covid
Buscar en
Revista Clínica de Periodoncia, Implantología y Rehabilitación Oral
Toda la web
Inicio Revista Clínica de Periodoncia, Implantología y Rehabilitación Oral Evaluación in vitro de la resistencia compresiva de un sellante resinoso fluora...
Información de la revista
Vol. 5. Núm. 1.
Páginas 9-12 (abril 2012)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Vol. 5. Núm. 1.
Páginas 9-12 (abril 2012)
Open Access
Evaluación in vitro de la resistencia compresiva de un sellante resinoso fluorado pre y post liberación de flúor
In vitro compressive strength of fluoride-containing resin-based sealant before and after fluoride release
Visitas
1395
C. Vergara1, S. Uribe2,
Autor para correspondencia
sergiouribe@uach.cl

Correspondencia autor: Cátedra de Cariología, Escuela de Odontología, Facultad de Medicina, Universidad Austral de Chile. Valdivia, Chile. Rudloff #1640, Valdivia, Chile.
1 Alumna Odontología. Escuela de Odontología. Alumna Programa de Honor en Investigación. Facultad de Medicina, Universidad Austral de Chile. Valdivia, Chile
2 Profesor Asociado. Escuela de Odontología, Facultad de Medicina, Universidad Austral de Chile. Valdivia, Chile
Este artículo ha recibido

Under a Creative Commons license
Información del artículo
Resumen
Bibliografía
Descargar PDF
Estadísticas
Resumen
Objetivo

Evaluar in vitro la resistencia compresiva de un sellante resinoso fluorado (F) pre y post liberación de flúor luego de la inmersión en agua.

Método

Se utilizaron 40 probetas de 6mm de alto y 20mm de diámetro de sellante resinoso fluorado (FluroShield, Brasil, Dentsply) y de sellante no fluorado (Concise(TM) Light Cured White Sealant, USA, 3M ESPE). Las probetas fueron divididas en cuatro grupos, dos de sellante resinoso fluorado (F1 y F2) y dos de control (C1 y C2). Un grupo de probetas de sellante fluorado y un grupo del control (F1/C1) se mantuvieron sin exposición al agua, mientras que los grupos restantes (F2/C2) fueron inmersos en agua destilada por 30 días. Se midió la liberación de flúor desde el grupo F2 mediante el método de electrodo selectivo los días 1, 2, 3 y 30. Posteriormente se midió la resistencia compresiva mediante una máquina de ensayos mecánicos universales (Lloyd, LR 100, UK) con una velocidad de cruceta de 1mm/min. Las comparaciones entre los grupos F1 vs F2 y C1 vs C2 se analizaron con t-Student. El nivel de significancia se estableció a 0.05.

Resultados

La resistencia compresiva en MPa antes y después de la inmersión en agua para el sellante resinoso fluorado fue 337.2 y 337.4, mientras que la del sellante control fue 203.8 y 213.4. Para ambos grupos las diferencias observadas no fueron significativas. Se observó un patrón de liberación de flúor inicial de 1.9ppm durante las primeras 24 horas para luego decaer a 0.0ppm al tercer día de liberación.

Conclusión

La liberación de flúor desde un sellante resinoso fluorado no afectó su resistencia compresiva en este estudio in vitro.

Palabras clave:
Fluoruros
sellantes de fosas y fisuras
resistencia compresiva
in vitro
Abstract
Aim

To evaluate in vitro compressive strength of fluoride-containing resin-based sealant (F) before and after fluoride release in water.

Materials and Methods

We used 40 specimens with 6mm of height and 20mm of diameter using fluoride-containing resin-based sealant (FluroShield,Brasil, Dentsply) and non-fluoride-containing resin-based sealant (Concise (TM) Light Cured White Sealant, USA, 3M ESPE). The specimens were divided into four groups, two fluoride-containing resin-based sealants (F1 and F2) and two like control groups (C1 and C2). A group of specimens of fluoride-containing resin-based sealant and a control group (F1/C1) remained without exposure to water, while other groups (F2/C2) were immersed in distilled water for 30 days. The release of fluoride from the F2 was measured through selective electrode method on days 1, 2, 3 and 30. Subsequently, the compressive strength was measured using a universal testing machine (Lloyd, LR 100, UK) with a crosshead speed of 1mm/min. Comparisons between groups F1 vs F2 and C1 vs C2 were analyzed with t-Student. The significance level was set at 0.05.

Results

The compressive strength (Mpa) before and after immersion in water for fluoride-containing resin-based sealant was 337.2 and 337.4, while the control sealant was 203.8 and 213.4. For both groups the observed differences were not significant. The initial fluoride release was 1.9ppm during the first 24 hours and then declined to 0.0ppm during the third day of release.

Conclusion

In this in vitro study, the release of fluoride from a fluoride-containing resin-based sealant does not affect compressive strength.

Key words:
Fluorides
pit and fissure sealants
compressive strength
in vitro
El Texto completo está disponible en PDF
Referencias bibliográficas
[1.]
L.M. Kaste, R.H. Selwitz, R.J. Oldakowski.
Coronal caries in the primary and permanent dentition of children and adolescents 1-17 years of age: United States, 1988-1991.
J Dent Res, 75 (1996), pp. 631-641
[2.]
A. Ahovuo-Saloranta, A. Hiiri, A. Nordblad, M. Mäkelä, H.V. Worthington.
Pit and fissure sealants for preventing dental decay in the permanent teeth of children and adolescents.
Cochrane Database Syst Rev, 4 (2008), pp. CD001830
[3.]
B.F. Gooch, S.O. Griffin, S.K. Gray, W.G. Kohn, R.G. Rozier, M. Siegal, M. Fontana, D. Brunson, N. Carter, D.K. Curtis, K.J. Donly, H. Haering, L.F. Hill, H.P. Hinson, J. Kumar, L. Lampiris, M. Mallatt, D.M. Meyer, W.R. Miller, S.M. Sanzi- Schaedel, R. Simonsen, B.I. Truman, D.T. Zero.
Centers for disease control and prevention. Preventing dental caries through school-based sealant programs: Updated recommendations and reviews of evidence.
J Am Dent Assoc, 140 (2009), pp. 1356-1365
[4.]
R.J. Simonsen.
Glass ionomer as fissure sealant - a critical review.
J Public Health Dent, 56 (1996), pp. 146-149
[5.]
R.G. Romcke, D.W. Lewis, B.D. Maze, R.A. Vickerson.
Retention and maintenance of fissure sealants over 10 years.
J Can Dent Assoc, 56 (1990), pp. 235-237
[6.]
S. Kavaloglu Cildir, N. Sandalli.
Compressive strength, surface roughness, fluoride release and recharge of four new fluoride-releasing fissure sealants.
Dent Mater J, 26 (2007), pp. 335-341
[7.]
J.A. Cury, L.M.A. Tenuta.
Enamel remineralization: Controlling the caries disease or treating early caries lesions?.
Braz Oral Res, 23 (2009), pp. 23-30
[8.]
M.L. Swartz, R.W. Phillips, R.D. Norman, S. Elliason, B.F. Rhodes, H.E. Clark.
Addition of fluoride to pit and fissure sealants-a feasibility study.
J Dent Res, 55 (1976), pp. 757-771
[9.]
X. Xu, J.O. Burgess.
Compressive strength, fluoride release and recharge of fluoride-releasing materials.
Biomaterials, 24 (2003), pp. 2451-2461
[10.]
J.A. Cury, J.C. Saad, A.L. Rodrigues Jr..
Liberação de flúor do selante Na agua, saliva e soluções desmineralizante-remineralizante.
RGO, 41 (1993), pp. 273-275
Copyright © 2012. Sociedad de Periodoncia de Chile, Sociedad de Implantología Oral de Chile y Sociedad de Prótesis y Rehabilitación Oral de Chile
Opciones de artículo