an electronic set, and these patients were trained to make 24 home self-measurements, with the same electronic set, in a day. Control office when < 140/90 mmHg and control at home when < 135/85 mmHg.

Results

583 patients (54.4% women) were measured blood pressure at nurse office and at home being mean age 62.9 (SD: 10.4) years old. Mean blood pressure values at nurse office were 139.3 (SD: 17.1) and 81.3 (SD: 9.4) mmHg for systolic and diastolic and with home selfmeasurements 131.4 (SD: 15.7) and 78.7 (SD: 8.8) mmHg. The control rate was 50.9% at nurse office and 55.4% with home self-measurements. Different control grades were observed during the different moments of the day when home self-measurements were made, and improved, both at nurse office and in home, on excluding the two first blood pressure measurements.

Discussion

Clinical measures understimates hypertension control rate. With home self-measurement the control rate is better. It would be interesting to standardize measure conditions to have a more exact control grade information and so make comparable the different epidemiological studies.

Key words:
hypertension
control
nurse
home self-measurement

Artículo

Opciones para acceder a los textos completos de la publicación Hipertensión y Riesgo Vascular
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Hipertensión y Riesgo Vascular

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos