metricas
covid
Buscar en
Revista Española de Medicina Nuclear e Imagen Molecular
Toda la web
Inicio Revista Española de Medicina Nuclear e Imagen Molecular Influencia de diferentes observadores sobre la interpretación de la gammagrafí...
Información de la revista
Vol. 21. Núm. 2.
Páginas 93-98 (marzo 2002)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Vol. 21. Núm. 2.
Páginas 93-98 (marzo 2002)
Influencia de diferentes observadores sobre la interpretación de la gammagrafía de perfusión pulmonar
Effect of different observers over lung scintigraphic interpretation
Visitas
2578
J R. Infantea, M. Torres-Avisbala, F M. Gonzáleza, J A. Vallejoa, C. Pachecoa, A. Valverdea, C. Ariasa, J M. Latrea
a Servicio de Medicina Nuclear, Hospital Universitario Reina Sofía, Córdoba.
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Tablas (4)
Fig. 1. --Tablas A y B; concordancias con mayor índice Kappa (especialista B - residente 1) y menor índice Kappa (especialista E - residente 2). Tablas C y D; comparaciones de las dos interpretaciones realizadas por un mismo facultativo (residente 1 y médico especialista B). N: número de casos.
Mostrar másMostrar menos
Objetivo: El acuerdo en la interpretación de las imágenes gammagráficas de perfusión pulmonar en el diagnóstico del tromboembolismo pulmonar (TEP) en ocasiones no es el más adecuado. El objetivo de este estudio fue evaluar el grado de concordancia de ocho médicos en la interpretación de estos estudios. Material y Métodos: Se consideraron 180 estudios remitidos a nuestro servicio entre abril de 1998 y septiembre de 1999 para la realización de una gammagrafía de perfusión pulmonar por sospecha de TEP. Tras la inyección intravenosa de entre 111 y 148 MBq de 99mTc-macroagregados de albúmina, se obtuvieron las seis proyecciones rutinarias. El grupo de médicos incluía cinco especialistas en Medicina Nuclear y tres residentes de la especialidad que independientemente interpretaron las imágenes gammagráficas como de alta, intermedia o baja probabilidad de TEP. Posteriormente se realizó una interpretación de consenso. Se utilizó el índice estadístico Kappa para evaluar el grado de concordancia entre las interpretaciones individuales. Resultados: El valor medio ± error estándar de los diferentes índices Kappa hallados fue de 0,58 ± 0,02, con un valor máximo y mínimo de 0,76 y 0,27, respectivamente. La variabilidad interobservador en la interpretación de las imágenes fue mayor de la esperada. Excepto en dos médicos, los estudios catalogados como de probabilidad baja y alta mostraron pocas discrepancias, mientras que aquellos considerados como de probabilidad intermedia presentaron las mayores variaciones interobservador. Conclusión: El estudio pone de manifiesto la importancia de aplicar criterios lo más uniformes posibles en la valoración de la gammagrafía de perfusión pulmonar.
Palabras clave:
Gammagrafía pulmonar
Interpretación
Acuerdo
Índice Kappa
Aim: The agreement in the interpretation of the scintigraphic images of pulmonary perfusion in the diagnosis of pulmonary tromboembolism (TEP) is not always the most adequate. The purpose of this study was to evaluate the degree of agreement by eight observers in the interpretation of these studies. Material and Methods: The study population consisted of 180 studies with clinically suspected pulmonary embolism referred to our department for scintigraphic perfusion imaging from April 98 to September 99. The patients received an intravenous injection of 111-148 MBq (3-4 mCi) of 99mTc-macroaggregated albumin whereas the images were obtained in the six routine projections. The observers consisted of five nuclear medicine physicians and three residents who independently reviewed the scintigrams (low, intermediate and high probability). In a second step, the physicians performed consensus interpretations. The Kappa statistics was used to evaluate the degree of agreement between individual observer interpretations beyond that expected by chance alone. Results: The mean value ± SEM for Kappa index was 0.58 ± 0.02, with maximum and minimum values of 0.76 and 0.27 respectively. The interobserver variability was greater than expected. Except in two observers scans in the interpretation of images in the low and high categories showed minor discrepancies, whereas scans in intermediate probability showed the most important interobserver variations. Conclusion: The study manifests the importance of a uniform criteria in lung scintigraphic interpretation.
Keywords:
Lung scintigraphy
Interpretation
Agreement
Kappa index

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Medicina Nuclear e Imagen Molecular
Socio
Si es usted socio de la Sociedad Española de Medicina Nuclear e Imagen Molecular (SEMNIM) puede acceder al texto completo de los contenidos de la Revista Española de Medicina Nuclear e Imagen Molecular desde los enlaces a la revista publicados en la web de la SEMNIN (enlace a https://semnim.es/iniciar-sesion/), previo inicio de sesión como socio. Si tiene problemas de acceso puede contactar con la Secretaría Técnica de la SEMNIM en el correo electrónico secretaria.tecnica@semnim.es o en el teléfono: + 34 619 594 780
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Medicina Nuclear e Imagen Molecular

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos