metricas
covid
Buscar en
Revista Española de Medicina Nuclear e Imagen Molecular
Toda la web
Inicio Revista Española de Medicina Nuclear e Imagen Molecular Estandarización de los protocolos de adquisición mediante PET/TC con 18F-Colin...
Información de la revista
Vol. 39. Núm. 4.
Páginas 204-211 (julio - agosto 2020)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Visitas
841
Vol. 39. Núm. 4.
Páginas 204-211 (julio - agosto 2020)
Original
Estandarización de los protocolos de adquisición mediante PET/TC con 18F-Colina en el cáncer de próstata
Standardization of acquisition protocols using PET/CT with 18F-Choline in prostate cancer
Visitas
841
J.R. Garcia
Autor para correspondencia
jrgarcia@cetir.es

Autor para correspondencia.
, M. Cozar, M. Soler, P. Bassa, E. Riera, M. Buxeda, E. Valls, J. Ferrer
Unidad PET CETIR ASCIRES Grupo biomédico, Esplugues de Llobregat, Barcelona, España
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (5)
Mostrar másMostrar menos
Tablas (3)
Tabla 1. Análisis por pacientes
Tabla 2. Análisis por lesiones
Tabla 3. Patrón metabólico de los depósitos de 18F-Colina
Mostrar másMostrar menos
Resumen
Introducción

Estandarizar los protocolos de adquisición de 18F-Colina PET/TC, que permitan evitar la interferencia urinaria, evaluar el mejor tiempo del estudio de cuerpo completo y valorar si la «doble fase» permite la diferenciación entre lesiones benignas frente a malignas.

Método

Estudio prospectivo que incluye 100 pacientes con cáncer de próstata: 31 estadificación y 69 recidiva bioquímica (32 posprostatectomía y 37 posradioterapia). Adquisición pélvica inmediatamente tras inyección de 18F-Colina y estudio de cuerpo completo, 1 y 2h p.i. Cálculo de media SUVmáx por territorios en todos los estudios secuenciales. Análisis de medias (χ2) y porcentaje de cambio del SUV (2/1h; 1h/0min). Patrón de dinámica metabólica: acumulativo frente a aclaramiento. Seguimiento tras tratamiento en todos los pacientes y de forma dirigida, cuando éticamente es posible.

Resultados

Cincuenta y tres focos prostáticos, en ninguna de las imágenes precoces actividad urinaria: Patrón acumulativo en 42, porcentaje de aumento: 0min/1h: +16,7% (X20,94); 1/2h: +10,0% (X20,83). Patrón aclaramiento en 11, porcentaje de reducción: 0min/1h: 21,4% (X20,91); 1/2h: −7,7% (X20,85), correspondiendo en 7 a estadificación y 4 a posradioterapia.

Todos los focos infradiafragmáticos (n: 24) mostraron dinámica acumulativa, porcentaje de aumento: +9,1% (χ20,97), todas ellas visibles en el primer estudio.

De los 12 focos supradiafragmáticos, 8 mostraron aclaramiento, porcentaje de reducción: −13,0% (χ2 0,95). Los otros 4 dinámica acumulativa, porcentaje de aumento: +13,0% (χ2 0,96), siendo valorados invasivamente.

Todos los focos óseos (n: 18) mostraron dinámica acumulativa, porcentaje de aumento: +17,1% (χ20,95), todas ellas visibles en el estudio 1h.

Conclusiones

En la valoración prostática la mejor técnica doble fase es 0min/1h. En la diferenciación de adenopatías supradiafragmáticas es aconsejable la técnica de doble fase: 1/2h. Para la infiltración infradiafragmática y ósea, ante hallazgos dudosos, las imágenes 2h aumentan la confianza diagnóstica.

Palabras clave:
Estandarización
PET/TC con 18F-Colina
Cáncer de próstata
Protocolos de adquisición
Abstract
Aim

To standardize acquisition protocols for 18F-Choline PET/CT to prevent from urine interference, to determine the best time point for the whole-body study, and to assess whether “dual point” acquisition allows for differentiating malignant vs. benign lesions.

Methods

One hundred consecutive patients with prostate cancer were prospectively studied. Immediately after 18F-Choline injection, a pelvis study was acquired, and a whole-body was subsequently obtained 1 and 2 hours p.i. Mean SUVmax was obtained in regions and for every sequential imaging. Mean analysis (χ2) and SUV percentage change (2/1 hours; 1 hours/0 min) were obtained. Metabolic pattern dynamics were assessed: accumulative vs. clearance. Patient follow-up after therapy and directed classification whenever ethically possible were performed.

Results

Fifty-three prostate foci, without disturbing urinary activity was ever found on early images. Accumulative pattern in 42, with percentage increase was: 0 min/1 hour: +16.7% (χ20.94); 1/2 hours: +10,0% (χ2 0.83). Clearance pattern in 11, with percentage decrease: 0 min/1 hour: −21.4% (χ20.91): −7.7% (χ20.85), corresponding in 7 to initial staging and in 4 post-radiotherapy biochemical recurrence.

Every infradiaphragmatic uptake (n: 24) showed accumulative pattern, with percentage increase of +9.1% (χ20.97), all of them depicted on early imaging.

As for 12 supradiaphragmantic uptake, 8 of them showed clearance pattern with percentage decrease: −13.0% (χ20.95). Accumulative pattern showed in 4 of them with percentage increase +13.0% (χ2 0.96), thus being assessed as invasive/malignant.

Every bone uptake (n: 18) showed accumulative pattern, with percentage increase: +17.1% (χ20.95), all of them depicted on 1 hour imaging.

Conclusions

As for prostate assessment is concerned, dual point at 0 min/1 hour proved to be the best procedure. As for supradiaphragmatic lymph-nodes detection, dual point with 1/2 hours performed best. As for infradiaphragmatic and bone involvement, as well as for inconclusive findings, the 2 hour imaging increased our diagnostic confidence.

Keywords:
Standardization
18F-Choline PET/TC
Prostate cancer: Acquisition protocols

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Medicina Nuclear e Imagen Molecular
Socio
Si es usted socio de la Sociedad Española de Medicina Nuclear e Imagen Molecular (SEMNIM) puede acceder al texto completo de los contenidos de la Revista Española de Medicina Nuclear e Imagen Molecular desde los enlaces a la revista publicados en la web de la SEMNIN (enlace a https://semnim.es/iniciar-sesion/), previo inicio de sesión como socio. Si tiene problemas de acceso puede contactar con la Secretaría Técnica de la SEMNIM en el correo electrónico secretaria.tecnica@semnim.es o en el teléfono: + 34 619 594 780
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Medicina Nuclear e Imagen Molecular

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos