covid
Buscar en
Revista Portuguesa de Estomatologia, Medicina Dentária e Cirurgia Maxilofacial
Toda la web
Inicio Revista Portuguesa de Estomatologia, Medicina Dentária e Cirurgia Maxilofacial Análise do Desgaste de Attachments com Microscopia Electrónica de Varrimento
Información de la revista
Vol. 49. Núm. 1.
Páginas 13-18 (enero - marzo 2008)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Vol. 49. Núm. 1.
Páginas 13-18 (enero - marzo 2008)
Investigação
Open Access
Análise do Desgaste de Attachments com Microscopia Electrónica de Varrimento
Visitas
3303
António Correia Pinto*, José Manuel Mendes*, António Ferreira Angeja**, José Alberto Coelho***
* Médico Dentista, Professor Auxiliar do ISCSN
** Médico Dentista, Assistente do ISCSN
*** Médico Dentista, Assistente estagiário do ISCSN
Este artículo ha recibido

Under a Creative Commons license
Información del artículo
Resumen
Bibliografía
Descargar PDF
Estadísticas
Resumo
Objectivos

Este estudo teve como objectivo verificar e comparar qualitativamente, o desgaste provocado por atrito entre diferentes attachments de precisão, com a utilização de três tipos de ligas metálicas diferentes.

Materiais e Métodos

Neste estudo os attachments utilizados foram, o ANC94 L 110®, o Klinat L 90® e o ARS 88®, com fêmeas fundidas nas ligas Degupal G® (ouro-paládio), Ugirex C® (cromo-cobalto) e Rexilium III® (cromo-niquel). Todos os attachments foram submetidos a 4400 ciclos de inserção-desinserção, numa máquina de simulação de fadiga, debaixo dum jacto continuo de água bidestilada. Foram analisados em microscopia electrónica de varrimento na sua fase inicial, e após 4400 ciclos de inserção /desinserção.

Resultados

Oexame realizado nas superfícies das peças dos attachments com o microscópio electrónico de varrimento de superfície revelou um desgaste, arrastamento ou esmagamento, mais ou menos evidente, em todos os attachments observados. Nas fêmeas existiam sinais de desgaste nas superfícies de atrito, que eram evidentes em todos os tipos de attachments e tipos de ligas utilizadas. Em relação aos machos, também eram evidentes os sinais de desgaste com o aparecimento de perdas de material, arrastamentos de metal e sulcos mais ou menos profundos

Conclusões

Não se verificaram diferenças significativas no desgaste observado nas superfícies, nem em relação ao tipo de liga utilizada, nem aos componentes dos três attachments diferentes utilizados.

Palavras-Chave:
Microscópio electrónico de varrimento
Attachment
Abstract
Objectives

The main objectives of this study were the verification and qualitative comparative analysis of superficial wear, resultant of attrition between different precision attachments and distinct metal alloys.

Material and methods

Three types of attachments (ANC94 L 110®, Klinat L 90® and ARS 88®) with matrix fused in palladium- gold metal alloy (Degupal G®), two metal bases, chromo-cobalt (Ugirex C®) and chromo-nickel (Rexilium III®), where used. All attachments where submitted to 4400 insertion/disensertion cycles in a stress simulator, under continuous bidistilled water jet.

Results

Superficial electronic microscope (SEM) scanning analysis of the attachment surfaces, revealed signs of compression, scrapping and erosion, to some degree, in all observed samples. Signs of superficial wear were observed on all surfaces subject to attrition, independent of types of attachment and alloys utilized. As to the patrix, evident signs of superficial wear including scrapping, more or less deep grooving as well as material loss, where observed.

Conclusions

No significant differences in degree of superficial wear were observed, either in relation to type of alloy or components of the three types of attachments under study.

Key-words:
Scanning electronic microscope
Attachment
El Texto completo está disponible en PDF
Bibliografia
[1.]
N.M. Mazurat, R.D. Mazurat.
Discuss before fabricating: communicating the realities of partial denture therapy.
J Can Dent Assoc, 69 (2003), pp. 90-94
[2.]
J.C. Davenport, R.M. Basker, J.R. Heath, J.P. Ralph, P.O. Glantz.
Retention.
Br Dent J, 189 (2000), pp. 646-657
[3.]
J.C. Davenport, R.M. Basker, J.R. Heath, J.P. Ralph, P.O. Glantz, P. Hammond.
Connectors.
Br Dent J, 190 (2001), pp. 184-191
[4.]
W.M. Sadig, A.T. Idowu.
Removable partial denture design: A study of a selected population in Saudi Arabia.
J Contemp Dent Pract, 3 (2002), pp. 1-11
[5.]
O.F. Benatti, W.G. Miranda Jr., A. Muench.
In vitro and in vivo corrosion evaluation of nickel-chromium and copper-aluminum-based alloys.
J Prosthet Dent, 84 (2000), pp. 360-363
[6.]
H. Weber, G. Frank.
Spark erosion procedure: a method for extensive combined fixed and removable prosthodontics care.
J Prosthet Dent, 69 (1993), pp. 222-227
[7.]
S.K. Nelson, J.C. Wataha, P.E. Lockwood.
Accelerated toxicity testing of casting alloys and reduction of intraoral release of elements.
J Prosthet Dent, 81 (1999), pp. 715-720
[8.]
J.C. Wataha.
Alloys for prosthodontic restorations.
J Prosthet Dent, 87 (2002), pp. 351-363
[9.]
T.J. Lindquist, C.M. Stanford.
Development and application of a new abrasion testing device.
J Prosthet Dent, 84 (2000), pp. 635-641
[10.]
C.E. Besimo, A. Guarneri.
In vitro retention force changes of prefabricated attachments for overdentures.
J Oral Rehabil, 30 (2003), pp. 671-678
[11.]
M.G. Wichmann, W. Kuntze.
Wear behaviour of precision attachments.
Int J Prosthodont, 12 (1999), pp. 409-414
[12.]
O. Fromentin, B. Picard, B. Tavernier.
In vitro study of the retention and mechanical fatigue behaviour of four implant overdenture stud-type attachments.
Pract Periodont Aesthet Dent, 11 (1999), pp. 391-397
[13.]
B.L. Stewart, R.O. Edwards.
Retention and wear of precision-type attachments.
J Prosthet Dent, 49 (1983), pp. 28-34
[14.]
J. Setz, S.H. Lee, E. Engel.
Retention of prefabricated attachments for implant stabilized overdentures in the edentulous mandible: An in vitro study.
J Prosthet Dent, 80 (1998), pp. 323-329
[15.]
J.I. Gamborena, L.R. Hazelton, D. NaBadalung, J. Brudvik.
Retention of ERA direct overdenture attachments before and after fatigue loading.
Int J Prosthodont, 10 (1997), pp. 123-130

(Pinto AC, Mendes JM, Angeja AF, Coelho JA. Análise do Desgaste de Attachments com Microscopia Electrónica de Varrimento. Rev Port Estomatol Cir Maxilofac 2008;49:13–18)

Copyright © 2008. Sociedade Portuguesa de Estomatologia e Medicina Dentária
Descargar PDF
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos