metricas
covid
Buscar en
Revista Española de Medicina Nuclear e Imagen Molecular
Toda la web
Inicio Revista Española de Medicina Nuclear e Imagen Molecular Utilidad de la PET con 11C-metionina en la diferenciación precoz entre recurren...
Información de la revista
Vol. 36. Núm. 2.
Páginas 85-90 (marzo - abril 2017)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Visitas
585
Vol. 36. Núm. 2.
Páginas 85-90 (marzo - abril 2017)
Original
Utilidad de la PET con 11C-metionina en la diferenciación precoz entre recurrencia tumoral y radionecrosis de pacientes tratados de glioma de alto grado con RM indeterminada
The value of 11C-methionine PET in the early differentiation between tumour recurrence and radionecrosis in patients treated for a high-grade glioma and indeterminate MRI
Visitas
585
J.R. Garcia
Autor para correspondencia
jrgarcia@cetir.es

Autor para correspondencia.
, M. Cozar, M. Baquero, J.M. Fernández Barrionuevo, A. Jaramillo, J. Rubio, G. Maida, M. Soler, E. Riera
CETIR Unidad PET, CETIR-ERESA, Esplugues, Barcelona, España
Este artículo ha recibido
Disponible módulo formativo: Unidad 2. Saber más
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (3)
Mostrar másMostrar menos
Tablas (1)
Tabla 1. Características de los 30 pacientes
Resumen
Objetivo

Valorar la contribución de la PET con 11C-metionina en la diferenciación precoz entre recurrencia tumoral y radionecrosis en pacientes tratados de gliomas de alto grado.

Método

Treinta pacientes tratados de glioma (grado iii/iv) con cirugía/radioterapia/quimioterapia (5-18 meses) con RM indeterminada.

A todos se les realizó estudio de PET con 11C-metionina (<15 días tras RM) con análisis visual (grado de intensidad y morfología de captación), cuantificación (relación SUV máximo lesión/SUV medio fondo) y corregistro PET/RM (3D-Flair).

El manejo de los pacientes se decidió en el comité de neurooncología: seguimiento clínico-imagen, tratamiento de segunda línea o cirugía.

Resultados

Veintitrés estudios de PET con 11C-metionina fueron visualmente positivos. La morfología fue: 15 focales, 4 difusos y 4 anulares.

Tres de los focales fueron resecados (AP+). En 16 se realizó terapia de segunda línea (11 respuesta, 5 progresión). En los 4 de morfología anular se decidió seguimiento, con progresión en 2 (verdaderos positivos) y libres de enfermedad en 2 (6 y 7 meses después) (falsos positivos).

Siete estudios de PET con 11C-metionina fueron visualmente negativos, todos ellos libres de enfermedad (3-12 meses).

La relación SUV lesión/fondo en la recurrencia tumoral fue de 2,79±1,35 mientras que en la radionecrosis fue de 1,53±0,39 (p<0,05).

Con umbral de corte SUV lesión/fondo de 2,35 se obtuvo una sensibilidad y especificidad del 90,5 y 100%.

Conclusión

La valoración de la PET con 11C-metionina, con análisis visual, cuantitativo y corregistro PET/RM muestra un papel complementario en los pacientes con RM no concluyente, permitiendo una diferenciación precoz entre recurrencia tumoral y radionecrosis, que ayuda a la individualización de la terapia.

Palabras clave:
PET con 11C-metionina
Glioma
Recurrencia tumoral
Radionecrosis
RM
Abstract
Objective

To evaluate the contribution of 11C-Methionine PET in the early differentiation between tumour recurrence and radionecrosis in patients treated for a high grade glioma.

Method

The study included 30 patients with glioma (III/IV grade) treated with surgery/radiotherapy/chemotherapy (5-8 months) and with an indeterminate MRI.

All patients underwent a 11C-Methione PET (within 15 days of MRI) and studies were visually analysed (intensity and morphology of uptake), quantified (SUV max/SUV mean background), and coregistered to MRI (3D-Flair).

Patient management was decided by the neuro-oncology committee to clinical and imaging follow-up, second-line treatment, or surgery.

Results

There were 23 11C-Methionine PET studies visually positive. Morphology of uptake was focal in 15, diffuse in 4, and ring-shaped in 4.

Three out of the focal uptake cases underwent resection (Histopathology +). Sixteen underwent second-line therapy (11 responded; 5 progressed). The 4 cases with ring-shaped uptake were followed-up, and progression was found in 2 (true-positive), and disease-free in 2 (follow-up of 6 and 7 months, respectively) (false-positive).

Seven out of 11C-Methionine studies PET were visually negative, and all of them were disease-free (follow-up of 3-12 months).

SUV lesion/background was 2.79±1.35 in tumour recurrence, and 1.53±0.39 in radionecrosis (P<.05).

Taking into account a SUV lesion/background threshold of 2.35, the sensitivity and specificity values were 90.5% and 100%, respectively.

Conclusion

Visual analysis, quantitative and PET/MRI coregistration of 11C-Methionine PET showed their complementary role in patients with indeterminate MRI results, thus allowing early differentiation between tumour recurrence and radionecrosis, and helping in the individual therapy approach.

Keywords:
11C-Methionine PET
Glioma
Tumour recurrence
Radionecrosis
MRI

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Medicina Nuclear e Imagen Molecular
Socio
Si es usted socio de la Sociedad Española de Medicina Nuclear e Imagen Molecular (SEMNIM) puede acceder al texto completo de los contenidos de la Revista Española de Medicina Nuclear e Imagen Molecular desde los enlaces a la revista publicados en la web de la SEMNIN (enlace a https://semnim.es/iniciar-sesion/), previo inicio de sesión como socio. Si tiene problemas de acceso puede contactar con la Secretaría Técnica de la SEMNIM en el correo electrónico secretaria.tecnica@semnim.es o en el teléfono: + 34 619 594 780
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Medicina Nuclear e Imagen Molecular

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos