metricas
covid
Buscar en
Clinics
Toda la web
Inicio Clinics Efficacy and safety of a NiTi CAR 27 compression ring for end-to-end anastomosis...
Journal Information
Vol. 71. Issue 5.
Pages 264-270 (January 2016)
Share
Share
Download PDF
More article options
Visits
607
Vol. 71. Issue 5.
Pages 264-270 (January 2016)
CLINICAL SCIENCE
Open Access
Efficacy and safety of a NiTi CAR 27 compression ring for end-to-end anastomosis compared with conventional staplers: A real-world analysis in Chinese colorectal cancer patients
Visits
607
Zhenhai Lu, Jianhong Peng, Cong Li, Fulong Wang, Wu Jiang, Wenhua Fan, Junzhong Lin, Xiaojun Wu, Desen Wan, Zhizhong Pan
Corresponding author
panzhzh@sysucc.org.cn

Corresponding author
Sun Yat-Sen University Cancer Center; State Key Laboratory of Oncology in South China, Collaborative Innovation Center of Cancer Medicine, Department of Colorectal Surgery, Guangzhou, P.R., China
This item has received

Under a Creative Commons license
Article information
Abstract
Full Text
Bibliography
Download PDF
Statistics
Figures (6)
Show moreShow less
OBJECTIVES:

This study aimed to evaluate the safety and efficacy of a new nickel-titanium shape memory alloy compression anastomosis ring, NiTi CAR 27, in constructing an anastomosis for colorectal cancer resection compared with conventional staples.

METHODS:

In total, 234 consecutive patients diagnosed with colorectal cancer receiving sigmoidectomy and anterior resection for end-to-end anastomosis from May 2010 to June 2012 were retrospectively analyzed. The postoperative clinical parameters, postoperative complications and 3-year overall survival in 77 patients using a NiTi CAR 27 compression ring (CAR group) and 157 patients with conventional circular staplers (STA group) were compared.

RESULTS:

There were no statistically significant differences between the patients in the two groups in terms of general demographics and tumor features. A clinically apparent anastomotic leak occurred in 2 patients (2.6%) in the CAR group and in 5 patients (3.2%) in the STA group (p=0.804). These eight patients received a temporary diverting ileostomy. One patient (1.3%) in the CAR group was diagnosed with anastomotic stricture through an electronic colonoscopy after 3 months postoperatively. The incidence of postoperative intestinal obstruction was comparable between the two groups (p=0.192). With a median follow-up duration of 39.6 months, the 3-year overall survival rate was 83.1% in the CAR group and 89.0% in the STA group (p=0.152).

CONCLUSIONS:

NiTi CAR 27 is safe and effective for colorectal end-to-end anastomosis. Its use is equivalent to that of the conventional circular staplers. This study suggests that NiTi CAR 27 may be a beneficial alternative in colorectal anastomosis in Chinese colorectal cancer patients.

KEYWORDS:
NiTi CAR 27
Anastomosis
Colorectal Cancer
Efficacy
Safety
Full Text
INTRODUCTION

In China, colorectal cancer (CRC) has become one of the most common malignancies, ranking fifth in males and fourth in females 1. Although surgical resection is the most effective method for curing CRC, postoperative complications such as anastomotic leakage reportedly lead to poor oncologic outcomes such as local recurrence in CRC patients 2,3. Currently, a stapling device is widely used for providing well-established anastomosis, especially for a low anterior resection, as this device can place the purse-string suture on the distal rectum, which is impossible in the hand-sewn procedure 4-6. Nevertheless, anastomotic complications, such as anastomotic bleeding, strictures and leakages, still occur postoperatively 7-9. Additionally, the localized inflammatory response accounts for the foreign bodies that cross the mucosal barriers and thus evoke potential anastomosis-related morbidity 10,11.

Recently, new compression devices incorporating nickel-titanium shape memory alloys (NiTi CAR 27) have been applied for end-to-end colorectal anastomosis. Unlike the traditional staplers, NiTi CAR 27 provides sutureless colorectal anastomosis by using compression, which may thus avoid anastomotic complications resulting from inflammatory processes due to the suture equipment 11. The safety of NiTi CAR 27 has been demonstrated in numerous animal studies 12,13. Early clinical research also suggested that NiTi CAR 27 might create a more secure colorectal anastomosis and serve as an effective alternative for anastomotic procedures 14,15. To date, the clinical outcome after the application of NiTi CAR™27 on CRC Chinese patients remains unclear. The aim of this single-center study is to evaluate the safety and efficacy of a NiTi CAR 27 device in an end-to-end anastomosis after sigmoidectomy and anterior resection by comparing the complication rates and the long-term postoperative survival data with stapled anastomosis.

METHODSPatients

In this retrospective study, consecutive patients undergoing sigmoidectomy and anterior resection with NiTi CAR 27 were included from May 2010 to June 2012 at the Cancer Center, Sun Yat-Sen University, Guangzhou, China. The clinical data of CRC in the similar locations resected using stapled anastomosis (STA) were collected during the same period. The inclusion criteria were as follows: age >18 years, Eastern Cooperative Oncology Group (ECOG) performance status ≤2, pathological diagnosis of adenocarcinoma, and rectum tumor located ≥3 cm above the anal verge. The exclusion criteria were as follows: tumor located on the right side of the colon, sigmoidectomy and an anterior resection performed previously, uncontrolled severe cardiovascular and respiratory system disease, pregnancy, and a history of other active malignancies (except for basal cell carcinoma of the skin) during the previous 3 years. NiTi CAR 27 was applied for the end-to-end anastomosis by a team of surgeons who have been using stapling anastomotic devices for more than 10 years in our department. The pathological stage of the tumor in the resected specimen was classified according to the tumor-node-metastasis (TNM) staging system of the American Joint Committee on Cancer/International Union Against Cancer (AJCC/UICC) 16. Prior to the surgical procedure, informed consent was obtained from all of the patients. They were well informed of the method of anastomotic construction by NiTi CAR 27. Study approval was obtained from independent ethics committees at the Cancer Center of Sun Yat-Sen University. The study was undertaken in accordance with the ethical standards of the World Medical Association Declaration of Helsinki.

Evaluation of clinical parameters

The clinical data on the patient demographics, tumor features, perioperative parameters, and postoperative complications were recorded with an electronic medical record system. The perioperative parameters included the length of the operation time, the perioperative blood loss during the hospital stay, and the time to the first flatus. Clinical anastomotic leakage was diagnosed based on symptoms such as fever, abdominal pain and tenderness. The presence of fecal discharge from the pelvic drain or fecal bubbles surrounding the anastomosis observed in computed tomography scans was also recognized as anastomotic leakage. Anastomotic stricture was well defined as the diameter of the lumen that was smaller than a standard 12-mm diameter colonoscopy. Anastomotic hemorrhage was noted when there was an excess anal blood loss of 50 ml postoperatively.

Description and procedure of using NiTi CAR 27

NiTi CAR 27 is composed of a main body and detachable compression elements (Figure 1). The compression elements include a plastic anvil ring and a metal ring incorporating a temperature-dependent shape memory nitinol leaf. The leaf springs maintain a continuous pressure at the anastomosis, independent of the thickness of the tissue. When the tissue around the circular edges heals, the compression element falls off of the compressed tissue within the following 8-10 days as the metal ring is expelled from the body by bowel movement 17. The NiTi CAR 27 was manipulated according to the manufacturer's instructions. Before the procedure, the nitinol metal ring is saturated in ice water for approximately 30 seconds. After the anvil of the NiTi CAR 27 is secured, the bowel is returned to the peritoneal cavity. Then, the firing device is pushed from the anus to the blind end of the corresponding colorectum. Subsequently, the knob is rotated to the left until the pricker of the firing device reaches a proper position and connects with the anvil. The knob is rotated to the right as a click sound is heard. As a result, end-to-end anastomosis is constructed by pushing forward the firing handle and withdrawing the firing device from the intestinal canal. Finally, the completion of the anastomosis is confirmed by an air-leak test. If the leakage test is positive, a diverting ileostomy is performed.

Figure 1.

The structure of the NiTi compression anastomosis ring (NiTi CAR 27). It consists of 1. A nitinol mental compression ring, 2. an anvil, 3. a ring loader, and 4. a firing device.

(0.02MB).
Postoperative follow-up

After discharge from the hospital, all patients were followed up in the first month after the operation and every 3 months for the first 2 years postoperatively. Then, an every 6-month follow-up was conducted until 5 years after the surgical operation. The follow-up data were obtained by mail, telephone correspondence and outpatient department visits. The routine follow-up visits consisted of a physical examination, routine blood tests, chest radiography, abdominal ultrasonography (US), contrast-enhanced computed tomography (CT) scans and a pelvic nuclear magnetic resonance (MRI). An electronic colonoscopy was suggested for all patients at the third month postoperatively.

Statistical analyses

The continuous variables are presented as the mean ± standard deviations and were compared using a Mann–Whitney U-test or Fisher's exact test. Categorical results were compared using a chi-square test. The Kaplan–Meier method was applied to determine the overall survival (OS). Differences in survival outcomes between the two groups were compared with the log-rank test. All of the tests were two-tailed, in which a p value <0.05 was considered statistically significant. The data were analyzed using Statistical Package for the Social Sciences (SPSS) 17.0 for Windows (SPSS Inc. Chicago, IL, USA).

RESULTSClinical characteristics

A total of 234 patients received an anterior resection or a sigmoidectomy for colorectal cancer. The clinical pathological characteristics of the patients from the group with anastomosis using NiTi CAR 27 (CAR group, N=77) and the group with the stapling device (STA group, N=157) were compared (Table 1). There was no significant difference in terms of preoperative clinical demographics and tumor features, including age, sex, clinical stage, body mass index (BMI), tumor sites and comorbidities with the exception of severe anemia. Perioperative parameters, including length of operation time, perioperative blood loss, hospital stay and time to first flatus, were also comparative between the two groups (Table 2).

Table 1.

Clinical characteristics of the patients in the NiTi CAR 27 and stapler subgroups.

  NiTi CAR 27  Stapler  p value 
Clinical characteristics  (N=77)  (N=157)   
Gender      0.868 
Male  46(59.7%)  92(58.6%)   
Female  31(40.3%)  65(41.4%)   
Median age (year, range)  60(20-77)  59(20-81)  0.885 
Median BMI (kg/m222.5(14.6 - 29.9)  22.1(16.4 - 29.7)  0.908 
Comorbidities       
Hypertension  18(23.4%)  26(16.6%)  0.210 
Diabetes mellitus  2(2.6%)  10(6.4%)  0.219 
Obesity  20(26.0%)  31(19.7%)  0.278 
Severe anemia  2(2.6%)  0(0)  0.043 
Intestinal obstruction  1(1.3%)  2(1.3%)  0.987 
Preoperative chemoradiotherapy  8(10.4%)  25(15.9%)  0.253 
Tumor site      0.938 
Sigmoid colon  32(41.6%)  32(40.8%)   
Upper rectum (>5 cm)  41(53.2%)  41(52.9%)   
Lower rectum (≤5 cm)  4(5.2%)  10(6.4%)   
Postoperative pathological stage      0.491 
Stage 0  4(5.2%)  7(4.5%)   
Stage I  14(18.2%)  21(13.4%)   
Stage II  27(35.0%)  51(32.5%)   
Stage III  20(26.0%)  56(35.6%)   
Stage IV  12(15.6%)  22(14.0%)   

Abbreviations: BMI: body mass index

Table 2.

Perioperative data of the patients receiving compression and stapled anastomosis.

Parameter  NiTi CAR 27 (N=77)  Stapler (N=157)  p value 
Type of operation       
Sigmoidectomy  31(40.3%)  64(40.8%)  0.941 
Anterior resection  46(59.7%)  93(59.2%)   
Median operation time (min, range)  140(60-370)  150(60-420)  0.720 
Median perioperative blood loss (ml, range)  50(30-1000)  50(20-300)  0.323 
Time to the first flatus (day, range)  3(1-7)  3(2-8)  0.149 
Median postoperative hospital stay (day, range)  8(6-32)  8(5-29)  0.523 
Postoperative complications

The incidence of postoperative complications, such as anastomotic leakage, anastomotic stricture and intestinal obstruction, did not show significant differences between the two groups (Table 3). Detailed information on the six patients who experienced postoperative complications in the CAR group is summarized in Table 4. A clinically apparent anastomotic leakage occurred in 2 patients (2.6%) (Figure 2). A 46-year-old female undergoing a low anterior resection for rectal cancer (5 cm from the anus) experienced anastomotic leakage on the 4th postoperative day. The other case of leakage was observed in a 61-year-old male who received an anterior resection for rectal cancer (10 cm from the anus) within 5 days after the surgery. A temporary diverting ileostomy was performed for these two patients. Consequently, the symptoms of both patients were relieved after surgery. Anastomotic stricture was diagnosed by an electronic colonoscopy after 3 months in a 65-year-old male (1.3%) receiving an anterior resection (Figure 3). No treatments were required due to the absence of obvious symptoms. Three patients (3.9%) experienced intestinal obstruction at 6-11 days postoperatively. A 74-year-old man recovered after conservative treatment, whereas the condition of a 20-year-old woman receiving the same treatment worsened because of organ failure as a result of tumor progression. Another 68-year-old male with postoperative obstruction was successfully treated with a reoperation. The NiTi CAR 27 rings were spontaneously evacuated from the stool within 10 to 20 days (median 14 days) after the operation (Figure 4). The anastomosis was smooth and without metallic foreign material after 3 months when observed using electronic colonoscopy (Figure 5). No anastomotic hemorrhage or perioperative death occurred in this study.

Table 3.

Comparison of the postoperative complications in two types of anastomotic devices.

Complications  NiTi CAR 27 (N=77)  Stapler (N=157)  p value 
Anastomotic leakage  2(2.6%)  5(3.2%)  0.804 
Anastomotic stricture  1(1.3%)  0(0)  0.152 
Intestinal obstruction  3(3.9%)  2(1.3%)  0.192 
Table 4.

Detailed information on the total postoperative complications in the NiTi CAR 27 group.

Gender  Age  Tumor location  Type of operation  Hospital stay (days)  Complication  Complication detected on POD  Measure of diagnose  Intervention  Outcome 
female  20  rectum  Anterior  resection  27  Intestinal  obstruction  11  abdominal  X-ray  conservative  treatment  deterioration 
female  46  rectum  Anterior  resection  32  Anastomoticleakage  clinical  symptoms  Ileostomy  recovery 
male  65  rectum  Anterior  resection  10  anastomoticstricture  90  electronic  colonoscopy  Wait and see  stabilization 
male  74  Sigmoid  colon  Sigmoidectomy  21  Intestinal obstruction  clinical  symptoms  conservative  treatment  recovery 
male  68  Sigmoid  colon  Sigmoidectomy  25  Intestinal  obstruction  abdominal  X-ray  Operation  recovery 
male  61  rectum  Anterior  resection  21  Anastomoticleakage  abdominal  X-ray  Ileostomy  recovery 

Abbreviations: POD: postoperative day

Figure 2.

Abdominal radiographs showing the preliminary healing of anastomotic leakage after 5 days post-operation with the ring (arrow) retained in the anastomosis before the ileostomy takedown.

(0.04MB).
Figure 3.

One patient experienced anastomosis stricture after 3 months post-operation as determined by an electronic colonoscopy.

(0.06MB).
Figure 4.

The evacuated NiTi compression anastomosis ring (NiTi CAR 27).

(0.05MB).
Figure 5.

The electronic colonoscopy view of the smooth anastomosis after 3 months postoperatively.

(0.06MB).
Long-term outcome

With median follow-up duration was 39.6 months. The 3-year overall survival rates in the CAR group and the STA group were 83.1% and 89.0%, respectively (p=0.152, Figure 6A). For the stage I-III patients, the 3-year overall survival rates in the CAR group and the STA group were 94.5% and 98.2%, respectively (p=0.205, Figure 6B). For the stage IV patients, the 3-year overall survival rates in the CAR group and the STA group were 12.1% and 32.3%, respectively (p=0.170, Figure 6C).

Figure 6.

The 3-year overall survival (OS) was 83.1% (CAR group) and 89.0% (STA group), p=0.152(A). In the stage 0-III patients, the 3-year OS was 94.5% (CAR group) and 98.2% (STA group), p=0.205; (B) in the stage IV patients, the 3-year OS was 12.1% (CAR group) and 32.3% (STA group), p=0.170 (C).

(0.02MB).
DISCUSSION

Nitinol, an advanced metal alloy of nickel and titanium, exhibits “shape memory,” which is the ability to return to its original shape after being deformed according to the temperature 18. NiTi CAR 27, a new device manufactured with this metal alloy, has several advantages over conventional staplers for colorectal anastomosis. First, the nitinol leaf springs adapt to variations in tissue thickness and accommodate the compressed tissue with a constant force around the full circumference of the anastomosis 11. Without a permanent suture remaining, the use of this device reduces the local long-term inflammatory process of anastomosis. Moreover, the scarring area of the anastomosis is minimal and appears smooth during the healing process 19-21. Although the US Food and Drug Administration (FDA) approved NiTi CAR™ 27 for use in intestinal anastomoses in August 2006, clinical experiments using NiTi CAR 27 in colorectal anastomosis are scarce in China. To evaluate the safety and efficacy of using this device for colorectal cancer surgery, we conducted the present study on Chinese patients.

Thus far, most clinical studies on the application of NiTi CAR 27 for colorectal anastomosis have been conducted from a single center, including only elective cases from several countries. The collected information of the postoperative complications from partial clinical trials involving nitinol compression devices for colorectal anastomosis between 2011 and 2014 are shown inTable 421-23,17,24,14,25,15. Lee et al. performed a left-sided colon resection with an anastomosis in 79 patients by using NiTi CAR 27. The phase II study showed that only 1 of 79 (1.3%) patients experienced anastomotic leakage after 6 days postoperatively without any clinical symptoms of anastomotic stricture 22. Another study examining the short-term clinical outcome of a phase II prospective study in 23 patients also demonstrated that NiTi CAR 27 is a promising, safe and effective alternative for the creation of left-side colorectal anastomosis with a low risk of morbidities, including 1 case of abscess (4.3%), 1 case of anastomotic leakage (4.3%) and 2 cases of anastomotic strictures (8.7%) 17. In addition, the largest data analysis of 1,180 patients who underwent rectal resection with the NiTi ColonRing for an end-to-end anastomosis from 178 centers in 16 countries revealed a promising clinical result, with only a 3.2% (38 patients) overall anastomotic leakage rate 14. These results suggested that NiTi CAR 27 might be a safe and flexible device for colorectal surgery with a low incidence of postoperative complications.

Compared to stapled anastomosis, the occurrence of general postoperative complications related with anastomosis constructed by the NiTi CAR 27 was not significantly different in our study. Only 2 clinically apparent anastomotic leakages (2.6%) and 1 anastomotic stricture (1.3%) occurred without any anastomotic hemorrhage. As reported in previous clinical studies, anastomotic leakage occurred in 6% to 8% of the individuals with anterior resection by traditional staplers for rectal cancer patients 26-28. Our study indicated that the use of NiTi CAR 27 for colorectal anastomosis resulted in a slightly lower risk of anastomotic leakage when compared to a stapled anastomosis (2.6% versus 3.2%, p=0.804). A similar result was obtained in another study in lower located rectal cancer (within 6 cm from the anal verge) anterior resection by comparison of stapled and compression anastomosis 15. We observed only 1 patient (1.3%) in the CAR group with anastomotic stricture after anterior resection for rectal cancer at 3 months postoperatively without obvious problems of defecation. Thus far, the cause of anastomotic stricture has not been elucidated. Previous studies have assumed the occurrence of anastomotic stricture was an undetected anastomotic leakage after surgery 25. We considered inadequate blood supply in the anastomosis to also be a potential cause of anastomotic stricture resulting from the persistent pressure by the compression ring. As previous studies have reported, anastomotic hemorrhage was also reduced by using a compression anastomosis ring for colorectal anastomosis 23,25,10. There was no bleeding at the anastomosis site in the CAR group. The compression ring remains in the body to fix the anastomosis for several days and this sustained pressure forced by the compression ring of the NiTi CAR 27 might play a crucial part in preventing bleeding by compressing the small vessels surrounding the anastomosis. It was assumed that it was beneficial to use the NiTi CAR 27 in patients with a high risk of bleeding. To date, the relationship between the compression device and CRC prognosis has not yet been analyzed 29,25. Short-term observations were not sufficient to determine the endpoint of tumor recurrence and progression. Here, we propose the 3-year follow-up survival outcome of the CRC patients who used the NiTi CAR 27. In terms of the comparable 3-year overall survival result between the two groups, we considered that the NiTi CAR 27 obtained a similar long-term survival efficacy for rectal cancer compared with the traditional staplers used for CRC surgery.

There are potential limitations of this study. The first is its retrospective methodology from a single-institution experience. To reduce bias, we only enrolled patients who had the same disease and who underwent the end-to-end anastomosis surgical procedures. Moreover, the limited number of patients in the present study made it difficult to distinguish the slight difference at the level of statistical significance. In addition, the initial treatment for colorectal cancer and the preoperative treatments varied, especially with respect to radiotherapy. These factors, to some extent, influence the occurrence of postoperative complications and long-term survival. However, even with these limitations, the results of our study can be of value for prospective clinical studies in the future.

In conclusion, NiTi CAR 27 is safe and effective for end-to-end anastomosis in colorectal cancer (CRC) surgery with acceptable postoperative complications and shows a similar long-term efficacy in comparison with conventional circular staplers. The use of NiTi CAR 27 is equivalent to that of the conventional circular staplers, suggesting that NiTi CAR 27 might be a beneficial alternative for colorectal anastomosis in Chinese CRC patients.

Table 5.

Summary of the anastomosis-related postoperative complications that occurred in the patients using the nitinol compression devices.

Author(References)  Year  Patients (N)  Median time to first flatus (Day)  Hospital stay (Day)  Anastomotic leakage  Anastomotic hemorrhage  Anastomotic stricture 
Lee et al. (222011  79  NR  7 (4-29)  1 (1.3%) 
Buchberg et al. (172011  23  4 (2–31)  5 (3-41)  1 (4.3%)  2 (8.7%) 
Dauser et al. (232011  62  3 (1-6)  8 (4-183)  1 (3.3%) 
Koo et al. (212012  66  NR  7 (4-20)  1 (1.5%) 
Bernhard et al. (152013  38  NR  11  2 (5.3%) 
Khromov et al. (242013  40  2.4  7.3  2(5%) 
Masoomi et al. (142013  1180  NR  6 (2-21)  38 (3.2%)  NR  NR 
Kwag et al. (252014  63  1.7  5.9  1 (1.6%)  1 (1.6%) 
Present study  2014  79  3 (1-7)  8 (6-32)  2 (2.6%)  1 (1.3%) 

NR: Not recorded

AUTHOR CONTRIBUTIONS

Lu Z, Peng J and Li C designed the study, performed the data analysis and wrote the first draft. Pan Z and Wan D were the coordinating investigators for the study and participated in the preparation of manuscript and study protocol. Wang F, Jiang W, Fan W, Lin J and Wu X participated in the data acquisition. All of the authors read and approved the final manuscript.

ACKNOWLEDGMENTS

We want to thank all of the patients who participated in this study and all the staff engaged in this study, especially the department of colorectal surgery in the Cancer Center, Sun Yat-Sen University.

This study was supported by the Science and Technology Planning Project of Guangdong Province, China; item number: 2012B031800072.

REFERENCES
[1]
W Chen , R Zheng , H Zeng , S Zhang , J He .
Annual report on status of cancer in China, 2011.
[2]
SW Bell , KG Walker , MJ Rickard , G Sinclair , OF Dent , PH Chapuis , et al.
Anastomotic leakage after curative anterior resection results in a higher prevalence of local recurrence.
[3]
PM Krarup , A Nordholm-Carstensen , LN Jorgensen , H Harling .
Anastomotic leak increases distant recurrence and long-term mortality after curative resection for colonic cancer: a nationwide cohort study.
[4]
HP Redmond , OM Austin , AP Clery , JM Deasy .
Safety of double-stapled anastomosis in low anterior resection.
[5]
KS Venkatesh , N Morrison , DM Larson , P Ramanujam .
Triangulating stapling technique: an alternative approach to colorectal anastomosis.
[6]
RJ Heald , RJ Leicester .
The low stapled anastomosis.
Diseases of the colon and rectum, 24 (1981), pp. 437-444
[7]
B Davis , DE Rivadeneira .
Complications of colorectal anastomoses: leaks, strictures, and bleeding.
[8]
JS Kim , SY Cho , BS Min , NK Kim .
Risk factors for anastomotic leakage after laparoscopic intracorporeal colorectal anastomosis with a double stapling technique.
Am Coll Surg, 209 (2009), pp. 694-701
[9]
HT Kirat , RP Kiran , L Lian , FH Remzi , VW Fazio .
Influence of stapler size used at ileal pouch–anal anastomosis on anastomotic leak, stricture, long-term functional outcomes, and quality of life.
[10]
C Avgoustou , P Penlidis , A Tsakpini , C Sioros , D Giannousis .
Compression anastomoses in colon and rectal surgery with the NiTi ColonRing.
[11]
H Tulchinsky , H Kashtan , M Rabau , N Wasserberg .
Evaluation of the NiTi Shape Memory BioDynamix ColonRing in colorectal anastomosis: first in human multi-center study.
[12]
ON Tucker , N Beglaibter , RJ Rosenthal .
Compression anastomosis for Roux-en-Y gastric bypass: observations in a large animal model.
[13]
IL Nudelman , VV Fuko , S Morgenstern , S Giler , S Lelcuk .
Gastrointestinal anastomosis with the nickel-titanium double ring.
[14]
H Masoomi , R Luo , S Mills , JC Carmichael , AJ Senagore , MJ Stamos .
Compression anastomosis ring device in colorectal anastomosis: a review of 1,180 patients.
[15]
B Dauser , T Braunschmid , S Ghaffari , S Riss , A Stift , F Herbst .
Anastomotic leakage after low anterior resection for rectal cancer: comparison of stapled versus compression anastomosis.
[16]
SB Edge , CC Compton .
The American Joint Committee on Cancer: the 7th edition of the AJCC cancer staging manual and the future of TNM.
[17]
BS Buchberg , H Masoomi , H Bergman , SD Mills , MJ Stamos .
The use of a compression device as an alternative to hand-sewn and stapled colorectal anastomoses: is three a crowd.
[18]
IL Nudelman , V Fuko , F Greif , S Lelcuk .
Colonic anastomosis with the nickel-titanium temperature-dependent memory-shape device.
[19]
M Berho , SD Wexner , AM Botero-Anug , D Pelled , JW Fleshman .
Histopathologic advantages of compression ring anastomosis healing as compared with stapled anastomosis in a porcine model: a blinded comparative study.
[20]
PC Liu , ZW Jiang , XL Zhu , ZM Wang , YQ Diao , N Li , et al.
Compression anastomosis clip for gastrointestinal anastomosis.
[21]
EJ Koo , HJ Choi , JH Woo , KJ Park , YH Roh , KH Kim , et al.
Anastomosis by use of compression anastomosis ring (CAR 27) in laparoscopic surgery for left-sided colonic tumor.
[22]
JY Lee , JH Woo , HJ Choi , KJ Park , YH Roh , KH Kim , et al.
Early experience of the compression anastomosis ring (CAR 27) in left-sided colon resection.
[23]
B Dauser , T Winkler , G Loncsar , F Herbst .
Compression anastomosis revisited: prospective audit of short- and medium-term outcomes in 62 rectal anastomoses.
[24]
Y Khromov , I Pliakos , M Ibrahim , AP Zbar , J Sayfan , TS Papavramidis .
A prospective multi-institutional study assessing clinical outcome with the NiTi compression anastomosis ring (Biodynamix ColonRingTM) in elective colorectal anastomoses.
Hepatogastroenterology, 60 (2013), pp. 522-527
[25]
SJ Kwag , JG Kim , WK Kang , JK Lee , ST Oh .
Niti CAR 27 versus a conventional end-to-end anastomosis stapler in a laparoscopic anterior resection for sigmoid colon cancer.
[26]
JS Park , GS Choi , SH Kim , HR Kim , NK Kim , KY Lee , et al.
Multicenter analysis of risk factors for anastomotic leakage after laparoscopic rectal cancer excision: the Korean laparoscopic colorectal surgery study group.
[27]
Y Liu , X Wan , G Wang , Y Ren , Y Cheng , Y Zhao , et al.
A scoring system to predict the risk of anastomotic leakage after anterior resection for rectal cancer.
[28]
L Yang , XE Huang , JN Zhou .
Risk assessment on anastomotic leakage after rectal cancer surgery: an analysis of 753 patients.
[29]
J Okuda , K Tanaka , K Kondo , K Asai , H Kayano , M Yamamoto , et al.
Safe anastomosis in laparoscopic low anterior resection for rectal cancer.

No potential conflict of interest was reported.

Copyright © 2016. CLINICS
Download PDF
Article options
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

Quizás le interese:
10.6061/clinics/2021/e2498