se ha leído el artículo
array:24 [ "pii" => "S0365669120302203" "issn" => "03656691" "doi" => "10.1016/j.oftal.2020.05.038" "estado" => "S300" "fechaPublicacion" => "2020-11-01" "aid" => "1749" "copyright" => "Sociedad Española de Oftalmología" "copyrightAnyo" => "2020" "documento" => "article" "crossmark" => 1 "subdocumento" => "fla" "cita" => "Arch Soc Esp Oftalmol. 2020;95:528-37" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:1 [ "total" => 0 ] "Traduccion" => array:1 [ "en" => array:19 [ "pii" => "S2173579420301912" "issn" => "21735794" "doi" => "10.1016/j.oftale.2020.05.032" "estado" => "S300" "fechaPublicacion" => "2020-11-01" "aid" => "1749" "copyright" => "Sociedad Española de Oftalmología" "documento" => "article" "crossmark" => 1 "subdocumento" => "fla" "cita" => "Arch Soc Esp Oftalmol. 2020;95:528-37" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:1 [ "total" => 0 ] "en" => array:12 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Original article</span>" "titulo" => "Evaluation of femtosecond laser-assisted cataract surgery after 10 years of clinical application" "tienePdf" => "en" "tieneTextoCompleto" => "en" "tieneResumen" => array:2 [ 0 => "en" 1 => "es" ] "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "528" "paginaFinal" => "537" ] ] "titulosAlternativos" => array:1 [ "es" => array:1 [ "titulo" => "Evaluacion de la cirugía de la catarata asistida con láser femtosegundo tras 10 años de aplicación clínica" ] ] "contieneResumen" => array:2 [ "en" => true "es" => true ] "contieneTextoCompleto" => array:1 [ "en" => true ] "contienePdf" => array:1 [ "en" => true ] "autores" => array:1 [ 0 => array:2 [ "autoresLista" => "A. Piñero, P. Kanclerz, R.I. Barraquer, M.J. Maldonado, J.L. Alió" "autores" => array:5 [ 0 => array:2 [ "nombre" => "A." "apellidos" => "Piñero" ] 1 => array:2 [ "nombre" => "P." "apellidos" => "Kanclerz" ] 2 => array:2 [ "nombre" => "R.I." "apellidos" => "Barraquer" ] 3 => array:2 [ "nombre" => "M.J." "apellidos" => "Maldonado" ] 4 => array:2 [ "nombre" => "J.L." "apellidos" => "Alió" ] ] ] ] ] "idiomaDefecto" => "en" "Traduccion" => array:1 [ "es" => array:9 [ "pii" => "S0365669120302203" "doi" => "10.1016/j.oftal.2020.05.038" "estado" => "S300" "subdocumento" => "" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:1 [ "total" => 0 ] "idiomaDefecto" => "es" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0365669120302203?idApp=UINPBA00004N" ] ] "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2173579420301912?idApp=UINPBA00004N" "url" => "/21735794/0000009500000011/v1_202011010626/S2173579420301912/v1_202011010626/en/main.assets" ] ] "itemSiguiente" => array:18 [ "pii" => "S0365669120301945" "issn" => "03656691" "doi" => "10.1016/j.oftal.2020.05.016" "estado" => "S300" "fechaPublicacion" => "2020-11-01" "aid" => "1723" "documento" => "article" "crossmark" => 1 "subdocumento" => "fla" "cita" => "Arch Soc Esp Oftalmol. 2020;95:538-43" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:1 [ "total" => 0 ] "es" => array:13 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Artículo original</span>" "titulo" => "Efectos y seguridad del perfluorohexiloctano en la superficie ocular y el endotelio corneal" "tienePdf" => "es" "tieneTextoCompleto" => "es" "tieneResumen" => array:2 [ 0 => "es" 1 => "en" ] "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "538" "paginaFinal" => "543" ] ] "titulosAlternativos" => array:1 [ "en" => array:1 [ "titulo" => "Effects and safety of perfluorohexyloctane on the eye surface and corneal endothelium" ] ] "contieneResumen" => array:2 [ "es" => true "en" => true ] "contieneTextoCompleto" => array:1 [ "es" => true ] "contienePdf" => array:1 [ "es" => true ] "resumenGrafico" => array:2 [ "original" => 0 "multimedia" => array:7 [ "identificador" => "fig0005" "etiqueta" => "Figura 1" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr1.jpeg" "Alto" => 1248 "Ancho" => 1339 "Tamanyo" => 65154 ] ] "descripcion" => array:1 [ "es" => "<p id="spar0045" class="elsevierStyleSimplePara elsevierViewall">Diferencias pareadas en tinciones corneales.</p> <p id="spar0050" class="elsevierStyleSimplePara elsevierViewall">M3: mes 3; M6: mes 6.</p>" ] ] ] "autores" => array:1 [ 0 => array:2 [ "autoresLista" => "A.J. Mateo Orobia, A. Blasco-Martinez, P. Rodríguez-Ausín, L.E. Pablo Júlvez, N. Güemes Villahoz, E. del Prado Sanz, M. Satué Palacián, J.M. Benítez-del-Castillo" "autores" => array:8 [ 0 => array:2 [ "nombre" => "A.J." "apellidos" => "Mateo Orobia" ] 1 => array:2 [ "nombre" => "A." "apellidos" => "Blasco-Martinez" ] 2 => array:2 [ "nombre" => "P." "apellidos" => "Rodríguez-Ausín" ] 3 => array:2 [ "nombre" => "L.E." "apellidos" => "Pablo Júlvez" ] 4 => array:2 [ "nombre" => "N." "apellidos" => "Güemes Villahoz" ] 5 => array:2 [ "nombre" => "E." "apellidos" => "del Prado Sanz" ] 6 => array:2 [ "nombre" => "M." "apellidos" => "Satué Palacián" ] 7 => array:2 [ "nombre" => "J.M." "apellidos" => "Benítez-del-Castillo" ] ] ] ] ] "idiomaDefecto" => "es" "Traduccion" => array:1 [ "en" => array:9 [ "pii" => "S2173579420301547" "doi" => "10.1016/j.oftale.2020.05.015" "estado" => "S300" "subdocumento" => "" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:1 [ "total" => 0 ] "idiomaDefecto" => "en" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2173579420301547?idApp=UINPBA00004N" ] ] "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0365669120301945?idApp=UINPBA00004N" "url" => "/03656691/0000009500000011/v2_202108180554/S0365669120301945/v2_202108180554/es/main.assets" ] "itemAnterior" => array:19 [ "pii" => "S0365669120302434" "issn" => "03656691" "doi" => "10.1016/j.oftal.2020.06.009" "estado" => "S300" "fechaPublicacion" => "2020-11-01" "aid" => "1757" "copyright" => "Sociedad Española de Oftalmología" "documento" => "article" "crossmark" => 1 "subdocumento" => "fla" "cita" => "Arch Soc Esp Oftalmol. 2020;95:523-7" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:1 [ "total" => 0 ] "es" => array:13 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Artículo original</span>" "titulo" => "Diferencias en la visión intermedia: lente intraocular monofocal vs. lente intraocular monofocal de rango extendido" "tienePdf" => "es" "tieneTextoCompleto" => "es" "tieneResumen" => array:2 [ 0 => "es" 1 => "en" ] "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "523" "paginaFinal" => "527" ] ] "titulosAlternativos" => array:1 [ "en" => array:1 [ "titulo" => "Differences in intermediate vision: monofocal intraocular lenses vs. monofocal extended depth of focus intraocular lenses" ] ] "contieneResumen" => array:2 [ "es" => true "en" => true ] "contieneTextoCompleto" => array:1 [ "es" => true ] "contienePdf" => array:1 [ "es" => true ] "resumenGrafico" => array:2 [ "original" => 0 "multimedia" => array:7 [ "identificador" => "fig0005" "etiqueta" => "Figura 1" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr1.jpeg" "Alto" => 1002 "Ancho" => 1341 "Tamanyo" => 68911 ] ] "descripcion" => array:1 [ "es" => "<p id="spar0050" class="elsevierStyleSimplePara elsevierViewall">LIO TECNIS Eyhance/LIO TECNIS 1-pieza.</p>" ] ] ] "autores" => array:1 [ 0 => array:2 [ "autoresLista" => "B. de Luis Eguileor, L. Martínez-Indart, N. Martínez Alday, C. Sacristán Egüén, C. Cuadros Sánchez" "autores" => array:5 [ 0 => array:2 [ "nombre" => "B." "apellidos" => "de Luis Eguileor" ] 1 => array:2 [ "nombre" => "L." "apellidos" => "Martínez-Indart" ] 2 => array:2 [ "nombre" => "N." "apellidos" => "Martínez Alday" ] 3 => array:2 [ "nombre" => "C." "apellidos" => "Sacristán Egüén" ] 4 => array:2 [ "nombre" => "C." "apellidos" => "Cuadros Sánchez" ] ] ] ] ] "idiomaDefecto" => "es" "Traduccion" => array:1 [ "en" => array:9 [ "pii" => "S2173579420301237" "doi" => "10.1016/j.oftale.2020.06.001" "estado" => "S300" "subdocumento" => "" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:1 [ "total" => 0 ] "idiomaDefecto" => "en" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2173579420301237?idApp=UINPBA00004N" ] ] "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0365669120302434?idApp=UINPBA00004N" "url" => "/03656691/0000009500000011/v2_202108180554/S0365669120302434/v2_202108180554/es/main.assets" ] "es" => array:18 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Revisión</span>" "titulo" => "Evaluación de la cirugía de la catarata asistida con láser femtosegundo tras 10 años de aplicación clínica" "tieneTextoCompleto" => true "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "528" "paginaFinal" => "537" ] ] "autores" => array:1 [ 0 => array:4 [ "autoresLista" => "A. Piñero, P. Kanclerz, R.I. Barraquer, M.J. Maldonado, J.L. Alió" "autores" => array:5 [ 0 => array:3 [ "nombre" => "A." "apellidos" => "Piñero" "referencia" => array:1 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">a</span>" "identificador" => "aff0005" ] ] ] 1 => array:3 [ "nombre" => "P." "apellidos" => "Kanclerz" "referencia" => array:1 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">h</span>" "identificador" => "aff0040" ] ] ] 2 => array:3 [ "nombre" => "R.I." "apellidos" => "Barraquer" "referencia" => array:3 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">d</span>" "identificador" => "aff0020" ] 1 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">e</span>" "identificador" => "aff0025" ] 2 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">f</span>" "identificador" => "aff0030" ] ] ] 3 => array:3 [ "nombre" => "M.J." "apellidos" => "Maldonado" "referencia" => array:1 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">g</span>" "identificador" => "aff0035" ] ] ] 4 => array:4 [ "nombre" => "J.L." "apellidos" => "Alió" "email" => array:1 [ 0 => "jlalio@vissum.com" ] "referencia" => array:3 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">b</span>" "identificador" => "aff0010" ] 1 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">c</span>" "identificador" => "aff0015" ] 2 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">*</span>" "identificador" => "cor0005" ] ] ] ] "afiliaciones" => array:8 [ 0 => array:3 [ "entidad" => "Fellow Curso <span class="elsevierStyleItalic">online</span> Experto Universitario en Cirugía Refractiva, Córnea y Catarata, Clínica Piñero, Sevilla, España" "etiqueta" => "a" "identificador" => "aff0005" ] 1 => array:3 [ "entidad" => "División de Oftalmología, Universidad Miguel Hernández, Alicante, España" "etiqueta" => "b" "identificador" => "aff0010" ] 2 => array:3 [ "entidad" => "Vissum Instituto Oftalmológico de Alicante, Alicante, España" "etiqueta" => "c" "identificador" => "aff0015" ] 3 => array:3 [ "entidad" => "Centro de Oftalmología Barraquer, Barcelona, España" "etiqueta" => "d" "identificador" => "aff0020" ] 4 => array:3 [ "entidad" => "Institut Universitari Barraquer, Universitat Autònoma de Barcelona, Barcelona, España" "etiqueta" => "e" "identificador" => "aff0025" ] 5 => array:3 [ "entidad" => "Universitat Internacional de Catalunya, Barcelona, España" "etiqueta" => "f" "identificador" => "aff0030" ] 6 => array:3 [ "entidad" => "Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Valladolid, España" "etiqueta" => "g" "identificador" => "aff0035" ] 7 => array:3 [ "entidad" => "Hygeia Clinic, Gdańsk, Polonia" "etiqueta" => "h" "identificador" => "aff0040" ] ] "correspondencia" => array:1 [ 0 => array:3 [ "identificador" => "cor0005" "etiqueta" => "⁎" "correspondencia" => "<span class="elsevierStyleItalic">Autor para correspondencia</span>." ] ] ] ] "titulosAlternativos" => array:1 [ "en" => array:1 [ "titulo" => "Evaluation of femtosecond laser-assisted cataract surgery after 10 years of clinical application" ] ] "textoCompleto" => "<span class="elsevierStyleSections"><span id="sec0005" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0065">Introducción</span><p id="par0005" class="elsevierStylePara elsevierViewall">El láser de femtosegundo surgió como consecuencia de la búsqueda de láseres para realizar disecciones finas con un mínimo daño en el tejido colateral. Los primeros estudios que emplearon el láser con pulsos de femtosegundo datan del periodo 1987-1991 y describieron las interacciones del láser con la retina<a class="elsevierStyleCrossRefs" href="#bib0375"><span class="elsevierStyleSup">1,2</span></a> y con la piel<a class="elsevierStyleCrossRef" href="#bib0385"><span class="elsevierStyleSup">3</span></a>.</p><p id="par0010" class="elsevierStylePara elsevierViewall">La oftalmología ha sido el campo donde más se ha investigado la aplicación quirúrgica del láser femtosegundo (LFS): en 1989<a class="elsevierStyleCrossRef" href="#bib0380"><span class="elsevierStyleSup">2</span></a> se demostró que las incisiones hechas con el LFS eran superiores a las del láser de nanosegundo. No obstante, debido a la dificultad técnica de trabajar con el LFS, la investigación se centró en los láseres de picosegundos, como el láser Nd: YAG<a class="elsevierStyleCrossRef" href="#bib0390"><span class="elsevierStyleSup">4</span></a>.</p><p id="par0015" class="elsevierStylePara elsevierViewall">A mediados de los años 90 se retomó el interés por encontrar aplicaciones oftalmológicas del LFS. Un ingeniero biomédico llamado Tibor Juhasz, investigador del LFS, comenzó a reflexionar sobre las aplicaciones médicas<a class="elsevierStyleCrossRef" href="#bib0395"><span class="elsevierStyleSup">5</span></a>. Se publicaron diferentes modelos teóricos de ablación del tejido con el láser, así como múltiples estudios biofísicos que describían la interacción del LFS con muestras corneales de animales y cadáveres<a class="elsevierStyleCrossRef" href="#bib0390"><span class="elsevierStyleSup">4</span></a>. Fue en 2003 cuando el grupo de Nordan<a class="elsevierStyleCrossRef" href="#bib0400"><span class="elsevierStyleSup">6</span></a> publicó el primer ensayo clínico sobre la realización del <span class="elsevierStyleItalic">flap</span> corneal con LFS en un Lasik.</p><p id="par0020" class="elsevierStylePara elsevierViewall">El primer LFS aprobado en los Estados Unidos fue el láser IntraLase (Abbott Medical Optics, Southfield, EE.UU.), que obtuvo la aprobación de la <span class="elsevierStyleItalic">Food and Drug Administration</span> en 2001.</p><p id="par0025" class="elsevierStylePara elsevierViewall">Respecto a los fundamentos tecnológicos, el LFS es un láser infrarrojo de pulso ultracorto (10<span class="elsevierStyleSup">-5</span> segundos) con una longitud de onda de 1.053<span class="elsevierStyleHsp" style=""></span>nm. El mecanismo de acción de este láser consiste en una fotodisrupción del tejido ópticamente transparente, que crea una burbuja de cavitación y resulta en la separación física del estroma en esa lámina.</p><p id="par0030" class="elsevierStylePara elsevierViewall">Se comenzó a aplicar con éxito en la cirugía refractiva y corneal<a class="elsevierStyleCrossRef" href="#bib0405"><span class="elsevierStyleSup">7</span></a> y, en agosto de 2008, se describió la primera aplicación en cirugía de catarata para la realización de la capsulorrexis y la fragmentación del cristalino (Budapest, Universidad Semmelweis, por el Dr. Zoltan Z. Nagy<a class="elsevierStyleCrossRef" href="#bib0410"><span class="elsevierStyleSup">8</span></a>).</p><p id="par0035" class="elsevierStylePara elsevierViewall">Los primeros resultados objetivaron un mayor centrado y precisión de la capsulorrexis, con un mejor centrado de la lente intraocular (LIO) y un menor poder de ultrasonidos en ojos porcinos y humanos<a class="elsevierStyleCrossRef" href="#bib0415"><span class="elsevierStyleSup">9</span></a>.</p><p id="par0040" class="elsevierStylePara elsevierViewall">Aunque hay una buena evidencia de las ventajas del LFS en cirugía de catarata, tras estos años, no se han demostrado universalmente los beneficios de la técnica.</p><p id="par0045" class="elsevierStylePara elsevierViewall">En su revisión, Popovic et al.<a class="elsevierStyleCrossRef" href="#bib0420"><span class="elsevierStyleSup">10</span></a> estudiaron las ventajas e inconvenientes de la cirugía de la catarata asistida con el láser femtosegundo (FLACS). Tras el análisis, no encontraron diferencias estadísticamente significativas en cuanto a resultados visuales y refractivos, ni en complicaciones generales entre la cirugía asistida por láser y la cirugía convencional. Sí describieron diferencias estadísticamente significativas en la disminución del tiempo efectivo de facoemulsificación, disminución de las células endoteliales, menor grosor corneal central postoperatorio y mejoría en circularidad de la capsulotomía.</p></span><span id="sec0010" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0070">Método de análisis de la literatura</span><p id="par0050" class="elsevierStylePara elsevierViewall">Se realizó una búsqueda avanzada en las plataformas PubMed y Web of Science, introduciendo aplicaciones clínicas y resultados de FLACS en humanos hasta el 15 de junio de 2019. Concretamente, profundizamos en artículos publicados desde la revisión de Hooshmand y Vote<a class="elsevierStyleCrossRef" href="#bib0425"><span class="elsevierStyleSup">11</span></a> en junio de 2017, aunque también se incluyeron artículos anteriores.</p><p id="par0055" class="elsevierStylePara elsevierViewall">Tras analizar los resultados obtenidos en las plataformas, eliminando los duplicados e incluyendo solo los artículos con resumen en inglés, se seleccionaron un total de 428 referencias. Toda la información se analizó de forma exhaustiva, lo que permitió una visión global.</p><p id="par0060" class="elsevierStylePara elsevierViewall">Asimismo, también se consideraron las listas de referencias de publicaciones identificadas, capítulos de libros específicos relevantes y ensayos registrados en ClinicalTrials.gov.</p></span><span id="sec0015" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0075">Ventajas e inconvenientes intraoperatorios de la cirugía de la catarata asistida con láser femtosegundo</span><p id="par0065" class="elsevierStylePara elsevierViewall">En la <a class="elsevierStyleCrossRef" href="#tbl0005">tabla 1</a> describimos las complicaciones intraoperatorias de la técnica FLACS.</p><elsevierMultimedia ident="tbl0005"></elsevierMultimedia><p id="par0070" class="elsevierStylePara elsevierViewall">Existen, actualmente, complicaciones que se consideran específicas de la cirugía FLACS. Entre ellas podemos destacar los desgarros de la cápsula anterior y las complicaciones derivadas de la pérdida de la succión (marcas en la cápsula anterior). No obstante, cabe reseñar que las complicaciones han ido disminuyendo con el tiempo y con la experiencia del cirujano. Roberts et al. describieron un 10,5% de desgarros capsulares en sus primeros 200 casos, porcentaje que disminuyó al 1,6% en los siguientes 1.300 pacientes<a class="elsevierStyleCrossRef" href="#bib0400"><span class="elsevierStyleSup">6</span></a>.</p><span id="sec0020" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0080">Complicaciones asociadas con el acoplamiento láser</span><p id="par0075" class="elsevierStylePara elsevierViewall">Existen 2<span class="elsevierStyleHsp" style=""></span>mecanismos para el acoplamiento del láser. Uno es a través de contacto, con las plataformas de aplanamiento y el otro es de no contacto (sin aplanamiento).</p><p id="par0080" class="elsevierStylePara elsevierViewall">En las plataformas de aplanamiento es necesario aplicar vacío tras la colocación del interfaz del paciente. El nivel de vacío alcanzado es menor que el de los microqueratomos manuales, aunque el tiempo de vacío es mayor<a class="elsevierStyleCrossRef" href="#bib0450"><span class="elsevierStyleSup">16</span></a>. La presión intraocular que se alcanza en las plataformas de contacto es mayor que la alcanzada en pacientes con óptica de inmersión<a class="elsevierStyleCrossRef" href="#bib0455"><span class="elsevierStyleSup">17</span></a>. No obstante, no existe una evidencia científica clara de que el aumento de la presión intraocular en este procedimiento sea dañino, aunque deberá considerarse en pacientes con glaucoma.</p><p id="par0085" class="elsevierStylePara elsevierViewall">Se ha descrito que los ojos con glaucoma presentan un aumento transitorio de la presión intraocular inmediatamente después del tratamiento y una presión intraocular residual, tras el acoplamiento, también mayor que en ojos no glaucomatosos<a class="elsevierStyleCrossRef" href="#bib0460"><span class="elsevierStyleSup">18</span></a>.</p><p id="par0090" class="elsevierStylePara elsevierViewall">También se ha descrito la aparición de pliegues en la superficie posterior de la córnea como consecuencia de la presión ejercida al contacto de la ventosa con la córnea<a class="elsevierStyleCrossRef" href="#bib0465"><span class="elsevierStyleSup">19</span></a>. Este hecho puede favorecer la realización de una capsulotomía incompleta, complicación que minimizan las plataformas de no contacto. La hemorragia subconjuntival es más frecuente también en las plataformas de contacto que en las de no contacto<a class="elsevierStyleCrossRef" href="#bib0455"><span class="elsevierStyleSup">17</span></a>.</p><p id="par0095" class="elsevierStylePara elsevierViewall">Asimismo, algunos autores creen que el movimiento anterior de la base del vítreo durante la succión podría provocar el desarrollo de enfermedad vitreorretiniana<a class="elsevierStyleCrossRef" href="#bib0470"><span class="elsevierStyleSup">20</span></a>.</p><p id="par0100" class="elsevierStylePara elsevierViewall">Todas estas complicaciones mencionadas no se presentan aplicando un interfaz con óptica de inmersión, ni tampoco en las plataformas de contacto asistidas por lente blanda<a class="elsevierStyleCrossRefs" href="#bib0455"><span class="elsevierStyleSup">17,21</span></a>.</p><p id="par0105" class="elsevierStylePara elsevierViewall">El proceso de aplanamiento (plataforma de contacto) presenta un riesgo intrínseco asociado y conlleva un aumento del tiempo quirúrgico<a class="elsevierStyleCrossRef" href="#bib0480"><span class="elsevierStyleSup">22</span></a>.</p><p id="par0110" class="elsevierStylePara elsevierViewall">Con el uso de la ventosa existe el riesgo de pérdida de succión e interrupción del procedimiento. Zhang et al. presentan tasas de finalización de la capsulotomía anterior del 98,6% (IC 95%: 97,8-99,1), tasas de finalización de la facofragmentación de 99,5% (IC 95%: 99,1-99,8) y del 97,6% (IC 95%: 96,7-98,3) respecto a la finalización de las incisiones corneales<a class="elsevierStyleCrossRef" href="#bib0485"><span class="elsevierStyleSup">23</span></a>. Este estudio se realizó con cirujanos expertos y con unos criterios de inclusión muy estrictos, excluyendo a pacientes con cataratas corticales, blancas y duras, enfermedad corneal y cicatriz corneal densa, en la que no se podía usar un LFS para la fragmentación del núcleo ni para la incisión corneal. Existe una serie más pequeña, que describe una tasa de capsulotomía incompleta del 0-12% y una facofragmentación incompleta en el 4-10% de los casos<a class="elsevierStyleCrossRef" href="#bib0475"><span class="elsevierStyleSup">21</span></a>.</p><p id="par0115" class="elsevierStylePara elsevierViewall">Según Bali et al., el número de intentos de acoplamiento con plataforma de contacto en los primeros 100 casos fue de 1,8-1,9, que disminuyeron a 1,2 en los 100 casos siguientes<a class="elsevierStyleCrossRef" href="#bib0490"><span class="elsevierStyleSup">24</span></a>. Sin embargo, Manning et al. describieron un abandono de la técnica por pérdida de succión del 0,1% de los casos<a class="elsevierStyleCrossRef" href="#bib0445"><span class="elsevierStyleSup">15</span></a>.</p></span><span id="sec0025" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0085">Incisiones corneales</span><p id="par0120" class="elsevierStylePara elsevierViewall">Otra aplicación de LFS son las incisiones<a class="elsevierStyleCrossRef" href="#bib0495"><span class="elsevierStyleSup">25</span></a>. Estas son reproducibles y estables en el tiempo<a class="elsevierStyleCrossRef" href="#bib0500"><span class="elsevierStyleSup">26</span></a>. Además, el láser permite seleccionar entre diferentes arquitecturas de incisión, por ejemplo, triplanar para la incisión principal y uniplanar para la paracentesis.</p><p id="par0125" class="elsevierStylePara elsevierViewall">Las características morfológicas de la incisión por femtosegundo han sido analizadas y se ha evidenciado que el borde interno corneal presenta un patrón de diente de sierra. Por el contrario, las incisiones manuales presentan un filo interno más regular o suave.</p><p id="par0130" class="elsevierStylePara elsevierViewall">Además, se encontró un número significativamente mayor de células apoptóticas<a class="elsevierStyleCrossRef" href="#bib0505"><span class="elsevierStyleSup">27</span></a>.</p><p id="par0135" class="elsevierStylePara elsevierViewall">La incisión corneal realizada con láser es más precisa que la manual, aunque ambas presentan una curación similar al trigésimo día del postoperatorio. No obstante, la incisión con láser presenta una mejoría anatómica más lenta que la manual<a class="elsevierStyleCrossRef" href="#bib0510"><span class="elsevierStyleSup">28</span></a>. Rodrigues et al. encontraron una pérdida parcial del sellado de la herida triplanar asistida con femtosegundo en todos los pacientes, en el primer día del postoperatorio. Este resultado fue objetivado por la tomografía de coherencia óptica. Por el contrario, la pérdida parcial del sellado de la herida fue del 44,6% en los pacientes con incisión manual (<span class="elsevierStyleItalic">p</span> = 0,03)<a class="elsevierStyleCrossRef" href="#bib0510"><span class="elsevierStyleSup">28</span></a>. También describieron un grosor de la incisión mayor con femtosegundo que en las incisiones manuales, a pesar de no haber sellado la herida con hidratación estromal, y un mayor número de espacios entre células endoteliales y desprendimientos de membrana de Descemet<a class="elsevierStyleCrossRef" href="#bib0515"><span class="elsevierStyleSup">29</span></a>. Estos resultados los asocian a una mayor manipulación de la incisión<a class="elsevierStyleCrossRef" href="#bib0515"><span class="elsevierStyleSup">29</span></a>.</p><p id="par0140" class="elsevierStylePara elsevierViewall">Otras aplicaciones del LFS son las incisiones arcuatas o la queratotomía arcuata. Estas se utilizan para corregir el astigmatismo de bajo grado en la cirugía de catarata. Las incisiones manuales se caracterizan por ser menos previsibles, presentar una menor reproducibilidad de la longitud y menor alineación con respecto al eje<a class="elsevierStyleCrossRef" href="#bib0520"><span class="elsevierStyleSup">30</span></a>.</p><p id="par0145" class="elsevierStylePara elsevierViewall">La queratotomía arcuata asistida por femtosegundo es más fácil de ejecutar y más segura. Sin embargo, presenta, de forma frecuente, desalineación del eje del astigmatismo. La serie de Chan et al. mostraba un ángulo de error absoluto de 17,5 ± 19,2°, aunque, el ángulo de error promedio fue cercanos a 0°<a class="elsevierStyleCrossRef" href="#bib0525"><span class="elsevierStyleSup">31</span></a>. No obstante, este mismo estudio presentó una estabilidad del resultado refractivo en los 2<span class="elsevierStyleHsp" style=""></span>primeros años. Otra serie presentaba una tasa de corrección del astigmatismo del 63%, con un promedio de 0,63 ± 0,32 dioptrías (rango: 0,0-1,93)<a class="elsevierStyleCrossRef" href="#bib0530"><span class="elsevierStyleSup">32</span></a>.</p></span><span id="sec0030" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0090">Capsulotomía</span><p id="par0150" class="elsevierStylePara elsevierViewall">El LFS ofrece la ventaja de obtener una capsulotomía centrada y bien dimensionada, además de precisa y reproducible<a class="elsevierStyleCrossRefs" href="#bib0535"><span class="elsevierStyleSup">33,34</span></a>. Estas características adquieren importancia en los casos de implante de lentes multifocales y tóricas, en los que el centrado de la lente es importante para obtener un rendimiento visual máximo.</p><p id="par0155" class="elsevierStylePara elsevierViewall">Como contrapartida, se ha descrito un debilitamiento del borde capsular conforme se aumentan los niveles de energía del femtosegundo<a class="elsevierStyleCrossRef" href="#bib0540"><span class="elsevierStyleSup">34</span></a>. Se han realizado estudios experimentales en los que la capsulotomía con LFS presentaba menor resistencia al estrés y una mayor tasa de desgarros radiales anteriores en comparación con la capsulotomía curvilínea continua (CCC)<a class="elsevierStyleCrossRef" href="#bib0545"><span class="elsevierStyleSup">35</span></a>. Daya et al. compararon la resistencia a la rotura entre 3 técnicas de capsulotomía y encontraron una menor resistencia en la hecha con LFS con respecto a las CCC y a la capsulotomía selectiva con láser<a class="elsevierStyleCrossRef" href="#bib0550"><span class="elsevierStyleSup">36</span></a>, que es una técnica más reciente que consiste en un láser selectivo que crea una capsulotomía en un segundo.</p><p id="par0160" class="elsevierStylePara elsevierViewall">Asimismo, la tasa de desgarros capsulares anteriores es mayor en la capsulotomía con LFS (1,84%) que en la CCC manual (0,22%)<a class="elsevierStyleCrossRef" href="#bib0555"><span class="elsevierStyleSup">37</span></a>. Otras series publican tasas de desgarros capsulares anteriores que van del 0,1 al 4,0%<a class="elsevierStyleCrossRefs" href="#bib0560"><span class="elsevierStyleSup">38,39</span></a>.</p><p id="par0165" class="elsevierStylePara elsevierViewall">Las recomendaciones descritas para evitar estirar la capsulotomía y, por tanto, los desgarros, son el uso de piezas de mano de irrigaciónoaspiración bimanuales y anguladas y disminuir los parámetros de facoemulsificación<a class="elsevierStyleCrossRef" href="#bib0570"><span class="elsevierStyleSup">40</span></a>.</p><p id="par0170" class="elsevierStylePara elsevierViewall">Day et al. describen una tasa muy baja (0,1%) de desgarro en capsulotomía anterior con el <span class="elsevierStyleItalic">software</span> actualizado de la plataforma Catalys y lo achacan a las diferencias entre las plataformas<a class="elsevierStyleCrossRef" href="#bib0560"><span class="elsevierStyleSup">38</span></a>.</p><p id="par0175" class="elsevierStylePara elsevierViewall">En algunos estudios mediante microscopia electrónica de barrido en los que se analizaban los bordes de los 2<span class="elsevierStyleHsp" style=""></span>tipos de capsulotomías, se observó que el borde de la capsulotomía con LFS adquiere un patrón de diente de sierra, mientras que el borde de la capsulotomía manual es liso<a class="elsevierStyleCrossRefs" href="#bib0545"><span class="elsevierStyleSup">35,41,42</span></a>. Tal irregularidad podría explicarse por los movimientos oculares mínimos de fijación, ya que se ha descrito la aparición de huellas del láser fuera del lugar de la capsulotomía, en tejido sano<a class="elsevierStyleCrossRef" href="#bib0585"><span class="elsevierStyleSup">43</span></a>.</p><p id="par0180" class="elsevierStylePara elsevierViewall">Por último, otro parámetro analizado fue el tamaño de la capsulotomía. Panthier et al. describieron que el tamaño de la capsulotomía con LFS era más preciso y el diámetro más estable en el primer año tras la cirugía en comparación con la CCC manual<a class="elsevierStyleCrossRef" href="#bib0590"><span class="elsevierStyleSup">44</span></a>. No obstante, este dato no mejoró la posición efectiva de la lente ni la calidad visual.</p></span><span id="sec0035" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0095">Tiempo efectivo de facoemulsificación y afectación del endotelio</span><p id="par0185" class="elsevierStylePara elsevierViewall">El tiempo de aplicación de ultrasonidos condiciona la inflamación intraocular y la pérdida de células endoteliales<a class="elsevierStyleCrossRef" href="#bib0595"><span class="elsevierStyleSup">45</span></a>. Los estudios preliminares de FLACS han demostrado una reducción media en el tiempo efectivo de facoemulsificación del 83,6%. De este 83,6%, hay descrito un 30% de casos con un tiempo efectivo de 0 segundos<a class="elsevierStyleCrossRef" href="#bib0595"><span class="elsevierStyleSup">45</span></a>. Además, se han planteado cambios en los algoritmos del femtosegundo y el uso de una punta de facoemulsificación de calibre 20<span class="elsevierStyleHsp" style=""></span>g para reducir aún más ese tiempo efectivo de facoemulsificación.</p><p id="par0190" class="elsevierStylePara elsevierViewall">Yesilirmak et al. presentaron en sus resultados un menor tiempo efectivo de facoemulsificación en FLACS respecto a la cirugía de catarata comparando grupos de cirujanos expertos y no expertos. También describieron un tiempo total de extracción del núcleo menor en FLACS, con independencia de la experiencia del cirujano<a class="elsevierStyleCrossRef" href="#bib0600"><span class="elsevierStyleSup">46</span></a>.</p><p id="par0195" class="elsevierStylePara elsevierViewall">Con respecto a la afectación endotelial, Conrad-Hengerer et al. evidenciaron una menor pérdida de células en el grupo de FLACS en todos los controles hasta los 3 meses poscirugía; el tiempo efectivo de facoemulsificación también fue menor en este grupo<a class="elsevierStyleCrossRef" href="#bib0605"><span class="elsevierStyleSup">47</span></a>.</p><p id="par0200" class="elsevierStylePara elsevierViewall">Un estudio reciente de Krarup et al. también resultó en una menor pérdida endotelial en FLACS que en cirugía clásica. Compararon los resultados a los 40 y a los 180 días de la cirugía. Se detectó una reducción del 30% en la pérdida de células endoteliales en el día 40 en comparación con la cirugía clásica y una reducción del 21% en el día 180<a class="elsevierStyleCrossRef" href="#bib0610"><span class="elsevierStyleSup">48</span></a>.</p><p id="par0205" class="elsevierStylePara elsevierViewall">La pérdida endotelial tras cirugía FLACS también fue estudiada en pacientes con distrofia endotelial de Fuchs. Concretamente, se analizó la pérdida celular según el grado de dureza de la catarata. De tal forma que, en pacientes con distrofia de Fuchs y catarata leve, el porcentaje medio de pérdida de densidad de células endoteliales fue del 0,9 ± 22,5%. En los casos de catarata moderada o avanzada, el porcentaje medio de pérdida fue del 8,2 ± 26,3%<a class="elsevierStyleCrossRef" href="#bib0615"><span class="elsevierStyleSup">49</span></a>. Si comparamos los grupos de las 2<span class="elsevierStyleHsp" style=""></span>técnicas quirúrgicas, tanto en cataratas leves como avanzadas, la reducción de la pérdida endotelial fue significativamente menor en FLACS que en cirugía convencional<a class="elsevierStyleCrossRef" href="#bib0615"><span class="elsevierStyleSup">49</span></a>. Todos estos datos nos llevan a la conclusión de que los pacientes con recuentos celulares bajos pueden verse beneficiados de la técnica FLACS.</p></span><span id="sec0040" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0100">Tamaño pupilar durante la cirugía</span><p id="par0210" class="elsevierStylePara elsevierViewall">En general, en la cirugía de catarata, una condición deseada por los cirujanos es una óptima dilatación pupilar. En la FLACS se ha descrito miosis intraoperatoria, a pesar de los midriáticos utilizados previos a la cirugía. Nagy et al. describieron una tasa de miosis intraoperatoria del 32%<a class="elsevierStyleCrossRef" href="#bib0565"><span class="elsevierStyleSup">39</span></a>. La miosis en la FLACS se relaciona con la liberación de prostaglandinas en la cámara anterior<a class="elsevierStyleCrossRefs" href="#bib0620"><span class="elsevierStyleSup">50-52</span></a> y el nivel de la miosis se correlaciona con la liberación de la interleucina 6<a class="elsevierStyleCrossRef" href="#bib0635"><span class="elsevierStyleSup">53</span></a>. Se ha evidenciado que a mayor tiempo de tratamiento con láser y a mayor edad del paciente, mayor es la miosis intraoperatoria<a class="elsevierStyleCrossRef" href="#bib0640"><span class="elsevierStyleSup">54</span></a>. Asimismo, otros factores de riesgo son: distancia corta entre la pupila y la capsulotomía, poca profundidad de la cámara anterior, tamaño pupilar previo menor y un tiempo de succión largo<a class="elsevierStyleCrossRef" href="#bib0645"><span class="elsevierStyleSup">55</span></a>.</p><p id="par0215" class="elsevierStylePara elsevierViewall">Los antiinflamatorios no esteroideos previos a la cirugía se han considerados preventivos de esta situación<a class="elsevierStyleCrossRefs" href="#bib0635"><span class="elsevierStyleSup">53,56</span></a>. Anisimova et al. compararon concretamente el bromfenaco al 0,9% con la indometacina al 0,1%: el primero resultó mejor mantenedor de la midriasis<a class="elsevierStyleCrossRef" href="#bib0635"><span class="elsevierStyleSup">53</span></a>. Walter et al. propusieron agregar 4<span class="elsevierStyleHsp" style=""></span>ml de fenilefrina al 0,1% y ketorolaco al 0,3% a la solución de irrigación ocular de 500<span class="elsevierStyleHsp" style=""></span>ml, lo que redujo el tiempo quirúrgico y la necesidad de usar dispositivos de expansión de la pupila en cirugía FLACS<a class="elsevierStyleCrossRef" href="#bib0620"><span class="elsevierStyleSup">50</span></a>.</p></span></span><span id="sec0045" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0105">Ventajas e inconvenientes postoperatorios de la cirugía de la catarata asistida con láser femtosegundo</span><p id="par0220" class="elsevierStylePara elsevierViewall">En la <a class="elsevierStyleCrossRef" href="#tbl0010">tabla 2</a> presentamos la prevalencia de complicaciones postoperatorias de FLACS.</p><elsevierMultimedia ident="tbl0010"></elsevierMultimedia><span id="sec0050" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0110">Edema macular quístico pseudofáquico</span><p id="par0225" class="elsevierStylePara elsevierViewall">El edema macular quístico pseudofáquico (EMQP) es una de las complicaciones más frecuentes de la cirugía de cataratas y en la mayoría de los casos conlleva una pérdida de agudeza visual postoperatoria<a class="elsevierStyleCrossRef" href="#bib0660"><span class="elsevierStyleSup">58</span></a>.</p><p id="par0230" class="elsevierStylePara elsevierViewall">La mayoría de los investigadores coinciden en que el EMQP es consecuencia de la inflamación postoperatoria. Las maniobras quirúrgicas en la cámara anterior parecen producir liberación de ácido araquidónico del tejido uveal, con la consecuente producción de leucotrienos y prostaglandinas por la acción de las enzimas lipooxigenasa y ciclooxigenasa, respectivamente. Estas sustancias inflamatorias se difunden en el vítreo, provocan la rotura de la barrera hematoencefálica y aumentan la permeabilidad de los capilares perifoveales, con el acúmulo de líquido intrarretiniano macular<a class="elsevierStyleCrossRef" href="#bib0665"><span class="elsevierStyleSup">59</span></a>.</p><p id="par0235" class="elsevierStylePara elsevierViewall">La aplicación de una energía diferente a los ultrasonidos ha generado mayor preocupación sobre la aparición del EMQP en FLACS.</p><p id="par0240" class="elsevierStylePara elsevierViewall">Ewe et al. en 2015 no encontraron diferencia estadísticamente significativa en la tasa de EMQP en FLACS (0,8%) con la cirugía manual (0,2%; <span class="elsevierStyleItalic">p</span> = 0,07)<a class="elsevierStyleCrossRef" href="#bib0670"><span class="elsevierStyleSup">60</span></a>. Este mismo grupo en 2016 sí encontró diferencias entre los grupos e informó de una tasa del 0,81% de EMQP en FLACS y de 0,1% en cirugía manual con una <span class="elsevierStyleItalic">p</span> = 0,41<a class="elsevierStyleCrossRef" href="#bib0675"><span class="elsevierStyleSup">61</span></a>.</p><p id="par0245" class="elsevierStylePara elsevierViewall">Conrad-Hengerer et al.<a class="elsevierStyleCrossRef" href="#bib0680"><span class="elsevierStyleSup">62</span></a> no encontraron diferencias en el EMQP entre FLACS y cirugía manual.</p><p id="par0250" class="elsevierStylePara elsevierViewall">Otros investigadores como Levitz et al. analizaron el EMQP con tomografía de coherencia óptica y un seguimiento de 2 a 24 meses. Los resultados no fueron estadísticamente significativos. Describieron que el EMQP apareció en 7 de 713 ojos (0,98%) en el grupo cirugía manual y en 8 de 677 ojos (1,18%) en el grupo FLACS<a class="elsevierStyleCrossRef" href="#bib0685"><span class="elsevierStyleSup">63</span></a>.</p><p id="par0255" class="elsevierStylePara elsevierViewall">Por último, en la revisión Cochrane no fue posible determinar la equivalencia o superioridad, ya que los resultados no fueron concluyentes<a class="elsevierStyleCrossRef" href="#bib0690"><span class="elsevierStyleSup">64</span></a>. El riesgo de desarrollar EMQP fue menor en FLACS que en la cirugía de catarata clásica, con un cociente de probabilidades del 0,58 (confianza del 95% intervalo de 0,20 a 1,68). No obstante, la evidencia fue baja.</p></span><span id="sec0055" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0115">Opacificación capsular posterior</span><p id="par0260" class="elsevierStylePara elsevierViewall">La opacificación capsular posterior es una complicación de la cirugía de catarata que puede aparecer desde meses hasta años después de la intervención. Rostami et al. realizaron un estudio restrospectivo comparativo de 29 casos de FLACS y 50 casos de cirugía convencional y evidenciaron una mayor tasa de opacificación capsular posterior en FLACS que en cirugía clásica a los 3 meses tras la cirugía (7 de 29 casos FLACS vs. 0 casos en cirugía clásica)<a class="elsevierStyleCrossRef" href="#bib0695"><span class="elsevierStyleSup">65</span></a>. La justificación la encuentran en la curva de aprendizaje de FLACS, ya que en esa etapa de formación no se hace el pulido de la cápsula anterior. Otro motivo es el posible daño termomecánico de las células epiteliales del cristalino.</p><p id="par0265" class="elsevierStylePara elsevierViewall">Sin embargo, Manning et al. no confirmaron tasas tan altas de opacificación capsular posterior temprana en FLACS, aunque esa tasa en su estudio seguía superando a la de la cirugía clásica (09% en FLACS vs. 0,0% en cirugía de facoemulsificación de la catarata [PCS])<a class="elsevierStyleCrossRef" href="#bib0445"><span class="elsevierStyleSup">15</span></a>.</p></span><span id="sec0060" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0120">Resultado visual</span><p id="par0270" class="elsevierStylePara elsevierViewall">Vasavada et al. compararon los resultados en ojos con cámara anterior poco profunda (<2,5<span class="elsevierStyleHsp" style=""></span>mm) y encontraron menos edema corneal e inflamación en los días 1 y 7 del postoperatorio en FLACS que en cirugía convencional<a class="elsevierStyleCrossRef" href="#bib0700"><span class="elsevierStyleSup">66</span></a>.</p><p id="par0275" class="elsevierStylePara elsevierViewall">Un metaanálisis de 2016 describió un menor error refractivo postoperatorio en FLACS. Sin embargo, no se encontraron diferencias entre la máxima agudeza visual corregida final y el astigmatismo quirúrgico entre las 2<span class="elsevierStyleHsp" style=""></span>técnicas<a class="elsevierStyleCrossRef" href="#bib0705"><span class="elsevierStyleSup">67</span></a>.</p><p id="par0280" class="elsevierStylePara elsevierViewall">Los datos del Registro Europeo de Resultados de Calidad para la base de datos de Cataratas y Cirugía Refractiva no describieron un mejor resultado visual o refractivo en FLACS que en cirugía clásica<a class="elsevierStyleCrossRef" href="#bib0445"><span class="elsevierStyleSup">15</span></a>. Asimismo, Berk, en 2018, tampoco encontró diferencias en los resultados visuales y refractivos tras comparar 1.089 ojos de FLACS con 883 ojos con cirugía manual<a class="elsevierStyleCrossRef" href="#bib0710"><span class="elsevierStyleSup">68</span></a>.</p><p id="par0285" class="elsevierStylePara elsevierViewall">Por último, la evaluación económica de la cirugía de cataratas asistida por láser femtosegundo o FEMCAT, realizada en Francia y que involucró a 16 centros clínicos y 1.400 ojos de 870 pacientes, no informó de diferencias en los resultados clínicos generales (tasa de complicaciones, agudeza visual postoperatoria, error refractivo y cambio del astigmatismo corneal) entre FLACS y cirugía manual<a class="elsevierStyleCrossRef" href="#bib0715"><span class="elsevierStyleSup">69</span></a>. En general, describió una tendencia hacia mejores resultados para cataratas de menor grado en el grupo FLACS y una tendencia hacia mejores resultados para cataratas de mayor grado en el grupo de cirugía clásica. Asimismo, el tiempo medio total de ultrasonido y la energía disipada fueron menores en FLACS, tanto para cataratas de grado inferior como superior. Sin embargo, el tiempo medio de aspiración y el volumen de solución salina balanceada fueron significativamente mayores en FLACS.</p></span></span><span id="sec0065" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0125">Balance coste/eficacia de la técnica</span><p id="par0290" class="elsevierStylePara elsevierViewall">Debemos analizar varios puntos para determinar el coste-efectividad por paciente en FLACS.</p><p id="par0295" class="elsevierStylePara elsevierViewall">En primer lugar, el coste de adquisición del LFS y su mantenimiento posterior. Como sabemos, existen diferentes plataformas de LFS, en algunas es posible efectuar tanto la cirugía de catarata como el colgajo corneal del Lasik (LenSx [ALCON Laboratorios, Fort Worth, TX, EE. UU.], Victus [Bausch & Lomb Incorporated, Bridgewater, NJ, EE.UU.], LDV Z8 [Ziemer Ophthalmic Systems, Port, Suiza]). Sin embargo, otras como el sistema Catalys (Johnson & Johnson Vision, Santa Ana, CA, EE.UU.) y el sistema Lensar no son capaces de crear colgajos para Lasik. Existen otros láseres que están dedicados a la creación del colgado corneal y no hacen FLACS, este último es el Ziemer Femto LDV Z2/Z4/Z6 (Ziemer Ophthalmic Systems, Port, Suiza). Roberts et al. en su estudio de coste-efectividad del LFS vs. cirugía clásica informaron que la interfaz del paciente que es desechable supone el 27% del coste total, gasto este que no se ve disminuido por una mayor productividad<a class="elsevierStyleCrossRef" href="#bib0720"><span class="elsevierStyleSup">70</span></a>.</p><p id="par0300" class="elsevierStylePara elsevierViewall">Hay que considerar también que FLACS puede requerir un personal técnico capacitado y que favorezca el flujo de trabajo con la plataforma, hecho que inicialmente puede subir el coste<a class="elsevierStyleCrossRef" href="#bib0720"><span class="elsevierStyleSup">70</span></a>.</p><p id="par0305" class="elsevierStylePara elsevierViewall">Otro problema es el tiempo de duración de FLACS. En un estudio de Lubahn et al. las cirugías asistidas por femtosegundo fueron 11,1-12,1 min más largas que la técnica clásica<a class="elsevierStyleCrossRef" href="#bib0725"><span class="elsevierStyleSup">71</span></a>. El tiempo quirúrgico disminuyó con cirujanos más experimentados, pero, a pesar de ello, la FLACS seguía siendo más larga que la cirugía clásica<a class="elsevierStyleCrossRef" href="#bib0490"><span class="elsevierStyleSup">24</span></a>.</p><p id="par0310" class="elsevierStylePara elsevierViewall">La cirugía FLACS tiene pasos quirúrgicos adicionales que pueden aumentar la duración total de la cirugía. Chang et al. describieron el tiempo que les ocupó el paso inicial de la cirugía, con el acoplamiento y hasta la succión. Este fue de 6,72 ± 4,57 min (rango: 2-28 min)<a class="elsevierStyleCrossRef" href="#bib0730"><span class="elsevierStyleSup">72</span></a>.</p><p id="par0315" class="elsevierStylePara elsevierViewall">Podemos concluir que los beneficios de FLACS no son evidentes por el momento. Mientras que los beneficios visuales todavía deben demostrarse de manera concluyente, el elevado costo de la tecnología implicada supone un importante sobrecoste del proceso quirúrgico de la operación de cataratas. A la luz de la más reciente literatura, debe considerarse el coste que supone la técnica FLACS tanto para el centro como para el paciente, en el caso de la medicina privada, que no es rentable desde la perspectiva coste/eficacia<a class="elsevierStyleCrossRef" href="#bib0735"><span class="elsevierStyleSup">73</span></a>.</p><p id="par0320" class="elsevierStylePara elsevierViewall">Para lograr la rentabilidad coste/eficacia, la técnica FLACS debería reducir significativamente la tasa de complicaciones y el coste para los pacientes<a class="elsevierStyleCrossRef" href="#bib0740"><span class="elsevierStyleSup">74</span></a>.</p></span><span id="sec0070" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0130">Conclusión</span><p id="par0325" class="elsevierStylePara elsevierViewall">Tras el análisis de múltiples artículos sobre FLACS disponibles en la literatura científica, exponemos en la <a class="elsevierStyleCrossRef" href="#tbl0015">tabla 3</a> los beneficios y las desventajas de la técnica.</p><elsevierMultimedia ident="tbl0015"></elsevierMultimedia><p id="par0330" class="elsevierStylePara elsevierViewall">Podemos concluir que la cirugía FLACS es más beneficiosa en determinados casos, como son los pacientes con recuento endotelial bajo o los que eligen una lente intraocular multifocal. Sin embargo, considerando los casos más frecuentes y rutinarios de nuestra práctica clínica, los beneficios podrían no ser claros. Por tanto, FLACS no puede considerarse como técnica rentable desde el punto de vista de coste/eficacia.</p></span><span id="sec0075" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0135">Financiación</span><p id="par0335" class="elsevierStylePara elsevierViewall">Esta publicación ha sido subvencionada en parte por la Red Temática de Investigación Cooperativa en Salud «OFTARED» (referencia: RD16/0008/0012). Financiada por el Instituto de Salud Carlos III/Agencia Estatal de Investigación y por el Fondo Europeo de Desarrollo Regional (FEDER) «Una manera de hacer Europa».</p></span><span id="sec0080" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0140">Conflicto de intereses</span><p id="par0340" class="elsevierStylePara elsevierViewall">Los autores no tienen interés de propiedad o comercial en la tecnología descrita en este manuscrito.</p><p id="par0345" class="elsevierStylePara elsevierViewall">El Dr. Kanclerz declara apoyo no financiero de Visim y Optopol Technologies (Polonia).</p></span></span>" "textoCompletoSecciones" => array:1 [ "secciones" => array:13 [ 0 => array:3 [ "identificador" => "xres1560961" "titulo" => "Resumen" "secciones" => array:4 [ 0 => array:2 [ "identificador" => "abst0005" "titulo" => "Introducción" ] 1 => array:2 [ "identificador" => "abst0010" "titulo" => "Método" ] 2 => array:2 [ "identificador" => "abst0015" "titulo" => "Resultados" ] 3 => array:2 [ "identificador" => "abst0020" "titulo" => "Conclusiones" ] ] ] 1 => array:2 [ "identificador" => "xpalclavsec1407920" "titulo" => "Palabras clave" ] 2 => array:3 [ "identificador" => "xres1560962" "titulo" => "Abstract" "secciones" => array:4 [ 0 => array:2 [ "identificador" => "abst0025" "titulo" => "Introduction" ] 1 => array:2 [ "identificador" => "abst0030" "titulo" => "Method" ] 2 => array:2 [ "identificador" => "abst0035" "titulo" => "Results" ] 3 => array:2 [ "identificador" => "abst0040" "titulo" => "Conclusions" ] ] ] 3 => array:2 [ "identificador" => "xpalclavsec1407919" "titulo" => "Keywords" ] 4 => array:2 [ "identificador" => "sec0005" "titulo" => "Introducción" ] 5 => array:2 [ "identificador" => "sec0010" "titulo" => "Método de análisis de la literatura" ] 6 => array:3 [ "identificador" => "sec0015" "titulo" => "Ventajas e inconvenientes intraoperatorios de la cirugía de la catarata asistida con láser femtosegundo" "secciones" => array:5 [ 0 => array:2 [ "identificador" => "sec0020" "titulo" => "Complicaciones asociadas con el acoplamiento láser" ] 1 => array:2 [ "identificador" => "sec0025" "titulo" => "Incisiones corneales" ] 2 => array:2 [ "identificador" => "sec0030" "titulo" => "Capsulotomía" ] 3 => array:2 [ "identificador" => "sec0035" "titulo" => "Tiempo efectivo de facoemulsificación y afectación del endotelio" ] 4 => array:2 [ "identificador" => "sec0040" "titulo" => "Tamaño pupilar durante la cirugía" ] ] ] 7 => array:3 [ "identificador" => "sec0045" "titulo" => "Ventajas e inconvenientes postoperatorios de la cirugía de la catarata asistida con láser femtosegundo" "secciones" => array:3 [ 0 => array:2 [ "identificador" => "sec0050" "titulo" => "Edema macular quístico pseudofáquico" ] 1 => array:2 [ "identificador" => "sec0055" "titulo" => "Opacificación capsular posterior" ] 2 => array:2 [ "identificador" => "sec0060" "titulo" => "Resultado visual" ] ] ] 8 => array:2 [ "identificador" => "sec0065" "titulo" => "Balance coste/eficacia de la técnica" ] 9 => array:2 [ "identificador" => "sec0070" "titulo" => "Conclusión" ] 10 => array:2 [ "identificador" => "sec0075" "titulo" => "Financiación" ] 11 => array:2 [ "identificador" => "sec0080" "titulo" => "Conflicto de intereses" ] 12 => array:1 [ "titulo" => "Bibliografía" ] ] ] "pdfFichero" => "main.pdf" "tienePdf" => true "fechaRecibido" => "2020-02-12" "fechaAceptado" => "2020-05-25" "PalabrasClave" => array:2 [ "es" => array:1 [ 0 => array:4 [ "clase" => "keyword" "titulo" => "Palabras clave" "identificador" => "xpalclavsec1407920" "palabras" => array:3 [ 0 => "Cirugía de catarata asistida por láser de femtosegundo" 1 => "Cirugía de cataratas por facoemulsificación" 2 => "Incisiones corneales" ] ] ] "en" => array:1 [ 0 => array:4 [ "clase" => "keyword" "titulo" => "Keywords" "identificador" => "xpalclavsec1407919" "palabras" => array:3 [ 0 => "Femtosecond laser-assisted cataract surgery" 1 => "Cataract surgery by phacoemulsification" 2 => "Corneal incisions" ] ] ] ] "tieneResumen" => true "resumen" => array:2 [ "es" => array:3 [ "titulo" => "Resumen" "resumen" => "<span id="abst0005" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0010">Introducción</span><p id="spar0005" class="elsevierStyleSimplePara elsevierViewall">La cirugía de la catarata asistida con el láser femtosegundo (FLACS) se ha considerado un avance tecnológico en la cirugía moderna de la catarata. Tras los años de experiencia, se ha observado que los resultados clínicos presentan más complicaciones de las esperadas al inicio. Con este estudio queremos comparar los beneficios e inconvenientes de la técnica FLACS con la cirugía de catarata convencional.</p></span> <span id="abst0010" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0015">Método</span><p id="spar0010" class="elsevierStyleSimplePara elsevierViewall">Utilizamos las plataformas PubMed y Web of Science para la búsqueda de la literatura científica.</p></span> <span id="abst0015" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0020">Resultados</span><p id="spar0015" class="elsevierStyleSimplePara elsevierViewall">Actualmente, el FLACS ha mejorado la técnica quirúrgica en cuanto al menor tiempo de ultrasonidos empleado y a la menor pérdida de células endoteliales. Asimismo, el centrado de la capsulotomía y la corrección del astigmatismo con las incisiones arqueadas han mejorado. Como inconvenientes destacan el alto coste del láser, las complicaciones intraoperatorias sobre la cápsula, la inducción de miosis intraoperatoria y la curva de aprendizaje de la técnica.</p></span> <span id="abst0020" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0025">Conclusiones</span><p id="spar0020" class="elsevierStyleSimplePara elsevierViewall">Consideramos la técnica FLACS beneficiosa para casos concretos como pacientes con cirugía premium programada o con bajo recuento de células endoteliales. No obstante, creemos que, dado el coste tecnológico, no es una técnica rentable para la mayoría de los casos de nuestra práctica clínica diaria, que son casos estándares.</p></span>" "secciones" => array:4 [ 0 => array:2 [ "identificador" => "abst0005" "titulo" => "Introducción" ] 1 => array:2 [ "identificador" => "abst0010" "titulo" => "Método" ] 2 => array:2 [ "identificador" => "abst0015" "titulo" => "Resultados" ] 3 => array:2 [ "identificador" => "abst0020" "titulo" => "Conclusiones" ] ] ] "en" => array:3 [ "titulo" => "Abstract" "resumen" => "<span id="abst0025" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0035">Introduction</span><p id="spar0025" class="elsevierStyleSimplePara elsevierViewall">Femtosecond laser-assisted cataract surgery (FLACS) has been considered a technological advance in modern cataract surgery. After years of experience, it has been observed that clinical outcomes had more complications than expected at the beginning. The aim of this study is to compare the benefits and disadvantages of the FLACS technique with conventional cataract surgery.</p></span> <span id="abst0030" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0040">Method</span><p id="spar0030" class="elsevierStyleSimplePara elsevierViewall">The PubMed and Web of Science platforms were used to search for scientific literature.</p></span> <span id="abst0035" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0045">Results</span><p id="spar0035" class="elsevierStyleSimplePara elsevierViewall">The FLACS has currently improved the surgical technique in terms of the shorter ultrasound time used and the lower loss of endothelial cells. Likewise, the centration of capsulotomy and the correction of astigmatism with arcuate incisions have also been improved. As disadvantages, are the high cost of the laser, the intraoperative capsular complications, the induction of intraoperative myosis, and the learning curve of the technique.</p></span> <span id="abst0040" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0050">Conclusions</span><p id="spar0040" class="elsevierStyleSimplePara elsevierViewall">The FLACS technique is considered beneficial for specific cases, such as patients with scheduled premium surgery, or with low endothelial cell count. However, it is believed that given the technological cost it is not a cost effective technique for most standard cases in our daily clinical practice.</p></span>" "secciones" => array:4 [ 0 => array:2 [ "identificador" => "abst0025" "titulo" => "Introduction" ] 1 => array:2 [ "identificador" => "abst0030" "titulo" => "Method" ] 2 => array:2 [ "identificador" => "abst0035" "titulo" => "Results" ] 3 => array:2 [ "identificador" => "abst0040" "titulo" => "Conclusions" ] ] ] ] "multimedia" => array:3 [ 0 => array:8 [ "identificador" => "tbl0005" "etiqueta" => "Tabla 1" "tipo" => "MULTIMEDIATABLA" "mostrarFloat" => true "mostrarDisplay" => false "detalles" => array:1 [ 0 => array:3 [ "identificador" => "at1" "detalle" => "Tabla " "rol" => "short" ] ] "tabla" => array:3 [ "leyenda" => "<p id="spar0050" class="elsevierStyleSimplePara elsevierViewall">CCF: cirugía de catarata mediante facoemulsificación; FLACS: cirugía de catarata asistida con láser femtosegundo; LIO: lente intraocular; N/A: no disponible.</p>" "tablatextoimagen" => array:1 [ 0 => array:2 [ "tabla" => array:1 [ 0 => """ <table border="0" frame="\n \t\t\t\t\tvoid\n \t\t\t\t" class=""><thead title="thead"><tr title="table-row"><th class="td-with-role" title="\n \t\t\t\t\ttable-head\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col">Método \t\t\t\t\t\t\n \t\t\t\t\t\t</th><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " colspan="2" align="center" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">CCF en %</th><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " colspan="2" align="center" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">FLACS en %</th></tr><tr title="table-row"><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">Estudio \t\t\t\t\t\t\n \t\t\t\t\t\t</th><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="center" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">Syed et al., 2015<a class="elsevierStyleCrossRef" href="#bib0435"><span class="elsevierStyleSup">13</span></a> (n = 20.070) \t\t\t\t\t\t\n \t\t\t\t\t\t</th><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="center" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">Jaycock et al., 2009<a class="elsevierStyleCrossRef" href="#bib0440"><span class="elsevierStyleSup">14</span></a> (n = 55.567) \t\t\t\t\t\t\n \t\t\t\t\t\t</th><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="center" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">Roberts et al., 2013<a class="elsevierStyleCrossRef" href="#bib0430"><span class="elsevierStyleSup">12</span></a> (n = 1.300)<a class="elsevierStyleCrossRef" href="#tblfn0005"><span class="elsevierStyleSup">a</span></a> \t\t\t\t\t\t\n \t\t\t\t\t\t</th><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="center" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">Manning et al., 2016<a class="elsevierStyleCrossRef" href="#bib0445"><span class="elsevierStyleSup">15</span></a> (n = 2.814) \t\t\t\t\t\t\n \t\t\t\t\t\t</th></tr></thead><tbody title="tbody"><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Desgarros radiales anteriores \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A (FLACS-specific) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="" valign="\n \t\t\t\t\ttop\n \t\t\t\t"> \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,31 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,5 \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Marca en cápsula anterior \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="" valign="\n \t\t\t\t\ttop\n \t\t\t\t"> \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="" valign="\n \t\t\t\t\ttop\n \t\t\t\t"> \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,31 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,5<a class="elsevierStyleCrossRef" href="#tblfn0010"><span class="elsevierStyleSup">b</span></a> \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Miosis pupilar \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="" valign="\n \t\t\t\t\ttop\n \t\t\t\t"> \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="" valign="\n \t\t\t\t\ttop\n \t\t\t\t"> \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">1,23 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Pérdida de succión o abandono de procedimiento \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="" valign="\n \t\t\t\t\ttop\n \t\t\t\t"> \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="" valign="\n \t\t\t\t\ttop\n \t\t\t\t"> \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,61 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,1 \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Incisión corneal manual \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="" valign="\n \t\t\t\t\ttop\n \t\t\t\t"> \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="" valign="\n \t\t\t\t\ttop\n \t\t\t\t"> \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">1,92 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,9 \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Puentes capsulares o capsulotomía incompleta \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="" valign="\n \t\t\t\t\ttop\n \t\t\t\t"> \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="" valign="\n \t\t\t\t\ttop\n \t\t\t\t"> \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,4 \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Rotura de cápsula posterior con o sin pérdida vítrea \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,53 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">1,92 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,31 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,4 \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Complicaciones de la LIO(descentramientos, explante) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,05 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,01 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,00 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Diálisis zonular \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,10 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,46 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Caída de nucleo \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,1 \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Trauma iridiano o prolapso de iris \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,55 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A \t\t\t\t\t\t\n \t\t\t\t</td></tr></tbody></table> """ ] "imagenFichero" => array:1 [ 0 => "xTab2674824.png" ] ] ] "notaPie" => array:2 [ 0 => array:3 [ "identificador" => "tblfn0005" "etiqueta" => "a" "nota" => "<p class="elsevierStyleNotepara" id="npar0005">Tras los primeros 200 casos.</p>" ] 1 => array:3 [ "identificador" => "tblfn0010" "etiqueta" => "b" "nota" => "<p class="elsevierStyleNotepara" id="npar0010">Incluye las menores.</p>" ] ] ] "descripcion" => array:1 [ "es" => "<p id="spar0045" class="elsevierStyleSimplePara elsevierViewall">Prevalencia de complicaciones intraoperatorias en la cirugía de cataratas por facoemulsificación y cirugía de cataratas asistida por láser de femtosegundos en estudios de cohortes seleccionados</p>" ] ] 1 => array:8 [ "identificador" => "tbl0010" "etiqueta" => "Tabla 2" "tipo" => "MULTIMEDIATABLA" "mostrarFloat" => true "mostrarDisplay" => false "detalles" => array:1 [ 0 => array:3 [ "identificador" => "at2" "detalle" => "Tabla " "rol" => "short" ] ] "tabla" => array:2 [ "leyenda" => "<p id="spar0060" class="elsevierStyleSimplePara elsevierViewall">CCF: cirugía de catarata mediante facoemulsificación; LIO: lente intraocular; N/A: no disponible; PIO: presión intraocular.</p>" "tablatextoimagen" => array:1 [ 0 => array:2 [ "tabla" => array:1 [ 0 => """ <table border="0" frame="\n \t\t\t\t\tvoid\n \t\t\t\t" class=""><thead title="thead"><tr title="table-row"><th class="td-with-role" title="\n \t\t\t\t\ttable-head\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col">Método \t\t\t\t\t\t\n \t\t\t\t\t\t</th><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " colspan="3" align="center" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">CCF en %</th><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="center" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col">FLACS \t\t\t\t\t\t\n \t\t\t\t\t\t</th></tr><tr title="table-row"><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">Estudio \t\t\t\t\t\t\n \t\t\t\t\t\t</th><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="center" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">Jaycock et al., 2009<a class="elsevierStyleCrossRef" href="#bib0440"><span class="elsevierStyleSup">14</span></a> (n = 16.731) \t\t\t\t\t\t\n \t\t\t\t\t\t</th><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="center" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">Syed et al., 2015<a class="elsevierStyleCrossRef" href="#bib0435"><span class="elsevierStyleSup">13</span></a> (n = 20.070) \t\t\t\t\t\t\n \t\t\t\t\t\t</th><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="center" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">Greenberg et al., 2011<a class="elsevierStyleCrossRef" href="#bib0655"><span class="elsevierStyleSup">57</span></a> (n = 45.082) \t\t\t\t\t\t\n \t\t\t\t\t\t</th><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="center" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">Manning et al., 2016<a class="elsevierStyleCrossRef" href="#bib0445"><span class="elsevierStyleSup">15</span></a>(n = 2.814) \t\t\t\t\t\t\n \t\t\t\t\t\t</th></tr></thead><tbody title="tbody"><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Opacificación de cápsula posterior \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">1,22 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,34 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">4,2 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,9 \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">o edema corneal/estrías/pliegues en Descemet \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">5,18 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,59 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,5 \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Uveítis postoperatoria \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">3,29 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,24 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,5 \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Aumento de PIO(>21 mmHg) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">2,57 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,31 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,2 \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Descentramiento de LIO o luxación o intercambio \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,22 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,9 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,0 \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Edema macular quístico \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">1,62 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,22 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">3,3 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Prolapso de iris o iris anclado en herida \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,16 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,04 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Retención de restos corticales \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,45 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,19 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">1,7 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Vítreo \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,39 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,09 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Incisión no estanca \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,14 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,02 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Efusión coroidea o hemorragia \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,13 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,1 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Hifema \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,07 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,2 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Hipopion o endoftalmitis \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,04 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,2 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Desgarro retiniano o desprendimiento \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,03 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">1,0 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Hemorragia vítrea \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,01 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,4 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Hipotonía \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">0,1 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">N/A \t\t\t\t\t\t\n \t\t\t\t</td></tr></tbody></table> """ ] "imagenFichero" => array:1 [ 0 => "xTab2674823.png" ] ] ] ] "descripcion" => array:1 [ "es" => "<p id="spar0055" class="elsevierStyleSimplePara elsevierViewall">Prevalencia de las complicaciones postoperatorias en cirugía de cataratas por facoemulsificación y cirugía de cataratas asistida por láser de femtosegundo en estudios de cohortes seleccionados</p>" ] ] 2 => array:8 [ "identificador" => "tbl0015" "etiqueta" => "Tabla 3" "tipo" => "MULTIMEDIATABLA" "mostrarFloat" => true "mostrarDisplay" => false "detalles" => array:1 [ 0 => array:3 [ "identificador" => "at3" "detalle" => "Tabla " "rol" => "short" ] ] "tabla" => array:2 [ "leyenda" => "<p id="spar0070" class="elsevierStyleSimplePara elsevierViewall">FLACS: cirugía de catarata asistida con láser femtosegundo.</p>" "tablatextoimagen" => array:1 [ 0 => array:2 [ "tabla" => array:1 [ 0 => """ <table border="0" frame="\n \t\t\t\t\tvoid\n \t\t\t\t" class=""><thead title="thead"><tr title="table-row"><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">Beneficios \t\t\t\t\t\t\n \t\t\t\t\t\t</th><th class="td" title="\n \t\t\t\t\ttable-head\n \t\t\t\t " align="center" valign="\n \t\t\t\t\ttop\n \t\t\t\t" scope="col" style="border-bottom: 2px solid black">Inconvenientes \t\t\t\t\t\t\n \t\t\t\t\t\t</th></tr></thead><tbody title="tbody"><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Menor tiempo de facoemulsificación y menor pérdida endotelial \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Coste del láser/desechables \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Centrado perfecto de la capsulotomía \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Complicaciones intraoperatorias específicas de la capsulotomía en FLACS \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t ; entry_with_role_rowhead " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Posibilidad de realizar queratotomía arcuata asistida con femtoláser \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Riesgo intraoperatorio de miosis \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="" valign="\n \t\t\t\t\ttop\n \t\t\t\t"> \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="\n \t\t\t\t\ttable-entry\n \t\t\t\t " align="left" valign="\n \t\t\t\t\ttop\n \t\t\t\t">Curva de aprendizaje \t\t\t\t\t\t\n \t\t\t\t</td></tr></tbody></table> """ ] "imagenFichero" => array:1 [ 0 => "xTab2674825.png" ] ] ] ] "descripcion" => array:1 [ "es" => "<p id="spar0065" class="elsevierStyleSimplePara elsevierViewall">Beneficios e inconvenientes de la cirugía de cataratas asistida por láser de femtosegundo</p>" ] ] ] "bibliografia" => array:2 [ "titulo" => "Bibliografía" "seccion" => array:1 [ 0 => array:2 [ "identificador" => "bibs0015" "bibliografiaReferencia" => array:74 [ 0 => array:3 [ "identificador" => "bib0375" "etiqueta" => "1" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Femtosecond laser tissue interactions: Retinal injury studies" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:6 [ 0 => "R. Birngruber" 1 => "C.A. Puliafito" 2 => "A. Gawande" 3 => "W.Z. Lin" 4 => "R.W. Schoenlein" 5 => "J.G. Fujimoto" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:5 [ "tituloSerie" => "IEEE J Quantum Electron." "fecha" => "1987" "volumen" => "23" "paginaInicial" => "1836" "paginaFinal" => "1844" ] ] ] ] ] ] 1 => array:3 [ "identificador" => "bib0380" "etiqueta" => "2" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Corneal ablation by nanosecond picosecond, and femtosecond lasers at 532 and 625<span class="elsevierStyleHsp" style=""></span>nm" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:6 [ 0 => "D. Stern" 1 => "R.W. Schoenlein" 2 => "C.A. Puliafito" 3 => "E.T. Dobi" 4 => "R. Birngruber" 5 => "J.G. Fujimoto" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1001/archopht.1989.01070010601038" "Revista" => array:6 [ "tituloSerie" => "Arch Ophthalmol." "fecha" => "1989" "volumen" => "107" "paginaInicial" => "587" "paginaFinal" => "592" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/2705929" "web" => "Medline" ] ] ] ] ] ] ] ] 2 => array:3 [ "identificador" => "bib0385" "etiqueta" => "3" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Comparative studies of femtosecond to microsecond laser pulses on selective pigmented cell injury in skin" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:6 [ 0 => "S. Watanabe" 1 => "R.R. Anderson" 2 => "S. Brorson" 3 => "G. Dalickas" 4 => "J.G. Fujimoto" 5 => "T.J. Flotte" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1111/j.1751-1097.1991.tb09889.x" "Revista" => array:6 [ "tituloSerie" => "Photochem. Photobiol." "fecha" => "1991" "volumen" => "53" "paginaInicial" => "757" "paginaFinal" => "762" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/1886935" "web" => "Medline" ] ] ] ] ] ] ] ] 3 => array:3 [ "identificador" => "bib0390" "etiqueta" => "4" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Surgical applications of femtosecond lasers" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:2 [ 0 => "S.H. Chung" 1 => "E. Mazur" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:5 [ "tituloSerie" => "J Biophoton." "fecha" => "2009" "volumen" => "2" "paginaInicial" => "557" "paginaFinal" => "572" ] ] ] ] ] ] 4 => array:3 [ "identificador" => "bib0395" "etiqueta" => "5" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Corneal refractive surgery with femtosecond lasers" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:6 [ 0 => "T. Juhasz" 1 => "T.H. Frieder" 2 => "R.M. Kurtz" 3 => "C. Horvath" 4 => "J.F. Bille" 5 => "G. Mourou" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:5 [ "tituloSerie" => "IEEE J Sel Top Quantum Electron" "fecha" => "1999" "volumen" => "5" "paginaInicial" => "902" "paginaFinal" => "910" ] ] ] ] ] ] 5 => array:3 [ "identificador" => "bib0400" "etiqueta" => "6" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Femtosecond laser flap creation for laser in situ keratomileusis: Six-month follow-up of initial US clinical series" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:6 [ 0 => "L.T. Nordan" 1 => "S.G. Slade" 2 => "R.N. Baker" 3 => "C. Suarez" 4 => "T. Juhasz" 5 => "R. Kurtz" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "J Refract Surg." "fecha" => "2003" "volumen" => "19" "paginaInicial" => "8" "paginaFinal" => "14" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/12553599" "web" => "Medline" ] ] ] ] ] ] ] ] 6 => array:3 [ "identificador" => "bib0405" "etiqueta" => "7" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Surgical applications of femtosecond lasers" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:2 [ 0 => "S.H. Chung" 1 => "E. Mazur" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1002/jbio.200910053" "Revista" => array:6 [ "tituloSerie" => "J Biophotonics." "fecha" => "2009" "volumen" => "2" "paginaInicial" => "557" "paginaFinal" => "572" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/19606444" "web" => "Medline" ] ] ] ] ] ] ] ] 7 => array:3 [ "identificador" => "bib0410" "etiqueta" => "8" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "The role of femtolaser in cataract surgery" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:2 [ 0 => "Z.Z. Nagy" 1 => "J.P. Szaflik" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Klin Oczna." "fecha" => "2012" "volumen" => "114" "paginaInicial" => "324" "paginaFinal" => "327" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/23461165" "web" => "Medline" ] ] ] ] ] ] ] ] 8 => array:3 [ "identificador" => "bib0415" "etiqueta" => "9" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Initial clinical evaluation of an intraocular femtosecond laser in cataract surgery" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:4 [ 0 => "Z. Nagy" 1 => "A. Takacs" 2 => "T. Filkorn" 3 => "M. Sarayba" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.3928/1081597X-20091117-04" "Revista" => array:7 [ "tituloSerie" => "J Refract Surg." "fecha" => "2009" "volumen" => "25" "paginaInicial" => "1053" "paginaFinal" => "1060" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/20000286" "web" => "Medline" ] ] "itemHostRev" => array:3 [ "pii" => "S1470204502008161" "estado" => "S300" "issn" => "14702045" ] ] ] ] ] ] ] 9 => array:3 [ "identificador" => "bib0420" "etiqueta" => "10" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Efficacy and safety of femtosecond laser-assisted cataract surgery compared with manual cataract surgery: A meta-analysis of 14 567 eyes" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:4 [ 0 => "M. Popovic" 1 => "X. Campos-Möller" 2 => "M.B. Schlenker" 3 => "I.I. Ahmed" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.ophtha.2016.07.005" "Revista" => array:6 [ "tituloSerie" => "Ophthalmology." "fecha" => "2016" "volumen" => "123" "paginaInicial" => "2113" "paginaFinal" => "2126" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/27538796" "web" => "Medline" ] ] ] ] ] ] ] ] 10 => array:3 [ "identificador" => "bib0425" "etiqueta" => "11" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Femtosecond laser-assisted cataract surgery technology, outcome, future directions and modern applications" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:2 [ 0 => "J. Hooshmand" 1 => "B.J. Vote" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:5 [ "tituloSerie" => "Asia Pac J Ophthalmol (Phila)." "fecha" => "2017" "volumen" => "6" "paginaInicial" => "393" "paginaFinal" => "400" ] ] ] ] ] ] 11 => array:3 [ "identificador" => "bib0430" "etiqueta" => "12" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Surgical outcomes and safety of femtosecond laser cataract surgery: A prospective study of 1500 consecutive cases" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:5 [ 0 => "T.V. Roberts" 1 => "M. Lawless" 2 => "S.J. Bali" 3 => "C. Hodge" 4 => "G. Sutton" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.ophtha.2012.10.026" "Revista" => array:6 [ "tituloSerie" => "Ophthalmology." "fecha" => "2013" "volumen" => "120" "paginaInicial" => "227" "paginaFinal" => "233" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/23218822" "web" => "Medline" ] ] ] ] ] ] ] ] 12 => array:3 [ "identificador" => "bib0435" "etiqueta" => "13" "referencia" => array:1 [ 0 => array:1 [ "referenciaCompleta" => "Syed ZA, Moayedi J, Mohamedi M, Tashter J, Anthony T, Celiker C, et al. Cataract surgery outcomes at a UK independent sector treatment centre. Br J Ophthalmol. 2015;99:1460-5." ] ] ] 13 => array:3 [ "identificador" => "bib0440" "etiqueta" => "14" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "The Cataract National Dataset electronic multi-centre audit of 55 567 operations: Updating benchmark standards of care in the United Kingdom and internationally" "autores" => array:1 [ 0 => array:2 [ "etal" => true "autores" => array:6 [ 0 => "P. Jaycock" 1 => "R.L. Johnston" 2 => "H. Taylor" 3 => "M. Adams" 4 => "D.M. Tole" 5 => "P. Galloway" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1038/sj.eye. 6703015" "Revista" => array:7 [ "tituloSerie" => "Eye." "fecha" => "2009" "volumen" => "23" "paginaInicial" => "38" "paginaFinal" => "49" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/18034196" "web" => "Medline" ] ] "itemHostRev" => array:3 [ "pii" => "S0939475315300697" "estado" => "S300" "issn" => "09394753" ] ] ] ] ] ] ] 14 => array:3 [ "identificador" => "bib0445" "etiqueta" => "15" "referencia" => array:1 [ 0 => array:1 [ "referenciaCompleta" => "Manning S, Barry P, Henry Y, Rosen P, Stenevi U, Young D, et al. Femtosecond laser-assisted cataract surgery versus standard phacoemulsification cataract surgery: Study from the European Registry of Quality Outcomes for Cataract and Refractive Surgery. J Cataract Refract Surg. 2016;42:1779-90, <a target="_blank" href="https://doi.org/10.1016/j.jcrs.2016.10.013">https://doi.org/10.1016/j.jcrs.2016.10.013</a>." ] ] ] 15 => array:3 [ "identificador" => "bib0450" "etiqueta" => "16" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Posterior segment complications of laser in situ keratomileusis (LASIK)" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:2 [ 0 => "A. Mirshahi" 1 => "H. Baatz" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.survophthal.2009.04.008" "Revista" => array:6 [ "tituloSerie" => "Surv Ophthalmol." "fecha" => "2009" "volumen" => "54" "paginaInicial" => "433" "paginaFinal" => "440" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/19539831" "web" => "Medline" ] ] ] ] ] ] ] ] 16 => array:3 [ "identificador" => "bib0455" "etiqueta" => "17" "referencia" => array:1 [ 0 => array:1 [ "referenciaCompleta" => "Talamo JH, Gooding P, Angeley D, Culbertson WW, Schuele G, Andersen D, et al. Optical patient interface in femtosecond laser-assisted cataract surgery: Contact corneal applanation versus liquid immersion. J Cataract Refract Surg. 2013;39:501-10, <a target="_blank" href="https://doi.org/10.1016/j.jcrs.2013.01.021">https://doi.org/10.1016/j.jcrs.2013.01.021</a>." ] ] ] 17 => array:3 [ "identificador" => "bib0460" "etiqueta" => "18" "referencia" => array:1 [ 0 => array:1 [ "referenciaCompleta" => "Darian-Smith E, Howie AR, Abell RG, Kerr N, Allen PL, Vote BJ, et al. Intraocular pressure during femtosecond laser pretreatment: Comparison of glaucomatous eyes and nonglaucomatous eyes. J Cataract Refract Surg. 2015;41: 272-7." ] ] ] 18 => array:3 [ "identificador" => "bib0465" "etiqueta" => "19" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Light microscopy and scanning electron microscopy analysis of rigid curved interface femtosecond laser–assisted and manual anterior capsulotomy" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:5 [ 0 => "M. Ostovic" 1 => "O.K. Klaproth" 2 => "F.H. Hengerer" 3 => "W.J. Mayer" 4 => "T. Kohnen" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.jcrs.2013.07.024" "Revista" => array:6 [ "tituloSerie" => "J Cataract Refract Surg" "fecha" => "2013" "volumen" => "39" "paginaInicial" => "1587" "paginaFinal" => "1592" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/24075160" "web" => "Medline" ] ] ] ] ] ] ] ] 19 => array:3 [ "identificador" => "bib0470" "etiqueta" => "20" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Retinal detachment in myopic eyes after laser in situ keratomileusis" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "D.O. Mazur" 1 => "R. Hollifield" 2 => "W. Gee" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/s0002-9394(00)00469-4" "Revista" => array:6 [ "tituloSerie" => "Am J Ophthalmol." "fecha" => "2000" "volumen" => "129" "paginaInicial" => "823" "paginaFinal" => "824" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/10970239" "web" => "Medline" ] ] ] ] ] ] ] ] 20 => array:3 [ "identificador" => "bib0475" "etiqueta" => "21" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Laser-assisted cataract surgery: Soft lens assisted interface (SoftFit) versus direct contact interface" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:2 [ 0 => "B.S. Asena" 1 => "M. Kaskaloglu" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.5301/ejo.5000684" "Revista" => array:6 [ "tituloSerie" => "Eur J Ophthalmol." "fecha" => "2016" "volumen" => "26" "paginaInicial" => "242" "paginaFinal" => "247" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/26449258" "web" => "Medline" ] ] ] ] ] ] ] ] 21 => array:3 [ "identificador" => "bib0480" "etiqueta" => "22" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Femtosecond laser will not be a standard method for cataract extraction ten years from now" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:1 [ 0 => "B.H. Feldman" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.survophthal.2015.02.002" "Revista" => array:6 [ "tituloSerie" => "Surv Ophthalmol." "fecha" => "2015" "volumen" => "60" "paginaInicial" => "360" "paginaFinal" => "365" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/25824094" "web" => "Medline" ] ] ] ] ] ] ] ] 22 => array:3 [ "identificador" => "bib0485" "etiqueta" => "23" "referencia" => array:1 [ 0 => array:1 [ "referenciaCompleta" => "Zhang X, Yu Y, Zhang G, Zhou Y, Chen M, Wang Y, et al. Performance of femtosecond laser-assisted cataract surgery in Chinese patients with cataract: A prospective, multicenter, registry study. BMC Ophthalmol. 2019;19:77." ] ] ] 23 => array:3 [ "identificador" => "bib0490" "etiqueta" => "24" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Early experience with the femtosecond laser for cataract surgery" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:5 [ 0 => "S.J. Bali" 1 => "C. Hodge" 2 => "M. Lawless" 3 => "T.V. Roberts" 4 => "G. Sutton" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.ophtha.2011.12.025" "Revista" => array:6 [ "tituloSerie" => "Ophthalmology." "fecha" => "2012" "volumen" => "119" "paginaInicial" => "891" "paginaFinal" => "899" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/22361311" "web" => "Medline" ] ] ] ] ] ] ] ] 24 => array:3 [ "identificador" => "bib0495" "etiqueta" => "25" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Femtosecond laser-assisted cataract incisions: Architectural stability and reproducibility" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:4 [ 0 => "S. Masket" 1 => "M. Sarayba" 2 => "T. Ignacio" 3 => "N. Fram" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.jcrs.2010.03.027" "Revista" => array:6 [ "tituloSerie" => "J Cataract Refract Surg." "fecha" => "2010" "volumen" => "36" "paginaInicial" => "1048" "paginaFinal" => "1049" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/20494782" "web" => "Medline" ] ] ] ] ] ] ] ] 25 => array:3 [ "identificador" => "bib0500" "etiqueta" => "26" "referencia" => array:1 [ 0 => array:1 [ "referenciaCompleta" => "Alió J.L., Abdou A.A., Soria F., Javaloy J., Fernández-Buenaga F., Nagy Z.Z., et al. Femtosecond laser cataract Q18 incision morphology and corneal higher-order aberration analysis. J Refract Surg. 2013;29:590-5." ] ] ] 26 => array:3 [ "identificador" => "bib0505" "etiqueta" => "27" "referencia" => array:1 [ 0 => array:1 [ "referenciaCompleta" => "Mayer W.J., Klaproth O.K., Hengerer F.H., Kook D., Dirisamer M., Priglinger S., et al. In vitro Q19 immunohistochemical and morphological observations of penetrating corneal incisions created by a femtosecond laser used for assisted intraocular lens surgery. J Cataract Refract Surg. 2014;40:632-8." ] ] ] 27 => array:3 [ "identificador" => "bib0510" "etiqueta" => "28" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Corneal incision architecture: VICTUS femtosecond laser vs manual keratome" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:5 [ 0 => "R. Rodrigues" 1 => "M.S. Dos Santos" 2 => "R.E. Silver" 3 => "M. Campos" 4 => "R.L.R. Gomes" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.2147/OPTH.S181144" "Revista" => array:6 [ "tituloSerie" => "Clinical Ophthalmology." "fecha" => "2019" "volumen" => "13" "paginaInicial" => "147" "paginaFinal" => "152" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/30666085" "web" => "Medline" ] ] ] ] ] ] ] ] 28 => array:3 [ "identificador" => "bib0515" "etiqueta" => "29" "referencia" => array:1 [ 0 => array:1 [ "referenciaCompleta" => "Chaves M.A., de Medeiros A.L., Vilar C.M., Magalhães K.R., Gonçalves M., Tzelikis P.F., et al. Architecture evaluation of the main clear corneal incisions in femtosecond laser-assisted cataract surgery by optical coherence tomography imaging. Clin Ophthalmol. 2019;13:365-72." ] ] ] 29 => array:3 [ "identificador" => "bib0520" "etiqueta" => "30" "referencia" => array:1 [ 0 => array:1 [ "referenciaCompleta" => "Oshika T., Shimazaki J., Yoshitomi F., Oki K., Sakabe I., Matsuda S., et al. Arcuate keratotomy to treat corneal astigmatism after cataract surgery: A prospective evaluation of predictability and effectiveness. Ophthalmology. 1998;105:2012-6." ] ] ] 30 => array:3 [ "identificador" => "bib0525" "etiqueta" => "31" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Vector analysis of corneal astigmatism after combined femtosecond-assisted phacoemulsification and arcuate keratotomy" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:6 [ 0 => "T.C. Chan" 1 => "G.P. Cheng" 2 => "Z. Wang" 3 => "C.C. Tham" 4 => "V.C. Woo" 5 => "V. Jhanji" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.ajo.2015.05.004" "Revista" => array:6 [ "tituloSerie" => "Am J Ophthalmol." "fecha" => "2015" "volumen" => "160" "paginaInicial" => "250" "paginaFinal" => "255" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/25982969" "web" => "Medline" ] ] ] ] ] ] ] ] 31 => array:3 [ "identificador" => "bib0530" "etiqueta" => "32" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Nonpenetrating femtosecond laser intrastromal astigmatic keratotomy in eyes having cataract surgery" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "A.C. Day" 1 => "N.M. Lau" 2 => "J.D. Stevens" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.jcrs.2015.07.045" "Revista" => array:6 [ "tituloSerie" => "J Cataract Refract Surg." "fecha" => "2016" "volumen" => "42" "paginaInicial" => "102" "paginaFinal" => "109" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/26948784" "web" => "Medline" ] ] ] ] ] ] ] ] 32 => array:3 [ "identificador" => "bib0535" "etiqueta" => "33" "referencia" => array:1 [ 0 => array:1 [ "referenciaCompleta" => "Mastropasqua L., Toto L., Mattei P.A., Vecchiarino L., Mastropasqua A., Navarra R., et al. Optical coherence tomography and 3-dimensional confocal structured imaging system-guided femtosecond laser capsulotomy versus manual continuous curvilinear capsulorhexis. J Cataract Refract Surg. 2014;40:2035-43." ] ] ] 33 => array:3 [ "identificador" => "bib0540" "etiqueta" => "34" "referencia" => array:1 [ 0 => array:1 [ "referenciaCompleta" => "Mastropasqua L., Toto L., Calienno R., Mattei P.A., Mastropasqua A., Vecchiarino L., et al. Scanning electron microscopy evaluation of capsulorhexis in femtosecond laser-assisted cataract surgery. J Cataract Refract Surg. 2013;39:1581-6." ] ] ] 34 => array:3 [ "identificador" => "bib0545" "etiqueta" => "35" "referencia" => array:1 [ 0 => array:1 [ "referenciaCompleta" => "Reyes Lua M., Oertle P., Camenzind L., Goz A., Meyer C.H., Koniezcka K., et al. Superior rim stability of the lens capsule following manual over femtosecond laser capsulotomy. Invest Ophthalmol Vis Sci. 2016;57:2839-49." ] ] ] 35 => array:3 [ "identificador" => "bib0550" "etiqueta" => "36" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Comparison of anterior capsulotomy techniques: Continuous curvilinear capsulorhexis, femtosecond laser-assisted capsulotomy and selective laser capsulotomy" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:5 [ 0 => "S. Daya" 1 => "S.-P. Chee" 2 => "S.-E. Ti" 3 => "R. Packard" 4 => "D.H. Mordaunt" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:4 [ "tituloSerie" => "Br J Ophthalmol." "fecha" => "2019" "paginaInicial" => "2018" "paginaFinal" => "313421" ] ] ] ] ] ] 36 => array:3 [ "identificador" => "bib0555" "etiqueta" => "37" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Femtosecond laser–assisted cataract surgery versus standard phacoemulsification cataract surgery: Outcomes and safety in more than 4000 cases at a single center" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:6 [ 0 => "R.G. Abell" 1 => "E. Darian-Smith" 2 => "J.B. Kan" 3 => "P.L. Allen" 4 => "S.Y. Ewe" 5 => "B.J. Vote" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.jcrs.2014.06.025" "Revista" => array:6 [ "tituloSerie" => "J Cataract Refract Surg." "fecha" => "2015" "volumen" => "41" "paginaInicial" => "47" "paginaFinal" => "52" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/25466483" "web" => "Medline" ] ] ] ] ] ] ] ] 37 => array:3 [ "identificador" => "bib0560" "etiqueta" => "38" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Efficacy of anterior capsulotomy creation in femtosecond laser-assisted cataract surgery" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:5 [ 0 => "A.C. Day" 1 => "D.S. Gartry" 2 => "V. Maurino" 3 => "B.D. Allan" 4 => "J.D. Stevens" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.jcrs.2014.07.027" "Revista" => array:6 [ "tituloSerie" => "J Cataract Refract Surg." "fecha" => "2014" "volumen" => "40" "paginaInicial" => "2031" "paginaFinal" => "2034" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/25305149" "web" => "Medline" ] ] ] ] ] ] ] ] 38 => array:3 [ "identificador" => "bib0565" "etiqueta" => "39" "referencia" => array:1 [ 0 => array:1 [ "referenciaCompleta" => "Nagy Z.Z., Takacs A.I., Filkorn T., Kránitz K., Gyenes A., Juhász E., et al. Complications of femtosecond laser-assisted cataract surgery. J Cataract Refract Surg. 2014;40:20-8." ] ] ] 39 => array:3 [ "identificador" => "bib0570" "etiqueta" => "40" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Femtosecond laser-assisted capsulorhexis: Anterior capsule tags and tears" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:1 [ 0 => "R. Yeoh" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.jcrs.2015.02.023" "Revista" => array:6 [ "tituloSerie" => "J Cataract Refract Surg." "fecha" => "2015" "volumen" => "41" "paginaInicial" => "906" "paginaFinal" => "907" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/25840328" "web" => "Medline" ] ] ] ] ] ] ] ] 40 => array:3 [ "identificador" => "bib0575" "etiqueta" => "41" "referencia" => array:1 [ 0 => array:1 [ "referenciaCompleta" => "Oakley C.L., Vote B.J., Abell R.G., Darian-Smith E., Kan J.B., Ewe S., et al. Reply: To PMID 25466483. J Cataract Refract Surg. 2015;41:907-8." ] ] ] 41 => array:3 [ "identificador" => "bib0580" "etiqueta" => "42" "referencia" => array:1 [ 0 => array:1 [ "referenciaCompleta" => "Serrao S., Lombardo G., Desiderio G., Buratto L., Schiano-Lomoriello D., Pileri M., et al. Analysis of femtosecond laser assisted capsulotomy cutting edges and manual capsulorhexis using environmental scanning electron microscopy. J Ophthalmol. 2014;2014:520713." ] ] ] 42 => array:3 [ "identificador" => "bib0585" "etiqueta" => "43" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Anterior capsulotomy integrity after femtosecond laser-assisted cataract surgery" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:6 [ 0 => "R.G. Abell" 1 => "P.E. Davies" 2 => "D. Phelan" 3 => "K. Goemann" 4 => "Z.E. McPherson" 5 => "B.J. Vote" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.ophtha.2013.08.013" "Revista" => array:6 [ "tituloSerie" => "Ophthalmology." "fecha" => "2014" "volumen" => "121" "paginaInicial" => "17" "paginaFinal" => "24" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/24084498" "web" => "Medline" ] ] ] ] ] ] ] ] 43 => array:3 [ "identificador" => "bib0590" "etiqueta" => "44" "referencia" => array:1 [ 0 => array:1 [ "referenciaCompleta" => "Panthier C., Costantini F., Rigal-Sastourné J.C., Brézin A., Mehanna C., Guedj M., et al. Change of capsulotomy over 1 year in femtosecond laser-assisted cataract surgery and its impact on visual quality. J Refract Surg. 2017;33:44-9." ] ] ] 44 => array:3 [ "identificador" => "bib0595" "etiqueta" => "45" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Toward zero effective phacoemulsification time using femtosecond laser pretreatment" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "R.G. Abell" 1 => "N.M. Kerr" 2 => "B.J. Vote" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.ophtha.2012.11.045" "Revista" => array:6 [ "tituloSerie" => "Ophthalmology." "fecha" => "2013" "volumen" => "120" "paginaInicial" => "942" "paginaFinal" => "948" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/23465860" "web" => "Medline" ] ] ] ] ] ] ] ] 45 => array:3 [ "identificador" => "bib0600" "etiqueta" => "46" "referencia" => array:1 [ 0 => array:1 [ "referenciaCompleta" => "Yesilirmak N., Diakonis V.F., Batlle J.F., Sayed-Ahmed I.O., Davis Z., Waren D.P., et al. Comparison of phacoemulsification parameters between manual and femtosecond laser-assisted cataract surgery. Can J Ophthalmol. 2018;53:542-7." ] ] ] 46 => array:3 [ "identificador" => "bib0605" "etiqueta" => "47" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Corneal endothelial cell loss and corneal thickness in conventional compared with femtosecond laser-assisted cataract surgery: Three-month follow-up" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:5 [ 0 => "I. Conrad-Hengerer" 1 => "M. Al Juburi" 2 => "T. Schultz" 3 => "F.H. Hengerer" 4 => "H. Burkhard Dick" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.jcrs.2013.05.033u" "Revista" => array:6 [ "tituloSerie" => "J Cataract Refract Surg." "fecha" => "2013" "volumen" => "39" "paginaInicial" => "1307" "paginaFinal" => "1313" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/23871112" "web" => "Medline" ] ] ] ] ] ] ] ] 47 => array:3 [ "identificador" => "bib0610" "etiqueta" => "48" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Comparison of refractive predictability and endothelial cell loss in femtosecond laser-assisted cataract surgery and conventional phaco surgery: Prospective randomised trial with 6 months of follow-up" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:5 [ 0 => "T. Krarup" 1 => "R. Ejstrup" 2 => "A. Mortensen" 3 => "M. la Cour" 4 => "L.M. Holm" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1136/bmjophth-2018-000233" "Revista" => array:5 [ "tituloSerie" => "BMJ Open Ophthalmol." "fecha" => "2019" "volumen" => "4" "paginaInicial" => "e000233" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/30997403" "web" => "Medline" ] ] ] ] ] ] ] ] 48 => array:3 [ "identificador" => "bib0615" "etiqueta" => "49" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Comparing outcomes of phacoemulsification with femtosecond laser-assisted cataract surgery in patients with fuchs endothelial dystrophy" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:5 [ 0 => "W.W. Yong" 1 => "H.-C. Chai" 2 => "L. Shen" 3 => "R. Manotosh" 4 => "W.T.A. Tan" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.ajo.2018.08.006" "Revista" => array:6 [ "tituloSerie" => "Am J Ophthalmol." "fecha" => "2018" "volumen" => "196" "paginaInicial" => "173" "paginaFinal" => "180" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/30098347" "web" => "Medline" ] ] ] ] ] ] ] ] 49 => array:3 [ "identificador" => "bib0620" "etiqueta" => "50" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Continuous intracameral phenylephrine–ketorolac irrigation for miosis prevention in femtosecond laser–assisted cataract surgery: Reduction in surgical time and iris manipulation" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "K. Walter" 1 => "N. Delwadia" 2 => "J. Coben" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.jcrs.2018.11.004" "Revista" => array:6 [ "tituloSerie" => "J Cataract Refract Surg." "fecha" => "2019" "volumen" => "45" "paginaInicial" => "465" "paginaFinal" => "469" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/30661968" "web" => "Medline" ] ] ] ] ] ] ] ] 50 => array:3 [ "identificador" => "bib0625" "etiqueta" => "51" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Changes in prostaglandin levels in patients undergoing femtosecond laser-assisted cataract surgery" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:4 [ 0 => "T. Schultz" 1 => "S.C. Joachim" 2 => "M. Kuehn" 3 => "H.B. Dick" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.3928/1081597X-20131021-03" "Revista" => array:6 [ "tituloSerie" => "J Refract Surg." "fecha" => "2013" "volumen" => "29" "paginaInicial" => "742" "paginaFinal" => "747" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/24203805" "web" => "Medline" ] ] ] ] ] ] ] ] 51 => array:3 [ "identificador" => "bib0630" "etiqueta" => "52" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Prostaglandin release during femtosecond laser-assisted cataract surgery: Main inducer" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:4 [ 0 => "T. Schultz" 1 => "S.C. Joachim" 2 => "M. Stellbogen" 3 => "H.B. Dick" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.3928/1081597X-20150122-01" "Revista" => array:6 [ "tituloSerie" => "J Refract Surg." "fecha" => "2015" "volumen" => "31" "paginaInicial" => "78" "paginaFinal" => "81" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/25735039" "web" => "Medline" ] ] ] ] ] ] ] ] 52 => array:3 [ "identificador" => "bib0635" "etiqueta" => "53" "referencia" => array:1 [ 0 => array:1 [ "referenciaCompleta" => "Anisimova N.S., Arbisser L.B., Petrovski G., Petrichuk S.V., Sobolev N.P., Petrovski B., et al. Effect of NSAIDs on pupil diameter and expression of aqueous humor cytokines in FLACS versus conventional phacoemulsification. J Refract Surg. 2018;34:646-52." ] ] ] 53 => array:3 [ "identificador" => "bib0640" "etiqueta" => "54" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Pupil-size alterations induced by photodisruption during femtosecond laser-assisted cataract surgery" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:4 [ 0 => "J.H. Jun" 1 => "K.Y. Hwang" 2 => "S.D. Chang" 3 => "C.K. Joo" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.jcrs.2014.10.027" "Revista" => array:6 [ "tituloSerie" => "J Cataract Refract Surg" "fecha" => "2015" "volumen" => "41" "paginaInicial" => "278" "paginaFinal" => "285" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/25661121" "web" => "Medline" ] ] ] ] ] ] ] ] 54 => array:3 [ "identificador" => "bib0645" "etiqueta" => "55" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Factors influencing pupil behaviour during femtosecond laser assisted cataract surgery" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:6 [ 0 => "M.Z. Popiela" 1 => "T. Young-Zvandasara" 2 => "P. Nidamanuri" 3 => "T. Moore" 4 => "A. Leccisotti" 5 => "V. Kumar" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.clae.2018.10.010" "Revista" => array:6 [ "tituloSerie" => "Cont Lens Anterior Eye." "fecha" => "2019" "volumen" => "42" "paginaInicial" => "295" "paginaFinal" => "298" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/30448179" "web" => "Medline" ] ] ] ] ] ] ] ] 55 => array:3 [ "identificador" => "bib0650" "etiqueta" => "56" "referencia" => array:1 [ 0 => array:1 [ "referenciaCompleta" => "Kiss HJ, Takacs AI, Kranitz K, Sandor GL, Toth G, Gilanyi B, et al. One-day use of preoperative topical nonsteroidal anti-inflammatory drug prevents intraoperative prostaglandin level elevation during femtosecond laser-assisted cataract surgery. Curr Eye Res. 2016;41:1064-7." ] ] ] 56 => array:3 [ "identificador" => "bib0655" "etiqueta" => "57" "referencia" => array:1 [ 0 => array:1 [ "referenciaCompleta" => "Greenberg PB, Tseng VL, Wu W-C, Liu J, Jiang L, Chen CK, et al. Prevalence and predictors of ocular complications associated with cataract surgery in United States veterans. Ophthalmology. 2011;118:507-14." ] ] ] 57 => array:3 [ "identificador" => "bib0660" "etiqueta" => "58" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "The role of steroids and NSAIDs in prevention and treatment of postsurgical cystoid macular edema" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:2 [ 0 => "A. Grzybowski" 1 => "P. Kanclerz" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.2174/1381612825666190206104524" "Revista" => array:6 [ "tituloSerie" => "Curr Pharm Des." "fecha" => "2018" "volumen" => "24" "paginaInicial" => "4896" "paginaFinal" => "4902" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/30727876" "web" => "Medline" ] ] ] ] ] ] ] ] 58 => array:3 [ "identificador" => "bib0665" "etiqueta" => "59" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Pseudophakic cystoid macular edema: Update 2016" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:4 [ 0 => "A. Grzybowski" 1 => "B.L. Sikorski" 2 => "F.J. Ascaso" 3 => "V. Huerva" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.2147/CIA.S111761" "Revista" => array:6 [ "tituloSerie" => "Clin Interv Aging." "fecha" => "2016" "volumen" => "11" "paginaInicial" => "1221" "paginaFinal" => "1229" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/27672316" "web" => "Medline" ] ] ] ] ] ] ] ] 59 => array:3 [ "identificador" => "bib0670" "etiqueta" => "60" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Cystoid macular edema after femtosecond laser-assisted versus phacoemulsification cataract surgery" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:5 [ 0 => "S.Y.P. Ewe" 1 => "C.L. Oakley" 2 => "R.G. Abell" 3 => "P.L. Allen" 4 => "B.J. Vote" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.jcrs.2015.04.031" "Revista" => array:6 [ "tituloSerie" => "J Cataract Refract Surg." "fecha" => "2015" "volumen" => "41" "paginaInicial" => "2373" "paginaFinal" => "2378" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/26703485" "web" => "Medline" ] ] ] ] ] ] ] ] 60 => array:3 [ "identificador" => "bib0675" "etiqueta" => "61" "referencia" => array:1 [ 0 => array:1 [ "referenciaCompleta" => "Ewe SYP, Abell RG, Oakley CL, Lim CHL, Allen PL, McPherson ZE, et al. A comparative cohort study of visual outcomes in femtosecond laser-assisted versus phacoemulsification cataract surgery. Ophthalmology." ] ] ] 61 => array:3 [ "identificador" => "bib0680" "etiqueta" => "62" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Femtosecond laser-induced macular changes and anterior segment inflammation in cataract surgery" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:5 [ 0 => "I. Conrad-Hengerer" 1 => "F.H. Hengerer" 2 => "M. Al Juburi" 3 => "T. Schultz" 4 => "H.B. Dick" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.3928/1081597X-20140321-01" "Revista" => array:6 [ "tituloSerie" => "J Refract Surg." "fecha" => "2014" "volumen" => "30" "paginaInicial" => "222" "paginaFinal" => "226" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/24702572" "web" => "Medline" ] ] ] ] ] ] ] ] 62 => array:3 [ "identificador" => "bib0685" "etiqueta" => "63" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Incidence of cystoid macular edema: Femtosecond laser-assisted cataract surgery versus manual cataract surgery" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:4 [ 0 => "L. Levitz" 1 => "J. Reich" 2 => "T.V. Roberts" 3 => "M. Lawless" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.jcrs.2014.11.039" "Revista" => array:6 [ "tituloSerie" => "J Cataract Refract Surg." "fecha" => "2015" "volumen" => "41" "paginaInicial" => "683" "paginaFinal" => "686" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/25724279" "web" => "Medline" ] ] ] ] ] ] ] ] 63 => array:3 [ "identificador" => "bib0690" "etiqueta" => "64" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Laser-assisted cataract surgery versus standard ultrasound phacoemulsification cataract surgery" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:4 [ 0 => "A.C. Day" 1 => "D.M. Gore" 2 => "C. Bunce" 3 => "J.R. Evans" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:2 [ "tituloSerie" => "Cochrane Database Syst Rev" "fecha" => "2016" ] ] ] ] ] ] 64 => array:3 [ "identificador" => "bib0695" "etiqueta" => "65" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "High rate of early posterior capsule opacification following femtosecond laser-assisted cataract surgery" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:5 [ 0 => "B. Rostami" 1 => "J. Tian" 2 => "N. Jackson" 3 => "R. Karanjia" 4 => "K. Lu" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1159/000449124" "Revista" => array:6 [ "tituloSerie" => "Case Rep Ophthalmol." "fecha" => "2016" "volumen" => "7" "paginaInicial" => "213" "paginaFinal" => "217" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/28101040" "web" => "Medline" ] ] ] ] ] ] ] ] 65 => array:3 [ "identificador" => "bib0700" "etiqueta" => "66" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Comparative evaluation of femtosecond laser–assisted cataract surgery and conventional phacoemulsification in eyes with a shallow anterior chamber" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:5 [ 0 => "V.A. Vasavada" 1 => "S. Vasavada" 2 => "A.R. Vasavada" 3 => "V. Vasavada" 4 => "S. Srivastava" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.jcrs.2018.11.037" "Revista" => array:6 [ "tituloSerie" => "J Cataract Refract Surg." "fecha" => "2019" "volumen" => "45" "paginaInicial" => "547" "paginaFinal" => "552" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/31030773" "web" => "Medline" ] ] ] ] ] ] ] ] 66 => array:3 [ "identificador" => "bib0705" "etiqueta" => "67" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Comparing the curative effects between femtosecond laser-assisted cataract surgery and conventional phacoemulsification surgery: A meta-analysis" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:4 [ 0 => "X. Chen" 1 => "K. Chen" 2 => "J. He" 3 => "K. Yao" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1371/journal.pone.0152088" "Revista" => array:5 [ "tituloSerie" => "PLoS One." "fecha" => "2016" "volumen" => "11" "paginaInicial" => "e0152088" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/26999612" "web" => "Medline" ] ] ] ] ] ] ] ] 67 => array:3 [ "identificador" => "bib0710" "etiqueta" => "68" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Visual and refractive outcomes in manual versus femtosecond laser-assisted cataract surgery: A single-center retrospective cohort analysis of 1838 eyes" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:5 [ 0 => "T.A. Berk" 1 => "M.B. Schlenker" 2 => "X. Campos-Möller" 3 => "A.M. Pereira" 4 => "I.I. Ahmed" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.ophtha.2018.01.028" "Revista" => array:6 [ "tituloSerie" => "Ophthalmology." "fecha" => "2018" "volumen" => "125" "paginaInicial" => "1172" "paginaFinal" => "1180" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/29523441" "web" => "Medline" ] ] ] ] ] ] ] ] 68 => array:3 [ "identificador" => "bib0715" "etiqueta" => "69" "referencia" => array:1 [ 0 => array:1 [ "referenciaCompleta" => "Economic evaluation of femtosecond laser assisted cataract surgery [Tabular View] [consultado 22 Jul 2019]. Disponible en: ClinicalTrials.gov. https://clinicaltrials.gov/ct2/show/record/NCT01982006." ] ] ] 69 => array:3 [ "identificador" => "bib0720" "etiqueta" => "70" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Financial modelling of femtosecond laser-assisted cataract surgery within the National Health Service using a «hub and spoke» model for the delivery of high-volume cataract surgery" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "H.W. Roberts" 1 => "M.Z. Ni" 2 => "D.P. O’Brart" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:4 [ "tituloSerie" => "BMJ Open." "fecha" => "2017" "volumen" => "7" "paginaInicial" => "e160136" ] ] ] ] ] ] 70 => array:3 [ "identificador" => "bib0725" "etiqueta" => "71" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Operating times of experienced cataract surgeons beginning femtosecond laser–assisted cataract surgery" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:4 [ 0 => "J.G. Lubahn" 1 => "K.E. Donaldson" 2 => "W.W. Culbertson" 3 => "S.H. Yoo" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.jcrs. 03.024 2014" "Revista" => array:6 [ "tituloSerie" => "J Cataract Refract Surg." "fecha" => "2014" "volumen" => "40" "paginaInicial" => "1773" "paginaFinal" => "1776" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/25217069" "web" => "Medline" ] ] ] ] ] ] ] ] 71 => array:3 [ "identificador" => "bib0730" "etiqueta" => "72" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Initial evaluation of a femtosecond laser system in cataract surgery" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:6 [ 0 => "J.S. Chang" 1 => "I.N. Chen" 2 => "W.-M. Chan" 3 => "J.C. Ng" 4 => "V.K. Chan" 5 => "A.K. Law" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.jcrs.2013.08.045" "Revista" => array:6 [ "tituloSerie" => "J Cataract Refract Surg." "fecha" => "2014" "volumen" => "40" "paginaInicial" => "29" "paginaFinal" => "36" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/24269139" "web" => "Medline" ] ] ] ] ] ] ] ] 72 => array:3 [ "identificador" => "bib0735" "etiqueta" => "73" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Femtosecond laser-assisted versus phacoemulsification for cataract extraction and intraocular lens implantation: Clinical outcomes review" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "S.Y. Ewe" 1 => "R.G. Abell" 2 => "B.J. Vote" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1097/ICU.0000000000000433" "Revista" => array:6 [ "tituloSerie" => "Curr Opin Ophthalmol." "fecha" => "2018" "volumen" => "29" "paginaInicial" => "54" "paginaFinal" => "60" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/28914688" "web" => "Medline" ] ] ] ] ] ] ] ] 73 => array:3 [ "identificador" => "bib0740" "etiqueta" => "74" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Cost-effectiveness of femtosecond laser-assisted cataract surgery versus phacoemulsification cataract surgery" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:2 [ 0 => "R.G. Abell" 1 => "B.J. Vote" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.ophtha.2013.07.056" "Revista" => array:6 [ "tituloSerie" => "Ophthalmology." "fecha" => "2014" "volumen" => "121" "paginaInicial" => "10" "paginaFinal" => "16" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/24120324" "web" => "Medline" ] ] ] ] ] ] ] ] ] ] ] ] ] "idiomaDefecto" => "es" "url" => "/03656691/0000009500000011/v2_202108180554/S0365669120302203/v2_202108180554/es/main.assets" "Apartado" => array:4 [ "identificador" => "7283" "tipo" => "SECCION" "es" => array:2 [ "titulo" => "Artículos originales" "idiomaDefecto" => true ] "idiomaDefecto" => "es" ] "PDF" => "https://static.elsevier.es/multimedia/03656691/0000009500000011/v2_202108180554/S0365669120302203/v2_202108180554/es/main.pdf?idApp=UINPBA00004N&text.app=https://www.elsevier.es/" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0365669120302203?idApp=UINPBA00004N" ]
año/Mes | Html | Total | |
---|---|---|---|
2024 Abril | 1 | 0 | 1 |
2023 Marzo | 3 | 0 | 3 |
2021 Mayo | 1 | 0 | 1 |
2021 Abril | 1 | 0 | 1 |
2021 Enero | 1 | 0 | 1 |
2020 Diciembre | 17 | 6 | 23 |
2020 Noviembre | 14 | 4 | 18 |
2020 Agosto | 0 | 2 | 2 |