Correlación interobservadores en interpretación de SPECT de perfusión con 99mTc-sestamibi en infarto agudo de miocardio reperfundido
Interobserver correlation in the interpretation of 99mTc-sestamibi SPECT in reperfused acute myocardial infarction
Visitas
5135
T. Massardoa, H. Lavadosa, R. Jaimovicha, E. Herreraa, L. Quevedoa, L. Alfarob, V. Assefb, C. Colla, C. Velásquezb, ME. Pereirab, E. Oleab, JC. Quintanab
a Sección de Medicina Nuclear. Departamento de Medicina. Hospital Clínico Universidad de Chile. Chile.
b Medicina Nuclear. Departamento de Radiología. Pontificia Universidad Católica de Chile. Chile.
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Tablas (3)
Tabla 1. CONCORDANCIA DE DIVERSOS PARÁMETROS ENTRE CONSENSO DE ESPECIALISTAS Y OBSERVADORES EN ENTRENAMIENTO (1: MÁS EXPERIMENTADO; 5: MENOS EXPERIMENTADO)
Fig. 1. --Correlación del número de segmentos miocárdicos comprometidos inicialmente respecto a la fracción de eyección ventricular izquierda (FEVI) calculada con ventriculografía isotópica un mes tras el infarto agudo de miocardio. Coeficiente de correlación (r) = ­0,7296; p para pendiente < 0,0001 (60 puntos, mejor ajuste estándar, intervalo de confianza al 95 %).
Fig. 2. --Correlación entre la sumatoria de severidad del defecto a la semana del infarto agudo de miocardio reperfundido respecto a la fracción de eyección ventricular izquierda (FEVI) efectuada al mes. Coeficiente de correlación (r) = ­0,7378; p para pendiente < 0,0001 (60 puntos, mejor ajuste estándar, intervalo de confianza al 95 %).
Mostrar másMostrar menos
Introducción y objetivos. La interpretación de la tomografía de emisión de fotón único (SPECT) de perfusión miocárdica requiere conocer la reproducibilidad de la técnica. El objetivo fue analizar la correlación interobservadores de distinta experiencia en interpretación de SPECT en pacientes post-infarto agudo de miocardio (IAM) en un contexto de mejora de la calidad de nuestros centros. Métodos. Se incluyeron 60 casos (56 ± 11 años, 87 % hombres) con infarto transmural reciente sometidos a trombolisis exitosa. Una semana después del IAM se efectuó perfusión de reposo con 99mTc-sestamibi. Análisis. Semicuantitativo mediante lectura ciega por 2 especialistas independientes y 5 observadores utilizando 17 segmentos. La fracción de eyección ventricular izquierda (FEVI) promedio medida con ventriculografía isotópica al mes fue del 38 %. Resultados. En análisis consensuado, el promedio de segmentos comprometidos/paciente fue 9,3 ± 4 y la sumatoria de severidad 25 ± 13; los otros observadores variaron entre: 7 ± 3,7-9,4 ± 3,9 y 16,7 ± 9,7-24,6 ± 13, respectivamente, concordando con los especialistas entre 0,779 y 0,871 (kappa: 0,565-0,741). No hubo diferencia significativa en el 40 % de los análisis para el número de segmentos comprometidos y en el 60 % para intensidad, en observadores con mayor experiencia. La correlación con consenso para el número de segmentos varió entre 0,84 y 0,94, y para severidad entre 0,79 y 0,89. La asignación de arterias fue adecuada (r: 0,612-0,683 y kappas 0,629-0,656). La correlación de segmentos comprometidos y su severidad con la FEVI efectuada al mes del IAM fueron de 0,73 y 0,74, respectivamente. Conclusiones. Existió buena correlación en interpretación de SPECT, con mejor ajuste en observadores experimentados. Este ejercicio sirvió para mejorar habilidades de interpretación en cardiología.
Palabras clave:
infarto de miocardio, perfusión, SPECT, concordancia interobservador, entrenamiento
Introduction and objectives. The correct interpretation of myocardial perfusion single photon emission computed tomography (SPECT) requires knowledge of the technique reproducibility. The objective was analyze the interobserver correlation of different experience in the interpretation of myocardial perfusion SPECT in patients following acute myocardial infarction (AMI) in order to improve the quality of our site. Methods. Sixty cases (56 ± 11 years, 87 % men) with transmural AMI who had recently undergone successful thrombolysis were included. Resting perfusion with 99mTc-sestamibi was performed at one week post-AMI. Analysis. Semiquantitative interpretation using 17 segment-model by 2 independent specialists and 5 observers, was performed blindly. Left ventricular ejection fraction (LVEF) was measured with isotopic ventriculography one month after AMI, with a mean of 38 %. Results. Using independent and then agreed on perfusion analysis, average involved segments/patient was 9.3 ± 4 and the sum of severity 25 ± 13. Readings of other observers ranged from 7 ± 3.7 to 9.4 ± 3.9 and 16.7 ± 9.7 to 24.6 ± 13, respectively, consistent with the reading of the specialists of between 0.779-0.871 (kappa: 0.565-0.741). There was no significant difference when the number of segments were analyzed in 40 % of the cases and for intensity in 60 % of them in more experienced observers. Correlation with consensus reading for the number of segments ranged from 0.84 to 0.94 and for severity from 0.79 to 0.89. Identification of culprit arteries was acceptable, with r values between 0.612 and 0.683 and kappas between 0.629 and 0.656. Correlation of the number of involved segments and severity with LVEF performed one month after AMI was 0.73 and 0.74, respectively. Conclusions. There was good correlation in the interpretation of myocardial perfusion SPECT, with a significantly better fit in more experienced observers. This academic exercise was also helpful in improving our residents' skills in cardiology.
Keywords:
myocardial infarction, perfusion, SPECT, interobserver concordance, training

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Medicina Nuclear e Imagen Molecular
Socio
Si es usted socio de la Sociedad Española de Medicina Nuclear e Imagen Molecular (SEMNIM) puede acceder al texto completo de los contenidos de la Revista Española de Medicina Nuclear e Imagen Molecular desde los enlaces a la revista publicados en la web de la SEMNIN (enlace a https://semnim.es/iniciar-sesion/), previo inicio de sesión como socio. Si tiene problemas de acceso puede contactar con la Secretaría Técnica de la SEMNIM en el correo electrónico secretaria.tecnica@semnim.es o en el teléfono: + 34 619 594 780
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Medicina Nuclear e Imagen Molecular

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos