covid
Buscar en
Colombian Journal of Anesthesiology
Toda la web
Inicio Colombian Journal of Anesthesiology Letter to the Editor
Información de la revista
Vol. 45. Núm. 1.
Páginas 80 (enero - marzo 2017)
Vol. 45. Núm. 1.
Páginas 80 (enero - marzo 2017)
Letter to the Editor
Open Access
Letter to the Editor
Carta al Editor
Visitas
1541
Oscar L. Mosquera-Dussána, Daniel Botero-Rosasb,
Autor para correspondencia
danybotero@hotmail.com

Corresponding author at: School of Medicine, La Sabana University, Chía-Cundinamarca, Colombia.
, Henry Oliverosb
a Doctorado en Biociencias, Universidad de La Sabana, Chía-Cundinamarca, Colombia
b School of Medicine, Universidad de La Sabana, Chía-Cundinamarca, Colombia
Este artículo ha recibido

Under a Creative Commons license
Información del artículo
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Texto completo

We are pleased to receive Dr. Eric B. Rosero's1 editorial comments regarding the trial: “Randomized cross-over clinical trial comparing two pharmacokinetic models of propofol using entropy indexes”.2

One of the drawbacks of monitoring depth of anesthesia is that the records are usually contaminated with physiological and external artifacts; the reconstruction of a biological signal that accurately represents the relevant biological information is not an easy task. However, the Entropy module3 includes a pre-processing step that minimizes the introduction of noise into the signals recorded.

There are challenges inherent to the design of crossover trials but it is unlikely that the period effect occurred because the length of time of the surgical procedure was limited to maximum two hours. Given the type of procedure, during that time there were no volume exchanges or relevant changes in the physiological variables such as temperature and other hemodynamic conditions. It should be kept in mind that in terms of the carry-over effect, the washout period shall be enough to prevent the drug from having any pharmacodynamic effects and from interfering with the second treatment period.

With regards to the possibility of experiencing intraoperative recall upon the discontinuation of the propofol infusion (constant remifentanil infusion), no intraoperative awareness was reported during the patients’ follow-up.

Funding comment

The authors did not receive any sponsorship to produce this article.

Conflicts of interest

The authors have no conflicts of interest to declare.

References
[1]
E.B. Rosero.
La caracterización de la profundidad de la anestesia durante las infusiones controladas a objetivo: no es un trabajo fácil.
Rev Colomb Anestesiol, 4 (2016), pp. 187-189
[2]
O. Mosquera-Dussán, A. Cárdenas, D. Botero-Rosas, A. Yepes, H. Oliveros, R. Henao, et al.
Ensayo clínico cruzado y aleatorizado para comparar 2 modelos farmacocinéticos de propofol usando índices de entropía.
Rev Colomb Anestesiol, 44 (2016), pp. 194-202
[3]
H. Viertiö-Oja, V. Maja, M. Särkelä, P. Talja, N. Tenkanen, H. Tolvanen-Laakso, et al.
Description of the Entropy™ algorithm as applied in the Datex-Ohmeda S/5TM Entropy Module.
Acta Anaesthesiol Scand, 48 (2004), pp. 154-161

Please cite this article as: Mosquera-Dussán OL, Botero-Rosas D, Oliveros H. Carta al Editor. Rev Colomb Anestesiol. 2017;45:80.

Copyright © 2016. Sociedad Colombiana de Anestesiología y Reanimación
Descargar PDF
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos