metricas
covid
Buscar en
Revista Española de Medicina Nuclear e Imagen Molecular
Toda la web
Inicio Revista Española de Medicina Nuclear e Imagen Molecular Concordancia entre SPECT portátil y la gammagrafía convencional para detecció...
Información de la revista
Vol. 43. Núm. 2.
Páginas 79-83 (marzo - abril 2024)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Visitas
248
Vol. 43. Núm. 2.
Páginas 79-83 (marzo - abril 2024)
Original
Concordancia entre SPECT portátil y la gammagrafía convencional para detección de ganglio centinela en cáncer de mama
Concordance between freehand SPECT and conventional scintigraphy for sentinel lymph node detection in breast cancer
Visitas
248
Á. Esteban Hurtadoa,
Autor para correspondencia
angela_esteban@hotmail.es

Autor para correspondencia.
, J. Orozco Cortésa, P. Cárcamo Ibarrab, U. López Gonzálezc, Á. Badenes Romeroa, M.Á. Navas de la Cruza, C. Siscar Geloa, L. Casas Calabuiga, P. Abreu Sáncheza, T. Mut Dóleraa, D. Balaguer Muñoza, M.D. Reyes Ojedaa, C. Plancha Mansaneta, E. Caballero Calabuiga
a Servicio de Medicina Nuclear, Hospital Universitario Doctor Peset, Valencia, España
b Servicio de Medicina Nuclear, Hospital Clínico Universitario de Valencia, Valencia, España
c Servicio de Medicina Preventiva, Hospital Universitario Doctor Peset, Valencia, España
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (3)
Mostrar másMostrar menos
Tablas (5)
Tabla 1. Concordancia SPECT portátil vs. LG precoz
Tabla 2. Concordancia SPECT portátil vs. LG tardía
Tabla 3. Concordancia LG precoz vs. LG tardía
Tabla 4. Cálculo del índice kappa de Cohen mediante distintos métodos de ponderación entre las distintas pruebas
Tabla 5. Estudio de concordancia e índice Kappa para cada categoría
Mostrar másMostrar menos
Resumen
Introducción

La SPECT portátil puede ser una técnica de imagen útil para la planificación preoperatoria de la biopsia selectiva del ganglio centinela (BSGC) ya que permite la localización del ganglio centinela (GC) mediante imágenes tomográficas en 3D y en tiempo real y determina su profundidad, después de unos minutos de exploración.

El objetivo del estudio fue evaluar la correlación entre el número de GC detectados entre las imágenes de la SPECT portátil y la linfogammagrafía (LG).

Materiales y métodos

Cien pacientes con diagnóstico de cáncer de mama infiltrante y sin evidencia clínica de afectación ganglionar, se sometieron prospectivamente a una BSGC. El estudio preoperatorio incluyó imágenes de SPECT portátil a los 15 min tras la inyección y de LG a los 25 y 60-90 min (precoz y tardía). Se analizó el acuerdo observado y se realizó un estudio de concordancia entre el número de GC detectados con SPECT portátil y LG.

Resultados

El acuerdo observado en la detección de GC entre SPECT portátil y LG precoz fue del 72%; entre SPECT portátil y LG tardía del 85%, y entre la LG precoz y la tardía de un 87%. En el estudio de concordancia se registró una concordancia moderada entre la SPECT portátil y la LG precoz (coeficiente kappa: 0,42); una concordancia moderada-alta entre la SPECT portátil y la LG tardía (coeficiente kappa: 0,60), y una concordancia de moderada-alta entre la LG precoz y la tardía (coeficiente kappa: 0,70), sin diferencias significativas entre ellos (valor p=0,16).

Conclusión

La SPECT portátil presentó una concordancia moderada-alta con los estudios de imagen convencional y podría ser una alternativa válida para el estudio prequirúrgico de la BSGC en el cáncer de mama.

Palabras clave:
Cirugía radioguiada
SPECT portátil
Linfogammagrafía
Cáncer de mama
Biopsia selectiva de ganglio centinela
Abstract
Introduction

Freehand SPECT can be a useful imaging technique for preoperative planning of sentinel lymph node biopsy (SLNB) as it allows localization of the sentinel node by 3D and real-time tomographic imaging and determines its depth after a few minutes of scanning.

The aim of the study was to evaluate the correlation between the number of detected SNs between freehand SPECT images and lymphoscintigraphy (LS).

Materials and methods

One hundred patients with a diagnosis of invasive breast cancer and no clinical evidence of lymph node involvement prospectively underwent SLNB. The preoperative study included freehand SPECT imaging at 15min after injection and LS imaging at 25 and 60–90min after injection (early and late). The observed agreement was analyzed and a concordance study was performed between the number of SNs detected with freehand SPECT and LS.

Results

The observed agreement in the detection of SNs between freehand SPECT and early LS was 72%; between freehand SPECT and late LS was 85%; and between early and late LS was 87%. In the concordance study, there was moderate concordance between freehand SPECT and early LS (kappa coefficient: 0.42); moderate-high concordance between freehand SPECT and late LS (kappa coefficient: 0.60); and moderate-high concordance between early and late LS (kappa coefficient: 0.70), with no significant differences between them (p-value=0.16).

Conclusion

Freehand SPECT showed a moderate-high concordance with conventional imaging studies and could be a valid alternative for the presurgical study of SLNB in breast cancer.

Keywords:
Radioguided surgir
Freehand SPECT
Lymphoscintigraphy
Breast cancer
Sentinel lymph node biopsy

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Medicina Nuclear e Imagen Molecular
Socio
Si es usted socio de la Sociedad Española de Medicina Nuclear e Imagen Molecular (SEMNIM) puede acceder al texto completo de los contenidos de la Revista Española de Medicina Nuclear e Imagen Molecular desde los enlaces a la revista publicados en la web de la SEMNIN (enlace a https://semnim.es/iniciar-sesion/), previo inicio de sesión como socio. Si tiene problemas de acceso puede contactar con la Secretaría Técnica de la SEMNIM en el correo electrónico secretaria.tecnica@semnim.es o en el teléfono: + 34 619 594 780
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Medicina Nuclear e Imagen Molecular

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos