metricas
covid
Buscar en
Acta Colombiana de Cuidado Intensivo
Toda la web
Inicio Acta Colombiana de Cuidado Intensivo Ultrasonido diafragmático como predictor de extubación en paciente crítico: r...
Journal Information
Vol. 22. Issue 1.
Pages 35-43 (January - March 2022)
Share
Share
Download PDF
More article options
Visits
1036
Vol. 22. Issue 1.
Pages 35-43 (January - March 2022)
REVISIÓN
Ultrasonido diafragmático como predictor de extubación en paciente crítico: revisión exploratoria
Diaphragmatic ultrasound as an extubation predictor in critical patients: Scoping review
Visits
1036
Andrés Fabricio Caballero-Lozadaa,b,
Corresponding author
andres.caballero@correounivalle.edu.co

Autor para correspondencia.
, Favio Ernesto Pabón Muñozb, Jenny Marcela Arias Campoc, Carolina Zorrilla Vacaa, Esther Cecilia Wilches Lunac
a Departamento de Anestesiología y reanimación, Hospital Universitario del Valle, Universidad del Valle, Cali, Colombia
b Departamento de Anestesiología, Facultad de Salud, Universidad del Valle, Cali, Colombia
c Escuela de Rehabilitación Humana, Facultad de Salud, Universidad del Valle, Cali, Colombia
This item has received
Article information
Abstract
Full Text
Bibliography
Download PDF
Statistics
Figures (4)
Show moreShow less
Tables (2)
Tabla 1. Características de estudios incluidos
Tabla 2. Valores de excursión diafragmática y valores de engrosamiento diafragmático
Show moreShow less
Resumen
Propósito de la revisión

El objetivo de esta revisión exploratoria fue aportar evidencia sobre el uso de la ultrasonografía en la medición diafragmática como predictor de extubación en el paciente crítico.

Fuente de obtención de datos

Dos revisores independientes realizaron la búsqueda sistemática de artículos en la base de datos OVID, MEDLINE, Cochrane, Embase y Google Scholar.

Selección de estudios

Se incluyeron estudios originales observacionales prospectivos o retrospectivos, ensayos clínicos y estudios de revisión. Los resultados iniciales de la búsqueda arrojaron un total de 2086 estudios. Tras selección manual de acuerdo con los criterios de inclusión se obtuvieron 10 artículos.

Extracción y síntesis de datos

Los resultados mostraron que las variables de medición para explorar el diafragma se describen en dos ventanas por US, las cuales son reproducibles y se realizan tanto en la ventana hepática como en la ventana esplénica. Además, se encontró que para la medición de la fracción de engrosamiento se utiliza una sonda lineal de alta frecuencia de 7 a 10MHz. De acuerdo con la literatura, el límite inferior de fracción de engrosamiento para realizar una prueba de ventilación espontánea es el 26%, aunque se recomiendan más estudios para confirmar este dato.

Conclusiones

Se refuerza el uso del ultrasonido como herramienta segura, costo-efectiva, práctica, no invasiva, a la cabecera del paciente. Además, con los resultados obtenidos se propone continuar la investigación en torno a la evaluación del efecto del entrenamiento muscular diafragmático con seguimiento ecográfico.

Palabras clave:
Extubación traqueal
Ultrasonografía
Diafragma
Cuidados intensivos
Abstract
Purpose of the review

The objective of this scoping review was to provide evidence on the use of diaphragmatic ultrasound (US) data as a predictor of extubation in the critically ill patient.

Data collection source

Two independent reviewers searched for articles systematically in the OVID, MEDLINE, Cochrane, Embase, and Google Scholar databases.

Study selection

Original prospective or retrospective observational studies, clinical trials, and review studies were included. Initial search results yielded a total of 2,086 studies. After manual selection according to the inclusion criteria, 10 articles were chosen.

Extraction and synthesis of data

The results showed that the measurement variables to explore the diaphragm are described in two windows per US, which are reproducible, and are performed in both the liver and spleen windows. In addition, it was found that a linear high frequency probe from 7 to 10MHz was used to measure the thickening fraction. According to the literature, the lower limit of the thickening fraction to perform a spontaneous ventilation test is 26%, although more studies are recommended to confirm this data.

Conclusions

The use of ultrasound is reinforced as a safe, cost-effective, practical, non-invasive tool at the patient bedside. Furthermore, with the results obtained, it is recommended to continue the research around the evaluation of the effect of diaphragmatic muscle training with ultrasound monitoring.

Keywords:
Airway extubation
Ultrasound
Diaphragm
Intensive care

Article

These are the options to access the full texts of the publication Acta Colombiana de Cuidado Intensivo
Member

Socios de la Asociación de Medicina Crítica y Cuidado Intensivo

Para acceder a la revista

Es necesario que lo haga desde la zona privada de la web de la AMCI, clique aquí

Subscriber
Subscriber

If you already have your login data, please click here .

If you have forgotten your password you can you can recover it by clicking here and selecting the option “I have forgotten my password”
Subscribe
Subscribe to

Acta Colombiana de Cuidado Intensivo

Purchase
Purchase article

Purchasing article the PDF version will be downloaded

Price 19.34 €

Purchase now
Contact
Phone for subscriptions and reporting of errors
From Monday to Friday from 9 a.m. to 6 p.m. (GMT + 1) except for the months of July and August which will be from 9 a.m. to 3 p.m.
Calls from Spain
932 415 960
Calls from outside Spain
+34 932 415 960
E-mail
Article options
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos