Artículo
Comprando el artículo el PDF del mismo podrá ser descargado
Precio 19,34 €
Comprar ahora
array:24 [ "pii" => "S002577531300537X" "issn" => "00257753" "doi" => "10.1016/j.medcli.2013.07.011" "estado" => "S300" "fechaPublicacion" => "2014-01-21" "aid" => "2686" "copyright" => "Elsevier España, S.L.. Todos los derechos reservados" "copyrightAnyo" => "2013" "documento" => "article" "crossmark" => 0 "subdocumento" => "sco" "cita" => "Med Clin. 2014;142:67-9" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:2 [ "total" => 501 "formatos" => array:3 [ "EPUB" => 7 "HTML" => 362 "PDF" => 132 ] ] "itemSiguiente" => array:18 [ "pii" => "S0025775313005344" "issn" => "00257753" "doi" => "10.1016/j.medcli.2013.02.042" "estado" => "S300" "fechaPublicacion" => "2014-01-21" "aid" => "2683" "copyright" => "Elsevier España, S.L." "documento" => "article" "crossmark" => 0 "subdocumento" => "crp" "cita" => "Med Clin. 2014;142:70-2" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:2 [ "total" => 873 "formatos" => array:3 [ "EPUB" => 9 "HTML" => 676 "PDF" => 188 ] ] "es" => array:13 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Nota clínica</span>" "titulo" => "Neumonía por <span class="elsevierStyleItalic">Legionella pneumophila</span> asociada al uso de un humidificador doméstico en una niña inmunocompetente" "tienePdf" => "es" "tieneTextoCompleto" => "es" "tieneResumen" => array:2 [ 0 => "es" 1 => "en" ] "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "70" "paginaFinal" => "72" ] ] "titulosAlternativos" => array:1 [ "en" => array:1 [ "titulo" => "<span class="elsevierStyleItalic">Legionella pneumophila</span> pneumonia associated with the use of a home humidifier in an immunocompetent girl" ] ] "contieneResumen" => array:2 [ "es" => true "en" => true ] "contieneTextoCompleto" => array:1 [ "es" => true ] "contienePdf" => array:1 [ "es" => true ] "resumenGrafico" => array:2 [ "original" => 0 "multimedia" => array:7 [ "identificador" => "fig0005" "etiqueta" => "Figura 1" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr1.jpeg" "Alto" => 969 "Ancho" => 1300 "Tamanyo" => 194727 ] ] "descripcion" => array:1 [ "es" => "<p id="spar0035" class="elsevierStyleSimplePara elsevierViewall">Imágenes del humidificador por ultrasonidos. Se observa la presencia de materia orgánica y humedad en la que pueden proliferar los microorganismos. a) Humidificador. b) Depósito de agua y cámara de vaporización. c) Transductor. d) Detalle del estado de mantenimiento del depósito.</p>" ] ] ] "autores" => array:1 [ 0 => array:2 [ "autoresLista" => "Bertha Angélica Bonilla Escobar, Juan Carlos Montero Rubio, Guadalupe Martínez Juárez" "autores" => array:3 [ 0 => array:2 [ "nombre" => "Bertha Angélica" "apellidos" => "Bonilla Escobar" ] 1 => array:2 [ "nombre" => "Juan Carlos" "apellidos" => "Montero Rubio" ] 2 => array:2 [ "nombre" => "Guadalupe" "apellidos" => "Martínez Juárez" ] ] ] ] ] "idiomaDefecto" => "es" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0025775313005344?idApp=UINPBA00004N" "url" => "/00257753/0000014200000002/v1_201401110110/S0025775313005344/v1_201401110110/es/main.assets" ] "itemAnterior" => array:18 [ "pii" => "S002577531300643X" "issn" => "00257753" "doi" => "10.1016/j.medcli.2013.09.011" "estado" => "S300" "fechaPublicacion" => "2014-01-21" "aid" => "2726" "copyright" => "Elsevier España, S.L." "documento" => "article" "crossmark" => 0 "subdocumento" => "sco" "cita" => "Med Clin. 2014;142:64-6" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:2 [ "total" => 690 "formatos" => array:3 [ "EPUB" => 8 "HTML" => 547 "PDF" => 135 ] ] "es" => array:10 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Editorial</span>" "titulo" => "¿Es posible reducir la inflamación crónica en la infección por el virus de la inmunodeficiencia humana?" "tienePdf" => "es" "tieneTextoCompleto" => "es" "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "64" "paginaFinal" => "66" ] ] "titulosAlternativos" => array:1 [ "en" => array:1 [ "titulo" => "Is it posible to reduce the human immunodeficiency virus-associated chronic inflammation?" ] ] "contieneTextoCompleto" => array:1 [ "es" => true ] "contienePdf" => array:1 [ "es" => true ] "autores" => array:1 [ 0 => array:2 [ "autoresLista" => "Muntsa Rocafort, Roger Paredes" "autores" => array:2 [ 0 => array:2 [ "nombre" => "Muntsa" "apellidos" => "Rocafort" ] 1 => array:2 [ "nombre" => "Roger" "apellidos" => "Paredes" ] ] ] ] ] "idiomaDefecto" => "es" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S002577531300643X?idApp=UINPBA00004N" "url" => "/00257753/0000014200000002/v1_201401110110/S002577531300643X/v1_201401110110/es/main.assets" ] "asociados" => array:1 [ 0 => array:18 [ "pii" => "S0025775313005344" "issn" => "00257753" "doi" => "10.1016/j.medcli.2013.02.042" "estado" => "S300" "fechaPublicacion" => "2014-01-21" "aid" => "2683" "copyright" => "Elsevier España, S.L." "documento" => "article" "crossmark" => 0 "subdocumento" => "crp" "cita" => "Med Clin. 2014;142:70-2" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:2 [ "total" => 873 "formatos" => array:3 [ "EPUB" => 9 "HTML" => 676 "PDF" => 188 ] ] "es" => array:13 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Nota clínica</span>" "titulo" => "Neumonía por <span class="elsevierStyleItalic">Legionella pneumophila</span> asociada al uso de un humidificador doméstico en una niña inmunocompetente" "tienePdf" => "es" "tieneTextoCompleto" => "es" "tieneResumen" => array:2 [ 0 => "es" 1 => "en" ] "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "70" "paginaFinal" => "72" ] ] "titulosAlternativos" => array:1 [ "en" => array:1 [ "titulo" => "<span class="elsevierStyleItalic">Legionella pneumophila</span> pneumonia associated with the use of a home humidifier in an immunocompetent girl" ] ] "contieneResumen" => array:2 [ "es" => true "en" => true ] "contieneTextoCompleto" => array:1 [ "es" => true ] "contienePdf" => array:1 [ "es" => true ] "resumenGrafico" => array:2 [ "original" => 0 "multimedia" => array:7 [ "identificador" => "fig0005" "etiqueta" => "Figura 1" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr1.jpeg" "Alto" => 969 "Ancho" => 1300 "Tamanyo" => 194727 ] ] "descripcion" => array:1 [ "es" => "<p id="spar0035" class="elsevierStyleSimplePara elsevierViewall">Imágenes del humidificador por ultrasonidos. Se observa la presencia de materia orgánica y humedad en la que pueden proliferar los microorganismos. a) Humidificador. b) Depósito de agua y cámara de vaporización. c) Transductor. d) Detalle del estado de mantenimiento del depósito.</p>" ] ] ] "autores" => array:1 [ 0 => array:2 [ "autoresLista" => "Bertha Angélica Bonilla Escobar, Juan Carlos Montero Rubio, Guadalupe Martínez Juárez" "autores" => array:3 [ 0 => array:2 [ "nombre" => "Bertha Angélica" "apellidos" => "Bonilla Escobar" ] 1 => array:2 [ "nombre" => "Juan Carlos" "apellidos" => "Montero Rubio" ] 2 => array:2 [ "nombre" => "Guadalupe" "apellidos" => "Martínez Juárez" ] ] ] ] ] "idiomaDefecto" => "es" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0025775313005344?idApp=UINPBA00004N" "url" => "/00257753/0000014200000002/v1_201401110110/S0025775313005344/v1_201401110110/es/main.assets" ] ] "es" => array:11 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Editorial</span>" "titulo" => "Legionelosis en el niño y nuevas fuentes de transmisión" "tieneTextoCompleto" => true "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "67" "paginaFinal" => "69" ] ] "autores" => array:1 [ 0 => array:3 [ "autoresLista" => "Miquel Sabrià" "autores" => array:1 [ 0 => array:3 [ "nombre" => "Miquel" "apellidos" => "Sabrià" "email" => array:1 [ 0 => "msabria.germanstrias@gencat.cat" ] ] ] "afiliaciones" => array:1 [ 0 => array:2 [ "entidad" => "Hospital Universitario Germans Trias i Pujol, Universitat Autònoma de Barcelona, Barcelona, España" "identificador" => "aff0005" ] ] ] ] "titulosAlternativos" => array:1 [ "en" => array:1 [ "titulo" => "Legionellosis in children and new transmission sources" ] ] "textoCompleto" => "<span class="elsevierStyleSections"><p id="par0005" class="elsevierStylePara elsevierViewall">El término legionelosis hace referencia a 2 síndromes clínicos causados por la bacteria <span class="elsevierStyleItalic">Legionella</span>: el síndrome de Pontiac, cuadro febril autolimitado atribuido serológicamente a distintas especies de <span class="elsevierStyleItalic">Legionella</span>, y la enfermedad del legionario, neumonía causada por <span class="elsevierStyleItalic">Legionella</span>, entidad reconocida por primera vez en el año 1976, en el contexto de un brote acaecido en un hotel de Filadelfia<a class="elsevierStyleCrossRef" href="#bib0005"><span class="elsevierStyleSup">1</span></a>.</p><p id="par0010" class="elsevierStylePara elsevierViewall">La familia <span class="elsevierStyleItalic">Legionellaceae</span> comprende más de 50 especies y más de 70 serogrupos, siendo <span class="elsevierStyleItalic">Legionella pneumophila</span> serogrupo 1 (<span class="elsevierStyleItalic">L. pneumophila</span> sg 1) la responsable de la mayoría de las infecciones en humanos. El hábitat natural de <span class="elsevierStyleItalic">Legionella</span> es el agua, habiendo sido aislada de distintos hábitos acuáticos, desde lagos a circuitos de grandes edificios e instalaciones industriales. En los últimos años se ha aislado también de abonos agrícolas y, ocasionalmente, se han descrito casos de infección respiratoria relacionados con la fabricación o uso de los mismos<a class="elsevierStyleCrossRefs" href="#bib0010"><span class="elsevierStyleSup">2,3</span></a>.</p><p id="par0015" class="elsevierStylePara elsevierViewall"><span class="elsevierStyleItalic">Legionella</span> sobrevive bajo condiciones ambientales muy diversas, integrada en el <span class="elsevierStyleItalic">biofilm</span> de muchos continentes acuáticos y muy especialmente en el interior de las amebas, donde se multiplica en sus fagosomas y queda resguardada de agresiones externas<a class="elsevierStyleCrossRef" href="#bib0020"><span class="elsevierStyleSup">4</span></a>. Las formas quísticas de las amebas pueden resistir temperaturas y concentraciones de cloro muy altas, lo que justifica la enorme dificultad de erradicar <span class="elsevierStyleItalic">Legionella</span> de muchos continentes acuáticos artificiales<a class="elsevierStyleCrossRef" href="#bib0025"><span class="elsevierStyleSup">5</span></a>.</p><p id="par0020" class="elsevierStylePara elsevierViewall"><span class="elsevierStyleItalic">Legionella</span> es una causa frecuente de neumonía comunitaria en los adultos<a class="elsevierStyleCrossRefs" href="#bib0030"><span class="elsevierStyleSup">6,7</span></a>, habiéndose implicado también en muchos casos de neumonía nosocomial. Desde la segunda mitad de la década de 1990 se ha producido un aumento progresivo de los casos de legionelosis tanto en la comunidad como en los centros sanitarios, en relación con el uso del test para la detección del antígeno soluble de <span class="elsevierStyleItalic">Legionella</span> en orina, y con la mayor concienciación del entorno sanitario respecto a esta problemática. Actualmente más del 90% de los casos de legionelosis se diagnostican a través de esta prueba, que fundamentalmente detecta <span class="elsevierStyleItalic">L. pneumophila</span> sg 1, y muy pocos a través del cultivo en medio seleccionado. De ahí que conozcamos bastante bien la historia natural de la infección por <span class="elsevierStyleItalic">L. pneumophila</span> sg 1, pero mucho menos la relacionada con otras especies y serogrupos. Igual que ocurrió con la introducción del test urinario en la década de 1990, es probable que la aparición de nuevas técnicas que permitan ampliar el diagnóstico a otras especies y serogrupos modifique muchos de los conceptos actuales sobre la legionelosis.</p><p id="par0025" class="elsevierStylePara elsevierViewall">Se dice que la neumonía comunitaria por <span class="elsevierStyleItalic">Legionella</span> incide fundamentalmente en la población añosa y con enfermedades crónicas subyacentes. Sin embargo, este tópico debe interpretarse con precaución. La mayoría de las neumonías bacterianas inciden en este grupo poblacional por motivos evidentes que escapan al objetivo de este editorial. Sin embargo, cuando se analizan detenidamente las series más actuales de legionelosis, en las que se incluyen pacientes menos graves, muchos de ellos diagnosticados mediante antigenuria, se observa que esta infección suele presentarse también en individuos jóvenes y sin enfermedad de base (aun cuando en la mayoría de los casos suele estar presente el hábito tabáquico)<a class="elsevierStyleCrossRefs" href="#bib0040"><span class="elsevierStyleSup">8,9</span></a>.</p><p id="par0030" class="elsevierStylePara elsevierViewall">Aun así, la neumonía por <span class="elsevierStyleItalic">Legionella</span> suele ser infrecuente en niños. En una extensa revisión de la literatura médica llegaron a identificarse 76 casos de legionelosis publicados, 26 en menores de 12 meses y 13 en neonatos. La adquisición de la enfermedad fue comunitaria en el 46% de los casos y nosocomial en el resto. En la mayoría existían comorbilidades y la mortalidad alcanzó el 33%. En todos los casos el origen de la infección provino del agua<a class="elsevierStyleCrossRef" href="#bib0050"><span class="elsevierStyleSup">10</span></a>.</p><p id="par0035" class="elsevierStylePara elsevierViewall">Algunos autores señalan que la legionelosis infantil puede ser una enfermedad infradiagnosticada. Y puede ser cierto si tenemos en cuenta que en pocas ocasiones se piensa en <span class="elsevierStyleItalic">Legionella</span> ante un niño con neumonía. Sin embargo, el hecho de que en los grandes brotes la incidencia de legionelosis en este grupo poblacional sea baja o nula es un dato que va muy en contra. En el contexto de un brote no suele obviarse nunca este diagnóstico, independientemente de la edad del paciente. A pesar de que el infradiagnóstico pueda estar presente, la indemnidad de la mucosa respiratoria y la ausencia de comorbilidades en este grupo poblacional justifican, en nuestra opinión, esta menor incidencia en los niños. El deterioro de la mucosa respiratoria y la alteración de los cilios causada por el tabaco dificultan la erradicación de la <span class="elsevierStyleItalic">Legionella</span> del árbol bronquial y facilitan su entrada en los macrófagos alveolares. La replicación en ellos, la lisis macrofágica posterior y la reincorporación a otros macrófagos extiende el proceso a límites que variarán según el estado inmunitario del individuo, que, a su vez, constituye el principal factor pronóstico de la enfermedad. Sin embargo, en situaciones donde existan comorbilidades importantes o el inóculo bacteriano pueda ser muy grande, la infección por <span class="elsevierStyleItalic">Legionella</span> debe siempre estar presente en la mente de los pediatras. En la serie de Campins et al. sobre 5 casos de legionelosis nosocomial en niños inmunodeprimidos y en las descripciones de legionelosis en neonatos tras aspiración de agua puede hallarse un ejemplo de ambas situaciones<a class="elsevierStyleCrossRefs" href="#bib0055"><span class="elsevierStyleSup">11,12</span></a>.</p><p id="par0040" class="elsevierStylePara elsevierViewall"><span class="elsevierStyleItalic">Legionella</span> vive en el agua y cualquier interacción entre agua y mucosa respiratoria puede condicionar la infección. La inhalación y la aspiración son los 2 mecanismos implicados con mayor frecuencia en la transmisión de este microorganismo. Un concepto erróneo es pensar que la inhalación justifica todos los casos de legionelosis; la aspiración de agua colonizada, especialmente en adultos con problemas de deglución, se ha relacionado con muchos casos de legionelosis, llegando a considerar algunos autores que es el principal mecanismo de transmisión en el ámbito hospitalario<a class="elsevierStyleCrossRef" href="#bib0065"><span class="elsevierStyleSup">13</span></a>. Este mecanismo, por otra parte, ha sido implicado en muchos casos de legionelosis en neonatos<a class="elsevierStyleCrossRefs" href="#bib0070"><span class="elsevierStyleSup">14,15</span></a>.</p><p id="par0045" class="elsevierStylePara elsevierViewall">El desarrollo de la enfermedad no depende tanto de un contacto banal con <span class="elsevierStyleItalic">Legionella</span>, como del inóculo y la virulencia. Diferentes son las circunstancias que pueden incrementar el inóculo bacteriano en la fase planctónica de un continente acuático. Una de las menos conocidas, pero a nuestro entender muy importante, es la disrupción del <span class="elsevierStyleItalic">biofilm</span> de la pared del continente, que conduce a la liberación de <span class="elsevierStyleItalic">Legionella</span> libres, amebas y fagosomas a la fase acuosa. Es probable que la transmisión de fragmentos de amebas o de fagosomas amebianos pletóricos de <span class="elsevierStyleItalic">Legionella</span> desempeñe un papel más importante y más efectivo que la transmisión a través de <span class="elsevierStyleItalic">Legionella</span> libres (inóculo mucho menor). Diferentes circunstancias pueden provocar esta situación y muy especialmente aquellas que ocasionan turbulencias en el interior del continente acuoso. La más conocida es la que acompaña a los aumentos de flujo durante determinadas épocas estacionales o, tal como se demuestra en estudios experimentales, a determinadas maniobras de desinfección del agua, denominadas de choque<a class="elsevierStyleCrossRef" href="#bib0080"><span class="elsevierStyleSup">16</span></a>. No conocemos estudios sobre si las turbulencias producidas en nebulizadores o humidificadores por el paso rápido del aire pueden conducir a situaciones similares. La menor superficie de la biocapa que poseen estos pequeños aparatos (pequeños en comparación a una torre de refrigeración o un circuito de agua sanitaria caliente) lo hacen más difícil, pero en aquellos poco cuidados o con agua estancada durante cierto tiempo podría producirse este fenómeno.</p><p id="par0050" class="elsevierStylePara elsevierViewall">Se han descrito, por otra parte, distintos factores de virulencia para <span class="elsevierStyleItalic">Legionella</span> y es conocido el hecho de que muchas especies de esta conviven en el entorno acuático, por ejemplo, de centros sanitarios, sin que nunca se hayan relacionado con casos nosocomiales<a class="elsevierStyleCrossRefs" href="#bib0085"><span class="elsevierStyleSup">17,18</span></a>.</p><p id="par0055" class="elsevierStylePara elsevierViewall">El Real Decreto 865/2003 del Ministerio de Sanidad<a class="elsevierStyleCrossRef" href="#bib0095"><span class="elsevierStyleSup">19</span></a> establece una serie de medidas destinadas a la prevención de la legionelosis, medidas que inciden fundamentalmente sobre aspectos ambientales, especialmente mantenimiento de instalaciones, y menos sobre aspectos sanitarios. Por otra parte, existe en los últimos años una proliferación de empresas de sectores relacionados con el mantenimiento de instalaciones y tratamientos de agua que se han erigido en expertos en esta temática y se les ha asignado en muchos casos responsabilidades que escapan a su competencia. Si bien es cierto que el mantenimiento de las instalaciones consideradas de riesgo ha mejorado notablemente, lo que ha repercutido en el tamaño de los brotes –no en el número de los mismos–, los aspectos relacionados con la interpretación del ecosistema y los mecanismos de transmisión, aspectos muy importantes en la prevención de la enfermedad, no han experimentado el mismo desarrollo. Se llega a pensar, incluso, que el problema de la legionelosis es ambiental, y que la presencia de <span class="elsevierStyleItalic">Legionella</span> en el agua se relaciona indefectiblemente con la presencia de legionelosis humana. No es fácil interpretar el significado de las distintas especies de <span class="elsevierStyleItalic">Legionella</span> en un circuito de agua sanitaria, o decidir sobre qué inóculo o porcentaje de puntos positivos deben establecerse como niveles de alarma en el agua sanitaria. Deben conocerse bien todas aquellas maniobras sanitarias que puedan facilitar la interacción agua-mucosa respiratoria y favorecer el desarrollo de la infección.</p><p id="par0060" class="elsevierStylePara elsevierViewall">Si bien en los grandes hospitales los servicios de medicina preventiva son conscientes de esta problemática, no ocurre siempre lo mismo en centros sanitarios más pequeños y residencias de la tercera edad, y menos todavía fuera del entorno sanitario, donde la prevención se limita muchas veces al buen mantenimiento de las instalaciones denominadas de riesgo. Sin embargo, son tantos los posibles orígenes de la infección<a class="elsevierStyleCrossRefs" href="#bib0100"><span class="elsevierStyleSup">20–26</span></a>, que se hace muy difícil, a pesar del esfuerzo de la administración con sus controles rigurosos y frecuentes, erradicar totalmente este riesgo. Un ejemplo lo tenemos en el trabajo de Bonilla et al.<a class="elsevierStyleCrossRef" href="#bib0130"><span class="elsevierStyleSup">26</span></a>, que describe un caso de neumonía por <span class="elsevierStyleItalic">Legionella</span> asociado al uso de un humidificador doméstico. Entre las fuentes difíciles de reconocer están los humidificadores, domésticos, comerciales o industriales. A pesar de que existen descripciones al respecto<a class="elsevierStyleCrossRefs" href="#bib0135"><span class="elsevierStyleSup">27–29</span></a>, siempre es difícil pensar en esta posibilidad y más tratándose de un niño, por otra parte inmunocompetente. El trabajo de investigación epidemiológica, descriptiva y molecular realizado por estos autores cabe calificarlo de excelente.</p><p id="par0065" class="elsevierStylePara elsevierViewall">La legionelosis continúa ofreciendo un campo de investigación apasionante y con enormes interrogantes a resolver. Si bien es verdad que desde un punto de vista clínico y/o terapéutico está bastante acotado gracias al impulso que durante varios años le han dado investigadores clínicos, no es así en sus vertientes epidemiológicas (nuevas fuentes y mecanismos de transmisión), de patogenicidad (factores de virulencia, entre otros), de prevención, o de alternativas a la desinfección convencional. Muchos grupos están, por otra parte, investigando métodos nuevos de detección rápida de <span class="elsevierStyleItalic">Legionella</span> en el agua y/o de detección sobre muestras clínicas que permitan ampliar el diagnóstico clínico a otras especies y serogrupos. Tal como apuntábamos al inicio de este editorial, conocemos bien la historia natural de la infección por <span class="elsevierStyleItalic">L. pneumophila</span> sg 1, pero es muy probable que estas últimas técnicas, al igual que ocurrió con la introducción del test urinario actual, nos obliguen a modificar muchos de los conceptos actuales sobre esta problemática.</p></span>" "pdfFichero" => "main.pdf" "tienePdf" => true "bibliografia" => array:2 [ "titulo" => "Bibliografía" "seccion" => array:1 [ 0 => array:2 [ "identificador" => "bibs0005" "bibliografiaReferencia" => array:29 [ 0 => array:3 [ "identificador" => "bib0005" "etiqueta" => "1" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Legionella infection" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:2 [ 0 => "M. Sabria" 1 => "V.L. Yu" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "LibroEditado" => array:6 [ "editores" => "D.LongoA.FauciD.KasperS.HauserJ.JamesonJ.Loscalzo" "paginaInicial" => "1236" "paginaFinal" => "1241" "edicion" => "18th edition." "serieTitulo" => "Harrison's Principles of Internal Medicine" "serieFecha" => "2012" ] ] ] ] ] ] 1 => array:3 [ "identificador" => "bib0010" "etiqueta" => "2" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Commercial potting soils as an alternative infection source of Legionella pneumophila and other Legionella species in Switzerland" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "S. Casati" 1 => "A. Gioria-Martinoni" 2 => "V. Gaia" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1111/j.1469-0691.2009.02742.x" "Revista" => array:6 [ "tituloSerie" => "Clin Microbiol Infect" "fecha" => "2009" "volumen" => "15" "paginaInicial" => "571" "paginaFinal" => "575" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/19392903" "web" => "Medline" ] ] ] ] ] ] ] ] 2 => array:3 [ "identificador" => "bib0015" "etiqueta" => "3" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Legionella longbeachae serogroup 1 infections linked to potting compost" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:6 [ 0 => "D.S. Lindsay" 1 => "A.W. Brown" 2 => "D.J. Brown" 3 => "S.J. Pravinkumar" 4 => "E. Anderson" 5 => "G.F. Edwards" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1099/jmm.0.035857-0" "Revista" => array:6 [ "tituloSerie" => "J Med Microbiol" "fecha" => "2012" "volumen" => "61" "paginaInicial" => "218" "paginaFinal" => "222" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/21940651" "web" => "Medline" ] ] ] ] ] ] ] ] 3 => array:3 [ "identificador" => "bib0020" "etiqueta" => "4" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Biofilms: The environmental playground of Legionella pneumophila" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:1 [ 0 => "P. Declerck" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1111/j.1462-2920.2009.02025.x" "Revista" => array:6 [ "tituloSerie" => "Environ Microbiol" "fecha" => "2010" "volumen" => "12" "paginaInicial" => "557" "paginaFinal" => "566" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/19678829" "web" => "Medline" ] ] ] ] ] ] ] ] 4 => array:3 [ "identificador" => "bib0025" "etiqueta" => "5" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "The efficacy of heat and chlorine treatment against thermotolerant Acanthamoebae and Legionellae" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:4 [ 0 => "M.V. Storey" 1 => "J. Winiecka-Krusnell" 2 => "N.J. Ashbolt" 3 => "T.A. Stenström" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1080/00365540410020785" "Revista" => array:6 [ "tituloSerie" => "Scand J Infect Dis" "fecha" => "2004" "volumen" => "36" "paginaInicial" => "656" "paginaFinal" => "662" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/15370652" "web" => "Medline" ] ] ] ] ] ] ] ] 5 => array:3 [ "identificador" => "bib0030" "etiqueta" => "6" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Prospective study of community-acquired pneumonia of bacterial etiology in adults" "autores" => array:1 [ 0 => array:2 [ "etal" => true "autores" => array:6 [ 0 => "N. Sopena" 1 => "M. Sabrià" 2 => "M.L. Pedro-Botet" 3 => "J.M. Manterola" 4 => "L. Matas" 5 => "J. Domínguez" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Eur J Clin Microbiol Infect Dis" "fecha" => "1999" "volumen" => "18" "paginaInicial" => "852" "paginaFinal" => "858" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/10691195" "web" => "Medline" ] ] ] ] ] ] ] ] 6 => array:3 [ "identificador" => "bib0035" "etiqueta" => "7" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Community-acquired Legionella pneumophila pneumonia: A single-center experience with 214 hospitalized sporadic cases over 15 years" "autores" => array:1 [ 0 => array:2 [ "etal" => true "autores" => array:6 [ 0 => "D. Viasus" 1 => "S. di Yacovo" 2 => "C. Garcia-Vidal" 3 => "R. Verdaguer" 4 => "F. Manresa" 5 => "J. Dorca" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:5 [ "tituloSerie" => "Medicine (Baltimore)" "fecha" => "2013" "volumen" => "92" "paginaInicial" => "51" "paginaFinal" => "60" ] ] ] ] ] ] 7 => array:3 [ "identificador" => "bib0040" "etiqueta" => "8" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Community outbreak of pneumonia due to Legionella pneumophila: Importance of monitoring hospital cooling towers" "autores" => array:1 [ 0 => array:2 [ "etal" => true "autores" => array:6 [ 0 => "P.G. De Olalla" 1 => "J. Gracia" 2 => "C. Rius" 3 => "J.A. Cayla" 4 => "H. Panella" 5 => "J.R. Villabi" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Enferm Infecc Microbiol Clin" "fecha" => "2008" "volumen" => "26" "paginaInicial" => "15" "paginaFinal" => "22" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/19195464" "web" => "Medline" ] ] ] ] ] ] ] ] 8 => array:3 [ "identificador" => "bib0045" "etiqueta" => "9" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Community-acquired Legionella pneumonia: New insights from the German competence network for community acquired pneumonia" "autores" => array:1 [ 0 => array:2 [ "etal" => true "autores" => array:6 [ 0 => "H. Von Baum" 1 => "S. Ewig" 2 => "R. Marre" 3 => "N. Suttorp" 4 => "S. Gonschior" 5 => "T. Welte" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1086/586741" "Revista" => array:6 [ "tituloSerie" => "Clin Infect Dis" "fecha" => "2008" "volumen" => "46" "paginaInicial" => "1356" "paginaFinal" => "1364" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/18419436" "web" => "Medline" ] ] ] ] ] ] ] ] 9 => array:3 [ "identificador" => "bib0050" "etiqueta" => "10" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Problem pathogens: Paediatric legionellosis-implications for improved diagnosis" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:5 [ 0 => "D. Greenberg" 1 => "C.C. Chiou" 2 => "R. Famigilleti" 3 => "T.C. Lee" 4 => "V.L. Yu" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:4 [ "tituloSerie" => "Lancet" "fecha" => "2006" "volumen" => "6" "paginaInicial" => "529535" ] ] ] ] ] ] 10 => array:3 [ "identificador" => "bib0055" "etiqueta" => "11" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Nosocomial Legionnaire's disease in a children's hospital" "autores" => array:1 [ 0 => array:2 [ "etal" => true "autores" => array:6 [ 0 => "M. Campins" 1 => "A. Ferrer" 2 => "L. Callís" 3 => "C. Pelaz" 4 => "P.J. Cortés" 5 => "N. Pinart" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Pediatr Infect Dis J" "fecha" => "2000" "volumen" => "19" "paginaInicial" => "228" "paginaFinal" => "234" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/10749465" "web" => "Medline" ] ] ] ] ] ] ] ] 11 => array:3 [ "identificador" => "bib0060" "etiqueta" => "12" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Legionella pneumophila pneumonia in a newborn after water birth: A new mode of transmission" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:5 [ 0 => "L. Franzin" 1 => "C. Scolfaro" 2 => "D. Cabodi" 3 => "M. Valera" 4 => "P.A. Tovo" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:5 [ "tituloSerie" => "Clin Infect Dis" "fecha" => "2001" "volumen" => "33" "paginaInicial" => "103" "paginaFinal" => "104" ] ] ] ] ] ] 12 => array:3 [ "identificador" => "bib0065" "etiqueta" => "13" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Hospital-acquired legionellosis: Solutions for a preventable infection" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:2 [ 0 => "M. Sabria" 1 => "V.L. Yu" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Lancet Infect Dis" "fecha" => "2002" "volumen" => "2" "paginaInicial" => "368" "paginaFinal" => "373" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/12144900" "web" => "Medline" ] ] ] ] ] ] ] ] 13 => array:3 [ "identificador" => "bib0070" "etiqueta" => "14" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Fatal hospital-acquired Legionella pneumonia in a neonate" "autores" => array:1 [ 0 => array:2 [ "etal" => true "autores" => array:6 [ 0 => "Y. Shachor-Meyouhas" 1 => "I. Kassis" 2 => "E. Bamberger" 3 => "T. Nativ" 4 => "H. Sprecher" 5 => "I. Levy" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1097/INF.0b013e3181c176c9" "Revista" => array:6 [ "tituloSerie" => "Pediatr Infect Dis J" "fecha" => "2010" "volumen" => "29" "paginaInicial" => "280" "paginaFinal" => "281" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/19934790" "web" => "Medline" ] ] ] ] ] ] ] ] 14 => array:3 [ "identificador" => "bib0075" "etiqueta" => "15" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Legionella pneumophila serogroup 1 in a birthing pool" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:2 [ 0 => "L. Teare" 1 => "S. Millership" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.jhin.2012.06.012" "Revista" => array:6 [ "tituloSerie" => "J Hosp Infect" "fecha" => "2012" "volumen" => "82" "paginaInicial" => "58" "paginaFinal" => "60" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/22854354" "web" => "Medline" ] ] ] ] ] ] ] ] 15 => array:3 [ "identificador" => "bib0080" "etiqueta" => "16" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Development of a pilot-scale 1 for legionella elimination in biofilm in hot water network: Heat shock treatment evaluation" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:6 [ 0 => "M. Farhat" 1 => "M.C. Trouilhe" 2 => "E. Briand" 3 => "M. Moletta-Denat" 4 => "E. Robine" 5 => "J. Frere" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1111/j.1365-2672.2009.04541.x" "Revista" => array:6 [ "tituloSerie" => "J Appl Microbiol" "fecha" => "2010" "volumen" => "108" "paginaInicial" => "1073" "paginaFinal" => "1082" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/19796094" "web" => "Medline" ] ] ] ] ] ] ] ] 16 => array:3 [ "identificador" => "bib0085" "etiqueta" => "17" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Environmental cultures and hospital-acquired Legionnaires’ disease: A 5-year prospective study in 20 hospitals in Catalonia, Spain" "autores" => array:1 [ 0 => array:2 [ "etal" => true "autores" => array:6 [ 0 => "M. Sabrià" 1 => "J.M. Mòdol" 2 => "M. Garcia-Nuñez" 3 => "E. Reynaga" 4 => "M.L. Pedro-Botet" 5 => "N. Sopena" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1086/502346" "Revista" => array:6 [ "tituloSerie" => "Infect Control Hosp Epidemiol" "fecha" => "2004" "volumen" => "25" "paginaInicial" => "1072" "paginaFinal" => "1076" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/15636295" "web" => "Medline" ] ] ] ] ] ] ] ] 17 => array:3 [ "identificador" => "bib0090" "etiqueta" => "18" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Cytopathogenicity and molecular subtyping of Legionella pneumophila environmental isolates from 17 hospitals" "autores" => array:1 [ 0 => array:2 [ "etal" => true "autores" => array:6 [ 0 => "M. Garcia-Nuñnez" 1 => "M.L. Pedro-Botet" 2 => "S. Ragull" 3 => "N. Sopena" 4 => "J. Morera" 5 => "C. Rey-Joly" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1017/S0950268808000691" "Revista" => array:6 [ "tituloSerie" => "Epidemiol Infect" "fecha" => "2009" "volumen" => "137" "paginaInicial" => "188" "paginaFinal" => "193" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/18538055" "web" => "Medline" ] ] ] ] ] ] ] ] 18 => array:3 [ "identificador" => "bib0095" "etiqueta" => "19" "referencia" => array:1 [ 0 => array:1 [ "referenciaCompleta" => "Boletín Oficial del Estado. Real Decreto 865/2003, de 4 de Jul, por el que se establecen los criterios higiénico-sanitarios para la prevención y control de la legionelosis. BOE núm 171, de 18 de julio de 2003. p. 28055–69." ] ] ] 19 => array:3 [ "identificador" => "bib0100" "etiqueta" => "20" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Contamination of a dental unit water line system by legionella pneumophila in the mashhad school of dentistry in 2009" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:6 [ 0 => "B. Ajami" 1 => "K. Ghazvini" 2 => "T. Movahhed" 3 => "N. Ariaee" 4 => "M. Shakeri" 5 => "S. Makarem" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Iran Red Crescent Med J" "fecha" => "2012" "volumen" => "14" "paginaInicial" => "376" "paginaFinal" => "378" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/22924117" "web" => "Medline" ] ] ] ] ] ] ] ] 20 => array:3 [ "identificador" => "bib0105" "etiqueta" => "21" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Outbreak of Legionnaires’ disease associated with a supermarket mist machine" "autores" => array:1 [ 0 => array:2 [ "etal" => true "autores" => array:6 [ 0 => "I. Barrabeig" 1 => "A. Rovira" 2 => "M. Garcia" 3 => "J.M. Oliva" 4 => "A. Vilamala" 5 => "M.D. Ferrer" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1017/S0950268810000841" "Revista" => array:6 [ "tituloSerie" => "Epidemiol Infect" "fecha" => "2010" "volumen" => "138" "paginaInicial" => "1823" "paginaFinal" => "1828" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/20392306" "web" => "Medline" ] ] ] ] ] ] ] ] 21 => array:3 [ "identificador" => "bib0110" "etiqueta" => "22" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "A case of Legionnaires’ disease caused by aspiration of ice water" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:6 [ 0 => "M.A. Bencini" 1 => "E.P. Yzerman" 2 => "R.H. Koornstra" 3 => "C.C. Nolte" 4 => "J.W. den Boer" 5 => "J.P. Bruin" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.3200/AEOH.60.6.302-306" "Revista" => array:6 [ "tituloSerie" => "Arch Environ Occup Health" "fecha" => "2005" "volumen" => "60" "paginaInicial" => "302" "paginaFinal" => "306" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/17447574" "web" => "Medline" ] ] ] ] ] ] ] ] 22 => array:3 [ "identificador" => "bib0115" "etiqueta" => "23" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Legionnaires’ disease outbreak associated with a cruise liner, August 2003: Epidemiological and microbiological findings" "autores" => array:1 [ 0 => array:2 [ "etal" => true "autores" => array:6 [ 0 => "K. Beyrer" 1 => "S. Lai" 2 => "J. Dreesman" 3 => "J.V. Lee" 4 => "C. Joseph" 5 => "T. Harrison" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1017/S0950268806007473" "Revista" => array:6 [ "tituloSerie" => "Epidemiol Infect" "fecha" => "2007" "volumen" => "135" "paginaInicial" => "802" "paginaFinal" => "810" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/17109773" "web" => "Medline" ] ] ] ] ] ] ] ] 23 => array:3 [ "identificador" => "bib0120" "etiqueta" => "24" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Cluster of Legionnaires’ disease associated with a public whirlpool spa, France, April-May 2010" "autores" => array:1 [ 0 => array:2 [ "etal" => true "autores" => array:6 [ 0 => "C. Campese" 1 => "D. Roche" 2 => "C. Clement" 3 => "F. Fierobe" 4 => "S. Jarraud" 5 => "P. de Waelle" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:5 [ "tituloSerie" => "Euro Surveill" "fecha" => "2010" "volumen" => "15" "paginaInicial" => "19602" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/20619131" "web" => "Medline" ] ] ] ] ] ] ] ] 24 => array:3 [ "identificador" => "bib0125" "etiqueta" => "25" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Wellness centres: An important but overlooked source of Legionnaires disease. Eight years of source investigation in the Netherlands, 1 August 2002 to 1 August 2010" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:5 [ 0 => "S.M. Euser" 1 => "J.P. Bruin" 2 => "W. van der Hoek" 3 => "W.A. Schop" 4 => "J.W. den Boer" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:5 [ "tituloSerie" => "Euro Surveill" "fecha" => "2012" "volumen" => "17" "paginaInicial" => "20097" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/22401507" "web" => "Medline" ] ] ] ] ] ] ] ] 25 => array:3 [ "identificador" => "bib0130" "etiqueta" => "26" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Neumonía por Legionella pnumophila asociada al uso de un humidificador doméstico en un niño inmunocompetente" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "B.A. Bonilla" 1 => "J.C. Montero" 2 => "G. Martinez" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:5 [ "tituloSerie" => "Med Clin" "fecha" => "2014" "volumen" => "142" "paginaInicial" => "70" "paginaFinal" => "72" ] ] ] ] ] ] 26 => array:3 [ "identificador" => "bib0135" "etiqueta" => "27" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Humidifier-associated paediatric Legionnaires’ disease, Israel, February 2012" "autores" => array:1 [ 0 => array:2 [ "etal" => true "autores" => array:6 [ 0 => "J. Moran-Gilad" 1 => "T. Lazarovitch" 2 => "M. Mentasti" 3 => "T. Harrison" 4 => "M. Weinberger" 5 => "Y. Mordish" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:5 [ "tituloSerie" => "Euro Surveill" "fecha" => "2012" "volumen" => "17" "paginaInicial" => "20293" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/23078810" "web" => "Medline" ] ] ] ] ] ] ] ] 27 => array:3 [ "identificador" => "bib0140" "etiqueta" => "28" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "First outbreak of nosocomial legionella infection in term neonates caused by a cold mist ultrasonic humidifier" "autores" => array:1 [ 0 => array:2 [ "etal" => true "autores" => array:6 [ 0 => "P.K. Yiallouros" 1 => "T. Papadouri" 2 => "C. Karaoli" 3 => "E. Papamichael" 4 => "M. Zeniou" 5 => "D. Pieridou-Bagatzouni" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1093/cid/cit176" "Revista" => array:6 [ "tituloSerie" => "Clin Infect Dis" "fecha" => "2013" "volumen" => "57" "paginaInicial" => "48" "paginaFinal" => "56" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/23511302" "web" => "Medline" ] ] ] ] ] ] ] ] 28 => array:3 [ "identificador" => "bib0145" "etiqueta" => "29" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Outbreak of legionnaires’ disease associated with a supermarket mist machine" "autores" => array:1 [ 0 => array:2 [ "etal" => true "autores" => array:6 [ 0 => "I. Barrabeig" 1 => "A. Rovira" 2 => "M. Garcia" 3 => "J.M. Oliva" 4 => "A. Vilamala" 5 => "M.D. Ferrer" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1017/S0950268810000841" "Revista" => array:6 [ "tituloSerie" => "Epidemiol Infect" "fecha" => "2010" "volumen" => "138" "paginaInicial" => "1823" "paginaFinal" => "1828" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/20392306" "web" => "Medline" ] ] ] ] ] ] ] ] ] ] ] ] ] "idiomaDefecto" => "es" "url" => "/00257753/0000014200000002/v1_201401110110/S002577531300537X/v1_201401110110/es/main.assets" "Apartado" => array:4 [ "identificador" => "55623" "tipo" => "SECCION" "es" => array:2 [ "titulo" => "Editorial retrospectivo" "idiomaDefecto" => true ] "idiomaDefecto" => "es" ] "PDF" => "https://static.elsevier.es/multimedia/00257753/0000014200000002/v1_201401110110/S002577531300537X/v1_201401110110/es/main.pdf?idApp=UINPBA00004N&text.app=https://www.elsevier.es/" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S002577531300537X?idApp=UINPBA00004N" ]
Consulte los artículos y contenidos publicados en este medio, además de los e-sumarios de las revistas científicas en el mismo momento de publicación
Esté informado en todo momento gracias a las alertas y novedades
Acceda a promociones exclusivas en suscripciones, lanzamientos y cursos acreditados
Medicina Clínica, fundada en 1943, es la única publicación semanal de contenido clínico que se edita en España y constituye el máximo exponente de la calidad y pujanza de la medicina española. Son características fundamentales de esta publicación el rigor científico y metodológico de sus artículos, la actualidad de los temas y, sobre todo, su sentido práctico, buscando siempre que la información sea de la mayor utilidad en la práctica clínica. Los contenidos de Medicina Clínica abarcan dos frentes: trabajos de investigación original rigurosamente seleccionados atendiendo a su calidad, originalidad e interés, y trabajos orientados a la formación continuada, encomendados por la revista a autores relevantes (Editoriales, Revisiones, Conferencias clínicas y clínico-patológicas, Diagnóstico y Tratamiento). En estos artículos se ponen al día aspectos de destacado interés clínico o conceptual en la medicina actual. Medicina Clínica es un vehículo de información científica de reconocida calidad, como demuestra su inclusión en los más prestigiosos y selectivos índices bibliográficos del mundo.
Current Contents/Clinical Medicine, Journal Citation Reports, SCI-Expanded, Index Medicus/Medline, Excerpta Medica/EMBASE, IBECS, IME, MEDES, PASCAL, SCOPUS, ScienceDirect
Ver másEl factor de impacto mide la media del número de citaciones recibidas en un año por trabajos publicados en la publicación durante los dos años anteriores.
© Clarivate Analytics, Journal Citation Reports 2022
SJR es una prestigiosa métrica basada en la idea de que todas las citaciones no son iguales. SJR usa un algoritmo similar al page rank de Google; es una medida cuantitativa y cualitativa al impacto de una publicación.
Ver másSNIP permite comparar el impacto de revistas de diferentes campos temáticos, corrigiendo las diferencias en la probabilidad de ser citado que existe entre revistas de distintas materias.
Ver más¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?
Are you a health professional able to prescribe or dispense drugs?
Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos