metricas
covid
Buscar en
Revista Española de Medicina Nuclear e Imagen Molecular
Toda la web
Inicio Revista Española de Medicina Nuclear e Imagen Molecular Encefalitis límbica asociada a anti-Caspr2: contribución del análisis visual ...
Información de la revista
Vol. 39. Núm. 2.
Páginas 92-95 (marzo - abril 2020)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Visitas
1642
Vol. 39. Núm. 2.
Páginas 92-95 (marzo - abril 2020)
Nota Clínica
Encefalitis límbica asociada a anti-Caspr2: contribución del análisis visual ayudado de las imágenes PET con 18F-FDG mediante comparación con una base de datos de normalidad
Caspr2 antibody-associated limbic encephalitis: contribution of visual aided analysis of 18F-FDG PET images using normal database comparison
Visitas
1642
Liset Sánchez-Ordúza,c, Jaime Gállego Pérez-Larrayab, Fabiana Grisantic, María Centenob, Javier Arbizuc,
Autor para correspondencia
jarbizu@unav.es

Autor para correspondencia.
a SPECT Medicina Nuclear S.A.S, UNAB, Bucaramanga, Colombia
b Departamento de Neurología, Clínica Universidad de Navarra, Universidad de Navarra, Pamplona, Navarra, España
c Departamento de Medicina Nuclear, Clínica Universidad de Navarra, Universidad de Navarra, Pamplona, Navarra, España
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (2)
Tablas (1)
Tabla 1. Características de los estudios PET-FDG en pacientes con encefalitis límbica con anticuerpos Caspr2 positivos publicados en la literatura
Resumen

Un inicio temprano de la inmunoterapia es fundamental para mejorar el pronóstico de los pacientes con encefalitis aguda de origen autoinmune (EAI). Se ha propuesto un nuevo abordaje clínico para el diagnóstico temprano basado en aspectos clínicos y pruebas complementarias, pero estas pueden tener una sensibilidad limitada principalmente en las primeras semanas. Mientras que las formas más comunes de EAI (anti-LGI-1 y anti-NMDAR), muestran frecuentemente patrones de PET con 18Flúor-fluordeoxiglucosa (PET-FDG) consistentes, las anti-Caspr2 son menos frecuentes y los patrones de PET-FDG no están establecidos. En nuestra experiencia la PET-FDG en la EAI anti-Caspr2 presenta un hipermetabolismo temporal medial y un déficit difuso cortical, incluso con pruebas complementarias negativas. No obstante, es necesaria la estandarización del análisis de las imágenes PET mediante métodos basados en vóxeles con comparación con bases de datos de normalidad para definir con claridad las áreas de metabolismo alterado que pueden pasar desapercibidas al análisis visual.

Palabras clave:
Encefalitis límbica
Encefalitis autoinmune
Caspr2
18F-FDG PET/TC
Abstract

Early immunotherapy is of paramount importance for a positive outcome in patients suffering acute encephalitis of autoimmune origin (AIE). A new approach for early diagnosis based on clinical presentation and complementary tests has been proposed, but not all these tests show positive findings in the first weeks. While common forms of AIE (anti-LGI-1 and anti-NMDAR antibodies) exhibit consistent 18Fluor-fluorodeoxiglucose (FDG-PET) patterns in many cases, the anti-Caspr2 form of AIE is infrequent and FDG-PET patterns have not been well characterized. In our experience, FDG-PET in anti-Caspr2 limbic encephalitis shows medial temporal hypermetabolism and diffuse cortical hypometabolism, even in the absence of findings in these tests. However, it is necessary to standardize PET image analysis by means of visual and voxel-based methods compared to normal databases to define the areas of pathological metabolism that may go unnoticed when using visual analysis exclusively.

Keywords:
Limbic encephalitis
autoimmune encephalitis
Caspr2
18F-FDG PET/CT

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Medicina Nuclear e Imagen Molecular
Socio
Si es usted socio de la Sociedad Española de Medicina Nuclear e Imagen Molecular (SEMNIM) puede acceder al texto completo de los contenidos de la Revista Española de Medicina Nuclear e Imagen Molecular desde los enlaces a la revista publicados en la web de la SEMNIN (enlace a https://semnim.es/iniciar-sesion/), previo inicio de sesión como socio. Si tiene problemas de acceso puede contactar con la Secretaría Técnica de la SEMNIM en el correo electrónico secretaria.tecnica@semnim.es o en el teléfono: + 34 619 594 780
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Medicina Nuclear e Imagen Molecular

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos