covid
Buscar en
Revista de Calidad Asistencial
Toda la web
Inicio Revista de Calidad Asistencial Factores asociados a la adecuación de la utilización de vías venosas en el se...
Journal Information
Vol. 19. Issue 2.
Pages 83-87 (January 2004)
Share
Share
Download PDF
More article options
Vol. 19. Issue 2.
Pages 83-87 (January 2004)
Full text access
Factores asociados a la adecuación de la utilización de vías venosas en el servicio de urgencias
Visits
4996
Mónica Robles-Garcíaa,1
Corresponding author
monicarobles@yahoo.es

Correspondencia: Mónica Robles García. Servicio de Medicina Preventiva. Unidad de Calidad. Hospital Sierrallana. Barrio de Ganzo s/n. Torrelavega. Cantabria. España.
, Begoña Ceballosb, María José Rodríguez-Lerab, Liébana Piedrab, Sara Sánchez-Ortizb, Kristina Boterob
a Servicio de Medicina Preventiva. Unidad de Calidad. Hospital Sierrallana. Torrelavega. Cantabria. España.
b Servicio de Urgencias. Hospital Sierrallana. Torrelavega. Cantabria. España.
This item has received
Article information
Resumen
Objetivos

Determinar la incidencia de uso adecuado de vías venosas en el servicio de urgencias. Identificar factores asociados al mismo. Evaluar el resultado obtenido por las acciones de mejora introducidas.

Material y método

Estudio descriptivo sobre pacientes atendidos en urgencias durante mayo de 2001 y mayo de 2002. Muestreo aleatorio. Variable dependiente: adecuación de vía. Variables independientes: características sociodemográficas y asistenciales. Comparación de proporciones (×2). Cuantificación de asociación entre adecuación y potenciales factores de riesgo: riesgo relativo (RR) e intervalo de confianza (IC) del 95%.

Resultados

Se ha seguido a 226 pacientes portadores de vía venosa. La incidencia de adecuación de utilización de vía venosa fue del 79,2% (85,25% en 2002 y 72,12% en 2001, p = 0,015). Cuarenta y siete casos fueron portadores de vía venosa cuando no era adecuado. La asistencia durante el turno de noche supuso un 21% más de adecuación que durante la tarde (RR = 1,21; IC del 95%, 1,03-1,43), y durante el fin de semana un 15% más que durante el resto de la semana (RR = 1,15; IC del 95%, 1,00-1,31). Los pacientes de riesgo grave presentaron una adecuación un 21% superior a los leves-moderados (RR = 1,21; IC del 95%, 1,07-1,37).

Conclusiones

La adecuación global del uso de vías venosas fue del 79,2%.Tras la difusión de los resultados al servicio implicado y la reevaluación se obtuvo un aumento significativo de adecuación superior al 10%. Los factores de riesgo más fuertemente asociados a la adecuación fueron la gravedad del paciente, la atención realizada durante el turno de noche y preferentemente durante el fin de semana.

Palabras clave:
Vías venosas
Asistencia urgente
Adecuación
Abstract
Objectives

To determine the incidence of appropriate use of venous access in the emergency setting, identify associated factors and evaluate the results obtained after improvements were introduced.

Material and method

We performed a descriptive study of patients attended in the emergency setting in May 2001 and May 2002. Sampling was random. The dependent variable was appropriate use. Independent variables were sociodemographic and healthcare factors. Proportions were compared using the ?2 test. The associations among appropriate use and potential risk factors were evaluated by relative risk (RR) and 95% confidence interval (95% CI).

Results

We evaluated the appropriateness of venous access in 226 patients who underwent intravenous catheterization. Use was appropriate in 79.2% (85.25% in 2002 and 72.12% in 2001, p = 0.015). Venous access was inappropriate in 47 patients. Appropriate use was 21% higher during the night shift than during the afternoon shift (RR = 1.21; 95% CI, 1.03-1.43) and was 15% higher at the weekend than during the rest of the week (RR = 1.15; 95% CI, 1.00-1.31). Appropriate use was 21% higher in patients at serious risk than in those at slight-moderate risk (RR = 1.21; 95% CI, 1.07-1.37).

Conclusions

The overall appropriateness of venous access was 79.2%. The results were made known to the service involved and the use of venous access was reevaluated, leading to a significant increase in appropriateness of more than 10%. The factors most strongly associated with appropriateness were patient severity and procedures performed during the night shift or at the weekend.

Key words:
Venous access
Emergency setting
Appropriateness
Full text is only aviable in PDF
Bibliografía
[1.]
Plan de Calidad de Atención Especializada. Memoria 2000.
Instituto Nacional de la Salud, (2002),
[2.]
J. Zurro Hernández, J.A. de Santiago-Juárez López.
Sanidad y Ediciones, (2002),
[3.]
L. Velasco Díaz, B. Fernández González, S. García Ríos, E. Hernández del Corro.
Evaluación de las vías de acceso venoso innecesarias en un servicio de urgencias.
Med Clin, 114 (2000), pp. 89-90
[4.]
Plan de Calidad de Atención Especializada. Memoria 2001.
Instituto Nacional de la Salud, (2002),
[5.]
W.R. McCabe, G.G. Jackson.
Gram negative bacteriemia: I. Etiology and ecology.
Arch Intern Med, 110 (1962), pp. 845-847
[6.]
G.D. Barlow, S. Palniappan, R. Mukherjee, M.C. Jones, D. Nathwani.
Unnecessary peripheral intravenous catheterisation on an acute medical admissions unit: a preliminary study.
Eur J Intern Med, 13 (2002), pp. 380-384
[7.]
C.M. Parenti, F.A. Lederle, C.L. Impola, L.R. Peterson.
Reduction of unnecessary intravenous catheter use.
Arch Intern Med, 154 (1994), pp. 1829-1832
[8.]
O. Miró.
Evaluación del impacto en la calidad asistencial y análisis coste-efectividad de la reforma de un servicio de urgencias de medicina.
Med Clin (Barc), 117 (2001), pp. 7-11
Copyright © 2004. Sociedad Española de Calidad Asistencial
Article options
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos