metricas
covid
Buscar en
Revista Española de Medicina Nuclear e Imagen Molecular
Toda la web
Inicio Revista Española de Medicina Nuclear e Imagen Molecular Terapia de ablación con yodo radiactivo de baja dosis (1,11GBq) para el cáncer...
Información de la revista
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Visitas
7
Original
Disponible online el 24 de octubre de 2024
Terapia de ablación con yodo radiactivo de baja dosis (1,11GBq) para el cáncer de tiroides diferenciado en el oeste de Turquía
Low dose radioactive iodine ablation therapy (1.11GBq) for differentiated thyroid cancer in western Turkey
Visitas
7
B. Karaşah Erkeka,
Autor para correspondencia
burcin.karasah@ege.edu.tr

Autor para correspondencia.
, H. Sarıyıldız Gümüşgözb, A. Orala, B. Yazıcıa, A. Akgüna
a Nuclear Medicine Department, Ege University Faculty of Medicine, İzmir, Turquía
b Nuclear Medicine Department, Sakarya University Training and Research Hospital, Sakarya, Turquía
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Tablas (4)
Tabla 1. TSH, Tg, valores de anticuerpos anti-Tg (media, min-max) obtenido en el grupo de pacientes en tres puntos de evolución
Tabla 2. Análisis de la curva de características operativas del receptor (ROC) de los niveles de Tg de ablación evocada para definir el valor de corte en caso de que no se logre una ablación exitosa en el subgrupo
Tabla 3. Análisis univariado de los factores que influyen en el éxito de la ablación
Tabla 4. Análisis multivariado de los factores que influyen en el éxito de la ablación
Mostrar másMostrar menos
Resumen
Objetivo

La terapia de ablación se emplea en casos de cáncer diferenciado de tiroides (CDT) de bajo riesgo para facilitar el seguimiento del paciente al reducir los niveles de tiroglobulina (Tg) a niveles medibles inferiores después de la cirugía mediante la eliminación del tejido tiroideo residual. Sin embargo, todavía existe incertidumbre sobre la dosis mínima de actividad necesaria para una ablación eficaz. Optar por dosis bajas de [131I]NaI para la ablación ofrece varias ventajas tanto para los pacientes como para los servicios sanitarios. Particularmente en este grupo de tumores con una alta esperanza de vida (aproximadamente del 90 al 95% a los 10años), el tratamiento con [131I]NaI no debería suponer un riesgo para la vida postratamiento del paciente y no debería comprometer su calidad de vida. Sin embargo, existe la necesidad de una identificación bien definida de los factores que predicen una ablación exitosa.

Métodos

Se revisaron retrospectivamente los datos clínicos, los hallazgos de laboratorio y las pruebas de imagen de 287 pacientes con terapia de ablación con dosis bajas de 1.110MBq (30mCi) de [131I]NaI para el CDT. Las imágenes posteriores a la ablación y los hallazgos de laboratorio clasificaron el éxito/fracaso de la ablación. El grupo de ablación exitosa se determinó de acuerdo con los criterios de respuesta excelente descritos en los criterios de la ATA. Se analizaron las relaciones entre los hallazgos clínicos y patológicos, las variables bioquímicas comunes y el fracaso del tratamiento.

Resultados

Se logró una excelente respuesta en el 77% de todo el grupo según criterios ATA postablación. El sexo masculino y los niveles altos de Tg el día de la ablación (límite de Tg: 10ng/ml y 5,35ng/ml) se asociaron con una ablación fallida.

Conclusiones

Nuestros resultados indican que una dosis de ablación de 1.110MBq (30mCi) es suficiente para lograr una respuesta excelente en la mayoría de los casos de CDT de bajo riesgo entre 6 y 12meses después. Al seleccionar la dosis para la ablación, además de los marcadores histológicos mencionados en las guías y la edad, observamos que los valores de Tg estimulados y el sexo pueden ser importantes para predecir el éxito de la ablación.

Palabras clave:
Cáncer de tiroides
Terapia 131-I
Ablación remanente
Tiroglobulina
Abstract
Objective

Ablation therapy is employed in low-risk differentiated thyroid cancer (DTC) cases to facilitate patient monitoring by reducing thyroglobulin (Tg) levels to measurable levels below after surgery by eliminating residual thyroid tissue. However, there is still uncertainty about the minimum activity dose required for effective ablation. Opting for low-dose [131I]NaI for ablation offers several advantages for both patients and healthcare services. Particularly in this tumor group with a high life expectancy (approximately 90-95% at 10years) [131I]NaI treatment should not pose a risk to the patient's post-treatment life and should not compromise their quality of life. However, there is a need for a well-defined identification of factors predicting successful ablation.

Methods

Clinical data, laboratory findings, and imaging tests of 287 patients with low-dose 1110MBq (30mCi) [131I]NaI ablation therapy for DTC were retrospectively reviewed. Post-ablation imaging and laboratory findings categorized ablation success/failure. The successful ablation group was determined according to the excellent response criteria outlined in ATA criteria. Relationships between clinical, pathological findings, biochemical common variables, and treatment failure were analyzed.

Results

An excellent response was achieved in 77% of the entire group according to ATA criteria post-ablation. Male gender and high Tg levels on the day of ablation (Tg cut-off: 10ng/ml and 5.35ng/ml) were associated with unsuccessful ablation.

Conclusions

Our results indicate that a 1110 MBq (30mCi) ablation dose is sufficient to achieve an excellent response in most low-risk DTC cases 6-12 onths later. When selecting the dose for ablation, besides the histological markers mentioned in guidelines and age, we observed that stimulated Tg values and gender may be important in predicting ablation success.

Keywords:
Thyroid cancer
131-I therapy
Remnant ablation
Thyroglobulin

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Medicina Nuclear e Imagen Molecular
Socio
Si es usted socio de la Sociedad Española de Medicina Nuclear e Imagen Molecular (SEMNIM) puede acceder al texto completo de los contenidos de la Revista Española de Medicina Nuclear e Imagen Molecular desde los enlaces a la revista publicados en la web de la SEMNIN (enlace a https://semnim.es/iniciar-sesion/), previo inicio de sesión como socio. Si tiene problemas de acceso puede contactar con la Secretaría Técnica de la SEMNIM en el correo electrónico secretaria.tecnica@semnim.es o en el teléfono: + 34 619 594 780
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Medicina Nuclear e Imagen Molecular

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

Quizás le interese:
10.1016/j.remn.2023.02.002
No mostrar más