Fusión de imágenes de gated-SPECT y angiotomografía computarizada en la enfermedad coronaria. Importancia de la correlación anatomicofuncional
Image fusion of gated-SPECT and CT angiography in coronary artery disease. Importance of anatomic-functional correlation
Visitas
8070
M.. Nazarena Pizzia, S.. Aguadé Bruixa,
Autor para correspondencia
saguade@vhebron.net

Autor para correspondencia. saguade@vhebron.net
, H.. Cuéllar Calabriab, V.. Aliagaa, J.. Candell Rieraa
a Unidad de Cardiología Nuclear, Hospital Universitari Vall d’Hebron, Barcelona, España
b Servicio de Radiología, Hospital Universitari Vall d’Hebron, Barcelona, España
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (6)
Mostrar másMostrar menos

Paciente de 77 años de edad ingresado por un síndrome coronario agudo sin elevación del segmento ST. Se estratificó su riesgo mediante gated-SPECT de perfusión miocárdica, evidenciándose una ligera isquemia inferior, por lo cual se optimizó el tratamiento médico y recibió el alta hospitalaria. El paciente continuó con disnea de esfuerzo, y se le realizó una angiotomografía computarizada coronaria que mostró lesiones intensas en la arteria coronaria derecha (CD) proximal. La fusión SPECT-tomografía computarizada correlacionó el defecto de perfusión miocárdica con la arteria descendente posterior proveniente de la arteria CD en un territorio de irrigación codominante. Posteriormente se indicó un cateterismo cardiaco para su tratamiento.

El uso actual de los estudios de fusión de imágenes se limita a pacientes en los cuales es difícil la asignación de un defecto de perfusión a una determinada arteria coronaria. En nuestro paciente, las imágenes de fusión contribuyeron a discernir la arteria responsable del territorio isquémico entre la arteria CD y la arteria circunfleja.

Palabras clave:
Cardiopatía isquémica
Gated-tomografía computarizada por emisión de fotones simples
Angiotomografía computarizada
Perfusión miocárdica
Fusión de imágenes

A 77-year old patient was admitted for acute coronary syndrome without ST elevation. His risk was stratified using the myocardial perfusion gated SPECT, mild inferior ischemia being observed. Thus, medical therapy was optimized and the patient was discharged. He continued with exertional dyspnea so a coronary CT angiography was performed. It revealed severe lesions in the proximal RCA. SPECT-CT fusion images correlated the myocardial perfusion defect with a posterior descending artery from the RCA, in a co-dominant coronary area. Subsequently, cardiac catheterism was indicated for his treatment.

The current use of image fusion studies is limited to patients in whom it is difficult to attribute a perfusion defect to a specific coronary artery. In our patient, the fusion images helped to distinguish between the RCA and the circumflex artery as the culprit artery of ischemia.

Keywords:
Ischemic heart disease
Gated-SPECT
Angio-CT
Myocardial perfusion
Image fusion

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Medicina Nuclear e Imagen Molecular
Socio
Si es usted socio de la Sociedad Española de Medicina Nuclear e Imagen Molecular (SEMNIM) puede acceder al texto completo de los contenidos de la Revista Española de Medicina Nuclear e Imagen Molecular desde los enlaces a la revista publicados en la web de la SEMNIN (enlace a https://semnim.es/iniciar-sesion/), previo inicio de sesión como socio. Si tiene problemas de acceso puede contactar con la Secretaría Técnica de la SEMNIM en el correo electrónico secretaria.tecnica@semnim.es o en el teléfono: + 34 619 594 780
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Medicina Nuclear e Imagen Molecular

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos